Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Accelerated aging of all-inorganic, interface-stabilized perovskite solar cells

To understand degradation routes and improve the stability of perovskite solar cells (PSCs), accelerated aging tests are needed. Here, we use elevated temperatures (up to 110°C) to quantify the accelerated degradation of encapsulated CsPbI 3 PSCs under constant illumination. Incorporating a two-dimensional (2D) Cs 2 PbI 2 Cl 2 capping layer between the perovskite active layer and hole-transport layer stabilizes the interface while increasing power conversion efficiency of the all-inorganic PSCs from 14.9 to 17.4%. Devices with this 2D capping layer did not degrade at 35°C and required >2100 hours at 110°C under constant illumination to degrade by 20% of their initial efficiency. Degradation acceleration factors based on the observed Arrhenius temperature dependence predict intrinsic lifetimes of 51,000 ± 7000 hours (>5 years) operating continuously at 35°C.

Science & Technology - Other Topics↗

Rational design of Lewis base molecules for stable and efficient inverted perovskite solar cells

Lewis base molecules that bind undercoordinated lead atoms at interfaces and grain boundaries (GBs) are known to enhance the durability of metal halide perovskite solar cells (PSCs). Using density functional theory calculations, we found that phosphine-containing molecules have the strongest binding energy among members of a library of Lewis base molecules studied herein. Experimentally, we found that the best inverted PSC treated with 1,3-bis(diphenylphosphino)propane (DPPP), a diphosphine Lewis base that passivates, binds, and bridges interfaces and GBs, retained a power conversion efficiency (PCE) slightly higher than its initial PCE of ~23% after continuous operation under simulated AM1.5 illumination at the maximum power point and at ~40°C for >3500 hours. DPPP-treated devices showed a similar increase in PCE after being kept under open-circuit conditions at 85°C for >1500 hours.

14 SOLAR ENERGY↗

Stabilized hole-selective layer for high-performance inverted p-i-n perovskite solar cells

P-i-n geometry perovskite solar cells (PSCs) offer simplified fabrication, greater amenability to charge extraction layers, and low-temperature processing over n-i-p counterparts. Self-assembled monolayers (SAMs) can enhance the performance of p-i-n PSCs but ultrathin SAMs can be thermally unstable. Here we report a thermally robust hole-selective layer comprised of nickel oxide (NiO x ) nanoparticle film with a surface-anchored (4-(3,11-dimethoxy-7H-dibenzo[c,g]carbazol-7-yl)butyl)phosphonic acid (MeO-4PADBC) SAM that can improve and stabilize the NiO x /perovskite interface. The energetic alignment and favorable contact and binding between NiO x /MeO-4PADBC and perovskite reduced the voltage deficit of PSCs with various perovskite compositions and led to strong interface toughening effects under thermal stress. The resulting 1.53–electron-volt devices achieved 25.6% certified power conversion efficiency and maintained >90% of their initial efficiency after continuously operating at 65 degrees Celsius for 1200 hours under 1-sun illumination.

14 SOLAR ENERGY↗

Long-Term Stability in Perovskite Solar Cells Through Atomic Layer Deposition of Tin Oxide

Robust contact schemes that boost stability and simplify the production process are needed for perovskite solar cells (PSCs). We codeposited perovskite and hole-selective contact while protecting the perovskite to enable deposition of SnOx/Ag without the use of a fullerene. The SnOx, prepared through atomic layer deposition, serves as a durable inorganic electron transport layer. Tailoring the oxygen vacancy defects in the SnOx layer led to power conversion efficiencies (PCEs) of >25%. Our devices exhibit superior stability over conventional p-i-n PSCs, successfully meeting several benchmark stability tests. They retained >95% PCE after 2000 hours of continuous operation at their maximum power point under simulated AM1.5 illumination at 65degrees C. Additionally, they boast a certified T97 lifetime exceeding 1000 hours.

