Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

The Proton and Electron Aurora as Seen by Image-FUV and FAST

The Far Ultraviolet (FUV) instrument on IMAGE images the aurora in three different wavelength regions. The Wideband Imaging Camera (WIC) observes the molecular Lyman-Birge-Hopfield (LBH) and atomic Nitrogen emissions at 140-190 nm. The two channels of the Spectrographic Imager (SI) observe the Doppler shifted Lyman Alpha emission of precipitating protons at 121.8 nm (SI 12) and the mostly electron produced emission from oxygen OI at 135.6 nm (SI13). The major advantage of FUV compared to previously flown UV imagers is the simultaneous operation of all three imaging systems without the need for filter changes and the uncertainty of temporal changes of the aurora between exposures. The FAST satellite passes every two hours through FUV images during apogee operations. This enables a comparison between the remotely imaged particle precipitation and the in-situ measurements along the FAST track. The detailed analysis of images from all three systems together with a full simulation of auroral emissions based on in-situ measurements by FAST confirms the laboratory calibrations of FUV. The spatial resolution and image quality of WIC permits the observation of a good correspondence between in-situ and remote measurements of precipitation boundaries. The clear separation between the lower latitude proton precipitation and the more structured higher latitude electron precipitation is obtained with both SI-channels.

Gerard, J.-C.↗

Spectroscopic Chemical Analysis Methods and Apparatus

This invention relates to non-contact spectroscopic methods and apparatus for performing chemical analysis and the ideal wavelengths and sources needed for this analysis. It employs deep ultraviolet (200- to 300-nm spectral range) electron-beam-pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor lightemitting devices, and hollow cathode metal ion lasers. Three achieved goals for this innovation are to reduce the size (under 20 L), reduce the weight [under 100 lb (.45 kg)], and reduce the power consumption (under 100 W). This method can be used in microscope or macroscope to provide measurement of Raman and/or native fluorescence emission spectra either by point-by-point measurement, or by global imaging of emissions within specific ultraviolet spectral bands. In other embodiments, the method can be used in analytical instruments such as capillary electrophoresis, capillary electro-chromatography, high-performance liquid chromatography, flow cytometry, and related instruments for detection and identification of unknown analytes using a combination of native fluorescence and/or Raman spectroscopic methods. This design provides an electron-beampumped semiconductor radiation-producing method, or source, that can emit at a wavelength (or wavelengths) below 300 nm, e.g. in the deep ultraviolet between about 200 and 300 nm, and more preferably less than 260 nm. In some variations, the method is to produce incoherent radiation, while in other implementations it produces laser radiation. In some variations, this object is achieved by using an AlGaN emission medium, while in other implementations a diamond emission medium may be used. This instrument irradiates a sample with deep UV radiation, and then uses an improved filter for separating wavelengths to be detected. This provides a multi-stage analysis of the sample. To avoid the difficulties related to producing deep UV semiconductor sources, a pumping approach has been developed that uses ballistic electron beam injection directly into the active region of a wide bandgap semiconductor material.

Hug, William F.↗

The continuous measurement of hydrogen chloride in the ambient atmosphere using the dual isotope infrared absorption technique

The results of a program to develop a prototype gas filter correlation NDIR analyzer capable of providing the required HCl measurement capability, while maintaining an adequate rejection of any other gases anticipated in the atmosphere are presented. Examples of the performance of the prototype analyzer are presented which show an rms noise equivalent concentration of 0.06 ppm of HCl was achieved while maintaining an electronically determined 10% to 90% time response to gas samples of about 2 seconds. No measureable response was observed to CO2, CO, and H2O while maintaining an adequate rejection of the hydrocarbons, for example CH4 and n-hexane. The experiments were performed which demonstrate that the span stability of the HCl gas filter correlation analyzer is unaffected by the presence of water vapor and which support the belief that the incorporation of a relatively open-volume, multiple path sample cell into the instrument would enable ground station as well as airborne measurements of trace quantities of HCl in the ambient atmosphere to be performed.

