Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “discrimination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Perceptual Classification Images from Vernier Acuity Masked by Noise

Letting external noise rather than internal noise limit discrimination performance allows information to be extracted about the observer's stimulus classification rule. A perceptual classification image is the correlation over trials between the noise amplitude at a spatial location and the observer's responses. If, for example, the observer followed the rule of the ideal observer, the perceptual classification image would be an estimate of the ideal observer filter, the difference between the two unmasked images being discriminated. Perceptual classification images were estimated for a vernier discrimination task. The display screen had 48 pixels per degree horizontally and vertically. The no-offset image had a dark horizontal line of 4 pixels, a 1 pixel space, and 4 more dark pixels. Classification images were based on 1600 discrimination trials with the line contrast adjusted to keep the error rate near 25 percent. In the offset image, the second line was one pixel higher. Unlike the ideal observer filter (a horizontal dipole), the observer perceptual classification images are strongly oriented. Fourier transforms of the classification images had a peak amplitude near one cycle per degree and an orientation near 25 degrees. The spatial spread is much more than image blur predicts, and probably indicates the spatial position uncertainty in the task.

Ahumada, A. J.↗

Immunohistochemical detection of active transforming growth factor-beta in situ using engineered tissue

The biological activity of transforming growth factor-beta 1 (TGF-beta) is governed by dissociation from its latent complex. Immunohistochemical discrimination of active and latent TGF-beta could provide insight into TGF-beta activation in physiological and pathological processes. However, evaluation of immunoreactivity specificity in situ has been hindered by the lack of tissue in which TGF-beta status is known. To provide in situ analysis of antibodies to differentiate between these functional forms, we used xenografts of human tumor cells modified by transfection to overexpress latent TGF-beta or constitutively active TGF-beta. This comparison revealed that, whereas most antibodies did not differentiate between TGF-beta activation status, the immunoreactivity of some antibodies was activation dependent. Two widely used peptide antibodies to the amino-terminus of TGF-beta, LC(1-30) and CC(1-30) showed marked preferential immunoreactivity with active TGF-beta versus latent TGF-beta in cryosections. However, in formalin-fixed, paraffin-embedded tissue, discrimination of active TGF-beta by CC(1-30) was lost and immunoreactivity was distinctly extracellular, as previously reported for this antibody. Similar processing-dependent extracellular localization was found with a neutralizing antibody raised to recombinant TGF-beta. Antigen retrieval recovered cell-associated immunoreactivity of both antibodies. Two antibodies to peptides 78-109 showed mild to moderate preferential immunoreactivity with active TGF-beta only in paraffin sections. LC(1-30) was the only antibody tested that discriminated active from latent TGF-beta in both frozen and paraffin-embedded tissue. Thus, in situ discrimination of active versus latent TGF-beta depends on both the antibody and tissue preparation. We propose that tissues engineered to express a specific form of a given protein provide a physiological setting in which to evaluate antibody reactivity with specific functional forms of a protein.

NASA Discipline Radiation Health↗

X-ray Mapping of Terrestrial and Extraterrestrial Materials Using the Electron Microprobe