c60↗

A Self-Sustained CPS Design for Reliable Wildfire Monitoring

Continuous monitoring of areas nearby the electric grid is critical for preventing and early detection of devastating wildfires. Existing wildfire monitoring systems are intermittent and oblivious to local ambient risk factors, resulting in poor wildfire awareness. Ambient sensor suites deployed near the gridlines can increase the monitoring granularity and detection accuracy. However, these sensors must address two challenging and competing objectives at the same time. First, they must remain powered for years without manual maintenance due to their remote locations. Second, they must provide and transmit reliable information if and when a wildfire starts. The first objective requires aggressive energy savings and ambient energy harvesting, while the second requires continuous operation of a range of sensors. To the best of our knowledge, this paper presents the first self-sustained cyber-physical system that dynamically co-optimizes the wildfire detection accuracy and active time of sensors. The proposed approach employs reinforcement learning to train a policy that controls the sensor operations as a function of the environment (i.e., current sensor readings), harvested energy, and battery level. Here, the proposed cyber-physical system is evaluated extensively using real-life temperature, wind, and solar energy harvesting datasets and an open-source wildfire simulator. In long-term (5 years) evaluations, the proposed framework achieves 89% uptime, which is 46% higher than a carefully tuned heuristic approach. At the same time, it averages a 2-minute initial response time, which is at least 2.5× faster than the same heuristic approach. Furthermore, the policy network consumes 0.6 mJ per day on the TI CC2652R microcontroller using TensorFlow Lite for Micro, which is negligible compared to the daily sensor suite energy consumption.

54 ENVIRONMENTAL SCIENCES↗

Spot-Checking for Reliable Quantum Communications

We demonstrate a spot-checking approach for real-time drift estimation and mitigation in continuously operating quantum links. Using polarization-entangled photon pairs, we achieve stable 16-hour operation, validating efficient, minimally invasive monitoring of quantum-network performance.

Zhang, Yanbao [ORNL] (ORCID:0000000245530561)↗

Effects of 9.5 Years of Whole-Soil Warming on the Fatty Acid and n-Alkanes Composition in Bulk Soil and Density Fractions at Blodgett Experimental Forest, California, USA

Original data of molecular data (fatty acids and n-alkanes) including concentrations and calculated molecular proxies in a whole-soil warming experiment at the Blodgett Forest Research Station after 9.5 years of warming. The study site has a Mediterranean climate with annual average temperature of 12.5 ℃ and annual average precipitation of 1774 mm. The study site is characterized by a mesic Ultic Alfisol formed from granitic parent material, corresponding to a Dystric Cambisol under the World Reference Base for Soil Resources (WRB) classification system. Experimental warming is applied throughout the soil profile to a depth of 1 m using vertically embedded heating cables that raise soil temperature by 4 °C relative to ambient conditions. Soil samples were collected on 1 May 2023, after the experiment had been operating continuously for about 9.5 years since its initiation in January 2014.The data has been processed from raw data and cross-validated by other peers. The dataset includes: - Bulk_Fattyacid_9.5-year_Soil_Warming_Blodgett, California, USA: fatty acid concentrations and proxies including Carbon Preference Index (CPI) and Average Chain Length (ACL) of bulk soil organic carbon; - Fractions_Fattyacid_9.5-year_Soil_Warming_Blodgett, California, USA: fatty acid concentrations and proxies including CPI and ACL of free particulate organic matter (fPOM) and mineral-associated organic matter (MAOM); - Bulk_Alkanes_9.5-year_Soil_Warming_Blodgett, California, USA: n-alkanes concentrations and proxies including CPI and ACL of bulk soil organic carbon; - Fractions_Alkanes_9.5-year_Soil_Warming_Blodgett, California, USA: n-alkanes concentrations and proxies including CPI and ACL of fPOM and MAOM; - n-Alkanes_All_Monomer_Concentration_9.5-year_Soil_Warming_Blodgett, California, USA: concentration of all the n-alkane monomers identified and integrated for bulk soil, fPOM and MAOM; - Fattyacid_All_Monomer_Concentration_9.5-year_Soil_Warming_Blodgett, California, USA: concentration of all the fatty acid monomers including diacids identified and integrated for bulk soil, fPOM, and MAOM. All data are provided in CSV format and can be viewed using Microsoft Excel. We specifically look at fatty acids (FA) and n-alkanes in bulk soil, fPOM and MAOM and calculated molecular proxies such as CPI and ACL to understand the source of oragnic carbon (with ACL) and degree of decomposition (CPI) of each soil fraction. Due to lack of long-chain fatty acids (carbon number ⩾ 20), microorganism-derived organic carbon is characterized by shorter ACL in comparison to plant-derived organic carbon. Fresh SOC is characterized by even-over-odd dominance for fatty acids and odd-over-even dominance for n-alkanes. Therefore, CPI indicates whether soil organic carbon (SOC) represents fresh input (CPI > 10) or is strongly decomposed (close to 1). The research questions should be then, after 9.5-year warming: 1. whether the relative contribution between microorganism-derived and plant-derived SOC in each soil fraction? 2. whether fPOM became more decomposed whereas MAOM remained relatively persistent in each soil fraction across the soil depth?

