The ultrafast Kerr effect in anisotropic and dispersive media

The ultrafast optical Kerr effect (OKE) is widely used to investigate the structural dynamics and interactions of liquids, solutions, and solids by observing their intrinsic nonlinear temporal responses through nearly collinear four-wave mixing. Non-degenerate mixing schemes allow for background free detection and can provide information on the interplay between a material’s internal degrees of freedom. Here, we show a source of temporal dynamics in the OKE signal that is not reflective of the internal degrees of freedom but arises from a group index and momentum mismatch. It is observed in two-color experiments on condensed media with sizable spectral dispersion, a common property near an optical resonance. In particular, birefringence in crystalline solids is able to entirely change the character of the OKE signal via the off-diagonal tensor elements of the nonlinear susceptibility. We develop a detailed description of the phase-mismatched ultrafast OKE and show how to extract quantitative information on the spectrally resolved birefringence and group index from time-resolved experiments in one and two dimensions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Seismic Characterization of the Blue Mountain Geothermal Field

Subsurface characterization is crucial for geothermal energy exploration and production. Yet hydrothermal reservoirs usually reside in highly fractured and faulted zones where accurate characterization is very challenging because of low signal-to-noise ratios of land seismic data and lack of coherent reflection signals. We perform an active-source seismic characterization for the Blue Mountain geothermal field in Nevada using active seismic data to reveal the elastic medium property complexity and fault distribution at this field. We first employ an unsupervised machine learning method to attenuate groundroll and near-surface guided-wave noise and enhance coherent reflection and scattering signals from noisy seismic data. We then build a smooth initial P-wave velocity model based on an existing magnetotellurics survey result, and use 3D first-arrival traveltime tomography to refine the initial velocity model. We then derive a set of elastic wave velocities and anisotropic parameters using elastic full-waveform inversion, and obtain PP and PS images using elastic reverse-time migration. We identify major faults by analyzing the variations of seismic velocities and anisotropy parameters, and reveal mid- to small-scale faults by applying a supervised machine learning method to the seismic migration images. Our characterization reveals complex velocity heterogeneities and anisotropies, as well as faults, with a high spatial resolution. These results can provide valuable information for optimal placement of future injection and production wells to increase geothermal energy production at the Blue Mountain geothermal power plant.

58 GEOSCIENCES↗

Thin-film lithium niobate on diamond as a platform for efficient spin-phonon coupling

Negatively charged silicon vacancy (SiV − ) centers in diamond are leading candidates for solid-state quantum memory that can be controlled using electromagnetic or acoustic waves. The latter are particularly promising due to the strong strain response of SiV − , enabling large spin-phonon interaction strengths. Indeed, coherent spin control via surface acoustic waves (SAWs) has been demonstrated and is essential for developing on-chip phononic quantum networks. However, the absence of piezoelectricity in diamond requires an interface with a piezoelectric material for efficient transduction and delivery of acoustic waves to spins in diamonds. Here, we demonstrate a heterogeneously integrated phononic platform that combines thin-film lithium niobate with diamond to enable acoustic control of single SiV − spins. Additionally, leveraging large SAW-induced strain at the location of SiV − , we achieve coherent acoustic control of an electron spin with more than twofold improvement in Rabi frequency compared to state-of-the-art devices based on aluminum nitride on diamond. Furthermore, this work represents a crucial step towards realizing phonon-based quantum information processing systems.

Optically detected magnetic resonance↗

Phase Demodulation by Frequency Chirping in Coherence Microwave Photonic Interferometry

This paper presents a signal processing method to demodulate the optical interference phase of cascaded individual optical fiber intrinsic Fabry-Perot interferometric (IFPI) sensors in a coherent microwave-photonic interferometry (CMPI) distributed sensing system. The new method utilizes the chirp effect of electro-optic modulator (EOM) to create a quasi-quadrature optical interference phase shift between two adjacent pulses which correspond to two adjacent reflection points in the time domain. The phase shift can be controlled by adjusting the bias voltage that is applied to the EOM. The interference phase is calculated by elliptically fitting the phase shift. The interference phase change is proportional to the optical path difference (OPD) change of the interferometer, and the sign can be used to differentiate the increase or decrease of the OPD. The method is demonstrated for distributed strain sensing, showing good linearity, high resolution and large dynamic range.