Lunar samples returned from the Apollo program motivated development of the Bence-Albee algorithm for the rapid and accurate analysis of lunar materials, and established interlaboratory comparability through its common use. In the analysis of mineral and rock fragments it became necessary to combine micro- and macroscopic analysis by coupling electron-probe microanalysis (EPMA) with automated stage point counting. A coarse grid that included several thousand points was used, and initially wavelength-dispersive (WDS) and later energydispersive (EDS) data were acquired at discrete stage points using approx. 5 sec count times. A approx 50 micrometer beam diameter was used for WDS and up to 500 micrometer beam diameter for EDS analysis. Average analyses of discretely sampled phases were coupled with the point count data to calculate the bulk composition using matrix algebra. Use of a defocused beam resulted in a contribution from multiple phases to each analytical point, and the analytical data were deconvolved relative to end-member phase chemistry on the fly. Impressive agreement was obtained between WDS and EDS measurements as well as comparison with bulk chemistry obtained by other methods. In the 30 years since these methods were developed, significant improvements in EPMA automation and computer processing have taken place. Digital beam control allows routine collection of x-ray maps by EDS, and stage mapping for WDS is conducted continuously at slew speed and incrementally by sampling at discrete points. Digital pulse processing in EDS systems has significantly increased the throughput for EDS mapping, and the ongoing development of Si-drift detector systems promises mapping capabilities rivaling WDS systems. Spectrum imaging allows a data cube of EDS spectra to be acquired and sophisticated processing of the original data is possible using matrix algebra techniques. The study of lunar and meteoritic materials includes the need to conveniently: (1) Characterize the sample at microscopic and macroscopic scales with relatively high sensitivity, (2) Determine the modal abundance of minerals, and (3) Identify and relocate discrete features of interest in terms of size and chemistry. The coupled substitution of cations in minerals can result in significant variation in mineral chemistry, but at similar average Z, leading to poor backscattered-electron (BSE) contrast discrimination of mineralogy. It is necessary to discriminate phase chemistry at both the trace element level and the major element level. To date, the WDS of microprobe systems is preferred for mapping due to high throughput and the ability to obtain the necessary intensity to discriminate phases at both trace and major element concentrations. It is desirable to produce fully quantitative compositional maps of geological materials, which requires the acquisition of k-ratio maps that are background and dead-time corrected, and which have been corrected by phi(delta z> or an equivalent algorithm at each pixel. To date, turnkey systems do not allow the acquisition of k-ratio maps and the rigorous correction in this manner. X-ray maps of a chondrule from the Ourique meteorite, and a comb-layered xenolith from the San Francisco volcanic field, have been analyzed and processed to extract phase information. The Ourique meteorite presents a challenge due to relatively low BSE contrast, and has been studied using spectrum imaging. X-ray maps for Si, Mg, and FeK(alpha) were used to produce RGB images. The xenolith sample contains sector-zoned augite, olivine, plagioclase, and basaltic glass. X-ray maps were processed using Lispix and ImageJ software to produce mineral phase maps. The x-ray maps for Mg, Ca, and Ti were used with traceback to generate binary images that were converted to RGB images. These approaches are successful in discriminating phases, but it is desirable to achieve the methods that were used on lunar samples 30 years ago on current microprobe systems. Curnt research includes x-ray mapping analysis of the Dalgety Downs chondrite by micro x-ray fluorescence and spectrum imaging, in collaboration with Kenny Witherspoon of IXRF Systems and Dale Newbury of NIST.

Carpenter, P.↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Evaluation of Rainfall-Snowfall Separation Performance in Remote Sensing Datasets

The first step to accurately measure global snowfall is to separate rainfall from snowfall correctly (i.e., precipitation phase discrimination). This study first evaluates the phase discrimination performance in four remote sensing datasets, including observations from ground radar, spaceborne radars, and spaceborne radiometer, relative to ground observations. Results show that the snowfall discrimination accuracy varies greatly among these datasets ranging from 42% to 96%, dependent on whether and how the temperature information are considered. For example, over half of the snowfall from the Global Precipitation Measurement Mission (GPM) spaceborne radar is actually rainfall at the surface since it detects snowfall in the air without considering the temperature information close to the surface. Second, we evaluate the discrimination performance using the temperature information from four reanalysis datasets. It is found that MERRA2 temperature close to the surface is colder than the other three datasets, leading to more rainfall being misclassified as snowfall.

