Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distance measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Noninvasive measurement of pulsatile intracranial pressure using ultrasound

The present study was designed to validate our noninvasive ultrasonic technique (pulse phase locked loop: PPLL) for measuring intracranial pressure (ICP) waveforms. The technique is based upon detecting skull movements which are known to occur in conjunction with altered intracranial pressure. In bench model studies, PPLL output was highly correlated with changes in the distance between a transducer and a reflecting target (R2 = 0.977). In cadaver studies, transcranial distance was measured while pulsations of ICP (amplitudes of zero to 10 mmHg) were generated by rhythmic injections of saline. Frequency analyses (fast Fourier transformation) clearly demonstrate the correspondence between the PPLL output and ICP pulse cycles. Although theoretically there is a slight possibility that changes in the PPLL output are caused by changes in the ultrasonic velocity of brain tissue, the decreased amplitudes of the PPLL output as the external compression of the head was increased indicates that the PPLL output represents substantial skull movement associated with altered ICP. In conclusion, the ultrasound device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. Our technique makes it possible to analyze ICP waveforms noninvasively and will be helpful for understanding intracranial compliance and cerebrovascular circulation.

NASA Center ARC↗

CubeSat Laser Infrared CrosslinK (CLICK): A Demonstration of Flexible High-Data-Rate, Low-Cost, Full-Duplex CubeSat Optical Communications and Ranging Capability

The CubeSat Laser Infrared CrosslinK (CLICK) mission will demonstrate technology to advance the state of the art in communications between small spacecraft as well as the capability to gauge their relative distance and location. CLICK is comprised of two sequential missions. The goal of CLICK B/C (i.e. CLICK B and CLICK C), the second mission shown in this animation, is to demonstrate full-duplex (send and receive) optical communication crosslink between two 3U (3-Unit CubeSats) small spacecraft, in low-Earth-orbit, at distances between 15 and 360 miles (25 to 580 kilometers) apart at data rates greater than 20 megabits per second. This second mission will also demonstrate precision ranging capability between the spacecraft that provides the ability to measure the distance and location of each with a range resolution to within approximately 20 inches (0.5 meters).

Mayer, David J.↗

Dispersed Fringe Sensing Analysis - DFSA

Dispersed Fringe Sensing (DFS) is a technique for measuring and phasing segmented telescope mirrors using a dispersed broadband light image. DFS is capable of breaking the monochromatic light ambiguity, measuring absolute piston errors between segments of large segmented primary mirrors to tens of nanometers accuracy over a range of 100 micrometers or more. The DFSA software tool analyzes DFS images to extract DFS encoded segment piston errors, which can be used to measure piston distances between primary mirror segments of ground and space telescopes. This information is necessary to control mirror segments to establish a smooth, continuous primary figure needed to achieve high optical quality. The DFSA tool is versatile, allowing precise piston measurements from a variety of different optical configurations. DFSA technology may be used for measuring wavefront pistons from sub-apertures defined by adjacent segments (such as Keck Telescope), or from separated sub-apertures used for testing large optical systems (such as sub-aperture wavefront testing for large primary mirrors using auto-collimating flats). An experimental demonstration of the coarse-phasing technology with verification of DFSA was performed at the Keck Telescope. DFSA includes image processing, wavelength and source spectral calibration, fringe extraction line determination, dispersed fringe analysis, and wavefront piston sign determination. The code is robust against internal optical system aberrations and against spectral variations of the source. In addition to the DFSA tool, the software package contains a simple but sophisticated MATLAB model to generate dispersed fringe images of optical system configurations in order to quickly estimate the coarse phasing performance given the optical and operational design requirements. Combining MATLAB (a high-level language and interactive environment developed by MathWorks), MACOS (JPL s software package for Modeling and Analysis for Controlled Optical Systems), and DFSA provides a unique optical development, modeling and analysis package to study current and future approaches to coarse phasing controlled segmented optical systems.

Sigrist, Norbert↗

Digital Averaging Phasemeter for Heterodyne Interferometry

A digital averaging phasemeter has been built for measuring the difference between the phases of the unknown and reference heterodyne signals in a heterodyne laser interferometer. This phasemeter performs well enough to enable interferometric measurements of distance with accuracy of the order of 100 pm and with the ability to track distance as it changes at a speed of as much as 50 cm/s. This phasemeter is unique in that it is a single, integral system capable of performing three major functions that, heretofore, have been performed by separate systems: (1) measurement of the fractional-cycle phase difference, (2) counting of multiple cycles of phase change, and (3) averaging of phase measurements over multiple cycles for improved resolution. This phasemeter also offers the advantage of making repeated measurements at a high rate: the phase is measured on every heterodyne cycle. Thus, for example, in measuring the relative phase of two signals having a heterodyne frequency of 10 kHz, the phasemeter would accumulate 10,000 measurements per second. At this high measurement rate, an accurate average phase determination can be made more quickly than is possible at a lower rate.

