A TRANSMISSION ELECTRON MICROSCOPY STUDY OF PRESOLAR HIBONITE

We report isotopic and microstructural data on five presolar hibonite grains (KH1, KH2, KH6, KH15, and KH21) identified in an acid residue of the Krymka LL3.1 ordinary chondrite. Isotopic measurements by secondary ion mass spectrometry (SIMS) verified a presolar circumstellar origin for the grains. Transmission electron microscopy (TEM) examination of the crystal structure and chemistry of the grains was enabled by in situ sectioning and lift-out with a focused-ion-beam scanning-electron microscope (FIB-SEM). Comparisons of isotopic compositions with models indicate that four of the five grains formed in low-mass stars that evolved through the red giant/asymptotic giant branches (RGBs/AGBs), whereas one grain formed in the ejecta of a Type II supernova. Selected-area electron-diffraction patterns show that all grains are single crystals of hibonite. Some grains contain minor structural perturbations (stacking faults) and small spreads in orientation that can be attributed to a combination of growth defects and mechanical processing by grain-grain collisions. The similar structure of the supernova grain to those from RGB/AGB stars indicates a similarity in the formation conditions. Radiation damage (e.g., point defects), if present, occurs below our detection limit. Of the five grains we studied, only one has the pure hibonite composition of CaAl{sub 12}O{sub 19}. All others contain minor amounts of Mg, Si, Ti, and Fe. The microstructural data are generally consistent with theoretical predictions, which constrain the circumstellar condensation temperature to a range of 1480-1743 K, assuming a corresponding total gas pressure between 1 x 10{sup -6} and 1 x 10{sup -3} atm. The TEM data were also used to develop a calibration for SIMS determination of Ti contents in oxide grains. Grains with extreme {sup 18}O depletions, indicating deep mixing has occurred in their parent AGB stars, are slightly Ti enriched compared with grains from stars without deep mixing, most likely reflecting differences in grain condensation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Cross-Sectional Scanning Electron Microscopy of Perovskite Solar Cells

Organic–inorganic perovskites are an emerging class of photovoltaic materials. Despite achieving power conversion efficiencies surpassing 26%, the challenge of perovskite stability including degradation during exposure to operational conditions such as light, heat, humidity, water, oxygen, and electric fields is well known. Related, perovskite instability has limited high-resolution electron imaging and characterization techniques that can be used for understanding degradation mechanisms. Furthermore, we demonstrate perovskite device cross-section preparation using mechanical polishing in a water-free environment with cryogenic Ar ion milling. Scanning electron microscopy was then used in both backscattered electron and secondary electron imaging modes to obtain information about layer structure, grain aggregate structure, and compositional heterogeneity. Monte Carlo CASINO simulations inform optimum beam conditions and image acquisition parameters and the effects of accelerating voltage, dwell times, and frame averaging for practical image acquisition are reported.

14 SOLAR ENERGY↗

In Situ Transmission Electron Microscopy of Oxide Shell-Induced Pore Formation in (De)lithiated Silicon Nanowires

Silicon (Si) nanowires with a silicon oxide (SiOx) shell were observed in situ during lithiation and delithiation using transmission electron microscopy (TEM). The oxide shell constrains the volume expansion, which prevents full lithiation of the nanowire and retention of a crystalline Si core. Pores form in the amorphized silicon upon the first delithiation. We propose that this is caused by a high barrier to vacancy migration in the SiOx shell, which prevents vacancies formed during delithiation from transporting through the shell to the nanowire surface. These in situ studies demonstrate the importance of the direct observation of structural changes that occur in a material during cycling upon the addition of a coating.