42 ENGINEERING↗

Superconductivity and phase diagrams of CaK(Fe 1- x Mn x ) 4 As 4 single crystals

In order to study the effects of Mn substitution on the superconducting and magnetic ground state of CaKFe 4 As 4 (T c = 35 K), members of the CaK (Fe 1–x Mn x ) 4 As 4 series have been synthesized by high-temperature solution growth in single-crystalline form and characterized by elemental analysis, thermodynamic, and transport measurements. These measurements show that the superconducting transition temperature decreases monotonically and is finally suppressed below 1.8 K as x is increased from 0 to 0.036. For x values greater than 0.016, signatures of a magnetic transition can be detected in both thermodynamic and transport measurements in which kinklike features allow for the determination of the transition temperature T* that increases as Mn substitution increases. Here, a temperature-composition (T–x) phase diagram is constructed, revealing a half-dome of superconductivity with the magnetic transition temperature T* appearing near 26 K for x ~ 0.017 and rising slowly up to 33 K for x ~ 0.036. In addition to the creation of the T–x phase diagram for CaK(Fe 1–x Mn x ) 4 As 4 , specific-heat data are used to track the jump in specific heat at T c ; the CaK(Fe 1–x Mn x ) 4 As 4 data do not follow the scaling of ΔC p with $T$$^{3}_{c}$ as many of the other Fe-based superconducting systems do. These data suggest that, as magnetic pair breaking is present, the jump in C p for a given T c is reduced. Elastoresistivity coefficients 2m 66 and m 11 – m 12 as a function of temperature are also measured. 2m 66 and m 11 – m 12 are qualitatively similar to CaK(Fe 1–x Ni x ) 4 As 4 . This may indicate that the magnetic order in Mn-substituted system may be still the same as CaK(Fe 1–x Mn x ) 4 As 4 . Superconductivity of CaK(Fe 1–x Mn x ) 4 As 4 is also studied as a function of magnetic field. A clear change in H' c2 (T)/T c , where H' c2 (T) is dH' c2 (T)/dT, at x ~ 0.015 is observed and probably is related to change of the Fermi surface due to magnetic order. Coherence lengths and the London penetration depths are also calculated based on H c1 and H c2 data. Coherence lengths as the function of x also show the changes near x = 0.015, again consistent with Fermi-surface changes associated with the magnetic ordering seen for higher-x values.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Complete spectroscopy in the attosecond regime

Harnessing light waveforms at attosecond time scales provides information of the structure and dynamics of matter on it's natural time scales. For this reason attosecond metrology has been at the forefront of the optical sciences for more than a decade, and it represents the latest time-domain frontier of the quantum world. Attosecond light pulses are commonly generated using higher-order harmonic generation (HHG) , a process capable of generating XUV coherent pulses. In addition to generate attosecond pulses, HHG can be used to study the structure and dynamics of atoms and molecules by analyzing the spectral content of the XUV pulses. This approach is known as HHG spectroscopy and it provides a coherent, time-dependent approach to study structure and dynamics in the quantum world. In this proposal we will generate harmonics from two optical foci produced by a system of a two-dimensional spatial light modulator (SLM) and a lens. In the far eld the train of attosecond pulses will interfere creating harmonic-dependent fringes. The position of such fringes is a direct measurement of the relative phase between the two foci and they also carry information about the quantum state of the target atom or molecule. Therefore, by measuring the amplitude and relative phase of the emitted harmonics we will have access to both, the amplitude and phase of the dipole moments of the studied target. Because the two beams are completely indistinguishable from each other up to a few millimeters from the focus, both driving pulses share the exact beam path. So far we have measured a jitter of 700 zeptoseconds with a 12.5 attosecond resolution in the delay control of the two foci. These two time scales represent some of the best time controls ever achieved to date.