Johnson, Donald↗

Epidural anesthesia needle guidance by forward-view endoscopic optical coherence tomography and deep learning

Epidural anesthesia requires injection of anesthetic into the epidural space in the spine. Accurate placement of the epidural needle is a major challenge. To address this, we developed a forward-view endoscopic optical coherence tomography (OCT) system for real-time imaging of the tissue in front of the needle tip during the puncture. We tested this OCT system in porcine backbones and developed a set of deep learning models to automatically process the imaging data for needle localization. A series of binary classification models were developed to recognize the five layers of the backbone, including fat, interspinous ligament, ligamentum flavum, epidural space, and spinal cord. The classification models provided an average classification accuracy of 96.65%. During puncture, it is important to maintain a safe distance between the needle tip and the dura mater. Regression models were developed to estimate that distance based on the OCT imaging data. Based on the Inception architecture, our models achieved a mean absolute percentage error of 3.05% ± 0.55%. Overall, our results validated the technical feasibility of using this novel imaging strategy to automatically recognize different tissue structures and measure the distances ahead of the needle tip during the epidural needle placement.

60 APPLIED LIFE SCIENCES↗

The airborne laser ranging system, its capabilities and applications

The airborne laser ranging system is a multibeam short pulse laser ranging system on board an aircraft. It simultaneously measures the distances between the aircraft and six laser retroreflectors (targets) deployed on the Earth's surface. The system can interrogate over 100 targets distributed over an area of 25,000 sq, kilometers in a matter of hours. Potentially, a total of 1.3 million individual range measurements can be made in a six hour flight. The precision of these range measurements is approximately + or - 1 cm. These measurements are used in procedure which is basically an extension of trilateration techniques to derive the intersite vector between the laser ground targets. By repeating the estimation of the intersite vector, strain and strain rate errors can be estimated. These quantities are essential for crustal dynamic studies which include determination and monitoring of regional strain in the vicinity of active fault zones, land subsidence, and edifice building preceding volcanic eruptions.

Kahn, W. D.↗

Space-Based Lidar Systems

An overview of space-based lidar systems is presented. from the first laser altimeter on APOLLO 15 mission in 1971 to the Mercury Laser Altimeter on MESSENGER mission currently in orbit, and those currently under development. Lidar, which stands for Light Detection And Ranging, is a powerful tool in remote sensing from space. Compared to radars, lidars operate at a much shorter wavelength with a much narrower beam and much smaller transmitter and receiver. Compared to passive remote sensing instruments. lidars carry their own light sources and can continue measuring day and night. and over polar regions. There are mainly two types of lidars depending on the types of measurements. lidars that are designed to measure the distance and properties of hard targets are often called laser rangers or laser altimeters. They are used to obtain the surface elevation and global shape of a planet from the laser pulse time-of-night and the spacecraft orbit position. lidars that are designed to measure the backscattering and absorption of a volume scatter, such as clouds and aerosols, are often just called lidars and categorized by their measurements. such as cloud and aerosol lidar, wind lidar, CO2 lidar, and so on. The advantages of space-based lidar systems over ground based lidars are the abilities of global coverage and continuous measurements.

Sun, Xiaoli↗

How the Galaxy–Halo Connection Depends on Large-scale Environment

We investigate the connection between galaxies, dark matter halos, and their large-scale environments at z = 0 with Illustris TNG300 hydrodynamic simulation data. We predict stellar masses from subhalo properties to test two types of machine learning (ML) models: explainable boosting machines (EBMs) with simple galaxy environment features and E(3)-invariant graph neural networks (GNNs). The best-performing EBM models leverage spherically averaged overdensity features on 3 Mpc scales. Interpretations via SHapley Additive exPlanations also suggest that in the context of the TNG300 galaxy–halo connection, simple spherical overdensity on ∼3 Mpc scales is more important than cosmic web distance features measured using the DisPerSE algorithm. Meanwhile, a GNN with connectivity defined by a fixed linking length, L, outperforms the EBM models by a significant margin. As we increase the linking length scale, GNNs learn important environmental contributions up to the largest scales we probe (L = 10 Mpc). We conclude that 3 Mpc distance scales are most critical for describing the TNG galaxy–halo connection using the spherical overdensity parameterization, but that information on larger scales, which is not captured by simple environmental parameters or cosmic web features, can further augment these models. Our study highlights the benefits of using interpretable ML algorithms to explain models of astrophysical phenomena, and the power of using GNNs to flexibly learn complex relationships directly from data while imposing constraints from physical symmetries.

