Application of Spectroscopic Doppler Velocimetry for Measurement of Streamwise Vorticity

A spectroscopic Doppler velocimetry technique has been developed for measuring two transverse components of velocity and hence streamwise vorticity in free jet flows. The nonintrusive optical measurement system uses Mie scattering from a 200 mW green continuous-wave laser interacting with dust and other tracer particulates naturally present in the air flow to measure the velocities. Scattered light is collected in two opposing directions to provide measurements of two orthogonal velocity components. An air-spaced Fabry-Perot interferometer is used for spectral analysis to determine the optical frequency shift between the incident laser light and the Mie scattered light. This frequency shift is directly proportional to the velocity component in the direction of the bisector of the incident and scattered light wave propagation vectors. Data were acquired for jet Mach numbers of 1.73 and 0.99 using a convergent 1.27-cm diameter round nozzle fitted with a single triangular "delta-tab". The velocity components and the streamwise vorticity calculated from the measurements are presented. The results demonstrate the ability of this novel optical system to obtain velocity and vorticity data without any artificial seeding and using a low power laser system.

Fagan, Amy↗

Large-Scale and Global Hydrology

Powered by the sun, water moves continuously between and through Earths oceanic, atmospheric, and terrestrial reservoirs. It enables life, shapes Earths surface, and responds to and influences climate change. Scientists measure various features of the water cycle using a combination of ground, airborne, and space-based observations, and seek to characterize it at multiple scales with the aid of numerical models. Over time our understanding of the water cycle and ability to quantify it have improved, owing to advances in observational capabilities, the extension of the data record, and increases in computing power and storage. Here we present some of the most recent estimates of global and continental ocean basin scale water cycle stocks and fluxes and provide examples of modern numerical modeling systems and reanalyses.Further, we discuss prospects for predicting water cycle variability at seasonal and longer scales, which is complicated by a changing climate and direct human impacts related to water management and agriculture. Changes to the water cycle will be among the most obvious and important facets of climate change, thus it is crucial that we continue to invest in our ability to monitor it.

land hydrology↗

An Approximate Method for Calculation of the Laminar Boundary Layer with Suction for Bodies of Arbitrary Shape

Various ways were tried recently to decrease the friction drag of a body in a flow; they all employ influencing the boundary layer. One of them consists in keeping the boundary layer Laminar by suction; promising tests have been carried out. Since for large Reynolds numbers the friction drag of the laminar boundary layer is much lower than that of the turbulent boundary layer, a considerable saving in drag results from keeping the boundary layer laminar, even with the blower power required for suction taken into account. The boundary layer is kept laminar by suction in two ways: first, by reduction of the thickness of the boundary layer and second, by the fact that the suction changes the form of the velocity distribution so that it becomes more stable, in a manner similar to the change by a pressure drop. There by the critical Reynolds number of the boundary layer (USigma*/V) (sub crit) becomes considerably higher than for the case without suction. This latter circumstance takes full effect only if continuous suction is applied which one might visualize realized through a porous wall. Thus the suction quantities required for keeping the boundary layer laminar become so small that the suction must be regarded as a very promising auxiliary means for drag reduction.

Schlichting, H.↗

SOFE2023 Presentation: "Tritium Safety and Sensitivity Analysis of Tritium Extraction eXperiment (TEX) PbLi Loop Using MELCOR-TMAP"

The efficient extraction of tritium from the breeder blanket (BB) in a fusion reactor is vital for maintaining the tritium economy for a sustainable and self-sufficient fusion power plant. The vacuum permeator (VP) design is one of several promising technology platforms for extracting tritium from the BB with the advantages of being capable of operating continuously at high temperatures with the aim of achieving high tritium extraction efficiencies. The Tritium Extraction eXperiment (TEX), under construction at the Safety and Tritium Applied Research (STAR) Facility at Idaho National Laboratory (INL), is designed to test the viability of VP technology by introducing atomic hydrogen (H, D, and T) from a source permeator (SP) into a forced convection lead lithium eutectic (PbLi) loop and determining the hydrogen extraction rates from the vanadium VP. Presented here is a computational analysis of the hydrogen inventory and permeation behavior in TEX using the hydrogen transport and accident analysis code MELCOR-TMAP developed at INL. The results of a sensitivity analysis based on MELCOR-TMAP simulations of hydrogen extraction efficiencies from the TEX test section using varying PbLi flow rates, hydrogen source rates from the SP, and material property uncertainties are also reported. Operation scenarios for TEX in consideration of the analyses based on results from MELCOR-TMAP are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development Status of the Carbon Dioxide and Moisture Removal Amine Swing-Bed System (CAMRAS)