Yalei You↗

Spatial covert attention increases contrast sensitivity across the CSF: support for signal enhancement

This study is the first to report the benefits of spatial covert attention on contrast sensitivity in a wide range of spatial frequencies when a target alone was presented in the absence of a local post-mask. We used a peripheral precue (a small circle indicating the target location) to explore the effects of covert spatial attention on contrast sensitivity as assessed by orientation discrimination (Experiments 1-4), detection (Experiments 2 and 3) and localization (Experiment 3) tasks. In all four experiments the target (a Gabor patch ranging in spatial frequency from 0.5 to 10 cpd) was presented alone in one of eight possible locations equidistant from fixation. Contrast sensitivity was consistently higher for peripherally- than for neutrally-cued trials, even though we eliminated variables (distracters, global masks, local masks, and location uncertainty) that are known to contribute to an external noise reduction explanation of attention. When observers were presented with vertical and horizontal Gabor patches an external noise reduction signal detection model accounted for the cueing benefit in a discrimination task (Experiment 1). However, such a model could not account for this benefit when location uncertainty was reduced, either by: (a) Increasing overall performance level (Experiment 2); (b) increasing stimulus contrast to enable fine discriminations of slightly tilted suprathreshold stimuli (Experiment 3); and (c) presenting a local post-mask (Experiment 4). Given that attentional benefits occurred under conditions that exclude all variables predicted by the external noise reduction model, these results support the signal enhancement model of attention.

Non-NASA Center↗

Assessment of a remote sensing-based model for predicting malaria transmission risk in villages of Chiapas, Mexico

A blind test of two remote sensing-based models for predicting adult populations of Anopheles albimanus in villages, an indicator of malaria transmission risk, was conducted in southern Chiapas, Mexico. One model was developed using a discriminant analysis approach, while the other was based on regression analysis. The models were developed in 1992 for an area around Tapachula, Chiapas, using Landsat Thematic Mapper (TM) satellite data and geographic information system functions. Using two remotely sensed landscape elements, the discriminant model was able to successfully distinguish between villages with high and low An. albimanus abundance with an overall accuracy of 90%. To test the predictive capability of the models, multitemporal TM data were used to generate a landscape map of the Huixtla area, northwest of Tapachula, where the models were used to predict risk for 40 villages. The resulting predictions were not disclosed until the end of the test. Independently, An. albimanus abundance data were collected in the 40 randomly selected villages for which the predictions had been made. These data were subsequently used to assess the models' accuracies. The discriminant model accurately predicted 79% of the high-abundance villages and 50% of the low-abundance villages, for an overall accuracy of 70%. The regression model correctly identified seven of the 10 villages with the highest mosquito abundance. This test demonstrated that remote sensing-based models generated for one area can be used successfully in another, comparable area.

Insect Vectors/growth & development↗

An optimized index of human cardiovascular adaptation to simulated weightlessness

Prolonged exposure to weightlessness is known to produce a variety of cardiovascular changes, some of which may influence the astronaut's performance during a mission. In order to find a reliable indicator of cardiovascular adaptation to weightlessness, we analyzed data from nine male subjects after a 24-hour period of normal activity and after a period of simulated weightlessness produced by two hours in a launch position followed by 20 hours of 6 degrees head-down tilt plus pharmacologically induced diuresis (furosemide). Heart rate, arterial pressure, thoracic fluid index, and radial flow were analyzed. Autoregressive spectral estimation and decomposition were used to obtain the spectral components of each variable from the subjects in the supine position during pre- and post-simulated weightlessness. We found a significant decrease in heart rate power and an increase in thoracic fluid index power in the high frequency region (0.2-0.45 Hz) and significant increases in radial flow and arterial pressure powers in the low frequency region (<0.2 Hz) in response to simulated weightlessness. However, due to the variability among subjects, any single variable appeared limited as a dependable index of cardiovascular adaptation to weightlessness. The backward elimination algorithm was then used to select the best discriminatory features from these spectral components. Fisher's linear discriminant and Bayes' quadratic discriminant were used to combine the selected features to obtain an optimal index of adaptation to simulated weightlessness. Results showed that both techniques provided improved discriminant performance over any single variable and thus have the potential for use as an index to track adaptation and prescribe countermeasures to the effects of weightlessness.

