Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Higher harmonic rotor blade pitch control

Tests of a model 'Reverse Velocity Rotor' system at high advance ratios and with twice-per-revolution cyclic pitch control were made under joint Navy-NASA sponsorship in the NASA, Ames 12 ft. pressure tunnel. The results showed significant gains in rotor performance at all advance ratios by using twice-per-revolution control. Detailed design studies have been made of alternative methods of providing higher harmonic motion including four types of mechanical systems and an electro-hydraulic system. The relative advantages and disadvantages are evaluated on the basis of stiffness, weight, volume, reliability and maintainability.

Ewans, J. R.↗

A Pressure Based Multigrid Procedure for the Navier-Stokes Equations on Unstructured Grids

We present details and performance of a pressure based multigrid solution procedure for the Navier-Stokes equations discretized on triangular grids. The discretization uses a control volume methodology, with linear inter-nodal variation of the flow variables. The use of the multigrid technique provides rapid and grid-independent rates of convergence. Three model driven cavity flows are computed, and the performance of the method at several grid densities and Reynolds numbers is reported. Representative flow fields characterizing the viscous eddies are also presented.

Jyotsna, R.↗

ICESat 2/ATLAS Onboard Flight Science Receiver Algorithms: Purpose, Process, and Performance

The Advanced Topographic Laser Altimetry System (ATLAS) is the sole instrument on the Ice, Cloud, and land Elevation Satellite 2 (ICESat-2). Without some method of reducing the transmitted data, the volume of ATLAS telemetry would far exceed the normal X-band downlink capability or require many more ground station contacts. The ATLAS Onboard Flight Science Receiver Algorithms (hereinafter Receiver Algorithms or Algorithms) control the amount of science data that is telemetered from the instrument, limiting the data volume by distinguishing surface echoes from background noise, and allowing the instrument to telemeter data from only a small vertical region about the signal. This is accomplished through the transfer of the spacecraft's location and attitude to the instrument every second, use of an onboard Digital Elevation Model, implementation of signal processing techniques, and use of onboard relief and surface type reference maps. Extensive ground testing verified the performance of the Algorithms. On-orbit analysis shows that the Algorithms are working as expected from the ground testing; they are performing well and meeting the mission requirements.

Algoritms, Signal Processing, Optimization, Flight↗

Structures including a measurement coating and methods of forming the same

A structure includes a substrate and a coating applied over the substrate, the coating containing particles sized between 30 and 250 micrometers. A proportion of the particles to the carrier is between 40 and 70 by volume percentage. In response to excitation of the structure by a controllable excitation source, a first instrument monitors behavior of the particles to determine a first condition of the structure thereby. In response to an absence of excitation of the structure by the controllable excitation source, a second instrument monitors behavior of the particles to determine a second condition of the structure thereby.

Ely, George Ray↗

Vibrational Power Flow Analysis of Rods and Beams

A new method to model vibrational power flow and predict the resulting energy density levels in uniform rods and beams is investigated. This method models the flow of vibrational power in a manner analogous to the flow of thermal power in a heat conduction problem. The classical displacement solutions for harmonically excited, hysteretically damped rods and beams are used to derive expressions for the vibrational power flow and energy density in the rod and beam. Under certain conditions, the power flow in these two structural elements will be shown to be proportional to the energy density gradient. Using the relationship between power flow and energy density, an energy balance on differential control volumes in the rod and beam leads to a Poisson's equation which models the energy density distribution in the rod and beam. Coupling the energy density and power flow solutions for rods and beams is also discussed. It is shown that the resonant behavior of finite structures complicates the coupling of solutions, especially when the excitations are single frequency inputs. Two coupling formulations are discussed, the first based on the receptance method, and the second on the travelling wave approach used in Statistical Energy Analysis. The receptance method is the more computationally intensive but is capable of analyzing single frequency excitation cases. The traveling wave approach gives a good approximation of the frequency average of energy density and power flow in coupled systems, and thus, is an efficient technique for use with broadband frequency excitation.

