Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Fabrication of Cryogenic Manganite Bolometers to Measure the Total Energy at the LCLS Free Electron X-ray Laser

We are developing cryogenic bolometers to measure the total energy of the Linac Coherent Light Source (LCLS) free electron X-ray laser that is currently being built at the Stanford Linear Accelerator Center. LCLS will produce ultrashort {approx}200 fs X-ray laser pulses with {approx}10{sup 13} photons at 0.8 keV up to {approx}10{sup 12} photons at 8 keV per pulse at a repeat interval as short as 8 ms, and will be accompanied by a halo of spontaneous undulator radiation. Our bolometer consists of a 375 {micro}m thick Si absorber and a Nd{sub 0.67}Sr{sub 0.33}MnO{sub 3} sensor operated at its metal-insulator transition. It will measure the total energy of each pulse with a precision of <1%, and is designed to meet the conflicting requirements of radiation hardness, sensitivity, linearity over a dynamic range of three orders of magnitude, and readout speed compatible with the LCLS pulse rate. Here we discuss bolometer design and fabrication, and the photoresponse of prototype devices to pulsed optical lasers.

42 ENGINEERING↗

Design, construction and commissioning of the proximity cryogenics systems serving two large-scale prototypes of the future DUNE neutrino detector

In the context of the Neutrino Platform, CERN has designed, constructed, and commissioned the proximity cryogenics systems that serve two CERN based large-scale prototypes of future neutrino detectors. Each of these prototypes features a high voltage time projection chamber placed inside a membrane cryostat being submerged in 600m3 of liquid argon at about 1.0 bar. A copper and molecular sieve based cryogenic purification system has to ensure that the argon in the cryostat has a contamination level below 100 ppt oxygen equivalent. The two proximity cryogenics systems provide the purging, cool-down, filling, normal operation and emptying modes for each cryostat. This paper reports on the design, construction and commissioning of the ProtoDUNE proximity cryogenics facilities.

43 PARTICLE ACCELERATORS↗

Alternative Techniques for Injecting Massive Quantities of Gas for Plasma Disruption Mitigation

Injection of massive quantities of noble gases or D2 has proven to be effective at mitigating some of the deleterious effects of disruptions in tokamaks. Two alternative methods that might offer some advantages over the present technique for massive gas injection are shattering massive pellets and employing closecoupled rupture disks. Laboratory testing has been carried out to evaluate their feasibility. For the study of massive pellets, a pipe gun pellet injector cooled with a cryogenic refrigerator was fitted with a relatively large barrel (16.5 mm bore), and D2 and Ne pellets were made and were accelerated to speeds of ~600 and 300 m/s, respectively. Based on the successful proof-of-principle testing with the injector and a special double-impact target to shatter pellets, a similar system has been prepared and installed on DIII-D, with preliminary experiments already carried out. To study the applicability of rupture disks for disruption mitigation, a simple test apparatus was assembled in the lab. Commercially available rupture disks of 1 in. nominal diameter were tested at conditions relevant for the application on tokamaks, including tests with Ar and He gases and rupture pressures of ~54 bar. Some technical and practical issues of implementing this technique on a tokamak are discussed.

disruption↗

Massive Pellet and Rupture Disk Testing for Disruption Mitigation Applications

Injection of massive quantities of noble gases or D2 has proven to be effective at mitigating some of the deleterious effects of disruptions in tokamaks. Two alternative methods that might offer some advantages over the present technique for massive gas injection are shattering massive pellets and employing close-coupled rupture disks. Laboratory testing has been carried out to evaluate their feasibility. For the study of massive pellets, a pipe gun pellet injector cooled with a cryogenic refrigerator was fitted with a relatively large barrel (16.5 mm bore), and D2 and Ne pellets were made and were accelerated to speeds of ~600 and 300 m/s, respectively. Based on the successful proof-of-principle testing with the injector and a special double-impact target to shatter pellets, a similar system has been prepared and installed on DIII-D and should be ready for experiments later this year. To study the applicability of rupture disks for disruption mitigation, a simple test apparatus was assembled in the lab. Commercially available rupture disks of 1 in. nominal diameter were tested at conditions relevant for the application on tokamaks, including tests with Ar and He gases and rupture pressures of ~54 bar. Some technical and practical issues of implementing this technique on a tokamak are discussed.