Williams, K. G.↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum Machine-Learning for Eigenstate Filtration in Two-Dimensional Materials

Quantum machine-learning algorithms have emerged to be a promising alternative to their classical counterparts as they leverage the power of quantum computers. Such algorithms have been developed to solve problems like electronic structure calculations of molecular systems and spin models in magnetic systems. However, the discussion in all these recipes focuses specifically on targeting the ground state. Herein we demonstrate a quantum algorithm that can filter any energy eigenstate of the system based on either symmetry properties or a predefined choice of the user. The workhorse of our technique is a shallow neural network encoding the desired state of the system with the amplitude computed by sampling the Gibbs–Boltzmann distribution using a quantum circuit and the phase information obtained classically from the nonlinear activation of a separate set of neurons. We show that the resource requirements of our algorithm are strictly quadratic. To demonstrate its efficacy, we use state filtration in monolayer transition metal dichalcogenides which are hitherto unexplored in any flavor of quantum simulations. We implement our algorithm not only on quantum simulators but also on actual IBM-Q quantum devices and show good agreement with the results procured from conventional electronic structure calculations. We thus expect our protocol to provide a new alternative in exploring the band structures of exquisite materials to usual electronic structure methods or machine-learning techniques that are implementable solely on a classical computer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Model-based Prognostics Methodology for Electrolytic Capacitors Based on Electrical Overstress Accelerated Aging

A remaining useful life prediction methodology for electrolytic capacitors is presented. This methodology is based on the Kalman filter framework and an empirical degradation model. Electrolytic capacitors are used in several applications ranging from power supplies on critical avionics equipment to power drivers for electro-mechanical actuators. These devices are known for their comparatively low reliability and given their criticality in electronics subsystems they are a good candidate for component level prognostics and health management. Prognostics provides a way to assess remaining useful life of a capacitor based on its current state of health and its anticipated future usage and operational conditions. We present here also, experimental results of an accelerated aging test under electrical stresses. The data obtained in this test form the basis for a remaining life prediction algorithm where a model of the degradation process is suggested. This preliminary remaining life prediction algorithm serves as a demonstration of how prognostics methodologies could be used for electrolytic capacitors. In addition, the use degradation progression data from accelerated aging, provides an avenue for validation of applications of the Kalman filter based prognostics methods typically used for remaining useful life predictions in other applications.

Electrolytic capacitors↗

DANTE as a primary temperature diagnostic for the NIF iron opacity campaign

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure iron opacities at varying densities and temperatures relevant to the solar interior and to verify recent experimental results obtained at the Sandia Z-machine, that diverge from theory. The first set of NIF experiments collected iron opacity data at ∼150 eV to 160 eV and an electron density of ∼7 × 1021 cm−3, with a goal to study temperatures up to ∼210 eV, with electron densities of up to ∼3 × 1022 cm−3. Among several techniques used to infer the temperature of the heated Fe sample, the absolutely calibrated DANTE-2 filtered diode array routinely provides measurements of the hohlraum conditions near the sample. However, the DANTE-2 temperatures are consistently low compared to pre-shot LASNEX simulations for a range of laser drive energies. We have re-evaluated the estimated uncertainty in the reported DANTE-2 temperatures and also the error generated by varying channel participation in the data analysis. An uncertainty of ±5% or better can be achieved with appropriate spectral coverage, channel participation, and metrology of the viewing slot.

Opachich, Y. P. (ORCID:0000000314323989)↗

Curious cross-field transport effects in multi-ion, magnetized plasma

In contrast to single-ion plasma, multiple-ion-species plasma exhibits new, curious, and large transport effects. On short timescales, where ions exchange momentum, magnetized multi-ion plasma behaves as a most unusual substance, compressible across field lines in number density but incompressible in charge density. It takes 40 times longer for electrons to participate. In this ion–ion cross-field transport regime, we identified the charge-incompressibility heat pump effect, transferring heat both spatially and between species. Curiously, the direction of impurity transport strongly depends on plasma magnetization, characterized by the ratio of light ion gyrofrequency to the collision frequency between light and heavy ion species. The expulsion of heavy ion impurities from a hotspot occurs sufficiently quickly to be observable on MagLIF, so long as plasma becomes sufficiently collisionally magnetized under implosion. Even more curious, multi-ion transport changes its nature in partially ionized plasma, where ions occupy different charge states. In this regime, we identify a partial-ionization deconfinement effect. The combination of cross-field transport, ionization, and recombination leads to a net ion charge moving across magnetic field lines on the ion–ion transport timescale as opposed to the electron–ion transport timescale. Cross-field transport effects in multi-ion plasma are important in a number of applications, including nuclear fusion and plasma mass filters.