74 ATOMIC AND MOLECULAR PHYSICS↗

Long-baseline quantum sensor network as dark matter haloscope

Ultralight dark photons constitute a well-motivated candidate for dark matter. A coherent electromagnetic wave is expected to be induced by dark photons when coupled with Standard-Model photons through kinetic mixing mechanism, and should be spatially correlated within the de Broglie wavelength of dark photons. Here we report the first search for correlated dark-photon signals using a long-baseline network of 15 atomic magnetometers, which are situated in two separated meter-scale shield rooms with a distance of about 1700 km. Both the network’s multiple sensors and the shields large size significantly enhance the expected dark-photon electromagnetic signals, and long-baseline measurements confidently reduce many local noise sources. Using this network, we constrain the kinetic mixing coefficient of dark photon dark matter over the mass range 4.1 feV-2.1 peV, which represents the most stringent constraints derived from any terrestrial experiments operating over the aforementioned mass range. Our prospect indicates that future data releases may go beyond the astrophysical constraints from the cosmic microwave background and the plasma heating.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

High-efficiency, high-fidelity charge initialization of shallow nitrogen-vacancy centers in diamond

Nitrogen-vacancy (N-𝑉) centers in diamond exhibit long spin-coherence times, optical initialization, and optical-spin readout under ambient conditions, making them excellent quantum sensors. However, the conventional scheme for charge-state initialization based on off-resonant green excitation results in significant state-preparation errors, typically around 30%. One method for improving charge-state initialization fidelity is to use multicolor excitation, which has been demonstrated to achieve a near-unity preparation fidelity for bulk N-𝑉 centers by using a few milliseconds of near-infrared (NIR) (5-mW) and green (10-μ⁢W) excitation. The translation of such schemes to N-𝑉 centers near the diamond surface with higher-efficiency optical pumping would enable new applications in nanoscale sensing. Here, we demonstrate a protocol for efficient charge initialization of shallow N-𝑉 centers between 5 nm and 15 nm from the diamond surface. By carefully studying the charge dynamics of shallow N-𝑉 centers, we identify a region of parameter space that allows for near-unity (95%) charge initialization within 300 μ⁢s of NIR (905-nm, 1-mW) and green (520-nm, 10-μ⁢W) excitation. The time to 90% charge initialization can be as fast as 10 μ⁢s for 4 mW of NIR and 39 μ⁢W of green illumination. This fast, efficient charge initialization protocol will especially benefit nanoscale sensing applications in which state-preparation errors currently prohibit scaling, such as measuring higher-order multipoint correlators.

infrared techniques↗

Measurement of Electron-Neutrino Charged-Current Cross Sections on 127 I with the COHERENT NaI$ν$E Detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino chargedcurrent cross section on 127 I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of ${9.2}_{–1.8}^{+2.1}$ × 10 –40 cm 2 . This corresponds to a value that is ~41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on 127 I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be ${5.2}_{–3.1}^{+3.4}$ × 10 –40 and ${2.2}_{—2.2}^{+3.5}$ × 10 –40 cm 2 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning of the Mu2e tracker DAQ, planning for the Vertical Slice Test and pre-pattern recognition studies