NASA Discipline Number 14-10↗

Soft X-ray astronomy proportional counter electronics

The X-ray multiwire proportional counter is designed to measure cosmic X-ray fluxes at sounding rocket altitudes in the energy range of 0.1 to 10 keV. Four instruments will be launched in a Black Brant 4 rocket employing different combinations of detector windows and gas. The detector is constructed with two layers of twelve cells. A columnator is mounted on the face of one layer whose cells are wired together alternately to form two main detector sections. The electronics and gas regulation systems are mounted on the face of the second layer whose cells are wired together to form one anticoincidence detector section. Normally X-rays will have short ionization paths in only one of the main detector cells at a time and won't enter the anticoincidence detector cells. To distinguish between X-rays and charged particles, the instrument includes a coincidence discriminator, an anticoincidence discriminator, and a pulse rise time discriminator.

Gardner, W. R.↗

Calibration of the electron-proton spectrometer

The principal function of the sensor used in the electron-proton spectrometer is to provide a signal which can be used to determine the energy and indicate the type of an incident particle. Two techniques are employed to resolve the particle intensity in different energy regions. The first employs a moderator surrounding each detector to provide a nominal lower limit to the energy of a particle which can be detected. The second technique utilizes a pulse height discriminator to identify those particles entering a detector whose energy is (1) sufficiently high that it exceeds the discriminator level if the particle is stopped in the detector, or (2) sufficiently low that the ionization rate causes the discrimination level to be exceeded for paths through the detector shorter than the particle range.

Cash, B. L.↗

Geologic information from satellite images

The author has identified the following significant results. Extracting geologic information from ERTS and Skylab/EREP images is best done by a geologist trained in photointerpretation. The information is at a regional scale, and three basic types are available: rock and soil, geologic structures, and landforms. Discrimination between alluvium and sedimentary or crystalline bedrock, and between units in thick sedimentary sequences is best, primarily because of topographic expression and vegetation differences. Discrimination between crystalline rock types is poor. Folds and fractures are the best displayed geologic features. They are recognizable by topographic expression, drainage patterns, and rock or vegetation tonal patterns. Landforms are easily discriminated by their familar shapes and patterns. It is possible to optimize the scale, format, spectral bands, conditions of acquisition, and sensor systems for best geologic interpretation. Several examples demonstrate the applicability of satellite images to tectonic analysis and petroleum and mineral exploration.

Lee, K.↗

Task 60 test report, evaluation of IRIG-A 21 channel constant bandwith FM multiplexer for shuttle development flight instrumentation

A frequency modulated (FM) multiplexer, consisting of 21 IRIG-A constant bandwidth (CBW) voltage-controlled oscillators (VCO's) was tested to determine its suitability for use in multiplexing 21 data signals which have frequency ranges of dc to 2 kHz. Tests were preformed with the composite signal, consisting of the mixed outputs of the 21 VCO's connected directly to a set of subcarrier discriminators, with the signal recorded on magnetic tape and played back through the discriminators and with the signal transmitted by a frequency-modulated FM S-band radio frequency RF transmitter to a FM receiver and through the subcarrier discriminators. Tape speed flutter was induced to determine the reduction in flutter noise which can be obtained by the tape speed compensation equipment. The RF transmission test included transmitting the composite signal at a nominal RF received signal of -73 dbm and at RF levels of -83 and -86 dbm.

Haddick, C. M.↗

Inventories of Delaware's coastal vegetation and land-use utilizing digital processing of ERTS-1 imagery

Digital analysis of ERTS-1 imagery was used in an attempt to map and inventory the significant ecological communities of Delaware's coastal zone. Eight vegetation and land use discrimination classes were selected: (1) phragmites communis (Giant Reed grass); (2) spartina alterniflora (Salt marsh cord grass); (3) spartina patens (Salt marsh hay); (4) shallow water and exposed mud; (5) deep water (2 meters); (6) forest; (7) agriculture; and (8) exposed sand and concrete. Canonical analysis showed that classification accuracy was quite good with spartina alterniflora, exposed sand-concrete, and forested land - all discriminated with between 94% and 100% accuracy. The shallow water-mud and deep water categories were classified with accuracies of 88% and 93% respectively. Phragmites communis showed a classification accuracy of 83% with all confusion occurring with spartina patens which may be due to use of mixed stands of these species as training sets. Discrimination of spartina patens was very poor (accuracy 52%).