79 ASTRONOMY AND ASTROPHYSICS↗

Good Vibrations

A Small Business Innovation Research (SBIR) sponsorship from NASA's Dryden Flight Research Center, assisted MetroLaser, of Irvine, California, in the development of a self-aligned laser vibrometer system. VibroMet, capable of measuring surface vibrations in a variety of industries, provides information on the structural integrity and acoustical characteristics of manufactured products. This low-cost, easy-to-use sensor performs vibration measurement from distances of up to three meters without the need for adjustment. The laser beam is simply pointed at the target and the system then uses a compact laser diode to illuminate the surface and to subsequently analyze the reflected light. The motion of the surface results in a Doppler shift that is measured with very high precision. VibroMet is considered one of the many behind-the-scenes tools that can be relied on to assure the quality, reliability and safety of everything from airplane panels to disk brakes

Source record↗

Development of a Heterogeneous sUAS High-Accuracy Positional Flight Data Acquisition System

Recently, a heterogeneous FDAS, consisting of a diverse range of instruments was developed to support acoustic flight research programs at NASA Langley Research Center. In addition to a conventional GPS to measure latitude, longitude and altitude, the FDAS also utilizes a small, light-weight, low-cost DGPS system to obtain centimeter accuracy to measure the distance traveled by sound from a sUAS vehicle to a microphone on the ground. Acoustic flight testing using the FDAS installed on several different sUAS platforms has been conducted in support of the NASA CAS DELIVER and ERA ITD projects (Reference 1). The first FDAS prototype was assembled and implemented in the acoustic/flight measurement system in December 2014 to support DELIVER acoustic flight tests. Evaluation of the system performance and results from the data analyses were used to further test, develop and enhance the FDAS over a six-month period to support acoustic flight research for the ERA.

McSwain, Robert G.↗

Adaptive variational quantum dynamics simulations with compressed circuits and fewer measurements

The adaptive variational quantum dynamics simulation (AVQDS) method performs real-time evolution of quantum states using automatically generated parametrized quantum circuits that often contain substantially fewer gates than Trotter circuits. Here we report an improved version of the method, which we call AVQDS(T), by porting the tiling efficient trial circuits with rotations implemented simultaneously technique. The algorithm adaptively adds layers of disjoint unitary gates to the ansatz circuit so as to keep the McLachlan distance, a measure of the accuracy of the variational dynamics, below a fixed threshold. Here we perform benchmark noiseless AVQDS(T) simulations of quench dynamics in local spin models and compare with an alternative adaptive variational approach on quantum resource requirement. Quantum dynamical simulations implementing realistic noise channels are also reported. Finally, we propose a way to substantially alleviate the measurement overhead of AVQDS(T) while maintaining high accuracy by synergistically integrating quantum circuit calculations on quantum processing units with classical calculations using, e.g., tensor networks to evaluate the quantum geometric tensor. We showcase that this approach enables AVQDS(T) to deliver more accurate results than simulations using a fixed ansatz of comparable final depth for a significant time duration with fewer quantum resources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Airborne Laser Ranging System - Its capabilities and applications

The Airborne Laser Ranging System is a proposed multibeam short pulse laser ranging system on board an aircraft. It simultaneously measures the distances between the aircraft and six laser retroreflectors (targets) deployed on the earth's surface. Depending on the host aircraft and terrain characteristics, the system can interrogate hundreds of targets distributed over an area as large as 60,000 sq. km in a matter of hours. Potentially, a total of 1.3 million individual range measurements can be made in a 6 hr flight. The precision of these range measurements is approximately 1 cm. These measurements are then used in a procedure which is basically an extension of trilateration techniques to derive the intersite vector between the laser ground targets. By repeating the estimation of the intersite vector, strain and strain rate errors can be estimated. These quantities are essential for crustal dynamic studies which include determination and monitoring of regional strain in the vicinity of active fault zones, land subsidence, and edifice building preceding volcanic eruptions.

