Imaging, understanding, and control of nanoscale materials transformations

The development of liquid cells for transmission electron microscopy has enabled breakthroughs in our ability to follow nanoscale structural, morphological, or chemical changes during materials growth and applications. Time-resolved high-resolution imaging and chemical analysis through liquids opened the opportunity to capture nanoscale dynamic processes of materials, including reaction intermediates and the transformation pathways. In this article, a series of work is highlighted with topics ranging from liquid cell developments to in situ studies of nanocrystal growth and transformations, dendrite formation, and suppression of lithium dendrites through in situ characterization of the solid–electrolyte interphase chemistry. The understanding garnered is expected to accelerate the discovery of novel materials for applications in energy storage, catalysis, sensors, and other functional devices.

36 MATERIALS SCIENCE↗

Product Consistency Test Results for the High-Chromium Matrix Glasses

This report provides chemical analysis of a series of Product Consistency Test (PCT) leachates from simulated nuclear waste glasses. The resulting data will be used in the development of improved property/composition models. For some of the glass leachates, minor scatter among the triplicate values of some analytes was observed. For other leachates, there were more significant differences among the triplicate values. A review of the PCT data noted that there was little difference between the normalized values on the basis of targeted or measured glass composition. Several of the study glasses, both quenched and canister centerline cooled, have NC i values that are greater than the Hanford Tank Waste Treatment and Immobilization Plant immobilized low-activity waste constraint of 4 g/L for B, Na, and Si. For many of the study glasses, heat treatment had only a marginal impact on the NC i values. The samples of the Environmental Assessment (EA) reference glass included with each PCT set had inconsistent NC i values, although some degree of variation in NC i values for the EA glass is typical. The release rates for boron and sodium were highly correlated for the study glasses, while for the other analytes, less correlation was observed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Product Consistency Test Results for the LXC-Series Glasses

This report provides chemical analysis of a series of Product Consistency Test (PCT) leachates from simulated nuclear waste glasses. The resulting data will be used in the development of improved property/composition models. For some of the glass leachates, minor scatter among the triplicate values of some analytes was observed. For other leachates, there were more significant differences among the triplicate values. A review of the PCT data noted that there was little difference between the normalized values on the basis of targeted or measured glass composition. Several of the canister centerline cooled study glasses have NC i values that are greater than the Hanford Tank Waste Treatment and Immobilization Plant immobilized low-activity waste constraint of 4 g/L for B and Na. The results of these glasses will help ensure the ability of advanced glass performance models to appropriately predict acceptable compositions. For many of the study glasses, heat treatment had only a marginal impact on the NC i values. The samples of the Environmental Assessment (EA) reference glass included with each PCT set had generally consistent NC i values. The release rates for boron and sodium, and for sodium and silicon were highly correlated for the study glasses, while for the other analytes, less correlation was observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Product consistency test results for the LAW Phase 4 gases

In this report, the Savannah River National Laboratory provides chemical analysis of Product Consistency Test (PCT) leachates from a series of simulated nuclear waste glasses fabricated at the Pacific Northwest National Laboratory (PNNL). The series included quenched and canister-centerline cooled (CCC) versions of the glasses. The resulting data will be used in the development of enhanced property/composition models for waste vitrification at Hanford. For some of the glass leachates, minor scatter among the triplicate values of some analytes were observed. For other leachates, there were more significant differences among the triplicate values. A review of the PCT data noted that there was little difference between the normalized values based on targeted or measured glass composition. Several of the study glasses have normalized concentration of element “i” (NCi) values that are greater than the Hanford Tank Waste Treatment and Immobilization Plant immobilized low-activity waste constraint of 4 g/L for boron (B), sodium (Na), and silicon (Si). The results of these glasses will help ensure the ability of advanced glass performance models to appropriately predict acceptable compositions. For the study glasses with NCi values exceeding 4 g/L, the CCC heat treatment samples had generally lower NCi values than quenched samples. The samples of the Environmental Assessment (EA) reference glass included with each PCT set had generally consistent NCi values. The release rates for boron (B), potassium (K), lithium (Li), sodium (Na), and silicon (Si) were highly correlated for the study glasses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neural Density Estimation and Uncertainty Quantification for ChemCam Spectra [Slides]