Under a cooperative agreement with NASA, Hamilton Sundstrand has successfully designed, fabricated, tested and delivered three, state-of-the-art, solid amine prototype systems capable of continuous CO2 and humidity removal from a closed, habitable atmosphere. Two prototype systems (CAMRAS #1 and #2) incorporated a linear spool valve design for process flow control through the sorbent beds, with the third system (CAMRAS #3) employing a rotary valve assembly that improves system fluid interfaces and regeneration capabilities. The operational performance of CAMRAS #1 and #2 has been validated in a relevant environment, through both simulated human metabolic loads in a closed chamber and through human subject testing in a closed environment. Performance testing at Hamilton Sundstrand on CAMRAS #3, which incorporates a new valve and modified canister design, showed similar CO2 and humidity removal performance as CAMRAS #1 and #2, demonstrating that the system form can be modified within certain bounds with little to no effect in system function or performance. Demonstration of solid amine based CO2 and humidity control is an important milestone in developing this technology for human spaceflight. The systems have low power requirements; with power for air flow and periodic valve actuation and indication the sole requirements. Each system occupies the same space as roughly four shuttle non-regenerative LiOH canisters, but have essentially indefinite CO2 removal endurance provided a regeneration pathway is available. Using the solid amine based systems to control cabin humidity also eliminates the latent heat burden on cabin thermal control systems and the need for gas/liquid phase separation in a low gravity environment, resulting in additional simplification of vehicle environmental control and life support system process requirements.

Papale, William↗

Scientific Highlights and Status of the Mars Science Laboratory Mission, Years 9 through 12

We present the scientific highlights and status from years 9-12 of NASA’s Mars Science Laboratory mission, with its Curiosity rover. A thermochemolysis-based sample analysis revealed a variety of organic molecules preserved in clay mineral-rich lake/lake margin deposits of the Glen Torridon region. The stratigraphically higher clay-sulfate mineral transition on Aeolis Mons was found to be associated with a lithological change from lacustrine to dry aeolian depositional environments. Water intermittently returned to the surface after the increase in aridity, including during the deposition of wave ripple strata which indicate a climate capable of sustaining an ice-free lake in the early Hesperian. The overlying Mg sulfate-bearing unit has both poly- and monohydrated Mg sulfates and is also enriched in iron carbonate of a purity consistent with chemical sedimentation and therefore atmospheric sequestration. A channel-incised canyon within Gediz Vallis and distal alluvial deposits recorded numerous fluvial and debris flow events after the deposition, lithification, and erosion of the clay- and sulfate-bearing units. Bright clasts found in Gediz Vallis canyon are composed of native sulfur. The investigation of the modern atmosphere and environment focused on the influence of the crater and mountain topography and captured high-altitude noctilucent and iridescent clouds. Radiation monitoring now spans an 11-year solar cycle. Rover systems and science instruments remain capable of addressing mission scientific objectives. All ten scientific instruments continue to return high-value data despite degradation of the Chemistry and Camera instrument’s high-voltage system, loss of multispectral imaging capability, and loss of active neutron spectroscopy. The mission has mitigated the loss of redundant brakes on two arm joints, additional wheel wear, and highly reduced capability of the redundant flight computer. Efficiency improvements in rover energy utilization and operations staffing have allowed the mission team to maintain a high level of productivity despite declining rover power generation and funding.