Carbon↗

AmeriFlux US-GL2 Granite Island

This is the AmeriFlux version of the carbon flux data for the site US-GL2 Granite Island. Site Description - Granite Island is a small island on Lake Superior approximately 10 miles due north of Marquette, Michigan. It is roughly 6.5 miles from shore and is occupied by a lighthouse, bell tower, Coast Guard light tower, and other small structures. A flux tower to measure H, LE, and meteorological data was installed atop the bell tower in July of 2009 and has been in continuous operation since then (aside from occasional power outages or other sources of data loss). CO2 measurements were added to the flux tower in October of 2010.

Lenters, John [University of Michigan Biological S↗

Ice-slurry production for solar-ice systems using supercooling with an in-stream crystallizer

Using ice slurry produced from supercooled water with an in-stream crystallizer opens a new path for solarice systems, increasing efficiency and reducing investment cost compared to ice-on-coil systems. Power needs are decoupled from the stored energy since the heat exchangers are not evenly distributed in the ice storage vessel but directly placed as the heat pump evaporator, which depends on the heat pump capacity and not on the ice storage volume. The novel ice storage design can serve as a heat source for a heat pump, where its evaporator is used to supercool water below 0 °C, or for refrigeration. The supercooled water at a temperature around −2 °C, maintained in a meta-stable liquid state, is triggered to nucleate in an in-stream crystallizer. The current design of the ice crystallizer allows for continuous operation of the system and scalability. Experimental results obtained with a gasketed plate heat exchanger used to supercool water and an in-stream crystallizer operated at a power of up to 6.5 kW are presented.

Thamm, Ann-Katrin↗

Lifetime extension of legacy CEBAF LLRF hardware

A significant portion of the Low-Level Radio Frequency (LLRF) hardware in Jefferson Lab’s CEBAF is from the original construction of the facility using 1980’s CAMAC technology. Of the fifty-three zones in CEBAF, thirty-six of them are legacy hardware. The age of the legacy system has led to difficulties in maintaining the hardware due to parts going obsolete without suitable drop in replacements. Continued operation of the legacy system is required as the installation of LLRF 3.0 systems is costly and cannot be completed in a short period of time with the available resources. The most pressing failure in the legacy system was a failing buffer card, which is responsible for communication between the EPICs network and individual RF control modules. A new buffer card was designed as a transparent, drop in, replacement so that upgrades are simply a matter of swapping the existing legacy hardware. This buffer card upgrades a single point failure component and promises to extend the operable lifetime of CEBAF’s legacy systems.

Accelerator Physics↗

Modeling, Design, and Testing of a Novel Biphasic Solvent-Enabled Absorption System for Post-Combustion Carbon Capture

A novel absorption process enabled by a new class of biphasic solvents for post-combustion carbon capture (BiCAP) is presently being developed at the University of Illinois at Urbana-Champaign. The new biphasic solvents are water-lean solvent blends that develop dual liquid phases with the absorbed CO2 highly enriched in one of the phases. These solvents are superior in CO2 capacity and have high thermal and oxidative stability compared to MEA. The BiCAP technology features a unique process configuration of multi-stage CO2 absorption and liquid–liquid phase separation during CO2 absorption, allowing continual separation and removal of the CO2-enriched liquid phase for maintaining low solvent viscosity and a fast absorption rate. A 40 kWe-scale skid has recently been constructed at the Abbott Power Plant in Champaign, IL, to test the BiCAP solvent in continuous operation with a slipstream of real post-combustion flue gas. Along with improvements in the stripping configuration including cold feed bypass, the process is expected to achieve a minimum reboiler duty of 2,210 kJ/kg CO2 captured at a stripper operating pressure of 6 bar.

