End-Use Load Profiles for the U.S. Building Stock: Market Needs, Use Cases, and Data Gaps

States and utilities are developing increasingly ambitious energy goals. Part of the solution to meeting these goals is improving electric grid flexibility. This includes shifting electric demand to align with grid needs. Thus, identifying and using building energy efficiency and other distributed energy resources to produce the highest grid value requires highly resolved, accurate and accessible electricity end-use load profiles (EULPs). EULPs quantify how and when energy is used. Currently, few accurate and accessible end-use load profiles are available for utilities, public utility commissions, state energy offices and other stakeholders to use to prioritize investment and value energy efficiency, demand response, distributed generation and energy storage. High-quality EULPs are also critical for determining the time-sensitive value of efficiency and other distributed energy resources, and the widespread adoption of grid-interactive efficient buildings (GEBs).For example, EULPs can be used to accurately forecast energy savings in buildings or identify energy activities that can be shifted to different times of the day. This report serves as the first-year deliverable for a multiyear U.S. Department of Energy-funded project, End-Use Load Profiles for the U.S. Building Stock, that intends to produce a set of highly resolved EULPs of the U.S. residential and commercial building stock. The project team, made up of researchers from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory (LBNL), and Argonne National Laboratory, ultimately will use calibrated physics-based building energy models to create these EULPs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Load Profiles for the U.S. Building Stock: Market Needs, Use Cases, and Data Gaps

States and utilities are developing increasingly ambitious energy goals. Part of the solution to meeting these goals is improving electric grid flexibility. This includes shifting electric demand to align with grid needs. Thus, identifying and using building energy efficiency and other distributed energy resources to produce the highest grid value requires highly resolved, accurate and accessible electricity end-use load profiles (EULPs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TCF - Sustainable Well Cement for Geothermal, Thermal Recovery, and Carbon Storage wells

Primary cementing is the most important operation performed on a subterranean well. Cement, placed in the annulus between the casing and the formations, serves as a hydraulic seal preventing fluids and gas migrations, protecting steel casing from corrosion, and supporting the well structure. Poor cementing jobs can be directly responsible for wells not reaching their full capacity, casing corrosion, compromised well integrity and, in the worst-case scenarios, well collapse. Geothermal, thermal recovery, and carbon storage wells offer environments that are especially difficult for cements to survive while the required lifespan of these wells can be years. In these wells currently used cements cannot provide durable well integrity, and new solutions are necessary. The necessity of stabilizing the electric grid, increasing its flexibility, and providing energy on demand will further expand the market of durable cement solutions for applications in high-temperature underground reservoir thermal energy storage wells (HT RTES). The design challenges of special cement systems for such wells originate from chemistry limitations of currently used well cements, aggressive environments, temperature and repeated shock conditions associated with them, and very weak formations that are not uncommon in these wells. During the last 70 years the most common systems for thermal-well construction have been Ordinary Portland Cement (OPC) (absolute majority of the wells), silica-lime system, and high aluminum cement-containing formulations. The major issues of calcium-silicate hydrates, that form during the hydration of OPC resulting in hardened material, are their poor chemical resistance to acids due to the calcium interactions with acid anions followed by its eventual dissolution, even in mild acids, such as carbonic acid from CO 2 dissolution, and inadequate bonding to the steel causing serious casing corrosion problems (Sugama & Pyatina, 2019). Performance of OPC-based cement may be significantly improved with organic additives; however, those are limited by their temperature stability. An alternative to calcium-silicate cement was developed by BNL and commercialized by Halliburton as ThermaLock TM cement. Calcium-aluminate-phosphate-based chemistry of the material allowed overcoming acid-resistance problems of OPC, especially in CO 2 -rich geothermal environments. In 2012-2015, building upon this experience, BNL developed Thermal Shock Resistant Cement (TSRC) with the support of Geothermal Technology Office (GTO) of DOE. TSRC has high-temperature stable chemistry, superior properties of cement-metal casing bond and corrosion protection (4-times better than currently used OPC-based formulation), significantly outperforms common well-cements in thermal-shock tests, has self-healing properties, and like ThermaLock TM is CO 2 resistant incorporating carbonate ions into stable hydrates (Gill et al., 2012).