Mars↗

Pulsed power to control growth of silicon nanoparticles in low temperature flowing plasmas

Low-temperature plasmas have seen increasing use for synthesizing high-quality, mono-disperse nanoparticles (NPs). Recent work has highlighted that an important process in NP growth in plasmas is particle trapping—small, negatively charged nanoparticles become trapped by the positive electrostatic potential in the plasma, even if only momentarily charged. In this article, results are discussed from a computational investigation into how pulsing the power applied to an inductively coupled plasma (ICP) reactor may be used for controlling the size of NPs synthesized in the plasma. The model system is an ICP at 1 Torr to grow silicon NPs from an Ar/SiH 4 gas mixture. This system was simulated using a two-dimensional plasma hydrodynamics model coupled to a three-dimensional kinetic NP growth and trajectory tracking model. The effects of pulse frequency and pulse duty cycle are discussed. We identified separate regimes of pulsing where particles become trapped for one pulsed cycle, a few cycles, and many cycles—each having noticeable effects on particle size distributions. For the same average power, pulsing can produce a stronger trapping potential for particles when compared to continuous wave power, potentially increasing particle mono-dispersity. Pulsing may also offer a larger degree of control over particle size for the same average power. Experimental confirmation of predicted trends is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗

Environmental Flow Requirements from FERC Licenses Across the US

Environmental flow requirements included in Federal Energy Regulatory Commission (FERC) hydropower licenses are important for balancing natural properties and benefits of river ecosystems (e.g., healthy species, recreation, water supply, flood control) supporting hydropower production. In some cases, environmental flow requirements may limit operational flexibility given current operational schemes and make a hydropower plant less able to provide power to the electric grid on demand. Hydropower plants may gain some flexibility as hydropower scheduling time periods are made to be more responsive to the short-term needs of an energy grid increasingly reliant on intermittent renewables. However, many flow requirements focus on the daily, monthly, or seasonal flow fluctuations which matches the time scale of most paradigms linking flow alterations to the health of river ecosystems. This dataset seeks to provide a greater understanding of how flexibility in environmental requirements can be leveraged to create positive outcomes for both the power system and the environment. It contains information on environmental flow requirements from the Protection, Mitigation, and Enhancement section of 50 randomly selected FERC licenses: 25 issued from 1998-2013 that were also included in the ORNL Mitigation Database (Schramm et al. 2015) and 25 issued from 2014-present. The information on environmental flow requirements was extracted from the PM&E section of 50 randomly selected FERC licenses: 25 issued from 1998-2013 that were also included in the ORNL Mitigation Database (Schramm et al. 2015) and 25 issued from 2014-present. The flow requirements were then categorized into flow augmentation categories based on whether the license stated a specific water management purpose for the given requirement called augmentation categories (i.e., fisheries or habitat, recreation or boating, industry, and general or unspecified; Table B). Requirements were also grouped into flow type categories (e.g., minimum flow rate, maximum flow rate, ramping rate). Additional information related to flow requirements such as the augmentation time-period and whether the flow rate was continuous (i.e., condition must be present at all-times) or instantaneous (i.e., condition present at a point in time) was also extracted from the licenses. Some licenses had specific flow requirements based on whether the project was in a wet, dry, or normal water year. If that information was presented in the license, it was also included in the data set. The location within the project was noted, hereafter, zone, in the dataset for flow requirements relating to specific areas of hydropower projects (Dam, Powerhouse, Bypass Reach). Maximum discharge capacities of hydropower facilities were also extracted from both the Existing Hydropower Assets (EHA) data set and the National Inventory of Dams (NID) databases. Each facility was coded with project identification codes from the EHA dataset to facilitate cross-referencing between datasets.

13 HYDRO ENERGY↗

Nonlinear Electrostatic Properties of Lunar Dust

A laboratory experiment was designed to study the induction charging and charge decay characteristics of small dielectric particles, or glass beads. Initially, the goal of the experiment was further understanding of induction charging of lunar dust particles. However, the mechanism of charging became a point of greater interest as the project continued. Within an environmentally-controlled acrylic glove box was placed a large parallel plate capacitor at high-voltage (HV) power supply with reversible polarity. Spherical 1-mm and 0.5-mm glass beads, singly, were placed between the plates, and their behaviors recorded on video and quantified. Nearly a hundred trials at various humidities were performed. The analysis of the results indicated a non-linear relationship between humidity and particle charge exchange time (CET), for both sizes of beads. Further, a difference in CET for top-resting beads and bottom-resting beads hinted at a different charging mechanism than that of simple induction. Results from the I-mm bead trials were presented at several space science and physics conferences in 2008 and 2009, and were published as a Master's thesis in August 2009. Tangential work stemming from this project resulted in presentations at other international conferences in 2010, and selection to attend workshop on granular matter flow 2011.