Klemas, V.↗

Geologic information from satellite images

Extracting geologic information from ERTS and Skylab/EREP images is best done by a geologist trained in photo-interpretation. The information is at a regional scale, and three basic types are available: rock and soil, geologic structures, and landforms. Discrimination between alluvium and sedimentary or crystalline bedrock, and between units in thick sedimentary sequences is best, primarily because of topographic expression and vegetation differences. Discrimination between crystalline rock types is poor. Folds and fractures are the best displayed geologic features. They are recognizable by topographic expression, drainage patterns, and rock or vegetation tonal patterns. Landforms are easily discriminated by their familiar shapes and patterns. Several examples demonstrate the applicability of satellite images to tectonic analysis and petroleum and mineral exploration.

Lee, K.↗

Advances in automatic extraction of earth resources information from multispectral scanner data

The basis of spectral discrimination was briefly examined indicating sources of variability which tend to obscure the spectral attributes of the classes of interest. Spatial and temporal discrimination bases are also discussed. Automatic processing functions, techniques and methods, and equipment are discussed with emphasis on techniques and equipment required for operational large area surveys with satellite data. Techniques for carrying out major functions of preprocessing for signature extension, feature extraction, discrimination, display, and applications modeling were examined. A multiplicative and additive signature correction technique and a proportion estimation technique are discussed. The development of the multivariate interactive digital analysis system multispectral processor system which represents a breakthrough in cost effective high throughput processing for large area surveys from satellites and aircraft is reviewed. Applications and results are discussed briefly for agricultural crop inventories, environmental monitoring, and resources surveys from ERIM LANDSAT and EREP investigations to indicate the substantial progress achieved to date.

Erickson, J. D.↗

Relationships between vegetation and terrain variables in southeastern Arizona

The author has identified the following significant results. Relationships were established between eight terrain variables and plant species and 31 vegetation types. Certain plant species are better than others for differentiating or discriminating groups of specified terrain variables. Certain terrain variables are better than others for differentiating or discriminating groups of vegetation types. Stepwise discriminant analysis was shown to be a useful tool in plant ecological studies.

Mouat, D. A.↗

Evaluation of LANDSAT MSS vs TM simulated data for distinguishing hydrothermal alteration

The LANDSAT Follow-On (LFO) data was simulated to demonstrate the mineral exploration capability of this system for segregating different types of hydrothermal alteration and to compare this capability with that of the existing LANDSAT system. Multispectral data were acquired for several test sites with the Bendix 24-channel MSDS scanner. Contrast enhancements, band ratioing, and principal component transformations were used to process the simulated LFO data for analysis. For Red Mountain, Arizona, the LFO data allowed identification of silicified areas, not identifiable with LANDSAT 1 and 2 data. The improved LFO resolution allowed detection of small silicic outcrops and of a narrow silicified dike. For Cuprite - Ralston, Nevada, the LFO spectral bands allowed discrimination of argillic and opalized altered areas; these could not be spectrally discriminated using LANDSAT 1 and 2 data. Addition of data from the 1.3- and 2.2- micrometer regions allowed better discriminations of hydrothermal alteration types.

Abrams, M. J.↗

Global crop production forecasting data system analysis

The author has identified the following significant results. Findings led to the development of a theory of radiometric discrimination employing the mathematical framework of the theory of discrimination between scintillating radar targets. The theory indicated that the functions which drive accuracy of discrimination are the contrast ratio between targets, and the number of samples, or pixels, observed. Theoretical results led to three primary consequences, as regards the data system: (1) agricultural targets must be imaged at correctly chosen times, when the relative evolution of the crop's development is such as to maximize their contrast; (2) under these favorable conditions, the number of observed pixels can be significantly reduced with respect to wall-to-wall measurements; and (3) remotely sensed radiometric data must be suitably mixed with other auxiliary data, derived from external sources.

Castruccio, P. A.↗