15 GEOTHERMAL ENERGY↗

Electrolyzers Enhancing Flexibility in Electric Grids

This paper presents a real-time simulation with hardware-in-the-loop (HIL) based approach for verifying the performance of electrolyzer systems in providing grid support. Hydrogen refueling stations premdominantly use electrolyzer systems to generate hydrogen, and are proposed to have the potential of becoming smarter loads which can pro-actively provide grid services. Based on experimental findings electrolyzer systems are observed to have a high level of controllability and hence can add flexibility to the grid from demand side. Greater awareness and controllability is proposed, developed, implemented, and tested by a 'frond end controller' in real-time environment. It can optimize the operation of electrolyzer systems based on the information collected by a communication module. Real-time tests are performed to verify the performance of front end controller driven electrolyzers to provide grid support that enables greater economic revenue and grid support for hydrogen producers under dynamic conditions. The front end controller proposed in this paper is tested with electrolyzers, however it is proposed as a generic control topology that is applicable to any load.

08 HYDROGEN↗

The key to successful management of STS operations: An integrated production planning system

Space Transportation System operations managers are being confronted with a unique set of challenges as a result of increasing flight rates, the demand for flight manifest/production schedule flexibility and an emphasis on continued cost reduction. These challenges have created the need for an integrated production planning system that provides managers with the capability to plan, schedule, status and account for an orderly flow of products and services across a large, multi-discipline organization. With increased visibility into the end-to-end production flow for individual and parallel missions in process, managers can assess the integrated impact of changes, identify and measure the interrelationships of resource, schedule, and technical performance requirements and prioritize productivity enhancements.

Johnson, W. A.↗

Network design consideration of a satellite-based mobile communications system

Technical considerations for the Mobile Satellite Experiment (MSAT-X), the ground segment testbed for the low-cost spectral efficient satellite-based mobile communications technologies being developed for the 1990's, are discussed. The Network Management Center contains a flexible resource sharing algorithm, the Demand Assigned Multiple Access scheme, which partitions the satellite transponder bandwidth among voice, data, and request channels. Satellite use of multiple UHF beams permits frequency reuse. The backhaul communications and the Telemetry, Tracking and Control traffic are provided through a single full-coverage SHF beam. Mobile Terminals communicate with the satellite using UHF. All communications including SHF-SHF between Base Stations and/or Gateways, are routed through the satellite. Because MSAT-X is an experimental network, higher level network protocols (which are service-specific) will be developed only to test the operation of the lowest three levels, the physical, data link, and network layers.

Yan, T.-Y.↗

An Integrated Architecture for Onboard Spacecraft

As increasingly complex scientific and environmental observation spacecraft are deployed, the burden on the downlink assets, and ground-based systems complexity and cost is becoming a major problem. Already, the limitations of communications bandwidth and processing throughput limit the science data gathering, both in volume and in rate. This poses a dilemma to the scientist experimenter forcing choices between data collection and bandwidth/processing/archiving. Advances in ground based processing and space-to-Earth links have fallen behind the requirements for observation data, at increasing rates, over the last few decades. As NASA achieves its 40th anniversary, the ability to observe and capture phenomena of theoretical and practical interest to life on Earth far outstrips the ability to transfer, process, or store these data. NASA recognizes the need to invest on technological advancements that will enable both the space and ground systems to address the limitations. Spacecraft onboard computing power is a clear one. The capability of creating data products onboard the spacecraft adds a new level of flexibility to address the more demanding observation needs. Current spacecraft computing power is limited and incapable of addressing the needs of the new generation of observation satellites because extensive onboard data processing is required. Traditional spacecraft architectures only collect, package, and transmit to Earth the data acquired by multiple instruments. Conversely, the experience on developing ground data systems shows the need for high performance computing systems to process and create information from the instrumentation data. The expectation is that supercomputing technology is required to enable spacecraft to create information onboard. Moving supercomputing capability onboard spacecraft requires an approach that considers an integrated data architecture. Otherwise, it may simply convert a compute-bound problem into a communications bound problem, as has been shown numerous times in the context of massively parallel architectures. What is left to determine are the technologies that will enable spacecraft high performance computing.

Figueiredo, Marco A.↗

A Flight Rule Checker for the LADEE Lunar Spacecraft

As part of the design of a space mission, an important part is the design of so-called flight rules. Flight rules express constraints on various parts and processes of the mission, that if followed, will reduce the risk of failure. One such set of flight rules constrain the format of command sequences regularly (e.g. daily) sent to the spacecraft to con-trol its next near term behavior. We present a high-level view of the automated flight rule checker FRC for checking command sequences sent to NASA’s LADEE Lunar mission spacecraft, used throughout its entire mission. A command sequence is in this case essentially a program (a sequence of commands) with no loops or conditionals, and it can there-fore be verified with a trace analysis tool. FRC is implemented using the TraceContract runtime verification tool, an internal Scala DSL for checking event sequences against “formal specifications”. The paper illustrates this untraditional use of runtime verification in a real con-text, with strong demands on the expressiveness and flexibility of the specification language, illustrating the advantages of an internal DSL.

