Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Quality-Controlled Meteorological Data from the Flood Control District of Maricopa County (FCDMC) Network, Phoenix, Arizona (1987-2024)

This dataset contains 15- or 30-minute interval meteorological data from the Flood Control District of Maricopa County (FCDMC), Arizona, USA, covering eight key variables across multiple sensor stations between 1987 and 2024. Each variable is stored as a separate CSV file, containing time-series data that have undergone rigorous quality control (QC) procedures and, where appropriate, short-gap interpolation for consistency. The quality control (QC) pipeline consisted of four sequential tests: (1) a range test to ensure all values fall within physically realistic limits, (2) a step test to identify abrupt and implausible changes between consecutive records, (3) a proximity test that validates flagged values from step test using data from nearby stations and exceedance probability thresholds, and (4) a persistence test to detect and remove periods of unrealistically constant readings. These thresholds were calibrated to Arizona’s environmental conditions and sensor specifications. After QC, short gaps (≤2 hours) were linearly interpolated to ensure consistent temporal resolution, except for wind variables. Due to a major upgrade in FCDMC’s data transmission system, only ALERT-2 protocol data (2016–2024) for wind variables are included; earlier ALERT-1 data were excluded because of irregular sampling and high missing rates. This dataset supports regional climate and infrastructure resilience studies by providing standardized, high-resolution meteorological data for the greater Phoenix metropolitan area.

54 ENVIRONMENTAL SCIENCES↗

Development of Microreactor Automated Control System (MACS): Surrogate Plant-level Modeling and Control Algorithms Integration

This report discusses progress on the modeling and integration task as part of the development of Microreactor Automated Control System (MACS). What follows is a discussion of the software tools used to develop a surrogate microreactor plant-level model, MACS module development, and a summary of the findings from integration with a hardware-in-the-loop (HIL) setup at Idaho National Laboratory (INL). Oak Ridge National Laboratory worked with INL to understand available hardware at INL (such as existing control platforms). With this information and using a preliminary framework for MACS with software interfaces defined, surrogate models and initial automated control algorithms were created for integration into the hardware to provide a HIL demonstration platform for MACS. Available reduced order reactor models that leverage existing microreactor neutronics and thermal hydraulics models have been integrated in the surrogate plant-level model. The surrogate model has been evaluated for sensitivity of all parameters and the MACS software modules (including the surrogate model) have been demonstrated to interact with the hardware. The integration, however, pointed to the need for further improvements to the framework—and specifically improvements to the interfaces to ensure that the HIL simulator is capable of longer-term stable operation with MACS in the loop. These improvements will be the focus of future research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Development of Heat Transfer Model-Based Control Algorithms of Liquid Sodium Purification System: Advanced Sensors and Instrumentation Advanced Controls

Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Control of plasma stored energy for burn control using DIII-D in-vessel coils

A new approach has been experimentally demonstrated to control the stored energy by applying a non-axisymmetric magnetic field using the DIII-D in-vessel coils to modify the energy confinement time. In future burning plasma experiments as well as magnetic fusion energy power plants, various concepts have been proposed to control the fusion power. The fusion power in a power plant operating at high gain can be related to the plasma stored energy and hence, is a strong function of the energy confinement time. Thus, an actuator that modifies the confinement time can be used to adjust the fusion power. In relatively low collisionality DIII-D discharges, the application of non-axisymmetric magnetic fields results in a decrease in confinement time and density pumpout. Gas puffing was used to compensate the density pumpout in the pedestal while control of the stored energy was demonstrated by the application of non-axisymmetric fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed Power Flow Control: Distributed Power Flow Control using Smart Wires for Energy Routing

GENI Project: Smart Wire Grid is developing a solution for controlling power flow within the electric grid to better manage unused and overall transmission capacity. The 300,000 miles of high-voltage transmission line in the U.S. today are congested and inefficient, with only around 50% of all transmission capacity utilized at any given time. Increased consumer demand should be met in part with more efficient and an economical power flow. Smart Wire Grid’s devices clamp onto existing transmission lines and control the flow of power within—much like how internet routers help allocate bandwidth throughout the web. Smart wires could support greater use of renewable energy by providing more consistent control over how that energy is routed within the grid on a real-time basis. This would lessen the concerns surrounding the grid’s inability to effectively store intermittent energy from renewables for later use.