The primary objective of the Mu2e experiment at Fermilab is to search for the neutrino-less coherent $\mu \rightarrow e$ conversion in the field of an aluminum nucleus ($\mu^- \text{Al} \rightarrow e^- \text{Al}$). The signature of this process is a monochromatic Conversion Electron (CE) with an energy of approximately 104.97 MeV \cite{bartoszek2015mu2e}. Within the Standard Model (SM), the branching ratio for this process, including neutrino masses and oscillation, is expected to be less than $\mathcal{O}(10^{-50})$. This value is far beyond current experimental capabilities. However, models of physics beyond the SM predict much higher relative rates, approaching an observable level. The SINDRUM II experiment set an upper limit on muon conversion at $7 \times 10^{-13}$ (90\% CL) on Au target \cite{SINDRUMII:2006dvw}, and the Mu2e collaboration aims to improve this limit by four orders of magnitude. Observing this process would provide a clear evidence of physics beyond the Standard Model. A brief discussion of the theoretical and experimental aspects is provided in Chapter \ref{intr}. Mu2e adopts a sophisticated experimental setup to achieve its goals, further described in Chapter \ref{mu2echapter}. The central part of the Mu2e detector is the tracker, that consists of 18 tracking stations. The tracker must provide excellent momentum resolution, approximately 1 MeV/c, to distinguish the monochromatic CE signal from the background. To minimize the energy losses, a straw tube tracker will be used \cite{bobbb}. Chapter \ref{chaptertrk} provides an overview of the straw tracker design and its working principles. This Thesis presents a comprehensive study of the Mu2e tracker, covering complementary aspects from initial commissioning to optimization and first steps of the calibration processes. My work at Fermilab has been focused on the complete Data Acquisition (DAQ) testing from both hardware and software perspectives. I was involved in the commissioning of the Mu2e DAQ system and the Vertical Slice Test (VST) of the tracker. The VST encompasses the entire testing chain, from the straws to the readout, and to processed data on disk. I was also focused on the offline analysis, especially on pre-pattern recognition studies, to explore the best methods for identifying $\delta$-electrons during the data taking. Chapter \ref{commissioning} details the commissioning of the tracker DAQ system, emphasizing the importance of understanding of the readout process before the data acquisition. This includes validating the readout logic and firmware through Monte Carlo simulations to confirm functionality and buffering, monitoring the quality of the data from the tracker preamplifiers and front-end electronics, and assessing overall DAQ performance to ensure reliability during future calibration and data-taking. Chapter \ref{planning} discusses the initial steps towards the tracker calibration. The ultimate goal is to perform a time calibration of the first assembled station of the tracker using cosmic muons, aiming for a longitudinal hit position resolution better than 4 cm. This involves determining the signal propagation times and channel-to-channel delays. I performed a Monte Carlo study to determine the impact of the station orientation on the quality of the calibration, in particular on the cosmic track reconstruction, focusing on potential biases that could arise. These studies provide essential insights into the operation, optimization, and calibration of the Mu2e tracker system. Given the high data volume expected during Mu2e operations, estimated at approximately 7 PBytes per year, optimizing memory usage and minimizing CPU consumption are critical. A significant challenge lies in effectively flagging $\delta$-electron hits, which are the primary source of hits in the tracker, without compromising the efficiency of CE hit detection and track reconstruction. A detailed study of pre-pattern recognition and a thorough comparison of two $\delta$-electron flagging algorithms is provided in Chapter \ref{delta}. In Chapter \ref{conclusions}, the findings are concisely summarized, offering a comprehensive synthesis of the research and emphasizing the key insights derived from this study.

43 PARTICLE ACCELERATORS↗

The properties of the nitrogen-vacancy center in milled chemical vapor deposition nanodiamonds

Fluorescent nanodiamonds (FNDs) containing negatively charged nitrogen-vacancy (NV − ) centers are vital for many emerging quantum sensing applications from magnetometry to intracellular sensing in biology. However, developing a scalable fabrication method for FNDs hosting color centers with consistent bulk-like photoluminescence (PL) and spin coherence properties remains a highly desired but unrealized goal. Here, we investigate optimized ball milling of single-crystal diamonds produced via chemical vapor deposition (CVD) and containing 2 ppm of substitutional nitrogen and 0.3 ppm of NV − to achieve this goal. The NV charge state, PL lifetime, and spin properties of bulk CVD diamond samples are directly compared to milled CVD FNDs and commercial high-pressure high-temperature (HPHT) FNDs. We find that on average, the relative contribution of the NV − charge state to the total NV PL is lower and the NV PL lifetime is longer in CVD FNDs compared to HPHT FNDs, both likely due to the lower N s 0 concentration in CVD FNDs. The CVD bulk and CVD FNDs on average show similar average T 1 spin relaxation times of 3.2 ± 0.7 ms and 4.7 ± 1.6 ms, respectively, compared to 0.17 ± 0.01 ms for commercial HPHT FNDs. Our results demonstrate that ball milling of CVD diamonds enables the large-scale fabrication of NV ensembles in FNDs with bulk-like T 1 spin relaxation properties.