Mlodik, M. E. (ORCID:0000000343003941)↗

Atmospheric particle sampler

Positive and/or negative pressure is used to trap airborne particles against a filter. Positive pressure is provided by low molecular weight gas (He or H) to achieve high particle velocity and high capture percentage. Trapped particles are examined under electron microscope.

Miller, C. G.↗

Modifications of the X-ray source and monitor at the X-ray Calibration Facility

In order to test the instruments aboard the Advanced X-ray Astrophysics Facility (AXAF) some modifications will need to be made in the X-ray Calibration Facility at Marshall. Several of these modifications involve the X-ray source and the monitor. The source was redesigned to increase the spectral purity of the beam and decrease its polarization by minimizing the number of bremsstrahlung photons in the beam. This was accomplished by utilizing an annular electron gun which allowed the beam to take off antiparallel to the direction at which electrons are incident on the anode. Two other features of the source are the conical anode which decreases the effective spot size and a rotatable anode and filter wheel which allow the operator to change targets without breaking vacuum. The monitor is an important part of the facility because it is used to determine the X-ray flux at the target. A commercially available solid-state detector, Si(Li), should be used along with appropriate proportional counters for monitoring. This detector will be particularly useful when energy or wavelength dispersive instruments are tested because of its good resolution.

Newbolt, W. Barlow↗

The implementation and operation of a variable-response electronic throttle control system for a TF-104G aircraft

During some flight programs, researchers have encountered problems in the throttle response characteristics of high-performance aircraft. To study and to help solve these problems, the National Aeronautics and Space Administration Ames Research Center's Dryden Flight Research Facility (Ames-Dryden) conducted a study using a TF-104G airplane modified with a variable-response electronic throttle control system. Ames-Dryden investigated the effects of different variables on engine response and handling qualities. The system provided transport delay, lead and lag filters, second-order lags, command rate and position limits, and variable gain between the pilot's throttle command and the engine fuel controller. These variables could be tested individually or in combination. Ten research flights were flown to gather data on engine response and to obtain pilot ratings of the various system configurations. The results should provide design criteria for engine-response characteristics. The variable-response throttle components and how they were installed in the TF-104G aircraft are described. How the variable-response throttle was used in flight and some of the results of using this system are discussed.

Neal, Bradford↗

The NANOGrav 11 yr Data Set: Solar Wind Sounding through Pulsar Timing

The North American Nanohertz Observatory for Gravitational Waves (NANOGrav) has observed dozens ofmillisecond pulsars for over a decade. We have accrued a large collection of dispersion measure (DM)measurements sensitive to the total electron content between Earth and the pulsars at each observation. All lines ofsight cross through the solar wind (SW), which produces correlated DM fluctuations in all pulsars. We develop andapply techniques for extracting the imprint of the SW from the full collection of DM measurements in the recentlyreleased NANOGrav 11 yr data set. We filter out long-timescale DM fluctuations attributable to structure in theinterstellar medium and carry out a simultaneous analysis of all pulsars in our sample that can differentiate thecorrelated signature of the wind from signals unique to individual lines of sight. When treating the SW asspherically symmetric and constant in time, we find the electron number density at 1au to be 7.9 ± 0.2 cm(exp -3). Wefind our data to be insensitive to long-term variation in the density of the wind. We argue that our techniques pairedwith a high-cadence, low-radio-frequency observing campaign of near-ecliptic pulsars would be capable ofmapping out large-scale latitudinal structure in the wind.