The ChemCam instrument of Curiosity uses laser-induced breakdown spectroscopy (LIBS). It fires a laser at target and vaporizes rock surfaces, creating a plasma. Three spectrographs divide the plasma light into wavelengths for chemical analysis: ultraviolet, violet, and visible near-infrared. Regression methods (SVR, PCR, CNN) have been employed for calibration (prediction of the elemental composition of samples); however, labeled ChemCam samples are limited. Here, we focus on unsupervised learning and employ generative models from ChemCam analysis. Further, we use labels (supervised) in combination to the generative model to compute uncertainties related to predictions. We report generative modeling can be successfully applied to model real-world data. Normalizing flow models can be efficiently constructed on latent spaces for fast downstream inference. Unsupervised and supervised learning can be combined to form an uncertainty quantification framework.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparing elemental measurements at packaging and after storage for signatures of chloride salt radiolysis

Radiolysis of hydrated alkaline earth chloride salts by alpha radiation from plutonium produces the chloride containing gases HCl and Cl 2 . These gases are known to diffuse out of the plutonium-containing material and contribute to corrosion outside of the convenience container. The alkaline earth elements remain with the plutonium-containing material as oxides or hydroxides. The amount of chlorine within the material after storage will be reduced compared to the amount at packaging. The fraction of the alkaline earth elements that are soluble after storage will be reduced compared to the amount at packaging. These signatures may be observable by comparing the chemical analysis measurements made at packaging and after storage. Comparison of measurements on a single Hanford container shows that the chloride does decrease and the alkaline earth elements have reduced solubility in water. Differences seen with other elements make conclusions difficult.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Discrete-event Simulation Process Model for the Pyrochemical Processing of Plutonium at Los Alamos National Laboratory

The pyrochemical metal production operations that occur in the Plutonium Facility at Los Alamos National Laboratory perform plutonium purification with the aim to provide plutonium metal for a variety of defense- and non-defense missions within the National Nuclear Security Administration. The demands and constraints associated with the pyrochemical processing of plutonium are complex, making decision analyses challenging for program managers who require plutonium production for their mission applications. The construction of a discrete-event simulation process model is proposed to measure and report the process capacity, material throughput, equipment requirements, and dose accumulation for operators of the pyrochemical metal production operations. The process model, constructed in the ExtendSim™ software, will represent the cause-and-effect relationships between the pyrochemical processing environment and the process constraints, including criticality limitations, material control and accountability measures, chemical analysis requirements, and equipment availability. An accurate representation of the pyrochemical metal production process capacity through simulation modeling will be helpful to program managers in their efforts to forecast plutonium availability for mission applications. Furthermore, the proposed process model will be vital for future analyses that will measure the interactions between the pyrochemical metal production operations and the aqueous reprocessing operations and their ability to minimize transuranic waste disposal.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Complex-Valued Signal Denoising and Bayesian Optimization for Detection of Synthetic Opioids [Slides]

Overseas manufacturers ship synthetic opioids into the United States through international mail. Synthetic opioids are largely responsible for the overdose crisis in the United States. Nuclear Quadrupole Resonance (NQR) spectroscopy is a chemical analysis technique used for detection. The ultimate goal is to develop a technology capable of detecting the presence of synthetic opioids in unopened packages using NQR spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Product Consistency Test Results for the LAW HPVR Glasses