Wohlever, James Christopher↗

Invited Article: Radon and thoron intercomparison experiments for integrated monitors at NIRS, Japan

Inhalation of radon ({sup 222}Rn) and its short-lived decay products and of products of the thoron ({sup 220}Rn) series accounts for more than half of the effective dose from natural radiation sources. At this time, many countries have begun large-scale radon and thoron surveys and many different measurement methods and instruments are used in these studies. Consequently, it is necessary to improve and standardize technical methods of measurements and to verify quality assurance by intercomparisons between laboratories. Four international intercomparisons for passive integrating radon and thoron monitors were conducted at the NIRS (National Institute of Radiological Sciences, Japan). Radon exercises were carried out in the 24.4 m{sup 3} inner volume walk-in radon chamber that has systems to control radon concentration, temperature, and humidity. Moreover, the NIRS thoron chamber with a 150 dm{sup 3} inner volume was utilized to provide three thoron intercomparisons. At present, the NIRS is the only laboratory world-wide that has carried out periodic thoron intercomparison of passive monitors. Fifty laboratories from 26 countries participated in the radon intercomparison, using six types of detectors (charcoal, CR-39, LR 115, polycarbonate film, electret plate, and silicon photodiode). Eighteen laboratories from 12 countries participated in the thoron intercomparisons, using two etch-track types (CR-39 and polycarbonate) detectors. The tests were made under one to three different exposures to radon and thoron. The data presented in this paper indicated that the performance quality of laboratories for radon measurement has been gradually increasing. Results of thoron exercises showed that the quality for thoron measurements still needs further development and additional studies are needed to improve its measuring methods. The present paper provides a summary of all radon and thoron international intercomparisons done at NIRS from 2007 to date and it describes the present status on radon and thoron passive, one-time cycle monitors.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-221: A Novel Expansion Method for MRI Based Target Delineation in Prostate Radiotherapy

Purpose: To compare a novel bladder/rectum carveout expansion method on MRI delineated prostate to standard CT and expansion based methods for maintaining prostate coverage while providing superior bladder and rectal sparing. Methods: Ten prostate cases were planned to include four trials: MRI vs CT delineated prostate/proximal seminal vesicles, and each image modality compared to both standard expansions (8mm 3D expansion and 5mm posterior, i.e. ∼8mm) and carveout method expansions (5mm 3D expansion, 4mm posterior for GTV-CTV excluding expansion into bladder/rectum followed by additional 5mm 3D expansion to PTV, i.e. ∼1cm). All trials were planned to total dose 7920 cGy via IMRT. Evaluation and comparison was made using the following criteria: QUANTEC constraints for bladder/rectum including analysis of low dose regions, changes in PTV volume, total control points, and maximum hot spot. Results: ∼8mm MRI expansion consistently produced the most optimal plan with lowest total control points and best bladder/rectum sparing. However, this scheme had the smallest prostate (average 22.9% reduction) and subsequent PTV volume, consistent with prior literature. ∼1cm MRI had an average PTV volume comparable to ∼8mm CT at 3.79% difference. Bladder QUANTEC constraints were on average less for the ∼1cm MRI as compared to the ∼8mm CT and observed as statistically significant with 2.64% reduction in V65. Rectal constraints appeared to follow the same trend. Case-by-case analysis showed variation in rectal V30 with MRI delineated prostate being most favorable regardless of expansion type. ∼1cm MRI and ∼8mm CT had comparable plan quality. Conclusion: MRI delineated prostate with standard expansions had the smallest PTV leading to margins that may be too tight. Bladder/rectum carveout expansion method on MRI delineated prostate was found to be superior to standard CT based methods in terms of bladder and rectal sparing while maintaining prostate coverage. Continued investigation is warranted for further validation.