20 FOSSIL-FUELED POWER PLANTS↗

Solvent Hold Tank Sample Results for MCU-19-366- 367-368 (April 2019), MCU-19-469-470-471 (May 2019), MCU-19-524-525-526 (June 2019): Quarterly Report

A trend summary of three sets of Solvent Hold Tank (SHT) monthly samples MCU-19-366-367-368 (April), MCU-19-469-470-471 (May), and MCU-19-524-525-526 (June) are reported. Most of the conclusions are based on the June SHT sample (MCU-19-524-525-526). Analyses of the June SHT sample (MCU-19-524- 525-526) indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L respectively) by 4% and 2% respectively but consistent with previously observed levels during normal runs. The Suppressor (N,N’,N”– tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the March 2019 measurement to 793 mg/L, which is above the minimum recommended concentration (479 mg/L). The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected presence of phthalates at a few ppm. The impurity concentration was highest in the April sample and consistently detected in the May and June samples (but always registered as a few ppm or less). Another impurity observed in the samples was mercury. Based on the June SHT sample, up to 25 ± 5 micrograms of mercury per mL of solvent was detected (as the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10. The gamma concentration (~2.90E4 dpm/mL) measured in the June 2019 SHT samples was consistent with previous values observed when the Modular Caustic-Side Solvent Extraction Unit (MCU) was operating continuously (for example, between December 2016 and January 2017). Statistical analysis of the different analytical methods detected a bias between the FT-HNMR and the High Performance Liquid Chromatography (HPLC) methods when measuring the MaxCalix and Modifier concentrations; the FT-HNMR gave a higher concentration possibly due to peak overlapping in the measured data. A bias was detected when measuring total mercury by the DMA method versus the XRF method with the XRF method reported higher mercury concentrations. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Future of LANSCE [Slides]

LANSCE is a NNSA Center for Materials and Nuclear Research. An aging stockpile presents unique challenges in materials and nuclear science. The grand challenge of a predictive materials capability includes design to manufacture and born certified. This requires capability to study manufacture to structure relationships and capability to study structure to performance relationships. LANSCE has the capabilities needed for this mission. We leverage our capability to provide broader benefit to the Nation including production of medical isotopes, industrial irradiation facility for electronics certification, and fundamental materials and physics research. The LANSCE linear accelerator is nearly 50 years old. The severity of maintenance issues is increasing. We must reinvest in LANSCE to ensure mission delivery into the future. We must develop new capability to be responsive to changing mission needs. Ultimately this will require a Dynamic Mesoscale Materials Science Capability. Now we must develop a pathway to MaRIE that ensures continued operation of LANSCE.

43 PARTICLE ACCELERATORS↗

2020 State of the Science Report, Chapter 10: Environmental Monitoring Technologies and Techniques for Detecting Interactions of Marine Animals with Turbines

The greatest potential risk from turbine operation continues to be perceived by regulators and other stakeholders to be that of marine animals colliding with turbine blades. These potential interactions are the most difficult to observe using common oceanographic instruments and must be undertaken in parts of the ocean where fast moving water and high waves make studies challenging. However, our collective understanding of the effects of marine renewable energy (MRE) devices on marine animals and their habitats has improved since the publication of the 2016 State of the Science report. https://tethys.pnnl.gov/publications/state-of-the-science-2020-chapter-10-environmental-monitoring

16 TIDAL AND WAVE POWER↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast Data Processing for Hyperspectral Sensors on Small Platforms

Hyperspectral imaging is a very promising technology for nuclear proliferation detection. However, due to size and weight restrictions, small hyperspectral platforms such as satellites and small drones lack the on-board computing resources for accurate, real-time analysis of the enormous flow of data that a continuously operating hyperspectral sensor generates. This severely limits satellite systems, which can collect far more data than what they can telemeter, and hinders the ability of all platforms to adapt their missions on the fly in response to observations. This program addresses the hyperspectral data processing challenge through development of new, fast and accurate algorithms that produce data products in real time. The algorithms circumvent the major computational bottlenecks in existing processing streams, and would be incorporated in lightweight, power-efficient single-board computer systems. The toolkit of fast algorithms will be immediately useful in current and future hyperspectral systems being built by the Government and by private industry, including drone-based systems and satellite constellations that acquire timely global imagery.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Financing Microgrids in the Federal Sector