Adkins, Emily R.↗

Efficient linear phase contrast in scanning transmission electron microscopy with matched illumination and detector interferometry

The ability to image light elements in soft matter at atomic resolution enables unprecedented insight into the structure and properties of molecular heterostructures and beam-sensitive nanomaterials. In this study, we introduce a scanning transmission electron microscopy technique combining a pre-specimen phase plate designed to produce a probe with structured phase with a high-speed direct electron detector to generate nearly linear contrast images with high efficiency. We demonstrate this method by using both experiment and simulation to simultaneously image the atomic-scale structure of weakly scattering amorphous carbon and strongly scattering gold nanoparticles. Our method demonstrates strong contrast for both materials, making it a promising candidate for structural determination of heterogeneous soft/hard matter samples even at low electron doses comparable to traditional phase-contrast transmission electron microscopy. Ultimately, simulated images demonstrate the extension of this technique to the challenging problem of structural determination of biological material at the surface of inorganic crystals.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Amyloid Structure and Assembly: Insights from Scanning Transmission Electron Microscopy

Amyloid fibrils are filamentous protein aggregates implicated in several common diseases such as Alzheimer's disease and type II diabetes. Similar structures are also the molecular principle of the infectious spongiform encephalopathies such as Creutzfeldt-Jakob disease in humans, scrapie in sheep, and of the so-called yeast prions, inherited non-chromosomal elements found in yeast and fungi. Scanning transmission electron microscopy (STEM) is often used to delineate the assembly mechanism and structural properties of amyloid aggregates. In this review we consider specifically contributions and limitations of STEM for the investigation of amyloid assembly pathways, fibril polymorphisms and structural models of amyloid fibrils. This type of microscopy provides the only method to directly measure the mass-per-length (MPL) of individual filaments. Made on both in vitro assembled and ex vivo samples, STEM mass measurements have illuminated the hierarchical relationships between amyloid fibrils and revealed that polymorphic fibrils and various globular oligomers can assemble simultaneously from a single polypeptide. The MPLs also impose strong constraints on possible packing schemes, assisting in molecular model building when combined with high-resolution methods like solid-state nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR).

59 BASIC BIOLOGICAL SCIENCES↗

Imaging ZnO Nanobelts and Nanobelt-Supported Metal Nanocatalysts by Aberration-Corrected Scanning Transmission Electron Microscopy

The development of aberration correctors and their routine applications in transmission and scanning transmission electron microscopy mode have enabled sub- ngstr m imaging of practical nanoscale materials and nanocatalysts. To correctly interpret the observed image contrast of practical samples is, however, still challenging. For example, the contrast of the various features in a high-angle annular dark-field (HA-ADF) image can be affected by many parameters such as sample tilt [1], presence of amorphous materials [2], overlapping crystallites, electron-beam channeling, etc. The visibility and image contrast of individual monomers, dimers or small clusters supported on relatively thick crystalline substrates may be modulated by tilting the substrate crystal away from electron-beam channeling conditions or the major zone axes.

aberration-corrected↗

High-Resolution Transmission Electron Microscopy on an Absolute Contrast Scale

A fully quantitative approach to high-resolution transmission electron microscopy requires a satisfactory match between image simulations and experiments. While almost perfect agreement between simulations and experiments is routinely achieved on a relative contrast level, a huge mutual discrepancy in the absolute image contrast by a factor of 3 has been frequently reported. It is shown that a major reason for this well-known contrast discrepancy, which is often called Stobbs-factor problem, lies in the neglect of the detector modulation-transfer function in image simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Structure Determination from Experimental Four-Dimensional Scanning Transmission Electron Microscopy via the Scattering Matrix

Considerable inroads have recently been made on algorithms to determine the sample potential from four-dimensional scanning transmission electron microscopy data from thick samples where multiple scattering cannot be neglected. This paper further develops the scattering matrix approach to such structure determination. Through simulation, we demonstrate how this approach can be modified to better handle partial spatial coherence, unknown probe defocus, and information from the dark field region. By combining these developments we reconstruct the electrostatic potential of a monolithic SrTiO 3 crystal showing good quantitative agreement with the expected structure.