LADEE↗

A Flight Rule Checker for the LADEE Lunar Spacecraft

As part of the design of a space mission, an important part is the design of so-called flight rules. Flight rules express constraints on various parts and processes of the mission, that if followed, will reduce the risk of failure. One such set of flight rules constrain the format of command sequences regularly (e.g. daily) sent to the spacecraft to con- trol its next near term behavior. We present a high-level view of the automated flight rule checker Frc for checking command sequences sent to NASA’s LADEE Lunar mission spacecraft, used throughout its entire mission. A command sequence is in this case essentially a program (a sequence of commands) with no loops or conditionals, and it can there- fore be verified with a trace analysis tool. Frc is implemented using the TraceContract runtime verification tool, an internal Scala DSL for checking event sequences against “formal specifications”. The paper illustrates this untraditional use of runtime verification in a real con- text, with strong demands on the expressiveness and flexibility of the specification language, illustrating the advantages of an internal DSL.

Kurklu, Elif↗

Assessing the Institution of the Nuclear Nonproliferation Regime

The nuclear nonproliferation regime is facing a crisis of effectiveness. During the Cold War, the regime was relatively effective in stemming the proliferation of nuclear weapons and building an institutional structure that could, under certain conditions, ensure continued success. However, in the evolving global context, the traditional approaches are becoming less appropriate. Globalization has introduced new sets of stresses on the nonproliferation regime, such as the rise of non-state actors, broadening extensity and intensity of supply chains, and the multipolarization of power. This evolving global context demands an analytical and political flexibility in order to meet future threats. Current institutional capabilities established during the Cold War are now insufficient to meet the nonproliferation regime’s current and future needs. The research was based on information gathered through interviews and reviews of the relevant literature, and two dominant themes emerged. First, that human security should be integrated into the regime to account for the rise of non-state actors and networked violence. Second, confidence in the regime’s overall effectiveness has eroded at a time where verification-based confidence is becoming more essential. The research postulates that a critical analysis of the regime that fully utilizes institutional theory, with its focus on rules, normative structures, and procedures will be essential to adapting the regime to the current global context, building mechanisms for generating trust, creating better enforcement, and providing flexibility for the future.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Quantifying the Value of Grid-Interactive Efficient Buildings through Field Study

Quantifying the annual energy impacts of efficient technologies in commercial buildings has been well established by the building science field. As we move toward enabling grid-interactive efficient buildings (GEB) targeting flexible building operation and carbon reduction, quantification methods to evaluate time-sensitive peak load and emissions impact are much less defined. A number of national laboratories are working to field validate four different GEB software solutions that provide the capability to control multiple building end-use systems in multiple load flexibility modes (i.e., energy efficiency, load shed, load shift, and possible load modulation at the second to sub-second level). To guide the laboratory leads in effective measurement and verification (M&V) practices, two of the laboratories collaborated to define metrics to quantify the impacts of flexible load control on building demand, utility costs, carbon emissions, facility management, and occupant comfort. This paper summarizes the proposed metrics to quantify peak load and emission impacts in the field, decision parameters, approaches to accurately conduct M&V, lessons learned, and outstanding needs and next steps.

Langner, Rois↗

Opportunities for Automated Demand Response in California Agricultural Irrigation

Pumping water for agricultural irrigation represents a significant share of California’s annual electricity use and peak demand. It also represents a large source of potential flexibility, as farms possess a form of storage in their wetted soil. By carefully modifying their irrigation schedules, growers can participate in demand response without adverse effects on their crops. This report describes the potential for participation in demand response and automated demand response by agricultural irrigators in California, as well as barriers to widespread participation. The report first describes the magnitude, timing, location, purpose, and manner of energy use in California. Typical on-­farm controls are discussed, as well as common impediments to participation in demand response and automated demand response programs. Case studies of demand response programs in California and across the country are reviewed, and their results along with overall California demand estimates are used to estimate statewide demand response potential. Finally, recommendations are made for future research that can enhance the understanding of demand response potential in this industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Performance and flexibility improvements of Staged Pressurized Oxy-Combustion