Madison, D.R.↗

Solving the electronic structure problem for over 100000 atoms in real space

Using a real-space high-order finite-difference approach, we investigate the electronic structure of large spherical silicon nanoclusters. Within Kohn-Sham density functional theory and using pseudopotentials, we report the self-consistent field convergence of a system with over 100000 atoms: a Si 107,641 ⁢H 9,084 nanocluster with a diameter of 16 nm. Our approach uses Chebyshev-filtered subspace iteration to speed up the convergence of the eigenspace, and blockwise Hilbert space-filling curves to speed up sparse matrix-vector multiplications, all of which are implemented in the parsec code. For the largest system, we utilized 2048 nodes (114 688 cores) on the Frontera machine in the Texas Advanced Computing Center. Our quantitative analysis of the electronic structure shows how it gradually approaches its bulk counterpart as a function of nanocluster size. The band gap is enlarged due to quantum confinement in nanoclusters, but decreases as the system size increases, as expected. In conclusion, our work serves as a proof of concept for the capacity of the real-space approach in efficiently parallelizing very large calculations using high-performance computer platforms, which can straightforwardly be replicated in other systems with more than 10 5 atoms.

0-dimensional systems↗

Quantitative Measurement of Positive and Negative Ion Species Ejected from a Li–O–H Surface by Hydrogen and Noble Gas Ion Irradiation

We report sputtering yields of Li + , H - , O - , and OH x - ion species from an Li–O–H surface for H, D, He, Ne, and Ar ion irradiation at 45° incidence in the energy range of 30–2000 eV. A Li film was deposited on a stainless steel target using Li evaporators in the LTX-β vessel, using the LTX-β Sample Exposure Probe (SEP), which includes an ultrahigh vacuum suitcase for transferring targets without significant contamination from air exposure. The SEP was used to transfer the Li-coated target from LTX-β to a separate Sample Exposure Station (SES) to perform ion exposure measurements. The SEP was also used for characterization of the Li-coated target utilizing X-ray photoelectron spectroscopy in a different chamber, showing that the lithium film surface was oxidized. Ion exposures were performed using an electron cyclotron resonance plasma source in the SES. Sputtered/ejected species were sampled by a quadrupole mass spectrometer with capabilities for detecting positive and negative ions, and an energy filter for determining the mean kinetic energy of the ejected ion species. All ion irradiations caused Li + ions to be ejected, while causing impurity ions such as H + , H - , O - and OH - to be ejected. Measured ion energies of Li + ions from a Li–O–H surface suggested that the typical sheath potential on the divertor surface can trap sputtered Li + ions, which were previously reported as ~ 60% of total sputtered Li species from Li targets (Allain and Ruzic in Nucl Fusion 42:202, 2002). Hence, our results for the sputtering yields of ejected ion species and their associated ion energies from a Li–O–H surface indicates that lithium sputtering is suppressed and impurity removal is enhanced due to the sheath potential at the divertor surface for fusion reactor applications.

Plasma-material interaction↗

The electrical power subsystem of the Pioneer F/G spacecraft.

The Pioneer F/G spacecraft is the first to use radioisotope thermoelectric generators (RTG's) for a long duration interplanetary mission. This paper describes the design of the spacecraft power subsystem which meets the unique requirements of such a mission. The primary power source consists of four SNAP 19 RTG's. The 4.2 volt dc outputs of the RTG's are inverted to higher voltage ac by four inverters which are connected in parallel at their outputs. A power control unit (PCU) regulates the ac output of the inverters such that the RTG's are operated at near maximum power voltage throughout the mission. The PCU also contains charge and discharge controls for a silver cadmium battery which supplements the RTG's if load requirements temporarily exceed RTG power output. Battery reliability is enhanced by overcharge and cell reversal protection electronics which are provided for each cell. Multiple, low voltage, regulated dc outputs which supply power to the spacecraft subsystems are provided by a central transformer-rectifier-filter unit (CTRF). The CTRF operates directly from the regulated ac bus.