4D STEM↗

Microfabricated high-bandpass foucault aperture for electron microscopy

A variant of the Foucault (knife-edge) aperture is disclosed that is designed to provide single-sideband (SSB) contrast at low spatial frequencies but retain conventional double-sideband (DSB) contrast at high spatial frequencies in transmission electron microscopy. The aperture includes a plate with an inner open area, a support extending from the plate at an edge of the open area, a half-circle feature mounted on the support and located at the center of the aperture open area. The radius of the half-circle portion of reciprocal space that is blocked by the aperture can be varied to suit the needs of electron microscopy investigation. The aperture is fabricated from conductive material which is preferably non-oxidizing, such as gold, for example.

47 OTHER INSTRUMENTATION↗

Histological preparation of developing vestibular otoconia for scanning electron microscopy

The unique nature of vestibular otoconia as calcium carbonate biominerals makes them particularly susceptible to chemical deformation during histological processing. We fixed and stored otoconia from all three otolith endorgans of embryonic, hatchling and adult Japanese quail in glutaraldehyde containing either phosphate or non-phosphate buffers for varying lengths of time and processed them for scanning electron microscopy. Otoconia from all age groups and otolith endorgans processed in 0.1 M phosphate buffer (pH 7.4) showed abnormal surface morphology when compared to acetone fixed controls. Otoconia processed in 0.1 M sodium cacodylate or HEPES buffered artificial endolymph (pH 7.4) showed normal morphology that was similar to controls. The degree of otoconial deformation was directly related to the time exposed to phosphate buffer. Short duration exposure produced particulate deformations while longer exposures resulted in fused otoconia that formed solid sheets. Otoconial surface deformation and fusing was independent of the glutaraldehyde component of the histological processing. These findings should help vestibular researchers to develop appropriate histological processing protocols in future studies of otoconia.

Non-NASA Center↗

Identification of interstratified mica and pyrophyllite monolayers within chlorite using advanced scanning/transmission electron microscopy

Interstratified clay minerals reflect the weathering degree and record climatic conditions and the pedogenic processes in the soil. It is hard to distinguish a few layers of interstratified clay minerals from the chlorite matrix, due to their similar two-dimensional tetrahedral-octahedral-tetrahedral (TOT) structure and electron-beam sensitive nature during transmission electron microscopy (TEM) imaging. In this study, we used multiple advanced TEM techniques including low-dose high-resolution TEM (HRTEM), high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) imaging combined with energy-dispersive spectroscopic (EDS) mapping to study interstratified layers in a chlorite sample from Changping, Beijing, China. We demonstrated an interstratified mica or pyrophyllite monolayer could be well distinguished from the chlorite matrix by projected atomic structures, lattice spacings, and chemical compositions with advanced TEM techniques. Further investigation showed two different transformation mechanisms from mica or pyrophyllite to chlorite: either a 4 A increase or decrease in the lattice spacing. Lastly, this characterization approach can be extended to the studies of other electron-beam sensitive minerals.

36 MATERIALS SCIENCE↗

Atomic‐Resolution Imaging of Halide Perovskites Using Electron Microscopy

Abstract Atomic‐resolution imaging of halide perovskites (HPs) using transmission electron microscopy (TEM) is challenging because of the sensitivity of their structures to the electron beam. In this article, recent achievements in this area are reviewed, covering both all‐inorganic and organic–inorganic hybrid HPs, with an emphasis on the specific imaging conditions that have proven to be effective in avoiding electron beam‐induced structural damage. The discussion focusses on the total electron dose that HPs can bear before being damaged and the effects of different imaging modes, accelerating voltages, and temperatures. The crucial role of a direct‐detection electron‐counting camera in reducing the required electron dose is outlined, which is indispensable for imaging extremely sensitive organic–inorganic hybrid perovskites. In addition to reviewing published works, the results of initial attempts to perform atomic‐resolution elemental mapping for an all‐inorganic HP and image a hybrid HP using scanning TEM are introduced. The preparation of a TEM specimen from macroscopic crystals or devices of HPs, which is very important for practical applications but has not yet received attention, is also discussed. This article aims to provide guidance on the acquisition of atomic‐resolution TEM images of HPs and inspire the development of more imaging technologies for sensitive materials.