Staged Pressurized Oxy-Combustion (SPOC) is a low-carbon coal combustion power technology being developed by Washington University in St. Louis (WUSTL). Oxy-combustion plants enable straightforward capture of carbon dioxide (CO 2 ) by removing most of the nitrogen in the combustion air prior to use, thereby burning fuel in near-pure oxygen instead of air, producing a flue gas containing primarily CO 2 and water. CO 2 capture at amounts > 90% is possible, often using cryogenic air separation. Oxy-combustion typically relies on flue gas recycle (FGR) to reduce the peak temperature and radiation that would otherwise occur in a fuel/oxygen only flame. SPOC reduces the peak temperatures of combustion by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given furnace module. This means that the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. Also, the process operates at an elevated gas-side pressure, reducing boiler size, enhancing heat transfer to achieve a compact boiler configuration as compared to an atmospheric-pressure boiler design, and allowing for recovery of the latent heat of the water from the flue gas at a temperature useful to the steam cycle. The resultant net efficiency of the system is over 3 percentage points greater than traditional atmospheric-pressure oxy-combustion, and 7 percentage points greater than the post combustion variant, representing a step-change improvement over first-generation capture technologies. To further develop the concept, WUSTL and the Electric Power Research Institute, Inc., organized a project with American Air Liquide, Inc., Doosan Babcock Limited, and the U.S. Department of Energy to investigate a practicable and workable boiler design. The team has identified the potential for enhanced process flexibility for controlling power generation over a wider load range than is normally available to conventional coal-fired power plants due to the staged nature of the heat release. With increasing intermittent renewable generator contribution, on-demand generators need to be highly flexible to participate in the future energy market, requiring extensive operation at reduced load. Conventional coal-fired steam generators typically face challenges in maintaining temperature control of the reheat steam and main steam at reduced loads. This results in inefficient operation, both in terms of the boiler efficiency and steam turbine heat rate. The results of this project show the SPOC process is capable of exceptional turndown, both on a stage basis and with the ability to bypass entire stages. Oxygen-supply flexibility was also investigated, as this is also a key consideration for the overall flexibility of the SPOC process given the operating constraints of conventional air separation units. A boiler design concept assessment was conducted and was focused on delivering compact and constructible design. The assessment checked appropriate tube operating metal temperatures at full load and at lower operating loads, balanced against the needs of efficient coal combustion, and the resultant slagging and ash environments. Combustion testing in the 100-kWth pressurized combustion test rig at WUSTL was carried out to validate the combustion, heat flux profiles and burnout at multiple loads. Combustion parameters investigated were flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. The results of these tests formed the basis of a full-scale boiler design that will encompass improvements in both efficiency and flexibility over conventional oxy-combustion processes. The air separation unit flexibility was investigated, and associated cost implications were addressed. Detailed economic assessment results for a 550 MWe net power block are also provided, allowing for a comparison against the baseline NETL oxy-combustion and post combustion capture cases.

20 FOSSIL-FUELED POWER PLANTS↗

New automated inventory/material accounting system (AIMAS) version for former Soviet Union countries

AIMAS (Automated Inventory/Material Accounting System) is a PC-based application for site-level nuclear material accountancy that was originally developed in the late 90's as a part of the U.S Department of Energy Assistance Program to Ukraine. Designed to be flexible and secure, plus place minimal demands on computing infrastructure, it was originally developed to run in early Windows operating system (OS) environments like W98 and W3.1. The development, support, and maintenance of AIMAS were transferred to Ukraine in 2002. Because it is highly flexible and can be configured to meet diverse end-user's needs, the software has been used at several facilities in Ukraine. Incorporating added functionality is planned to support nuclear installations in the Republic of Kazakhstan and Uzbekistan, as well. An improved 32-bit version of AIMAS has recently been developed to operate effectively on modern PCs running the latest Windows OS by AVIS, the Ukrainian developer. In the paper we discuss the status of AIMAS, plans for new functions, and describe the strategy for addressing a sustainable software life-cycle while meeting user requirements in multiple FSU countries.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Multiplexed photoinjector optimization for high-repetition-rate free-electron lasers

The multiplexing capabilities of superconducting X-ray free-electron lasers (FELs) have gained much attention in recent years. The demanding requirements for photon properties from multiple undulator lines necessitate more flexible beam manipulation techniques to achieve the goal of “beam on demand”. In this paper, we investigate a multiplexed configuration for the photoinjector of high-repetition-rate FELs that aims to simultaneously provide low-emittance electron beams of different charges. A parallel, multi-objective genetic algorithm is implemented for the photoinjector parameter optimization. The proposed configuration could drastically enhance the flexibility of beam manipulation to improve multiplexing capabilities and realize the full potential of the facility.

47 OTHER INSTRUMENTATION↗

Projecting Electric Vehicle Electricity Demands and Charging Loads

After over a century of petroleum dominance, electric vehicles are rapidly disrupting the transportation energy landscape. At the same time, the electric power systems are undergoing profound changes as variable renewables replace dispatchable fossil generators. It is critically important to understand how transportation electrification will impact electricity demand, including changes in the load shapes that characterize the system, and the value of flexible electric vehicle charging to better balance electricity demand and supply. This talk focuses on methods to project electricity demand for EV charging with high spatiotemporal fidelity to enable electricity system modeling and analysis and summarizes results from recent NREL studies in this area.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.