Reppucci, G. M.↗

Magnetic and electric field meters developed for the US Department of Energy

This report describes work done at the Jet Propulsion Laboratory for the Office of Energy Storage and Distribution of DOE on the measurement of power line fields. A magnetic field meter is discussed that uses fiber optics to couple a small measuring probe to a remote readout device. The use of fiber optics minimizes electric field perturbation due to the presence of the probe and provides electric isolation for the probe, so that it could be used in a high field or high voltage environment. Power to operate the sensor electronics is transferred via an optical fiber, and converted to electrical form by a small photodiode array. The fundamental, the second and third harmonics of the field are filtered and separately measured, as well as the broadband rms level of the field. The design of the meter is described in detail and data from laboratory tests are presented. The report also describes work done to improve the performance of a DC bushing in a Swedish factory, using the improved meter. The DC electric fields are measured with synchronous detection to provide field magnitude data in two component directions.

Kirkham, H.↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An updated estimate of the Mu2e experiment sensitivity

The Mu2e experiment at Fermilab will search for the conversion of a negative muon into an electron inside the field of a nucleus. This process does not conserve charged-lepton flavour and is heavily suppressed in the Standard Model (SM), with a branching ratio < 10-50. Any evidence of it would be an undeniable evidence of new physics beyond the SM. The project sets out to achieve a single event sensitivity of $\sim 3 × 10^{-17}$ on the ratio between the probability for a conversion of a negative muon into an electron and the one for a muon capture by the nucleus. Such a sensitivity would represent a 4 orders of magnitude improvement on the previous upper limit for the process, making possible to test predictions of different extensions of the SM. Mu2e uses three superconducting solenoids to produce and measure the muon conversions. In the first solenoid, the Production Solenoid, pions and kaons are produced, together with other secondary products, by 8 GeV kinetic energy proton interactions in a tungsten target. A gradient magnetic field is specifically designed to direct low momentum particles into the Transport Solenoid, an S-shaped magnet that filters out particles with unwanted charge and momentum. Muons, produced by pion and kaon decays, finally reach the aluminum Stopping Target in the Detector Solenoid, where they eventually stop and convert. The result of the conversion process is a monochromatic electron of ~105 MeV/c momentum. The Detector Solenoid also hosts the two main detectors: a straw tube tracker and two CsI calorimeter disks, both providing measurement of event kinematics. A germanium detector and a LaBr crystal are located downstream of the Detector Solenoid to measure the X and gamma rays produced by the muon captures in the Stopping Target. A veto system of scintillators covering the Detector Solenoid and half of the Transport Solenoid is used to identify and reject cosmic rays interactions. With respect to the initial project, the Mu2e running plan has evolved to a staged configuration with 2 years at reduced intensity before the 2025 accelerator shutdown for the neutrino beam upgrade and 2 or 3 years at full intensity after that. This, together with geometry changes and a better knowledge of detector performances obtained by the first slice tests, has required a full revision of the signal over background selection that is the subject of this thesis. In order to achieve a new estimate of Mu2e sensitivity, the simulation of the data corresponding to the first 2 years of data acquisition has been performed. This includes both conversion electrons (CE) and the main sources of background: cosmics, decay-in orbits (DIO), radiative pion captures (RPC) and antiprotons. The characteristics of the signal and of the main backgrounds have been studied to define the best selection variables for CE. A special effort has been devoted to the evaluation of the antiproton background. The lack of experimental data for antiproton production cross section makes the systematic uncertainty on this background significant. A new parameterization of the cross section has been developed to fit the existing data and to provide a more reliable estimate of the systematic uncertainty by comparing the results of the old and the new model. A special effort has been devoted to the optimization of the antiprotons Monte Carlo generator. This study has also revealed that the dominant component within this background is represented by antiprotons produced in the opposite direction with respect to the Transport Solenoid entrance and then redirected to it by back-scattering processes in the Production Target. This ultimately highlights the sensitivity of the background estimate to the G4 handling of antiproton interactions in the 1 to 3 GeV/c momentum range. Finally, the final experimental sensitivity has been studied. The momentum and time selection have been optimized to obtain the 5-sigma discovery reach or, in case of no signal, the upper limit on conversion probability. The results confirm that, in the firs t two years of data taking, Mu2e will be able to improve the current experimental sensitivity for muon-to-electron conversion in an atomic field by more than 3 order of magnitudes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