60 APPLIED LIFE SCIENCES↗

Optimization-based, property-preserving finite element methods for scalar advection equations and their connection to Algebraic Flux Correction

In this paper, we continue our efforts to exploit optimization and control ideas as a common foundation for the development of property-preserving numerical methods. Here we focus on a class of scalar advection equations whose solutions have fixed mass in a given Eulerian region and constant bounds in any Lagrangian volume. Our approach separates discretization of the equations from the preservation of their solution properties by treating the latter as optimization constraints. This relieves the discretization process from having to comply with additional restrictions and makes stability and accuracy the sole considerations in its design. A property-preserving solution is then sought as a state that minimizes the distance to an optimally accurate but not property-preserving target solution computed by the scheme, subject to constraints enforcing discrete proxies of the desired properties. Furthermore, we consider two such formulations in which the optimization variables are given by the nodal solution values and suitably defined nodal fluxes, respectively. A key result of the paper reveals that a standard Algebraic Flux Correction (AFC) scheme is a modified version of the second formulation obtained by shrinking its feasible set to a hypercube. In conclusion, we present numerical studies illustrating the optimization-based formulations and comparing them with AFC

97 MATHEMATICS AND COMPUTING↗

Sci—Thur PM: Planning and Delivery — 04: Respiratory margin derivation and verification in partial breast irradiation

Partial breast irradiation (PBI) following breast-conserving surgery is emerging as an effective means to achieve local control and reduce irradiated breast volume. Patients are planned on a static CT image; however, treatment is delivered while the patient is free-breathing. Respiratory motion can degrade plan quality by reducing target coverage and/or dose homogeneity. A variety of methods can be used to determine the required margin for respiratory motion in PBI. We derive geometric and dosimetric respiratory 1D margin. We also verify the adequacy of the typical 5 mm respiratory margin in 3D by evaluating plan quality for increasing respiratory amplitudes (2–20 mm). Ten PBI plans were used for dosimetric evaluation. A database of volunteer respiratory data, with similar characteristics to breast cancer patients, was used for this study. We derived a geometric 95%-margin of 3 mm from the population respiratory data. We derived a dosimetric 95%-margin of 2 mm by convolving 1D dose profiles with respiratory probability density functions. The 5 mm respiratory margin is possibly too large when 1D coverage is assessed and could lead to unnecessary normal tissue irradiation. Assessing margins only for coverage may be insufficient; 3D dosimetric assessment revealed degradation in dose homogeneity is the limiting factor, not target coverage. Hotspots increased even for the smallest respiratory amplitudes, while target coverage only degraded at amplitudes greater than 10 mm. The 5 mm respiratory margin is adequate for coverage, but due to plan quality degradation, respiratory management is recommended for patients with respiratory amplitudes greater than 10 mm.

60 APPLIED LIFE SCIENCES↗

SU-F-T-203: High Dose Definitive Proton Therapy with Integrated Boost to Hypoxic Subvolumes Determined by [18F]-Fluoromisonidazole (FMISO) PET/CT for Patients with Recurrent Chordomas Using Intensity Modulated Proton Therapy (IMPT)

Purpose: Recurrent chordomas are difficult to control locally. This dosimetric study investigates the feasibility of dose escalation to hypoxic regions, visualized on FMISO-PET, while respecting the dose constraints to the neighboring normal tissues/organs. We propose to deliver a higher dose to the areas of hypoxia (84.5Gy) using IMPT with the goal of improving local control. Methods: We currently have four patients with hypoxic subvolumes (HSV) greater than 10cc from the FMISO-PET image. The HSV was delineated based on the standardized uptake values of greater than 1.4 times of the muscle mean. Gross tumor volume (GTV) was delineated using planning CT with the assistance of MRI fusion. The dose scheme is 50.4Gy RBE to CTV in 1.8Gy fractions, followed by an integrated boost of 27.0Gy RBE to GTV in 1.8Gy fractions and 34.5Gy RBE to HSV in 2.3Gy fractions. IMPT integrated boost plans were optimized with multi-criteria optimization (MCO). Posterior-anterior beam angles were used for these plans. We also propose using two posterior oblique fields to boost HSV to spare the skin folding. A medium spot size with 8mm to 15 mm (σ) in air at isocenter with energies from 220 MeV down to 90 MeV was used. Aperture was used for the medium spot size. A small spot size of 2.5 mm to 4.5 mm (σ) in air at isocenter with energies from 240 MeV down to 70 MeV was also proposed. Target coverage and dose to OARs were evaluated. Results: For the sacral chordoma patient that has been planned, the target homogeneity index is 3.2% for HSV, 55.9% for CTV and 11.9% for GTV. The max dose is 77GyRBE to rectum, 86.2GyRBE to sacral nerves and 73.9GyRBE to cauda equina. Conclusion: IMPT with integrated high dose boost to HSV determined from FMISO PET image is feasible. OAR dose constraints were met.