Combs, Stephen Kirk↗

Characterization of Candidate Insulation Resins for Training Reduction in High Energy Physics Magnets

Superconducting magnets are critical components in particle accelerators and are used to generate and sustain the large magnetic fields needed for High Energy Physics programs. One significant issue with current epoxy insulated Nb$_{3}$Sn magnets is the long training process required before stable magnet performance can be realized. It is believed that training can be significantly reduced by addressing magnet quenching through improvements in the epoxy electrical insulation. In this work, two approaches for insulation modification have been undertaken: (1) addition of thermally conductive fillers to help with quench management and (2) development of insulation resins with high strain capability at cryogenic temperatures. This paper will discuss the characterization of these insulation systems to verify their performance prior to evaluation in subscale Nb$_{3}$Sn canted cosine theta accelerator dipole magnets.

43 PARTICLE ACCELERATORS↗

Aerosol-Assisted Solid Debris Collection for the National Ignition Facility

The National Ignition Facility (NIF) has been completed and has made its first shots on-target. While upcoming experiments will be focused on achieving ignition, a variety of subsequent experiments are planned for the facility, including measurement of cross sections, astrophysical measurements, and investigation of hydrodynamic instability in the target capsule. In order to successfully execute several of these planned experiments, the ability to collect solid debris following a NIF capsule shot will be required. The ability to collect and analyze solid debris generated in a shot at the National Ignition Facility (NIF) will greatly expand the number of nuclear reactions studied for diagnostic purposes. Currently, reactions are limited to only those producing noble gases for cryogenic collection and counting with the Radchem Apparatus for Gas Sampling (RAGS). The radchem solid collection diagnostic has already been identified by NIF to be valuable for the determination and understanding of mix generated in the target capsule's ablation. LLNL is currently developing this solid debris collection capability at NIF, and is in the stage of testing credible designs. Some of these designs explore the use of x-ray generated aerosols to assist in collection of solid debris. However, the variety of harsh experimental conditions this solid collection device will encounter in NIF are challenging to replicate. Experiments performed by Gary Grim et al. at Sandia National Laboratory's RHEPP1 facility have shown that ablation causes a cloud of material removed from an exposed surface to move normal to and away from the surface. This ablation is certain to be a concern in the NIF target chamber from the prompt x-rays, gamma rays, etc. generated in the shot. The cloud of ablated material could interfere with the collection of the desired reaction debris by slowing down the debris so that the kinetic energy is too low to allow implantation, or by stopping the debris from reaching the collection device entirely. Our goal is to use this primary ablation wave to our advantage, by the creation of ionized alkali metal halide salt aerosols. This technique is similar to that used by many particle accelerator groups for gas-jet transport. Ideally the salt would be ablated from a substrate, encounter the reaction debris, agglomerate, and be collected for further study. We have done studies at laser and pulsed-power facilities (Titan laser at LLNL, Trident laser at LANL, Zebra z-pinch at Nevada Terawatt Facility) evaluating the hardiness of materials for placement in the NIF target chamber, as well as testing aerosol generation by the incident x-rays generated in device shots. To test this method's potential success in the NIF environment, we have tested KCl, KI, RbI, and CsI films of 1 and 2 um linear thickness on aluminum and silicon wafer substrates in these aforementioned facilities, at varied distances. These salts do ablate in the presence of sufficient x-ray fluence. Further analysis to quantify the final ablation depth as a function of x-ray fluence is ongoing. Half of each sample was masked with a thick tungsten foil for photon opacity. KCl was the most difficult salt to ablate, from comparing the tungsten-masked side of the samples to the unmasked side of the samples. This is likely due to KCl's absorbance peak being at lower wavelengths than that of KI, {approx}160 nm vs. {approx}220 nm, respectively. Samples with and without collimation were tested to identify if any condensation of these ablated salts occurred after ablation. Visual inspection of the silicon wafer witness plates placed parallel to the direction of the incident photons showed that a vapor was deposited on the wafers next to the collimators. Further analysis with EDS in the case of the collimated samples conclusively identified the vapor as CsI. We also intend to examine samples of bare substrate exposed to the same experimental conditions for post-shot change via SEM images, optical microscopy, and atomic force microscopy (AFM). Furthermore, tests with separated isotopes may be done to reduce background contamination. When sample optimization is complete, we plan to develop a 'catcher' device for these desorbed aerosols. Current ideas include biased grids to either attract the ionized particles to the grid, or repel them towards a collection device.

