Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controlled humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Microgravity Simulation Facility (MSF)

The Microgravity Simulator Facility (MSF) at Kennedy Space Center (KSC) was established to support visiting scientists for short duration studies utilizing a variety of microgravity simulator devices that negate the directional influence of the "g" vector (providing simulated conditions of micro or partial gravity). KSC gravity simulators can be accommodated within controlled environment chambers allowing investigators to customize and monitor environmental conditions such as temperature, humidity, CO2, and light exposure.

Microgravity↗

Impact of Controlled Storage Conditions on the Hydrolysis and Surface Morphology of Amorphous-UO 3

The hydration and morphological effects of amorphous (A)-UO 3 following storage under varying temperature and relative humidity have been investigated. This study provides valuable insight into U-oxide speciation following aging, the U-oxide quantitative morphological data set, and, overall, the characterization of nuclear material provenance. A-UO 3 was synthesized via the washed uranyl peroxide synthetic route and aged based on a 3-factor circumscribed central composite design of experiment. Target aging times include 2.57, 7.00, 14.0, 21.0, and 25.4 days, temperatures of 5.51, 15.0, 30.0, 45.0, and 54.5 °C, and relative humidities of 14.2, 30.0, 55.0, 80.0, and 95.8% were examined. Following aging, crystallographic changes were quantified via powder X-ray diffraction and an internal standard Rietveld refinement method was used to confirm the hydration of A-UO 3 to crystalline schoepite phases. The particle morphology from scanning electron microscopy images was quantified using both the Morphological Analysis of MAterials software and machine learning. Results from the machine learning were processed via agglomerative hierarchical clustering analysis to distinguish trends in morphological attributes from the aging study. Significantly hydrated samples were found to have a much larger, plate-like morphology in comparison to the unaged controls. Predictive modeling via a response surface methodology determined that while aging time, temperature, and relative humidity all have a quantifiable effect on A-UO 3 crystallographic and morphological changes, relative humidity has the most significant impact.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influences of Environmental Relative Humidity and Horizontal Scale of Subcloud Ascent on Deep Convective Initiation

This study examines two factors impacting initiation of moist deep convection: free-tropospheric environmental relative humidity (φ E ) and horizontal scale of subcloud ascent (R sub ), the latter exerting a dominant control on cumulus cloud width. A simple theoretical model is used to formulate a “scale selection” hypothesis: that a minimum R sub is required for moist convection to go deep, and that this minimum scale decreases with increasing φ E . Specifically, the ratio of R 2 sub to saturation deficit (1 - φ E ) must exceed a certain threshold value that depends on cloud-layer environmental lapse rate. Idealized, large-eddy simulations of moist convection forced by horizontally varying surface fluxes show strong sensitivity of maximum cumulus height to both φ E and R sub consistent with the hypothesis. Increasing R sub by only 300–400 m can lead to a large increase (>5 km) in cloud height. A passive tracer analysis shows that the bulk fractional entrainment rate decreases rapidly with R sub but depends little on φ E . However, buoyancy dilution increases as either R sub or φ E decreases; buoyancy above the level of free convection is rapidly depleted in dry environments when R sub is small. While deep convective initiation occurs with an increase in relative humidity of the near environment from moistening by earlier convection, the importance of this moisture preconditioning is inconclusive as it is accompanied by an increase in R sub . Overall, it is concluded that small changes to R sub driven by external forcing or by convection itself could be a dominant regulator of deep convective initiation.

54 ENVIRONMENTAL SCIENCES↗

Heat-pipe sensor for remote leveling

System gives level readings in inaccessible areas. Level sensor is equipped with three thermocouples used to measure temperature differences that arise when pipe is tilted. When platform on which pipe is resting is level, three thermocouple recordings are identical. When readings are unequal, platform is leveled by remote control. System can replace expensive optical equipment and can function in cold, vacuum, and hot humid environments that produce nonlinear expansion and contraction in conventional equipment. Other advantages include low cost, no moving parts, and operation in toxic environments.

Marshburn, J. P.↗

The Impact of Upper Tropospheric Humidity from Microwave Limb Sounder on the Midlatitude Greenhouse Effect

This paper presents an analysis of upper tropospheric humidity, as measured by the Microwave Limb Sounder, and the impact of the humidity on the greenhouse effect in the midlatitudes. Enhanced upper tropospheric humidity and an enhanced greenhouse effect occur over the storm tracks in the North Pacific and North Atlantic. In these areas, strong baroclinic activity and the large number of deep convective clouds transport more water vapor to the upper troposphere, and hence increase greenhouse trapping. The greenhouse effect increases with upper tropospheric humidity in areas with a moist upper troposphere (such as areas over storm tracks), but it is not sensitive to changes in upper tropospheric humidity in regions with a dry upper troposphere, clearly demonstrating that there are different mechanisms controlling the geographical distribution of the greenhouse effect in the midlatitudes.