Song, Kepeng↗

Correcting nonlinear drift distortion of scanning probe and scanning transmission electron microscopies from image pairs with orthogonal scan directions

Unwanted motion of the probe with respect to the sample is a ubiquitous problem in scanning probe and scanning transmission electron microscopies, causing both linear and nonlinear artifacts in experimental images. We have designed a procedure to correct these artifacts by using orthogonal scan pairs to align each measurement line-by-line along the slow scan direction, by fitting contrast variation along the lines. We demonstrate the accuracy of our algorithm on both synthetic and experimental data and provide an implementation of our method.

36 MATERIALS SCIENCE↗

Nanowire growth kinetics in aberration corrected environmental transmission electron microscopy

Here, we visualize atomic level dynamics during Si nanowire growth using aberration corrected environmental transmission electron microscopy, and compare with lower pressure results from ultra-high vacuum microscopy. We discuss the importance of higher pressure observations for understanding growth mechanisms and describe protocols to minimize effects of the higher pressure background gas.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Directly correlated transmission electron microscopy and atom probe tomography of grain boundary oxidation in a Ni-Al binary alloy exposed to high-temperature water

Intergranular oxidation of a Ni-4Al alloy exposed to hydrogenated, high-temperature water was characterized using directly correlated transmission electron microscopy and atom probe tomography. These combined analyses revealed that discrete, well-separated oxides (NiAl 2 O 4 ) precipitated along grain boundaries in the metal. Aluminum was depleted from the grain boundary between oxides and also from one side of the boundary as a result of grain boundary migration. The discrete oxide morphology, disconnected from the continuous surface oxidation, suggests intergranular solid-state internal oxidation of Al. Keywords: oxidation; grain boundaries; nickel alloys; atom probe tomography; transmission electron microscopy (TEM)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond time-resolved photoemission electron microscopy for spatiotemporal imaging of photogenerated carrier dynamics in semiconductors

We constructed an instrument for time-resolved photoemission electron microscopy (TR-PEEM) utilizing femtosecond (fs) laser pulses to visualize the dynamics of photogenerated electrons in semiconductors on ultrasmall and ultrafast scales. The spatial distribution of the excited electrons and their relaxation and/or recombination processes were imaged by the proposed TR-PEEM method with a spatial resolution about 100 nm and an ultrafast temporal resolution defined by the cross-correlation of the fs laser pulses (240 fs). A direct observation of the dynamical behavior of electrons on higher resistivity samples, such as semiconductors, by TR-PEEM has still been facing difficulties because of space and/or sample charging effects originating from the high photon flux of the ultrashort pulsed laser utilized for the photoemission process. Here, a regenerative amplified fs laser with a widely tunable repetition rate has been utilized, and with careful optimization of laser parameters, such as fluence and repetition rate, and consideration for carrier lifetimes, the electron dynamics in semiconductors were visualized. For demonstrating our newly developed TR-PEEM method, the photogenerated carrier lifetimes around a nanoscale defect on a GaAs surface were observed. The obtained lifetimes were on a sub-picosecond time scale, which is much shorter than the lifetimes of carriers observed in the non-defective surrounding regions. Our findings are consistent with the fact that structural defects induce mid-gap states in the forbidden band, and that the electrons captured in these states promptly relax into the ground state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Electron Microscopy Investigations of Structure and Morphology of Cadmium Selenide Nanocrystals

The paper presents high-resolution electron microscopy investigations of the structure and morphology of cadmium selenide nanocrystals and nanoplatelets, and nanoplatelets having cadmium selenide core/crown nanostructure. These nanocrystals and nanoplatelets are obtained by the colloid technology and are deposited onto carbon substrates using the Langmuir–Blodgett method. It is shown that two-dimensional structures of nanocrystals and nanoplatelets can be formed on carbon substrates. The quantity specifications of these structures are determined in this paper.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