This report summarizes the chemical analysis of Product Consistency Test (PCT) leachates received from Pacific Northwest National Laboratory (PNNL). The leachates are from a series of simulated nuclear waste glasses designated Low-Activity Waste High PCT and VHT Response (LAW HPVR) glasses that were designed and fabricated at PNNL. The glasses included both quenched and canister centerline cooled glasses. The reported data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. The elemental release for the study glasses is reported as normalized concentration (NC i ). NC i of several elements was computed for both the target and measured glass compositions, which were similar, resulting in no significant differences when computing the NC i values. The majority of the glasses exhibited NC B , NC Na , and NC Si values that were greater than the Hanford Tank Waste Treatment Plant (WTP) low-activity waste constraint of 4 g/L. Several blank solutions included with the study glasses had K, Na, and Si concentrations above the analytical detection limit. Additionally, several of the reference glasses that were included with the study glasses had Na concentrations that were higher than expected. The unexpected analyte concentrations in the reference glass and blank solutions were insignificant with respect to the reported NC i values, and are noted for completeness and their experimental relevance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing in-situ capabilities for synchrotron light source relevant to PNNL mission research areas

The main objective of the proposed research is to engage synchrotron light source capabilities to address the critical mission areas at PNNL. We have carried out Multi-model chemical analysis and imaging to unravel the role of surface chemistry during realistic heterogeneous interfacial processes - through a close collaboration that will help BES and BER research projects. In particular, we performed the following activities to understand role of surface chemistry on metal and oxide reactivity and metal ion transfer across oxide surface and aqueous solutions: 1) Perform light source experiments utilizing samples generated at PNNL; 2) Develop early career PNNL scientists utilizing light sources; 3) Build collaborations with ALS scientists in developing new in-situ capabilities; 4) Complete AMBER capabilities in collaboration with ALS scientists and make those available to the scientific community including PNNL scientists.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Product Consistency Test Results for the LAW ML1 Glasses

This report summarizes the chemical analysis of Product Consistency Test (PCT) leachates received from Pacific Northwest National Laboratory (PNNL). The leachates are from a series of quenched simulated nuclear waste glasses designated Low-Activity Waste Machine Learning (LAW ML1) glasses that were designed and fabricated at PNNL. The reported data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. The elemental release for the study glasses is reported as normalized concentration NCi. NCi of several elements was computed for both the target and measured glass compositions, which were similar, resulting in no significant differences. Several of the glasses exhibited NC B , NC Na , and/or NC Si values that were greater than the Waste Treatment Plant (WTP) low-activity waste constraint of 4 g/L. All reference glasses included with the study glasses had measurements that fell within the expected ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Product Consistency Test Results for the LAW Phase 5 Rerun Leachates

This report summarizes the chemical analysis of Product Consistency Test (PCT) leachates received from Pacific Northwest National Laboratory (PNNL). The leachates are from a series of quenched simulated nuclear waste glasses designated Low-Activity Waste Phase 5 (LP5) glasses that were designed and fabricated at PNNL. The reported data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. The elemental release for the study glasses is reported as normalized concentration (NC i ). NC i of several elements was computed for both the target and measured glass compositions. The majority of the glasses exhibited NC B , NC Na , and/or NC Si values that were greater than the Waste Treatment Plant (WTP) low activity waste constraint of 4 g/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LANL/UTEP Metallurgical Science Center of Excellence Planning

LANL seeks research assistance and skills development in three distinct subject areas over the next three years. Individualized scope and detail implementation schedules will be the first deliverable for these subject areas and will represent a joint determination between LANL SMEs and UTEP faculty based on LANL priority (schedule) and UTEP staffing (faculty and student- graduate and undergraduate) and capability of immediate availability per schedule. LANL will endeavor to make summer internships available to UTEP students within these subject areas: Chemical Sciences, Additive Manufacturing, and Metallurgy: casting and solidification, characterization, and metal purification. Unarticulated but generalized scoping tasks follow within each topical area to indicate that students and technicians familiar with these skill sets are of value and interest in LANL workforce pipeline and the tasks that seek to develop these skill sets are intentional on LANL's part. Consequently, LANL will sponsor 2-3 senior (capstone) projects within these subject areas per year over the three year time period within these task areas and within separations technologies, wet chemical analysis, and analytical characterization and quantification as required by all tasks.