chemical vapor deposition↗

Robust In-Situ Strain Measurements to Monitor CO 2 Storage

The goal of this project was to develop and demonstrate robust instrumentation to monitor the in-situ strain tensor in order to improve the reliability and security of CO 2 storage in geologic formations. We met the original goals of the project and the major overarching accomplishment is the advancement of strain tensor monitoring from an intriguing concept to a commercially available technology with a solid foundation of novel instruments supported by theoretical analyses and validation experiments. The main accomplishments of the project are summarized below. We designed, built and evaluated nine new optical fiber strainmeters and tiltmeters using Michelson interferometers to measure deformation with ultra-high resolution at both shallow and deep point locations in the subsurface. These are the robust strainmeters that motivated the title of the project. We designed, built and evaluated a novel method of measuring distributed strain in optical fibers with nanostrain resolution, and cm-scale location, and sampling into the seismic band. The new method is called Coherence-length-gated Microwave Photonics Interfereometry (CMPI). CMPI technology has advantages over existing commercial DAS and DSS methods. We developed and demonstrated capabilities to deploy instruments in the field and used them to measure strain caused by ambient signals like barometric pressure and tides, as well as induced signals like surface loading and pore pressure changes from pumping tests. We deployed a working strainmeter at 1,700 ft depth, slightly above an active reservoir. This is to our knowledge the greatest depth a strainmeter has been deployed and the techniques we used can readily be extended to greater depths. Optical fiber borehole tensor strainmeter techology was advanced from a TRL 4 at the start, to a TRL of 7 at the conclusion of the project. The project included advances in simulations and theoretical analyses. We developed and demonstrated a computational workflow that uses machine learning to reduce the computational requirements and make it practical to use Bayesian inversion to solve large numerical poroelastic analyses needed to interpret strain tensor field data. We evaluated the strain tensor fields and time series that would be caused by leaks of CO 2 or other fluids from reservoirs. These simulations demonstrated that signals from leaks could be measured with instruments developed for the project, opening a potentially new method for ensuring storage security. We showed that strains in caprock can be used to estimate pressure in a reservoir. This avoids the need to drill monitoring wells into the reservoir, and it expands the capabilities of monitoring in the caprock. The project includes a derivation and application of a novel analytical solution to the strains in the vicinity of a pressurized poroelastic inclusion. This solution explains field data measured during injeciton tests at the North Avant Field, and it will simplify future interpretation of strain tensor data. The project included a broad range of experiments, and of the most significant is the characterization of the strain tensor at an array three strainmeters during six injection tests at the North Avant Field, Oklahoma. This demonstrated repeatability of the strain signal measured by the new instruments developed for the project, and it showed similarities between the strain signal at shallow depths and pressure in the underlying reservoir. We also demonstrated that useful strain data can be measured at reservoir depths. This confirms that strain tensor data can be measured throughout the caprock over a reservoir. The project demonstrated the feasibility of using the strain tensor and distributed strain measured in caprock during a variety of different well tests where the pumping rate was constant, sinusoidal and positive, or a periodic square wave with zero net rate. This further strengthens the validity of using strain data to characterize reservoirs and aquifers. We also demonstrated that strain caused be fluctuations of air pressure and water pressure in the vadose zone can be measured and interpreted, suggesting that high resolution distributed strain measurements hold promise for monitoring the vadose zone. The project partially supported nine graduate students in the Environmental Engineering, Hydrogeology, Electrical Engineering programs at Clemson University. The research was described in nine journal papers, 23 talks and conference abstracts. Additional journal papers are in preparation. A new company called Tensora was started to provide strainmeter technology for commercial applications.