ARPA-E↗

Control of Plasma-Stored Energy for Burn Control using DIII-D In-Vessel Coils

A new approach has been experimentally demonstrated to control the stored energy by applying a non-axisymmetric magnetic field using the DIII-D in-vessel coils to modify the energy confinement time. In future burning plasma experiments as well as magnetic fusion energy power plants, various concepts have been proposed to control the fusion power. The fusion power in a power plant operating at high gain can be related to the plasma-stored energy and hence, is a strong function of the energy confinement time. Thus, an actuator, that modifies the confinement time, can be used to adjust the fusion power. In relatively low collisionality DIII-D discharges, the application of non-axisymmetric magnetic fields results in a decrease in confinement time and density pumpout. Gas puffing was used to compensate the density pumpout in the pedestal while control of the stored energy was demonstrated by the application of non-axisymmetric fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controller for thermostatically controlled loads

A system and method of controlling aggregated thermostatically controlled appliances (TCAs) for demand response is disclosed. A targeted load profile is formulated and a forecasted load profile is generated. The TCAs within an "on" or "off" control group are prioritized based on their operating temperatures. The "on" or "off" status of the TCAs is determined. Command signals are sent to turn on or turn off the TCAs.

25 ENERGY STORAGE↗

Intrinsic use control for system and use controlled component security

An Initialization Unit (IU) initiates an initial secure connection with an Intrinsic Use Control (IUC) Chip based on very large random numbers (VLRNs). The IUC Chip in turn initiates a secondary secure connection between it and one or more Use Controlled Components (UCCs). Polling by the IU allows confirmation of an ongoing secure connection, and also allows the IUC Chip to confirm the secondary secure connection to the UCCs. Removal or improper polling response from one of the UCCs results in a response from the IUC Chip that may include notification of tampering, or temporary or permanent discontinued operation of the offending UCC. Permanent discontinued operation may include destruction of the offending UCC, and cascaded discontinued operation of all other UCCs secured by the IUC Chip. A UCC may in turn be another nested layer of IUC Chips, controlling a corresponding layer of UCCs, ad infinitum.

97 MATHEMATICS AND COMPUTING↗

Intrinsic use control for system and use controlled component security

An Initialization Unit (IU) initiates an initial secure connection with an Intrinsic Use Control (IUC) Chip based on very large random numbers (VLRNs). The IUC Chip in turn initiates a secondary secure connection between it and one or more Use Controlled Components (UCCs). Polling by the IU allows confirmation of an ongoing secure connection, and also allows the IUC Chip to confirm the secondary secure connection to the UCCs. Removal or improper polling response from one of the UCCs results in a response from the IUC Chip that may include notification of tampering, or temporary or permanent discontinued operation of the offending UCC. Permanent discontinued operation may include destruction of the offending UCC, and cascaded discontinued operation of all other UCCs secured by the IUC Chip. A UCC may in turn be another nested layer of IUC Chips, controlling a corresponding layer of UCCs, ad infinitum.

97 MATHEMATICS AND COMPUTING↗

Intrinsic use control for system and use controlled component security

An Initialization Unit (IU) initiates an initial secure connection with an Intrinsic Use Control (IUC) Chip based on very large random numbers (VLRNs). The IUC Chip in turn initiates a secondary secure connection between it and one or more Use Controlled Components (UCCs). Polling by the IU allows confirmation of an ongoing secure connection, and also allows the IUC Chip to confirm the secondary secure connection to the UCCs. Removal or improper polling response from one of the UCCs results in a response from the IUC Chip that may include notification of tampering, or temporary or permanent discontinued operation of the offending UCC. Permanent discontinued operation may include destruction of the offending UCC, and cascaded discontinued operation of all other UCCs secured by the IUC Chip. A UCC may in turn be another nested layer of IUC Chips, controlling a corresponding layer of UCCs, ad infinitum.

Hart, Mark Miles↗

Method for controlling fiber growth in a laser heated pedestal growth system by controlling a laser power output, a pedestal feedstock rate of motion, and a draw rate

One or more embodiments relate to a method for controlling fiber growth and fiber diameter in a laser heated pedestal growth (LHPG) system so as to provide long, continuous single-crystal optical fibers of uniform diameter. The method generally provides three independent parameter feedback controls to control the molten zone height, laser power, and fiber drawing rates simultaneously in order to reduce the mismatch between instantaneous diameter changes and current diameter. The method permits the growth of fibers with non-uniform diameters along the fiber's length. The method also provides the capability to stop the LHPG system, remove the exhausted pedestal feedstock with a second pedestal feedstock, and restart the LHPG system to provide a continuous fiber.