36 MATERIALS SCIENCE↗

Product Consistency Test Results for the HLW HAlG Glasses

This report summarizes the chemical analysis of Product Consistency Test leachates received from Pacific Northwest National Laboratory (PNNL). The leachates are from a series of quenched simulated nuclear waste glasses designated High-Level Waste High Aluminum Glass that were designed and fabricated at PNNL. The reported data is provided to be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. The elemental release for the study glasses is reported as normalized concentration NCi. NCi of several elements was computed for both the target and measured glass compositions. Several of the glasses exhibited NC B , NC Li , and/or NC Na values that were greater than the Environmental Assessment (EA) benchmark values. Several of the leachates from approved reference material (ARM) glasses included with the study glasses had elemental concentrations greater than the expected ranges. Two water blanks contained measurable amounts of Si; measurements confirmed by rerun samples. One water blank also contained a measurable amount of Na.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metallurgical and mechanical characterization of ATP-5 aluminum alloys for minimizing machining distortion

ATP-5 aluminum alloy was considered as an alternative to 6061-T651 aluminum alloy to minimize machining distortion. ATP-5 is a proprietary cast alloy that is compositionally similar to 5083 aluminum and is purported to have excellent machinability, stability, and corrosion response. Dimensional stability tests, mechanical testing, chemical analysis, microstructural analysis, and fractography were completed to understand the metallurgy of the ATP-5 alloy and assess its potential as a 6061-T651 alloy alternative. Ultimately, the ATP-5 was found to retain dimensional stability issues, albeit to a lesser extent, relative to the 6061-T651 alloy. Combined with the residual cast structure observed microstructurally and lot-to-lot mechanical property variation, the alloy was deemed not suitable for a structural application. Alternative uses of ATP-5 include tooling, molds, vacuum chucks, fixtures, and jigs, where the material can shine in non-load bearing applications with a need for dimensional control and machinability.

36 MATERIALS SCIENCE↗

Low-Power Nuclear Heating Tests of UN Fuel Particles in Hydrogen Environment for Nuclear Thermal Propulsion

