Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “efficient buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Assessing the Effectiveness of Generalized Likelihood Ratio Test Detector Schemes in Seismic Event Detection and the Avoidance of Nontarget Signals

Cross-correlation techniques have played a long-standing and pivotal role in seismic event monitoring. However, the performance of correlation-based detectors is challenged by nuisance seismicity, or nontarget signals. Such detections are a problem when the mission is to automatically map events to the correct source region. Using aftershocks of the 2014 $M_w$ 6.0 South Napa, California, earthquake, we demonstrate the effectiveness of utilizing a dynamic correlation processor framework in a generalized likelihood ratio test (GLRT) detector configuration to minimize nontarget detections. A GLRT maximizes a detection statistic with respect to one or more unknown parameters. In this case, the detection statistic is a template signal match against the waveform in a window sliding over a data stream, and the unknown parameter is an index variable indicating group membership of the template event or events. Detected events are assigned to the event group that yields the largest detection statistic. In this work, our results show that a GLRT detector will outperform a suite of independently operating correlation and subspace detectors in terms of having a lower nontarget detection rate at a given missed detection rate. We also show that a GLRT detector composed of a few high-rank subspace detectors has a slightly higher nontarget detection rate, but a significantly lower missed detection rate, than a GLRT detector composed of many low-rank subspace detectors. The high-rank GLRT configuration produced impressive results even with marginal data (single channel, single station, and very low time bandwidth product), which bodes well for the utility of building efficient aftershock classification systems and global monitoring systems at larger scales. However, future work is required to assess performance at the regional scale and to assess the performance of the system at detecting target events not used in the detector template creation.

58 GEOSCIENCES↗

EEBHub Navy Yard Sankey Diagram Energy Analysis Final Report

The Energy Efficient Buildings Hub (EEBHub) uses Sankey diagrams to visually analyze energy uses among buildings within the Navy Yard. This report describes the preliminary steps taken to incorporate multiple buildings in a district energy analysis, which can eventually be expanded to the Greater Philadelphia Region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

EEBHub Navy Yard Sankey Diagram Energy Analysis Final Report

The Energy Efficient Buildings Hub (EEBHub) uses Sankey diagrams to visually analyze energy uses among buildings within the Navy Yard. This report describes the preliminary steps taken to incorporate multiple buildings in a district energy analysis, which can eventually be expanded to the Greater Philadelphia Region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technoeconomic Evaluation of MEA versus Mixed Amines for CO 2 Removal at Near-Commercial Scale at Duke Energy Gibson 3 Plant

The US-China Clean Energy Research Center (CERC) was established in November 2009 by Presidents Obama and Hu. CERC is made up of three consortia focused on building efficiency, clean vehicles and advanced coal technologies. The Advanced Coal Technology Consortium (ACTC) brings together many of the top scientists and leading companies in the power sector, who work together collaboratively to accelerate deployment of the most promising technologies and tackle some of the most pressing issues in making coal plants more efficient and environmentally friendly. Reducing carbon emissions in the power sector is a central goal for both US and Chinese decision makers and industrial leaders, since, worldwide, coal power plants produce nearly 40% of greenhouse gases. In order to deeply reduce their greenhouse gas emissions, many utilities are considering carbon capture, utilization, and sequestration (CCUS). CCUS can enable the current fossil fuel infrastructure to be utilized while non-fossil fuel based energy supplies evolve to replace fossil fuels. For the existing US and Chinese coal-burning fleets, post-combustion capture (PCC) remains a critically important option and viable approach. While companies provide technology for PCC retrofits, the costs and performance of these systems remain largely untested in commercial settings. As such, power generation companies have very few technical or economic data sets on which to base large capital decisions. Moreover, initial estimates suggest the costs will prove prohibitively high in many settings.