Kahn, W. D.↗

Shuttle Laser Altimeter (SLA): A pathfinder for space-based laser altimetry and lidar

The Shuttle Laser Altimeter (SLA) is a Hitchhiker experiment now being integrated for first flight on STS-72 in November 1995. Four Shuttle flights of the SLA are planned at a rate of about a flight every 18 months. They are aimed at the transition of the Goddard Space Flight Center airborne laser altimeter and lidar technology to low Earth orbit as a pathfinder for operational space-based laser remote sensing devices. Future alser altimeter sensors such as the Geoscience Laser Altimeter System (GLAS), an Earth Observing System facility instrument, and the Multi-Beam Laser Altimeter (MBLA), the land and vegetation laser altimeter for the NASA TOPSAT (Topography Satellite) Mission, will utilize systems and approaches being tested with SLA. The SLA Instrument measures the distance from the Space Shuttle to the Earth's surface by timing the two-way propagation of short (approximately 10 na noseconds) laser pulses. laser pulses at 1064 nm wavelength are generated in a laser transmitter and are detected by a telescope equipped with a silicon avalanche photodiode detector. The SLA data system makes the pulse time interval measurement to a precision of about 10 nsec and also records the temporal shape of the laser echo from the Earth's surface for interpretation of surface height distribution within the 100 m diam. sensor footprint. For example, tree height can be determined by measuring the characteristic double-pulse signature that results from a separation in time of laser backscatter from tree canopies and the underlying ground. This is accomplished with a pulse waveform digitizer that samples the detector output with an adjustable resolution of 2 nanoseconds or wider intervals in a 100 sample window centered on the return pulse echo. The digitizer makes the SLA into a high resolution surface lidar sensor. It can also be used for cloud and atmospheric aerosol lidar measurements by lengthening the sampling window and degrading the waveform resolution. Detailed test objectives for the STS-72 mission center on the acquisition of sample data sets for land topography and vegetation height, waveform digitizer performance, and verification of data acquisition algorithms. The operational concept of SLA is illustrated in Fig. 1 where a series of 100 m footprints stretch in a profile of Earth surface topography along the nadir track of the Space Shuttle. The location of SLA as a dual canister payload on the Hitchhiker Bridge Assembly in Bay 12 of the Space Shuttle Endeavor can also be noted in this figure. Full interpretation of the SLA range measurement data set requires a 1 m knowledge of the Orbiter trajectory and better than 0.1 deg knowledge of Orbiter pointing angle. These ancillary data sets will be acquired during the STS-72 mission with an on-board Global Positioning System (GPS) receiver, K-band range and range-rate tracking of the Orbiter through TDRSS, and use of on-board inertial measurement units and star trackers. Integration and interpretation of all these different data sets as a pathfinder investigation for accurate determination of Earth surface elevation is the overall science of the SLA investigation.

Bufton, Jack↗

The comet rendezvous asteroid flyby mission: A status report

The Comet Rendezvous Asteroid Flyby (CRAF) mission received a new start in fiscal year 1990. CRAF will match orbits with an active short-period comet and follow it around the Sun, making scientific measurements of the nucleus, coma, and tail. The Imaging system will map the nucleus surface at a resolution of 1 meter/line-pair or better, while Visible and Infrared Mapping Spectrometer (VIMS) and Thermal Infrared Radiometer Experiment (TIREX) will produce spectral and thermal maps of the surface. Onboard instruments will collect cometary dust, ice, and gases and perform elemental and molecular analysis. A suite of fields and particles instruments will observe the solar wind interaction with the cometary atmosphere and tail. Radio tracking of the spacecraft will provide an accurate measure of the nucleus mass and higher harmonics in the comet's gravity field. En route to the comet, the spacecraft will make a close flyby of a large asteroid, preferably a primitive type from the outer main belt. Observations at the asteroid include remote sensing mapping of the surface, detection of any solar wind interaction observable at the flyby distance, and measurement of the asteroid mass to better than 10 percent accuracy. Detailed design of the CRAF spacecraft is currently underway at the Jet Propulsion Laboratory (JPL). Recent mass growth has necessitated a switch to Venus-Earth gravity assist type trajectories, similar to that used by the Galileo spacecraft. These trajectories require longer flight times from launch to rendezvous with the target comet. The details of the current baseline mission, spacecraft design, and instrument payload will be reviewed.