Buric, Michael P.↗

Anomalies of the fissile mass control inside a controlled geometry leading to important safety issues - 14298

This article focuses on the very usual case of the fissile mass control inside a controlled geometry, whatever the fissile density in the fissile-moderator mixture is. Although this case is very usual (maximal loading of fissile material in a transport cask, maximal fissile content in a 'geometrically favorable' tank, etc.), some unexpected behaviors ('anomalies') may be met, leading to important nuclear criticality safety issues. This article will show the three following anomalies and the associated safety issues: - the 'non-smooth' variation of the minimum critical mass for a small variation of the geometry size (a cylinder case is considered throughout this article), - the very important differences in critical values, for intermediate-size geometries, between two fissile media having very close minimum critical masses and dimensions, - the change in the hierarchy of different fissile media when the size of the geometry changes. The next part of the article will demonstrate that these anomalies are, from a physics point of view, due to the nature of the fissile material and, from a methodology point of view, due to the fact that this 'Mass- Geometry Control' problem is generally solved without looking at the critical mass for the whole range of geometries. The latter happens because this whole resolution is not trivial and requires either a lot of calculations or human effort to estimate the mass limits as a function of the geometry. Another article will discuss this question of the 'whole' resolution of the problem. (authors)

42 ENGINEERING↗

Heterogeneous recurrence monitoring and control of nonlinear stochastic processes

Recurrence is one of the most common phenomena in natural and engineering systems. Process monitoring of dynamic transitions in nonlinear and nonstationary systems is more concerned with aperiodic recurrences and recurrence variations. However, little has been done to investigate the heterogeneous recurrence variations and link with the objectives of process monitoring and anomaly detection. Notably, nonlinear recurrence methodologies are based on homogeneous recurrences, which treat all recurrence states in the same way as black dots, and non-recurrence is white in recurrence plots. Heterogeneous recurrences are more concerned about the variations of recurrence states in terms of state properties (e.g., values and relative locations) and the evolving dynamics (e.g., sequential state transitions). This paper presents a novel approach of heterogeneous recurrence analysis that utilizes a new fractal representation to delineate heterogeneous recurrence states in multiple scales, including the recurrences of both single states and multi-state sequences. Further, we developed a new set of heterogeneous recurrence quantifiers that are extracted from fractal representation in the transformed space. To that end, we integrated multivariate statistical control charts with heterogeneous recurrence analysis to simultaneously monitor two or more related quantifiers. Experimental results on nonlinear stochastic processes show that the proposed approach not only captures heterogeneous recurrence patterns in the fractal representation but also effectively monitors the changes in the dynamics of a complex system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recovery Act: Federspiel Controls (now Vigilent) and State of California Department of General Services Data Center Energy Efficient Cooling Control Demonstration. Final technical project report

Eight State of California data centers were equipped with an intelligent energy management system to evaluate the effectiveness, energy savings, dollar savings and benefits that arise when powerful artificial intelligence-based technology measures, monitors and actively controls cooling operations. Control software, wireless sensors and mesh networks were used at all sites. Most sites used variable frequency drives as well. The system dynamically adjusts temperature and airflow on the fly by analyzing real-time demands, thermal behavior and historical data collected on site. Taking into account the chaotic interrelationships of hundreds to thousands of variables in a data center, the system optimizes the temperature distribution across a facility while also intelligently balancing loads, outputs, and airflow. The overall project will provide a reduction in energy consumption of more than 2.3 million kWh each year, which translates to $240,000 saved and a reduction of 1.58 million pounds of carbon emissions. Across all sites, the cooling energy consumption was reduced by 41%. The average reduction in energy savings across all the sites that use VFDs is higher at 58%. Before this case study, all eight data centers ran the cooling fans at 100% capacity all of the time. Because of the new technology, cooling fans run at the optimum fan speed maintaining stable air equilibrium while also expending the least amount of electricity. With lower fan speeds, the life of the capital investment made on cooling equipment improves, and the cooling capacity of the data center increases. This case study depicts a rare technological feat: The same process and technology worked cost effectively in eight very different environments. The results show that savings were achieved in centers with diverse specifications for the sizes, ages and types of cooling equipment. The percentage of cooling energy reduction ranged from 19% to 78% while keeping temperatures substantially within the limits recommended by the American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) for data center facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

User-Preference-Driven Model Predictive Control of Residential Building Loads and Battery Storage for Demand Response: Preprint

This paper presents a user-preference-driven home energy management system (HEMS) for demand response (DR) with residential building loads and battery storage. The HEMS is based on a multi-objective model predictive control algorithm, where the objectives include energy cost, thermal comfort, and carbon emission. A multi-criterion decision making method originating from social science is used to quickly determine user preferences based on a brief survey and derive the weights of different objectives used in the optimization process. Besides the residential appliances used in the traditional DR programs, a home battery system is integrated into the HEMS to improve the flexibility and reliability of the DR resources. Simulation studies have been performed on field data from a residential building stock data set. Appliance models and usage patterns were learned from the data to predict the DR resource availability. Results indicate the HEMS was able to provide a significant amount of load reduction with less than 20% prediction error in both heating and cooling cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