Irwin, Stacy A.↗

High Performance Heat Pipe Power Transient Testing at SPHERE Facility

Microreactors are being researched, designed, and built at Idaho National Laboratory (INL). Microreactors are small reactors defined at less than 20MW of power. These reactor concepts are also being looked at throughout industry for various applications. An important aspect of these reactor designs is economic feasibility i.e. lower overnight capital cost. The driving factors for implementing microreactors are quick setup and takedown, minimal operators, and the ability to manufacture them readily and to fit in mid-sized containers for transport. A specific area of research to aid in successful integration of these factors within the designs is passive heat removal of the core’s thermal power. Interest in heat pipes to achieve this passive heat removal has been shown across multiple industry partners. Because of this interest, INL has developed a test facility to facilitate experimental tests for sodium filled heat pipes. INL has developed the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility to run experiments on high performance, sodium filled heat pipes. As mentioned above, heat pipes are passive heat transfer devices. Radially, heat pipes are broken up into an outer wall, a small annular gap, a wick structure, and a centerline gap. They function by utilizing latent heat transfer. Heat pipes are traditionally separated into three regions, an evaporator (heat input), an adiabatic region, and finally a condenser region (heat removal). As heat is being applied to the evaporator, the working fluid undergoes a phase change to a vapor. This phase change causes a differential pressure across the axial length of the pipe driving flow down the center gap of the heat pipe. The vapor flows down past the adiabatic region to the condenser where the heat is removed. This heat removal forces the working fluid to phase change back to a liquid. The wick structure is then utilized to drive the flow back towards the evaporator by capillary forces. This backflow is aided by the annular gap. Because this heat transfer mechanism functions with latent heat transfer, the heat pipe is close to isothermal down the axial length. Heat pipes can operate under a wide range of working fluids. Considerations for these working fluids are primarily driven by operating temperatures amongst other important factors based around overall performance. Sodium filled heat pipes operate from 450°C up to 900°C. This temperature range works well for the current microreactor designs. In conjunction with this experimental capability, INL has developed a modeling software to simulate heat pipe physics within reactor cores. This modeling software is called Sockeye and functions under the established INL Multiphysics Object Oriented Simulation Environment (MOOSE). SPHERE also supports Sockeye development by providing the modeling team with experimental data on an array of setups and operating parameters to support validation efforts. A power transient experiment was performed utilizing the SPHERE facility to continue to aid with Sockeye development. The testing followed a proposed test plan to ramp up and down the temperature of the heat pipe. Sockeye models steady state heat pipe operation with high accuracy, the data provided by the power transient testing aims to assist with the validation efforts and further enhance transient modeling capability of the tool [2].

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Novel concept for detection of a fluid flow fault in a pumped fluid heat rejection system

A pumped fluid heat rejection system (HRS) requires continuous flow of the working fluid to ensure that the components controlled by the HRS stay within their allowable temperature limits. An interruption of flow could result in violations of hardware qualification limits and mission failure. Some of these violations can happen within a few hours. Hence, quick detection of a flow fault to invoke mitigation measures is very critical. In typical pumped fluid HRS, dual or triple pumps are employed to switch the backup units in case the primary unit were to fail. The key metric for the selection of a fault detection system is that it should detect the fault much before the fault’s impact on the thermal health of the HRS controlled components is realized. A trade study was conducted to select such a system for the Europa Clipper Mission to Europa, a moon of Jupiter that is planned for a launch in 2023. Out of the several concepts studied, the most attractive one was a novel and simple concept that uses a low power film heater attached to a section of the HRS tubing. While the fluid flows at its nominal rate, the high thermal coupling of the flowing fluid leads to the tube being close to the fluid’s temperature. However, when the flow stops, the heater warms the small thermal mass of the tubing to a high temperature in a short span of time (~15 minutes). This large temperature rise would then imply that the flow must have stopped. This paper will describe the various concepts considered, the chosen concept, its implementation, and the results of developments tests to validate its performance.