Weissman, Paul R.↗

Effects of voluntary eye movement and convergence on the binocular appreciation of depth.

Scaling techniques were employed to establish the relation between perceived distance ratio and physical distance ratio. Measurements were made both with and without free eye movement and under two states of convergence. The results were confirmed using a matching technique. With free eye movement, the perceived ratio is a monotonic increasing function of the physical ratio. Without eye movement, the perceived ratio generally increases, then decreases, as the physical ratio increases. For a given physical ratio, perceived distance ratio is less in the absence of voluntary eye movements. Convergence produces depth micropsia when eye movements are permitted, but not in their absence.

Foley, J. M.↗

2D CFD of lean premixed hydrogen–air flame quenching under locomotive engine conditions

Hydrogen (H 2 ) is a promising fuel for reducing emissions in heavy-duty internal combustion engines (ICEs), but its low quenching distance increases the risk of flame propagation into narrow crevice regions, such as piston-liner gaps. This work uses detailed CFD simulations with finite-rate chemistry to investigate premixed H 2 –air flame quenching in a two-dimensional (2D) region consistent with the piston-liner gap of a diesel ICE. Model accuracy was assessed by comparison with experimentally measured quenching distances in an annular stepwise diverging tube (ASDT). A parametric study was conducted to assess the influence of crevice width (0.05–1.18 mm), pressure (50–150 bar), unburned gas temperature (431–573 K), and equivalence ratio ( Φ= 0.3–0.6). Results show that the critical Péclet number for flame survival is no greater than 3.25, consistent with prior literature, even under ultra-lean and high-pressure conditions (Φ ≤ 0.3, > 50 bar). Additionally, flames with Péclet numbers exceeding 6.15 exhibited front wrinkling, suggesting the onset of velocity-driven instabilities and enhanced flame robustness. These findings help define thresholds for flame quenching in confined geometries and support the safe design of H 2 fueled ICEs.

08 HYDROGEN↗

Proton and neutron contributions to the quadrupole transition strengths in 39 Ca and 39 K studied by lifetime measurements of mirror transitions

The E2 transition matrix elements of isobaric multiplets are expected to follow a linear trend as a function of isospin projection. However, measurements of the 2 + → 0 + transitions in the A = 38 triplet of Ca, K, and Ar show a deviation from this trend with an enhanced transition strength in 38 Ca with respect to its mirror 38 Ar. We have studied analogue 11/2 – → 7/2 – E2 transitions in 39 Ca and its mirror partner 39 K to determine if this enhancement persists in neighboring Ca isotopes. Recoil-distance lifetime measurements of 39 Ca and 39 K were performed utilizing a 42 Sc secondary beam, the TRIPLEX plunger, the GRETINA array, and the S800 spectrograph. Our data provide a lifetime measurement of the (11/2 – ) state in 39 Ca as well as an improved lifetime result for the (9/2 – ) state, while the 39 K data are used to validate the present analysis. Furthermore, a comparison of the present data to shell-model calculations suggests an enhanced transition strength in 39 Ca, pointing to both proton and neutron contributions to core excitations across the Z = N = 20 shell gaps in close proximity to 40 Ca.

39 ≤ A ≤ 58↗

Use of Tracer Elements for Estimating Community Exposure to Marcellus Shale Development Operations

Since 2009, unconventional natural gas development (UNGD) has significantly increased in Appalachia’s Marcellus Shale formation. Elevations of fine particulate matter <2.5 µm (PM2.5), have been documented in areas surrounding drilling operations during well stimulation. Furthermore, many communities are experiencing increased industrial activities and probable UNGD air pollutant exposures. Recent studies have associated UNGD emissions with health effects based on distances from well pads. In this study, PM2.5 filter samples were collected on an active gas well pad in Morgantown, West Virginia, and three locations downwind during hydraulic stimulation. Fine particulate samples were analyzed for major and trace elements. An experimental source identification model was developed to determine which elements appeared to be traceable downwind of the UNGD site and whether these elements corresponded to PM2.5 measurements. Results suggest that 1) magnesium may be useful for detecting the reach of UNGD point source emissions, 2) complex surface topographic and meteorological conditions in the Marcellus Shale region could be modeled and confounding sources discounted, and 3) well pad emissions may be measurable at distances of at least 7 km. If shown to be more widely applicable, future tracer studies could enhance epidemiological studies showing health effects of UNGD-associated emissions at ≥15 km.

60 APPLIED LIFE SCIENCES↗