Recently, there has been a reemergence of interest within the space-exploration community regarding nuclear thermal propulsion (NTP) for interplanetary travel. NTP, as conceptualized, is a compact propulsion source, is relatively light because there is no need for an oxidizing agent and has a very high specific impulse compared to traditional forms of propulsion. These factors would reduce first-leg orbital-rocketry costs (by the source’s low weight and volume) and decrease overall travel time for astronauts with higher transit speeds. Idaho National Laboratory was provided bare, uncoated, and tungsten-coated uranium nitride fuel particles as part of a preliminary investigation. The fuel was fabricated by BWX Technologies and irradiated at the Massachusetts Institute of Technology research reactor. X-ray computed tomography and scanning electron microscopy and associated chemical analysis techniques were performed on these particles at Idaho National Laboratory. Both coated and uncoated forms were examined in the as-fabricated and as-irradiated conditions. The tungsten coating was found to be intact following the irradiation, indicating positive attributes for performance under these low-power-irradiation conditions. The irradiation of uncoated particles resulted in nitrogen enrichment at the edge of the particle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium fa values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9 .3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-I and Table ES-2, respectively. The experimental study, with four test conditions in triplicate, was performed in a dual glovebox with a nominally 3 vol.% H 2 in argon atmosphere (target H 2 range: 3 ± I vol.%). Simulants containing MgO only ( experimental control) and MgO+Fe 0 (WIPP base case) were prepared for both the Salado and Castile brines. MgO was included in all simulants to account for the use of bulk magnesium oxide in the WIPP repository. Fe 0 was included in some simulants to incorporate the effects of the anoxic corrosion of iron and in-situ hydrogen generation in the study. The brine compositions were developed by Sandia National Laboratory (SNL; Xiong, 2008) and have been used in previous WIPP evaluations. The test method (agitation, etc.) is partially based on ASTM D3987-12. Twelve rounds of periodic measurements of pH and E h were performed over the course of the study. Chemical analysis results for liquids and solids (ICP-MS, ICP-ES, IC Anion, TIC, SEM-EDX) are consistent with the pH, E h , and thermodynamic modeling results. This study included the following conditions that deviate from anticipated post-closure conditions following brine intrusion, but were selected to facilitate bench-scale testing to validate modeling of pH and E h for the post-closure WIP P repository: an anoxic glove box atmosphere containing ≤ 4 vol. % H 2 vs. substantially higher H 2 gas concentrations assumed in the WIPP Performance Assessment (PA); a significantly higher liquid-to-solid test ratio compared to the much lower phase ratio anticipated in the WIP P repository; agitation of the simulant bottles to maximize mass transfer; and finally the use of Fe 0 reagents having a much greater surface area than expected in the WIP P repository. Non-representative conditions were chosen for various reasons such as: to provide bounding conservative results, to provide a margin of safety for testing, or to facilitate simulant sub-sampling and analysis. In a parallel effort, aqueous electrolyte thermodynamic models were developed for the synthetic Salado and Castile brines to inform the experimental design, facilitate laboratory data interpretation, and allow extension of evaluations beyond the parameters tested. Thermodynamic modeling simulations including the MgO and Fe 0 additives that are directly relevant to the experimental measurements (e.g., pH calibration curve, ORP corrections) are included in this report. The measured fa of the simulants was close to the OLI model predictions for both brines and was largely controlled by the background H 2 partial pressure in the vapor phase as well as H 2 generated in situ in the aqueous phase by the Fe 0 corrosion. The H 2 gas-phase concentration tested and thermodynamically evaluated was much lower than is assumed in the WIPP PA; however, H 2 (g) concentrations significantly below this level are still predicted to result in very reducing conditions. In conclusion: • The experimental results are consistent with thermodynamic model predictions for fa, pH, and the effects of high ionic strength. • Evidence to date suggests that the H2 concentration in the glovebox atmosphere ultimately determined the final E h values of the simulants and resulted in highly reducing conditions. As a result, little difference was observed between the control simulants containing only MgO and the WIPP base-case simulants that contained MgO and Fe 0 . • This test methodology is recommended for future studies evaluating WIPP repository conditions. The methodology includes: (1) background H 2 in argon with agitation ( or could alternatively include in-situ-generated H 2 in sealed bottles); (2) carefully measured and corrected ORP data ( with much effort focused on allowing the probes to fully stabilize); and (3) ionic-strength-corrected pH data. Other best practices, such as simulant sparging/handling, ORP probe replacement, etc., should also be considered. • The coupling of experimental studies and thermodynamic modeling is also highly recommended because these methods inform and direct one another leading to greater confidence in and understanding of the results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concrete Compositions Used in Neutronics Analyses for Design of the Second Target Station Project

The purpose of this letter is to document the concrete compositions used by the Second Target Station (STS) Project Neutronics Group. Members of the Neutronics Group all have access to these compositions in our MCNP Master Model, which is stored on the ORNL GitLab server. It is expected that all STS Neutronics staff members will use these compositions in their analyses, unless all stakeholders agree to an exception. It is impossible to know the detailed composition of concrete before its constituents have been purchased, mixed, and a chemical analysis performed. Therefore, the STS Neutronics Group decided to use the same concrete compositions used by the Neutronics Group at the First Target Station (FTS). Furthermore, this leads to consistency between the analyses performed by the FTS and STS Neutronics Groups. The most important parameter to match between design simulations and construction regarding these concrete compositions is the density. Next in importance is the fraction of iron and hydrogen in the mixture.