Recent high-impact events such as hurricanes and wildfires highlight the need for energy system resilience. One potential impact of these events is the loss of utility grid power to federal sites, negatively affecting the ability to carry out their missions. Depending on the need to sustain critical functions, it may be important to continue operations during an outage of the electric grid, or at least have power restored quickly after the event. One approach to addressing this need is through a microgrid. Microgrids can provide a more reliable solution than the traditional approach of using a backup generator at individual buildings. A microgrid can enhance a site’s electrical power system during normal operations, as well as provide reliable backup power to critical loads when electric utility power is interrupted. Many times, certain components of a microgrid (and potentially the entire system) can be justified economically and paid for out of energy savings or avoided costs. In cases where savings can cover the project costs, one of several privately financed procurement mechanisms may be used to implement the project. Procurement options available to all federal agencies include utility energy services contracts (UESC), energy savings performance contracts (ESPC), and utility services contracts (USC); other mechanisms such as a power purchase agreement (PPA), enhanced use lease (EUL), and utility privatization (UP) may also be useful to agencies that have the authority to use them. Implementing a microgrid in a comprehensive effort that also includes energy efficiency can provide an important savings component, while reducing power requirements for critical loads, thus reducing the cost of the microgrid and associated distributed energy resources (DER). However, it can be difficult to achieve enough savings and avoided costs to cover the entire microgrid system, so leveraging these avoided costs in combination with appropriated funds may be necessary to implement the full project. When a site is deciding if a microgrid is the best solution, activities early in the process include identifying critical loads and existing DERs, conversations with the local electric utility, and implementation options that work best for the agency and site. This paper explores procurement options and agreements that may be useful to federal agencies interested in implementing microgrids at their sites. Microgrid complexities, implementation considerations, and suggestions to get started are also discussed. This information will be most useful to agencies when they are exploring electric energy system resilience options and/or considering different procurement options to meet their needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Detritiation Strategies for Mitigating Tritium Releases

Tritium confinement is performed using different barriers to minimize releases to the environment. Primary confinement is usually performed by process piping and components, secondary confinement typically by inerted gloveboxes connected to a continuously operating tritium stripper system. Some facility designs employ tertiary tritium confinement by using process room confinement with a tritium stripper system activated after an accident to further mitigate tritium releases to the environment. Secondary confinement of some tritium systems such as radiation-hardened or shielded-cell enclosures are not easily achieved using designs for inerted glovebox. These enclosures can be challenging to seal for secondary tritium confinement due to heating, ventilation, and air conditioning (HVAC) needs for temperature control, as well as feedthroughs for equipment and instrumentation, are potential pathways for tritium leaks or loses. Additional tritium leak paths can be created in secondary confinement enclosures due to a Design Basis Accident (DBA) seismic event. These new, larger tritium leak rates from the DBA event are usually not part of the stripper system design basis so all tritium released to the secondary confinement enclosure is assumed released to the environment. Detritiation strategies for shielded enclosures and/or gloveboxes with significant leak rates are necessary to minimize off-site radiological dose consequences. To address this, the relationship between the confinement system leak rate and stripper system (recirculating) flow rate was evaluated to meet prescribed maximum allowable environmental tritium emissions from the event. The simple analysis described assumes a constant leak rate from the confinement system (i.e. shielded enclosure or glovebox) while a recirculating stripper system strips tritium from the system– a competition between tritium release and tritium recovery. At a high level, the resulting expression summarizes the relationship between system leak rate (F L ) and stripper flow rate (F S ) relative to allowable tritium release (Q A ) and initial tritium release (Q 0 ): $\frac{F_L}{F_s}$ ≈ $\frac{Q_A}{Q_0}$. This report derives the relationship between these parameters, examines the impact of finite stripping times followed by purging of the stripped volume. The analysis provides example results for up to 30 gram tritium releases: the maximum tritium inventory of a Hazard Category III (Department of Energy) Nuclear Facility. The detritiation model presented represents a high-level analysis of tritium recovery versus losses for “leaky” confinement enclosures such as shielded cells after large tritium releases. Key parameters for doing the analyses are the system leak rate, stripper flow rate, initial tritium release, and allowable tritium release values. The analyses show a proportional decrease in releases with reduction in initial tritium release but a non-linear increase in tritium recovery with increased stripper flow rate or reduced leak-rate. The analyses also apply to glovebox confinement systems which could have significant increases in leak rates after a DBA. The analysis recognizes but does not include tritium absorption followed by re-emission from the walls of the confinement volume – an analysis which could be pursued in future studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