Hu, Hua↗

Abstract - Belbas, Nicholas (EC2)

Originally, I was brought into the Design and Analysis Branch in the Crew and Thermal Systems to work on administrative tasks like archiving and scheduling. However, I ended up splitting my time between secretarial tasks and a technical project. My technical project was originally meant to be a wireless sensor package for the 20ft Spacecraft Thermal Vacuum Chamber in the B7 High Bay. I would be using a miniature wifi development board and a temperature/humidity sensor along with custom 3D modeling to accomplish this. However, after some discussion with my technical mentor, the plan was changed to a mobile autonomous self-charging sensor platform. A mobile platform will allow the sensors to be moved around without depressurizing the chamber. Also, the self-charging aspect of the package allows for almost unlimited time in the chamber. If the on-board battery runs low, the robot can easily be driven to its charging dock and continue to transmit while charging. The driving base is based around a Raspberry Pi 3 board with a 12C PMW DC Motor controller and a PWM controller driving two small gear motors. The sensor transmitter itself is a RHT03 temperature and humidity sensor and Cozir CO2 sensor connected to an ESP8266 Huzzah board. The power distribution system utilizes a pair of 3.7v 3600mah lipo batteries wired to Powerboost 500 boards. Also, the self-charging mechanism utilizes two 12v-max inductive charging coils wired into the same Powerboost boards as the battery. The Raspberry pi is running Python 3.3 for the driving base and Javascript MJPEG library for transmitting live video from the onboard camera. The sensor package is running Arduino-based C++ and the program capturing the data is running PyqtGraph Python and HTML. The shell of the robot itself is a 3D printed case that will (work in progress) snap together. The photo to the left shows the two halves separated from each other. The black shell contains the power distribution boards and connectors while the white shell contains the driving base and data systems.

Belbas, Nicholas↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗

Fabrication of bulk alumina structures with humidity sensing capabilities using direct ink write technique

Purpose The purpose of this study is to evaluate different 3D structures for humidity sensing that will enable the fabrication of complex geometries with high moisture sensitivity. Design/methodology/approach Humidity sensors based on alumina ceramics were fabricated using direct ink write (DIW) technique. Different engineered surface area, polymer binder ratio and post-processing treatment were considered to increase moisture sensitivity. Findings It was found that the binder ratio plays an important role in controlling the rheology of the paste during printing and determining the pore size after post-processing treatment. The sensibility of the fabricated humidity sensor was investigated by measuring its capacitance response toward relative humidity (RH) varying from 40% to 90% RH at 25°C. It is shown that using 3D lattice design, printed alumina humidity sensor could improve sensitivity up to 31.6 pF/RH%, over an order of magnitude higher than solid alumina. Originality/value Most of the alumina humidity sensors available are films in nature because of manufacturing difficulties, which limited its potential of higher sensitivity, and thus broader applications. In this paper, a novel 3D alumina humidity sensor was fabricated using DIW 3D printing technology.

Engineering↗

SeaWiFS Technical Report Series: SeaWiFS Calibration and Validation Quality Control Procedures - Volume 38

This document provides five brief reports that address several quality control procedures under the auspices of the Calibration and Validation Element (CVE) within the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project. Chapter 1 describes analyses of the 32 sensor engineering telemetry streams. Anomalies in any of the values may impact sensor performance in direct or indirect ways. The analyses are primarily examinations of parameter time series combined with statistical methods such as auto- and cross-correlation functions. Chapter 2 describes how the various onboard (solar and lunar) and vicarious (in situ) calibration data will be analyzed to quantify sensor degradation, if present. The analyses also include methods for detecting the influence of charged particles on sensor performance such as might be expected in the South Atlantic Anomaly (SAA). Chapter 3 discusses the quality control of the ancillary environmental data that are routinely received from other agencies or projects which are used in the atmospheric correction algorithm (total ozone, surface wind velocity, and surface pressure; surface relative humidity is also obtained, but is not used in the initial operational algorithm). Chapter 4 explains the procedures for screening level-, level-2, and level-3 products. These quality control operations incorporate both automated and interactive procedures which check for file format errors (all levels), navigation offsets (level-1), mask and flag performance (level-2), and product anomalies (all levels). Finally, Chapter 5 discusses the match-up data set development for comparing SeaWiFS level-2 derived products with in situ observations, as well as the subsequent outlier analyses that will be used for evaluating error sources.