36 MATERIALS SCIENCE↗

Design and structural basis of selective 1,4-dihydropyridine inhibitors of the calcium-activated potassium channel K Ca 3.1

The 1,4-dihydropyridines, drugs with well-established bioavailability and toxicity profiles, have proven efficacy in treating human hypertension, peripheral vascular disorders, and coronary artery disease. Every 1,4-dihydropyridine in clinical use blocks L-type voltage-gated calcium channels. We now report our development, using selective optimization of a side activity (SOSA), of a class of 1,4-dihydropyridines that selectively and potently inhibit the intermediate-conductance calcium-activated K + channel K Ca 3.1, a validated therapeutic target for diseases affecting many organ systems. One of these 1,4-dihydropyridines, DHP-103, blocked K Ca 3.1 with an IC 50 of 6 nM and exhibited exquisite selectivity over calcium channels and a panel of >100 additional molecular targets. Using high-resolution structure determination by cryogenic electron microscopy together with mutagenesis and electrophysiology, we delineated the drug binding pocket for DHP-103 within the water-filled central cavity of the K Ca 3.1 channel pore, where bound drug directly impedes ion permeation. DHP-103 inhibited gain-of-function mutant K Ca 3.1 channels that cause hereditary xerocytosis, suggesting its potential use as a therapeutic for this hemolytic anemia. In a rat model of acute ischemic stroke, the second leading cause of death worldwide, DHP-103 administered 12 h postischemic insult in proof-of-concept studies reduced infarct volume, improved balance beam performance (measure of proprioception) and decreased numbers of activated microglia in infarcted areas. K Ca 3.1-selective 1,4-dihydropyridines hold promise for the many diseases for which K Ca 3.1 has been experimentally confirmed as a therapeutic target.

Ong, Seow Theng [Lee Kong Chian School of Medicine↗

The KATRIN superconducting magnets: Overview and first performance results

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6 T, adiabatically guide β-electrons from the source to the detector within a magnetic flux of 191 Tcm 2 . A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064 m to 9 m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70% of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01% per month at 70% of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.

47 OTHER INSTRUMENTATION↗

Preliminary Results of the CASCADE Hidden Sector Photon Search

Light shining through a wall experiments can be used to make measurements of photon-WISP couplings. The first stage of the CASCADE experiment at the Cockcroft Institute of Accelerator Science and Technology is intended to be a proof-of-principle experiment utilising standard microwave technologies to make a modular, cryogenic HSP detector to take advantage of future high-power superconducting cavity tests. In these proceedings we will be presenting the preliminary results of the CASCADE LSW experiment showing a peak expected exclusion of $1.10\times10^{-8}$ in the mass range from 1.96\,$\mu$eV to 5.38\,$\mu$eV, exceeding current limits.

Woollett, Nathan↗

Low-G fluid transfer technology study

Technology gaps and system characteristics critical to cryogenic and noncryogenic in-orbit fluid transfer were identified. Four different supply systems were conceptually designed as space shuttle payloads. These were; (1) space tug supply - LH2, LO2, N2H4, He - linear acceleration for liquid acquisition with supply module and tug separated from shuttle, (2) tug supply using orbiter drag, (3) orbiter supply - N2O4,MMH,He, H2,O2 - surface tension screens, (4) multiple receivers supply 0 solar electric propulsion stage, Hg, diaphragm - HEAO B, HEe, paddle fluid rotation-satellite control section, N2H4, screens. It was found that screens had the best overall potential for low weight and simplicity, however, thermal problems with cryogenics still need final resolution.