60 APPLIED LIFE SCIENCES↗

General Applications for Hamilton Vantage (GenApps for Vantage) v0.6.1

General applications for Hamilton Vantage is a flexible liquid handling method used to automate the most widely applicable types of automated liquid transfers. General applications can also be used as a tool to onboard new fully-automated workflows by breaking them down step by step into single transfers. The goal of General Applications is to make using the Hamilton Vantage liquid handler as easy & practical as using a handheld pipette for the end user. The software supports plate-to-plate transfers for a variety of method types including: Stamp: One-to-One, Stamp: One-To-Many, Split, Combine, Hitpick, and Qtray plating. General Applications eliminates the need for automation engineers to customize individual methods for each new workflow that gets onboarded. Steps can be customized within GenApps according to the needs of the researcher. The software utilizes a GUI to prompt the users to input variables – Allowing for flexible control over plate types, transfer volumes, number of replicates, tip types, liquid classes, mixing steps, aspiration/dispense heights and more. General Applications also generates a deck image and setup instructions to guide the researcher on how to load the deck and start the instrument.

Yoder, Sam↗

Current status of tritium calorimetry at TLK

Inside a tritium facility, calorimetry is an important analytical method as it is the only reference method for accountancy (it is based on the measurement of the heat generated by the radioactive decay). Presently, at Tritium Laboratory Karlsruhe (TLK), 4 calorimeters are in operation, one of isothermal type and three of inertial guidance control type (IGC). The volume of the calorimeters varies between 0.5 and 20.6 liters. About two years ago we started an extensive work to improve our calorimeters with regard to reliability and precision. We were forced to upgrade 3 of our 4 calorimeters due to the outdated interfaces and software. This work involved creating new LabView programs driving the devices, re-tuning control loops and replacing obsolete hardware components. In this paper we give a review on the current performance of our calorimeters, comparing it to recently available devices from the market and in the literature. We also show some ideas for a next generation calorimeter based on experiences with our IGC calorimeters and other devices reported in the literature. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Injection Principles from Combustion Studies in a 200-Pound-Thrust Rocket Engine Using Liquid Oxygen and Heptane

The importance of atomizing and mixing liquid oxygen and heptane was studied in a 200-pound-thrust rocket engine. Ten injector elements were used with both steel and transparent chambers. Characteristic velocity was measured over a range of mixture ratios. Combustion gas-flow and luminosity patterns within the chamber were obtained by photographic methods. The results show that, for efficient combustion, the propellants should be both atomized and mixed. Heptane atomization controlled the combustion rate to a much larger extent than oxygen atomization. Induced mixing, however, was required to complete combustion in the smallest volume. For stable, high-efficiency combustion and smooth engine starts, mixing after atomization was most promising.

Heidmann, M. F.↗

Estimating the Rate of Solids Accumulation in Double Shell Tanks - 17093

This project describes a method of estimating the rate of solids accumulation in Low Activity Waste Pretreatment System (LAWPS) Double Shell Tanks (DSTs) from solids entrainment and precipitation in order to identify and recommend appropriate control measures to protect LAWPS feed schedules. By comparing various volume fraction solids in transfer volumes with the available tank storage needed to maintain LAWPS feed schedules the number of possible transfers before solids removal is necessary can be determined. A family of curves spanning the range of values of volume fraction solids most frequently observed in grab samples was charted to show the transfer batch number at which point accumulated solids inhibit sufficient storage for waste feed schedules and thereby warrant solids removal. Results of this study indicate that in order to preclude solids removal activities during the LAWPS waste transfers, volume fraction settled solids levels in LAWPS transfers are required to stay below 0.0133 and 0.0183 for Feed Staging Tank 1 and 2, respectively. Results of this study show that the rate of solids accumulation will exceed the requirement, and therefore solids removal capability for LAWPS DSTs upgrades is required. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-209: Multicriteria Optimization Algorithm for Intensity Modulated Radiation Therapy Using Pencil Proton Beam Scanning