Hooker, Stanford B.↗

Performance of three Trichogramma species as biocontrol agents on Spodoptera frugiperda eggs

Abstract Spodoptera frugiperda (JE Smith) (Lepidoptera: Noctuidae) is one of the most polyphagous and migratory pests posing a great threat to crops. The Trichogramma species (Hymenoptera: Trichogrammatidae) play an important role in dampening pest oscillations. In this study, we examined the performance of three egg parasitoids, T. chilonis , T. dendrolimi and T. pretiosum, to control S. frugiperda . Indoor experiments indicated significant differences in fecundity and female proportion between T. chilonis , T. dendrolimi and T. pretiosum . However, no significant differences were observed in developmental duration and female parasitic capacity. Field trials were carried out to clarify their control efficiency. Results showed that the parasitism rates of three parasitoids ranged from 10.7% to 31.4%, without significant differences. Moreover, field release of parasitoids resulted in significant decreases in damage rate (the ratio of infested plants) and damage index. A positive correlation was revealed between temperature (14.5–24.5 °C) and parasitism rate of T. chilonis . In contrast, the relative humidity (66% ~ 77%) did not affect their performance. Taken together, all three Trichogramma species can be used as potential agents to control S. frugiperda , which undoubtedly lays a solid foundation for their application.

Yang, Lei↗

Towards Learning-Based Architectures for Sensor Impact Evaluation in Building Controls

Advanced control algorithms for building systems are known to have significant potential in reducing energy consumption while optimizing thermal comfort. The success of such algorithms is critically contingent on several different types of sensor systems, which are in turn, used for continuous monitoring, identification and estimation of several important building states, such as temperatures, humidity, air quality, power consumption and occupancy status. Nonidealities in any of these sensors can lead to significant performance degradation of the control functionalities, and may lead to unwanted sub-optimal building operation. In this paper, we provide a simulation example with a high-fidelity building model, for a particular use-case of advanced optimization-based control in buildings, i.e., occupancy-based controls. We show how imperfections in occupancy sensing can offset performance. Subsequently, we discuss a novel learning-based architecture to efficiently evaluate the impact of sensor nonidealities for building systems, in context of advanced control algorithms.

Bhattacharya, Saptarshi↗

Compact Multi-Gas Monitor for Life Support Systems Control in Space: Evaluation Under Realistic Environmental Conditions

Advanced space life support systems require lightweight, low-power, durable sensors for monitoring critical gas components. A luminescence-based optical flow-through cell to monitor carbon dioxide, oxygen, and humidity has been developed and was demonstrated using bench top instrumentation under environmental conditions relevant to portable life support systems, including initially pure oxygen atmosphere, pressure range from 3.5 to 14.7 psi, temperature range from 50 F to 150 F, and humidity from dry to 100% RH and under liquid water saturation. This paper presents the first compact readout unit for these optical sensors, designed for the volume, power, and weight restrictions of a spacesuit portable Life support system and the analytical characterization of the optical sensors interrogated by the novel optoelectronic system. Trace gas contaminants in a space suit, originating from hardware and material off-gassing and crew member metabolism, are from many chemical families. The result is a gas mix much more complex than the pure oxygen fed into the spacesuit, which may interfere with gas sensor readings. The paper also presents an evaluation of optical sensor performance when exposed to the most significant trace gases reported to be found in spacesuits. The studies were conducted with the spacecraft maximum allowable concentrations for those trace gases and the calculated 8-hr. concentrations resulting from having no trace contaminant control system in the ventilation loop. Finally, a profile of temperature, pressure, humidity, and gas composition for a typical EVA mission has been defined, and the performance of sensors operated repeatedly under simulated EVA mission conditions has been studied.

Delgado, Jesus↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AN Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster at the Hanford AN tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 30−October 2, 2016, on a slipstream from the AN Exhauster under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AP Tank Farm Primary Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AP tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 24-26, 2016, on a slipstream from the AP exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

42 ENGINEERING↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ primary exhauster for the Hanford AY/AZ tank farms. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from August 26–28, 2016, on a slipstream from the 702-AZ exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1(SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and change-out frequency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