Stark, J. A.↗

Cryogenic electron tomography by the numbers: Charting underexplored lineages in structural cell biology

Imaging cells and their interactions across the whole biosphere with molecular-scale resolution is key for understanding structure–function relations. Cryogenic electron tomography (cryo-ET) is a powerful method for obtaining this critical information. However, cryo-ET studies are challenging and often limited to a small number of cell types per study. Here, we collate cryo-ET data from hundreds of cells and tissues across the biosphere to i) identify emerging methodological trends, ii) pinpoint strategies to reduce imaging time and costs, iii) quantitatively compare methods for cell freezing and sectioning, and iv) census cryo-ET species coverage across all domains of life. Comparing the fraction of cellular material within a single lamella across all domains of life reveals an order of magnitude difference between eukaryotes (1%) compared to bacteria (9%) and archaea (14%). We calculate the fraction of cellular material which can be imaged using distinct sectioning methods on multicellular communities and tissues—identifying serial lift-out as a powerful approach for obtaining more complete cellular depictions. Finally, we show that the biodiversity of current cryo-ET studies is 2 to 3 orders of magnitude lower than in sequence libraries and 4 to 5 lower than the total predicted on Earth. Our analyses reveal major evolutionary lineages which remain critically understudied and highlight where future cryo-ET research would be most impactful.

HPF↗

Cryogenic and safety design of the future high field cable test facility at Fermilab

The HFVMTF (High Field Vertical Magnet Test Facility) is a new experimental facility under development at Fermi National Accelerator Laboratory (FNAL) to test large superconducting magnets (up to 20 tons weight and 1.3 m diameter) in a double bath superfluid helium cryostat (1.9 K and 1.2 bar). Coupled with a superconducting dipole magnet fabricated by Lawrence Berkeley National Laboratory (LBNL), this facility will be able to test future high-temperature superconductor (HTS) cables under a background magnetic field of 15 T for fusion magnets. This paper describes the design of the cryostat and its 1.4-meter diameter lambda plate, as well as the different components for a safe operation of the facility, even during critical events such a magnet quench or a vacuum breaking situation. The project is funded by US DOE Offices of Science, High Energy Physics (HEP), and Fusion Energy Sciences (FES).

43 PARTICLE ACCELERATORS↗

Optical Interference for the Guidance of Cryogenic Focused Ion Beam Milling Beyond the Axial Diffraction Limit

Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labelled structures with accuracy beyond the diffraction limit. We demonstrate the approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of water. Here, we then apply the approach to capture virions inside host cells. Successful targeting is confirmed by cryogenic electron tomography revealing clusters of virions in intracellular vesicles.

Sica, Anthony V. [SLAC National Accelerator Labora↗

Neutronics analyses in support of rotating target developments at SNS

A second target station (STS) for Spallation Neutron Souce (SNS) very likely being operated in long-pulse mode is in the early design phase, will complement the ORNL neutron sources, which presently consist of a short-pulse spallation source and the HFIR research reactor. As an alternative to the stationary liquid metal target, a rotating target is being considered. Neutronics studies in support of a 3MW power 20 Hz repetition rate rotating target feasibility study funded through the laboratory LDRD program, was extended towards a 1.5 MW STS design. The scope of work included in-operation heat deposition rates in target structures for thermal and structural analyses, target radionuclide inventory for decay heat and safety analyses, lifetime estimations due to radiation-driven material damage of target and moderator components, moderator neutron performance and moderator cryogenic heatloads.

43 PARTICLE ACCELERATORS↗

Accelerated path integral methods for atomistic simulations at ultra-low temperatures

Path integral methods provide a rigorous and systematically convergent framework to include the quantum mechanical nature of atomic nuclei in the evaluation of the equilibrium properties of molecules, liquids, or solids at finite temperature. Such nuclear quantum effects are often significant for light nuclei already at room temperature, but become crucial at cryogenic temperatures such as those provided by superfluid helium as a solvent. Unfortunately, the cost of converged path integral simulations increases significantly upon lowering the temperature so that the computational burden of simulating matter at the typical superfluid helium temperatures becomes prohibitive. Here we investigate how accelerated path integral techniques based on colored noise generalized Langevin equations, in particular the so-called path integral generalized Langevin equation thermostat (PIGLET) variant, perform in this extreme quantum regime using as an example the quasi-rigid methane molecule and its highly fluxional protonated cousin, CH{sub 5}{sup +}. We show that the PIGLET technique gives a speedup of two orders of magnitude in the evaluation of structural observables and quantum kinetic energy at ultralow temperatures. Moreover, we computed the spatial spread of the quantum nuclei in CH{sub 4} to illustrate the limits of using such colored noise thermostats close to the many body quantum ground state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