20 FOSSIL-FUELED POWER PLANTS↗

EEB Hub Regional Sankey Diagram: Philadelphia Authority for Industrial Development Historical and Forecast Energy by Planned Use at the Philadelphia Navy Yard

The Energy Efficient Buildings Hub (EEB Hub) is a DOE-funded center, focused on improving the energy use in commercial and large-scale residential buildings. One of the Hub’s goals has been to develop the means and methods to reduce energy use in commercial buildings by 20 percent by 2020. Understanding energy use in buildings is a key component to managing energy use at multiple scales, from the building to the city, to the region. Sankey diagrams are an accessible tool to visualize energy flows, and help identify opportunities to deploy energy saving technologies. A campus-level Sankey diagram was previously generated from 2010-2011 data for ~100 metered Navy Yard buildings to quantify natural gas and electricity usage by principal building activity. As these properties are renovated, the energy consumption and building principal activities are being updated and modified. To depict the multi-year time lapse of regional electricity distribution in the Navy Yard, LLNL generated Sankey diagrams using data from 36 properties (buildings, developments, equipment) used to develop Philadelphia Authority for Industrial Development’s (PIDC) Navy Yard Master Energy Plan (NYEMP). The diagrams presented in this report depict ~10 building use types and the yearly changes in forecasted usage in GWh from 2011 to 2022. The forecast captures increases in regional energy use from planned building additions and renovations and yearly increases for existing buildings. From 2009 to 2022, there is approximately 5.6 million square feet of planned additions and renovations. The largest addition of properties are for office (~ 2.3 million square feet for dedicated office, and larger for shared office space) and residential space (~1 million square feet). Until 2014, the largest user of energy is for flex space, reaching a forecasted 11.4 GWh. In 2015-2016, the largest forecasted user is for a data center reaching ~25.7 GWh. After 2016, the largest consumers are either for office space (reaching 63.2 GWh forecast in 2022), or heavy industry (68 GWh forecast in 2022).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application of Spray Foam Insulation Under Plywood and Oriented Strand Board Roof Sheathing

Unvented roof strategies with open cell and closed cell spray polyurethane foam insulation sprayed to the underside of roof sheathing have been used since the mid-1990's to provide durable and efficient building enclosures. However, there have been isolated moisture related incidents reported anecdotally that raise potential concerns about the overall hygrothermal performance of these systems. The incidents related to rainwater leakage and condensation concerns. Condensation concerns have been extensively studied by others and are not further discussed in this report. This project involved hygrothermal modeling of a range of rainwater leakage and field evaluations of in-service residential roofs using spray foam insulation. All of the roof assemblies modeled exhibited drying capacity to handle minor rainwater leakage. All field evaluation locations of in-service residential roofs had moisture contents well within the safe range for wood-based sheathing. Explorations of eleven in-service roof systems were completed. The exploration involved taking a sample of spray foam from the underside of the roof sheathing, exposing the sheathing, then taking a moisture content reading. All locations had moisture contents well within the safe range for wood-based sheathing. One full-roof failure was reviewed, as an industry partner was involved with replacing structurally failed roof sheathing. In this case the manufacturer's investigation report concluded that the spray foam was installed on wet OSB based on the observation that the spray foam did not adhere well to the substrate and the pore structure of the closed cell spray foam at the ccSPF/OSB interface was indicative of a wet substrate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Spray Foam Insulation Under Plywood and OSB Roof Sheathing (Fact Sheet)

Spray polyurethane foams (SPFs) have advantages over alternative insulation methods because they provide air sealing in complex assemblies, particularly roofs. Spray foam can provide the thermal, air, and vapor control layers in both new and retrofit construction. Unvented roof strategies with open cell and closed cell SPF insulation sprayed to the underside of roof sheathing have been used since the mid-1990s to provide durable and efficient building enclosures. However, there have been isolated incidents of failures (either sheathing rot or SPF delamination) that raise some general concerns about the hygrothermal performance and durability of these systems. The primary risks for roof systems are rainwater leaks, condensation from diffusion and air leakage, and built-in construction moisture. This project directly investigated rain and indirectly investigated built-in construction moisture and vapor drives. Research involved both hygrothermal modeling of a range of rain water leakage scenarios and field evaluations of in-service residential roofs. Other variables considered were climate zone, orientation, interior relative humidity, and the vapor permeance of the coating applied to the interior face of open cell SPF.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart and Green Energy (SAGE) for Base Camps Final Report