Schmidt, Tyler↗

Leveraging Optimal Sparse Sensor Placement to Aggregate a Network of Digital Twins for Nuclear Subsystems

Nuclear power plants (NPPs) require continuous monitoring of various systems, structures, and components to ensure safe and efficient operations. The critical safety testing of new fuel compositions and the analysis of the effects of power transients on core temperatures can be achieved through modeling and simulations. They capture the dynamics of the physical phenomenon associated with failure modes and facilitate the creation of digital twins (DTs). Accurate reconstruction of fields of interest (e.g., temperature, pressure, velocity) from sensor measurements is crucial to establish a two-way communication between physical experiments and models. Sensor placement is highly constrained in most nuclear subsystems due to challenging operating conditions and inherent spatial limitations. This study develops optimized data-driven sensor placements for full-field reconstruction within reactor and steam generator subsystems of NPPs. Optimized constrained sensors reconstruct field of interest within a tri-structural isotropic (TRISO) fuel irradiation experiment, a lumped parameter model of a nuclear fuel test rod and a steam generator. The optimization procedure leverages reduced-order models of flow physics to provide a highly accurate full-field reconstruction of responses of interest, noise-induced uncertainty quantification and physically feasible sensor locations. Accurate sensor-based reconstructions establish a foundation for the digital twinning of subsystems, culminating in a comprehensive DT aggregate of an NPP.

42 ENGINEERING↗

General relativistic MHD simulations of non-thermal flaring in Sagittarius A*

Sgr A* exhibits regular variability in its multiwavelength emission, including daily X-ray flares and roughly continuous near-infrared (NIR) flickering. The origin of this variability is still ambiguous since both inverse Compton and synchrotron emission are possible radiative mechanisms. The underlying particle distributions are also not well constrained, particularly the non-thermal contribution. In this work, we employ the GPU-accelerated general relativistic magnetohydrodynamics code H-AMR to perform a study of flare flux distributions, including the effect of particle acceleration for the first time in high-resolution 3D simulations of Sgr A*. For the particle acceleration, we use the general relativistic ray-tracing code bhoss to perform the radiative transfer, assuming a hybrid thermal+non-thermal electron energy distribution. We extract ~60 h light curves in the sub-millimetre, NIR and X-ray wavebands, and compare the power spectra and the cumulative flux distributions of the light curves to statistical descriptions for Sgr A* flares. Our results indicate that non-thermal populations of electrons arising from turbulence-driven reconnection in weakly magnetized accretion flows lead to moderate NIR and X-ray flares and reasonably describe the X-ray flux distribution while fulfilling multiwavelength flux constraints. These models exhibit high rms per cent amplitudes, $\gtrsim 150{{\ \rm per\ cent}}$ both in the NIR and the X-rays, with changes in the accretion rate driving the 230 GHz flux variability, in agreement with Sgr A* observations.

79 ASTRONOMY AND ASTROPHYSICS↗

In Situ Wind and Turbulence Measurements in a Field of Full-Size Parabolic Trough Solar Collectors

Concentrated Solar Power (CSP) is a promising method for using Solar power for electricity generation with thermal energy storage. One of the primary drivers of structural design costs of CSP collector structures is wind loading. To date, the design of these structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights on structural dynamic response, and generating a first-of-a-kind, comprehensive, high-resolution wind-loading dataset available for validating simulations of wind loading on collector structures. The measurements at NSO consist of Sonic anemometers on masts at different heights to characterize the incoming flow and conditions within and above the trough field, in combination with a Doppler Lidar scanning the horizontal plane above the troughs. The wind measurements at NSO have been continuously operating since October 2021 and provide a year-long dataset characterizing wind and turbulence conditions. The structural load measurements start in November 2022 and will complement the wind measurements. In this poster, we present first results of the wind measurement campaign by highlighting days with different atmospheric flow conditions. We identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. The highest loads are expected when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest loads and block the subsequent rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales change. These affected conditions produce unique load cases on the structures that will be captured by the load measurements. If the wind blows along the trough rows, wind and turbulence conditions are less influenced by the troughs.

atmospheric turbulence↗

Self-similar Reynolds-averaged mechanical–scalar turbulence models for reshocked Richtmyer–Meshkov instability-induced mixing in the small Atwood number limit