Purpose: To provide a multicriteria optimization algorithm for intensity modulated radiation therapy using pencil proton beam scanning. Methods: Intensity modulated radiation therapy using pencil proton beam scanning requires efficient optimization algorithms to overcome the uncertainties in the Bragg peaks locations. This work is focused on optimization algorithms that are based on Monte Carlo simulation of the treatment planning and use the weights and the dose volume histogram (DVH) control points to steer toward desired plans. The proton beam treatment planning process based on single objective optimization (representing a weighted sum of multiple objectives) usually leads to time-consuming iterations involving treatment planning team members. We proved a time efficient multicriteria optimization algorithm that is developed to run on NVIDIA GPU (Graphical Processing Units) cluster. The multicriteria optimization algorithm running time benefits from up-sampling of the CT voxel size of the calculations without loss of fidelity. Results: We will present preliminary results of Multicriteria optimization for intensity modulated proton therapy based on DVH control points. The results will show optimization results of a phantom case and a brain tumor case. Conclusion: The multicriteria optimization of the intensity modulated radiation therapy using pencil proton beam scanning provides a novel tool for treatment planning. Work support by a grant from Varian Inc.

60 APPLIED LIFE SCIENCES↗

Predictors of Survival in Contemporary Practice After Initial Radiosurgery for Brain Metastases

Purpose: The number of brain metastases (BM) is a major consideration in determining patient eligibility for stereotactic radiosurgery (SRS), but the evidence for this popular practice is equivocal. The purpose of this study was to determine whether, following multivariate adjustment, the number and volume of BM held prognostic significance in a cohort of patients initially treated with SRS alone. Methods and Materials: A total of 251 patients with primary malignancies, including non-small cell lung cancer (34%), melanoma (30%), and breast carcinoma (16%), underwent SRS for initial treatment of BM. SRS was used as the sole management (62% of patients) or was combined with salvage treatment with SRS (22%), whole-brain radiation therapy (WBRT; 13%), or resection (3%). Median follow-up time was 9.4 months. Survival was determined using the Kaplan-Meier method. Cox regression was used to assess the effects of patient factors on distant brain failure (DBF), local control (LC), and overall survival (OS). Results: LC at 1 year was 94.6%, and median time to DBF was 10 months. Median OS was 11.1 months. On multivariate analysis, statistically significant predictors of OS were presence of extracranial disease (hazard ratio [HR], 4.2, P<.001), total tumor volume greater than 2 cm{sup 3} (HR, 1.98; P<.001), age ≥60 years (HR, 1.67; P=.002), and diagnosis-specific graded prognostic assessment (HR, 0.71; P<.001). The presence of extracranial disease was a statistically significant predictor of DBF (HR, 2.15), and tumor volume was predictive of LC (HR, 4.56 for total volume >2 cm{sup 3}). The number of BM was not predictive of DBF, LC, or OS. Conclusions: The number of BM is not a strong predictor for clinical outcomes following initial SRS for newly diagnosed BM. Other factors including total treatment volume and systemic disease status are better determinants of outcome and may facilitate appropriate use of SRS or WBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Apollo/Skylab suit program management systems study. Volume 2: Cost analysis

The business management methods employed in the performance of the Apollo-Skylab Suit Program are studied. The data accumulated over the span of the contract as well as the methods used to accumulate the data are examined. Management methods associated with the monitoring and control of resources applied towards the performance of the contract are also studied and recommended upon. The primary objective is the compilation, analysis, and presentation of historical cost performance criteria. Cost data are depicted for all phases of the Apollo-Skylab program in common, meaningful terms, whereby the data may be applicable to future suit program planning efforts.

Source record↗