The U.S. Army Logistics Innovation Agency’s (LIA’s) Smart and Green Energy (SAGE) for Base Camps project was to investigate how base camps’ fuel consumption can be reduced by 30% to 60% using commercial off-the-shelf (COTS) technologies for power generation, renewables, and energy efficient building systems. Field tests and calibrated energy models successfully demonstrated that the fuel reductions are achievable.

energy↗

Building Energy Benchmarking in India: an Action Plan for Advancing the State-of-the-Art

This document describes an action plan for advancing the state of the art of commercial building energy benchmarking in the Indian context. The document is primarily intended for two audiences: (a) Research and development (R&D) sponsors and researchers can use the action plan to frame, plan, prioritize and scope new energy benchmarking R&D in order to ensure that their research is market relevant; (b) Policy makers and program implementers engaged in the deployment of benchmarking and building efficiency rating programmes can use the action plan for policy formulation and enforcement .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Spray Foam Insulation Under Plywood and Oriented Strand Board Roof Sheathing

Unvented roof strategies with open cell and closed cell spray polyurethane foam insulation sprayed to the underside of roof sheathing have been used since the mid-1990's to provide durable and efficient building enclosures. However, there have been isolated moisture related incidents reported anecdotally that raise potential concerns about the overall hygrothermal performance of these systems. This project involved hygrothermal modeling of a range of rainwater leakage and field evaluations of in-service residential roofs using spray foam insulation. All of the roof assemblies modeled exhibited drying capacity to handle minor rainwater leakage. All field evaluation locations of in-service residential roofs had moisture contents well within the safe range for wood-based sheathing. Explorations of eleven in-service roof systems were completed. The exploration involved taking a sample of spray foam from the underside of the roof sheathing, exposing the sheathing, then taking a moisture content reading. All locations had moisture contents well within the safe range for wood-based sheathing. One full-roof failure was reviewed, as an industry partner was involved with replacing structurally failed roof sheathing. In this case the manufacturer's investigation report concluded that the spray foam was installed on wet OSB based on the observation that the spray foam did not adhere well to the substrate and the pore structure of the closed cell spray foam at the ccSPF/OSB interface was indicative of a wet substrate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Paths for the Yurok People

This Yurok Tribe energy strategic planning study examined electricity usage, costs and infrastructure, as well as electricity needs on the Reservation. It also assessed the Tribe’s energy resources. Equipped with this information, the project team conducted an energy options analysis that examined different project opportunities and identified key projects that are both feasible to implement and will help the Tribe reach its stated Energy Vision. A key finding of the energy needs assessment is that there are still numerous households that are without grid electric power, and it is likely that most of them will remain disconnected from the grid because of their remoteness. To provide these community members with reliable, affordable, modern energy services their homes will need to be electrified via a robust off-grid energy services program that installs and maintains off-grid energy systems. This is the key need that is explored and addressed in this plan. The approach taken is to establish a new business entity, a Tribal Energy Authority or Utility, that will operate a Tribal Energy Program. The Energy Strategic Plan identifies a number of potential funding sources that could be used to support both the On-grid and Off-grid Energy Programs. This plan also promotes continued efforts to reduce electricity consumption through the implementation of energy efficiency measures in existing facilities and the enforcement of a strong energy-efficient building code for all new construction on the Reservation. Finally, the plan promotes added resilience at critical Tribal facilities on the Reservation by recommending that battery energy storage systems and microgrid controls be coupled with rooftop solar PV systems to create cutting edge microgrid facilities that can provide critical power services to Tribal facilities when the main electric grid is shutdown.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Northwest — Advanced Grid Interactive Load Efficiency (AGILE) : A Techno-economic Assessment