Analytical self-similar solutions to two-, three-, and four-equation Reynolds-averaged mechanical–scalar turbulence models describing incompressible turbulent Richtmyer–Meshkov instability-induced mixing in planar geometry derived in the small Atwood number limit are extended to construct models for reshocked Richtmyer–Meshkov mixing. In this study, the models are based on the turbulent kinetic energy K and its dissipation rate ε, together with the scalar variance S and its dissipation rate χ modeled either differentially or algebraically. The three- and four-equation models allow for a simultaneous description of mechanical and scalar mixing, i.e., mixing layer growth and molecular mixing. Mixing layer growth parameters and other physical observables were obtained explicitly as functions of the model coefficients and were used to calibrate the model coefficients. Here, the solutions for the singly shocked Richtmyer–Meshkov case for the mixing layer width and the turbulent fields are used to construct piecewise-continuous generalizations of these quantities for times after reshock. For generality, the post-reshock mixing layer width is not assumed to grow with the same power-law as the pre-reshock width, and an impulsive approximation applied to Rayleigh–Taylor instability growth is used to establish the expression for the post-reshock width. A four-equation model is then used to illustrate the spatiotemporal behavior of the mean and turbulent fields and late-time turbulent equation budgets across the mixing layer. The reference solutions derived here can provide systematic calibrations and better understanding of mechanical–scalar turbulence models and their predictions for reshocked Richtmyer–Meshkov instability-induced turbulent mixing in the very large Reynolds number limit.

42 ENGINEERING↗

Oscillatory/Chaotic Thermocapillary Flow Induced by Radiant Heating

There is a continuing need to understand the fluid physics occurring under low gravity conditions in processes such as crystal growth, materials processing, and the movement of bubbles or droplets. The fluid flow in such situations is often caused by a gradient in interfacial tension. If a temperature gradient is created due to a heat source, the resulting flow is called thermocapillary flow, a special case of Marangoni Convection. In this study, an experimental investigation was conducted using silicone oil in cylindrical containers with a laser heat source at the free surface. It was desired to determine the conditions under which steady, axisymmetrical thermocapillary flow becomes unstable and oscillatory three-dimensional flow states develop. The critical Marangoni number for each observed oscillatory state was measured as a function of the container aspect ratio and the dynamic Bond number, a measure of buoyant force versus ii thermocapillary force. Various oscillatory modes were observed during three- dimensional convection, and chaotic flow was reached in one test condition. The critical Marangoni numbers are compared with those measured in previous studies, and the power spectra and phase trajectories of the instantaneous surface temperature distributions are used to characterize the routes of transitions to the chaotic flow state. Results show that only superharmonic modes appear in the routes to chaos while infinite number of subharmonic modes occur in flow transitions for pure Rayleigh convection.

DeWitt, Kenneth J.↗

Multiwavelength Light Curves of Two Remarkable Sagittarius A* Flares

Sgr A* , the supermassive black hole (SMBH) at the center of our Milky Way Galaxy, is known to be a variable source of X-ray, near-infrared (NIR), and submillimeter radiation and therefore a prime candidate to study the electromagnetic radiation generated by mass accretion flow onto a black hole and/or a related jet. Disentangling the power source and emission mechanisms of this variability is a central challenge to our understanding of accretion flows around SMBHs. Simultaneous multiwavelength observations of the flux variations and their time correlations can play an important role in obtaining a better understanding of possible emission mechanisms and their origin. This paper presents observations of two flares that both apparently violate the previously established patterns in the relative timing of submillimeter/NIR/X-ray flares from Sgr A* . One of these events provides the first evidence of coeval structure between NIR and submillimeter flux increases, while the second event is the first example of the sequence of submillimeter/X-ray/NIR flux increases all occurring within ∼1 hr. Each of these two events appears to upend assumptions that have been the basis of some analytic models of flaring in Sgr A* . However, it cannot be ruled out that these events, even though unusual, were just coincidental. These observations demonstrate that we do not fully understand the origin of the multiwavelength variability of Sgr A* and show that there is a continued and important need for long-term, coordinated, and precise multiwavelength observations of Sgr A* to characterize the full range of variability behavior

accretion↗