The Advanced Grid Interactive Load Efficiency project team, led by Energy Northwest, was awarded funding as part of the fourth round of the Clean Energy Fund program to investigate, co-create, and complete a preliminary design for grid-interactive efficient buildings (GEBs) for a number of schools served by Grays Harbor PUD. The project team has evaluated different combinations of systems at selected school buildings and the potential to respond to grid and customer needs, and develop a preliminary system technical design, including specifying desired GEB technology options, determining communication and electrical interface requirements, assessing control software sensor requirements, and interfacing with building management systems. PNNL led the techno-economic assessment efforts, leveraging its advanced modeling and analytical methods and tools developed for building-to-grid integration. This report documents the economic assessment for different GEB design options, encompassing an in-depth examination of use cases and value propositions, assumptions and inputs, models, methods, case studies, as well as key findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nanoporous Wood Chips Based Sizable, Robust, and Low-Cost Honeycomb Vacuum Insulation Panels (DOE BENEFIT Final Research Performance Progress Report (RPPR))

Conventional vacuum insulation panels (VIPs) suffer from severe limitations including high cost, vulnerability to perforation, and significant performance degradation over time due to vacuum loss. InventWood Inc. (IW) and partnering teams completely re-engineered the VIP structure by constructing arrays of isolated vacuum-cells to enable limited cutting at designated areas (in between vacuum cells) and reduced consequential vacuum loss due to puncture. The teams also replaced the expensive vacuum insulation core materials with a low-cost commercial wood pulp and recycled long fiber. The wood pulp derived VIP can deliver an overall panel insulation of R15 (<0.01W/m·K) with over 90% thermal resistance retention after cutting (R13.5 overall, R5 along the cut edges). In addition, the vacuum-cell-array design minimizes edge losses, resulting in more durable performance, longer service life (>50 years), and higher R-value per dollar towards a cost target of <$1/ft 2 ·in. It is anticipated that the Nanochip-VIP will attract strong market interest and become an affordable insulation solution for energy efficient buildings and retrofits, leading to significant reductions in energy usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recycling Wind Energy Systems in the United States Part 1: Providing a Baseline for America's Wind Energy Recycling Infrastructure for Wind Turbines and Systems

The U.S. investments in building this new wind energy capacity will not only mobilize millions of tons of raw and processed materials in existing supply chains, some of which are critical materials, but also create new types and large volumes of end-of-life (EOL) waste streams. Building efficient, cost-effective, and environmentally responsible EOL management infrastructure of wind energy system components is pivotal in diverting upcoming volumes of waste stream from landfills, recovery of critical materials and reducing life cycle emissions from production of primary commodity materials . The primary goal of this report is to organize and communicate findings from this assessment on how alternate materials, designs and manufacturing processes could enable more efficient, cost-effective, and environmentally responsible disassembly and resource recovery from wind energy technologies. The findings of this assessment could inform prioritization of RD&D investment spending to meet Energy Act of 2020 directions. This assessment focused on key RD&D recommendations for three main temporal phases: Short-term (2023-2026), medium-term (2026 through 2035) and long-term (beyond 2035).

17 WIND ENERGY↗

Regulators’ Financial Toolbox: Virtual Power Plants Summary

On June 21, 2023, NARUC’s Center for Partnerships & Innovation (CPI) and the NASEO-NARUC GridInteractive Efficient Buildings (GEB) Working Group co-hosted a Regulators’ Financial Toolbox Webinar on the topic of virtual power plants (VPPs). The webinar featured opening remarks from moderator Commissioner Cecile Fraser of the Public Utilities Commission of Massachusetts and presentations from Ryan Hledik, Principal, The Brattle Group; Brenda Chew, Director of Product Management, Virtual Peaker; and Franco Albi, Director of Regional Integration, Portland General Electric.

24 POWER TRANSMISSION AND DISTRIBUTION↗