Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

EMPIRE Simulations of the July 2020 photoelectron driven cavity B-Dot experiments at the National Ignition Facility

Simulations of several of the end-irradiated cylindrical photoelectron driven cavity experiments (also known as B-Dot cavities) that were fielded during the July 1 through 2, 2020 shot series at the National Ignition Facility are presented in this report with comparisons to experimental measurements. All cavity B-Dots fielded on the second, third, fourth, fifth and seventh shots were simulated using coupled Integrated Tiger Series (ITS) Monte Carlo transport codes and the Electromagnetic Plasmas in Realistic Environments (EMPIRE) electromagnetic particle-in-cell code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Computational Fluid Dynamic Simulation for Electrolyte Flow in Horizontal EP of Nb SRF Elliptical Cavities

An electrolyte flow velocity on an electropolishingsurface affects a material removal rate where higherremoval is observed with a higher velocity of theelectrolyte. In horizontal EP (HEP) of an ellipticalcavity, an electrolyte flow near the equator positionmight remain slow and responsible for a lowerremoval compared to that on the iris and beam pipepositions. In order to understand the flow dynamicon an elliptical cavity surface in the horizontal EPprocess, a computational fluid dynamic simulationwas conducted. This study was conducted on 1.3GHz cavity with different cathodes and acid flowrates. Final aim of the study is to improve the flowuniformity to attain uniform removal especially inmulticell cavities.

Chouhan, V.↗

Analyzing Mechanical integrity of Microwave resonant Cavity flowmeter

The microwave resonant cavity flow sensor has been proposed to address the difficulties of measuring high-temperature molten salt flow in reactor vessels. The flow sensor consists of a metallic cylindrical cavity coupled to a microwave waveguide. The cylindrical cavity has one of the flat surfaces thin enough to undergo microscopic deflection due to dynamic pressure of the exerted by the flowing fluid. Deflection of the membrane causes a shift in the microwave resonant frequency. Fluid velocity can be estimated from the calibration curve. The objective of this report is to investigate mechanical integrity of the flowmeter’s membrane. The membrane is a thin stainless-steel circular plate with a clamped edge, subjected to uniform load. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. If the maximum stress is greater than the yield strength, the plate will undergo plastic deformation, and the sensor will be disabled. A stress greater than the ultimate tensile strength will cause the plate to fracture. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Stresses in both the analytic model and COMSOL numerical model were calculated for stainless steel 316 thin circular plates under room temperature conditions, where the fluid is water. The diameter of the circular plate is approximately one inch, and thickness is 10mil. Fluid flow velocity is in the range from 0.5m/s to 1m/s. The results from the two models are similar. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pathways for a compact double-quarter wave cavity with low peak surface fields and large deflecting kick

This paper describes the parameter choices necessary to obtain a compact Double Quarter Wave (DQW) cavity with low peak surface fields – electric and magnetic – and large deflecting kick. The work is motivated by the space limitations and demanding crabbing voltage required for the crabbing system of the Electron-Ion Collider (EIC) and focuses on the optimization of the 197 MHz crab cavities for the EIC’s hadron ring. For a crabbing voltage of 11.5 MV, the optimized cavity is less than one meter long, showing a maximum peak surface magnetic field of 70 mT and a maximum peak surface electric field of 45 MV/m.

43 PARTICLE ACCELERATORS↗

EIC Transverse emittance growth due to crab cavity RF noise: Estimates and mitigation

The Electron-Ion Collider (EIC) requires crab cavities to compensate for a 25 mrad crossing angle and achieve maximum luminosity. The crab cavity Radio Frequency (RF) system will inject low levels of noise to the crabbing field, generating transverse emittance growth and potentially limiting luminosity lifetime. In this work, we estimate the transverse emittance growth rate as a function of the Crab Cavity RF noise and quantify RF noise specifications for reasonable performance. Finally, we evaluate the possible mitigation of the RF noise induced emittance growth via a dedicated feedback system.

43 PARTICLE ACCELERATORS↗

Penetration Bounds For Azimuthal Slot On Infinite Cylinder With Finite Length Backing Cylindrical Cavity

We examine coupling into azimuthal slots on an infinite cylinder with a infinite length interior cavity operating both at the fundamental cavity modal frequencies, with small slots and a resonant slot, as well as higher frequencies. The coupling model considers both radiation on an infinite cylindrical exterior as well as a half space approximation. Bounding calculations based on maximum slot power reception and interior power balance are also discussed in detail and compared with the prior calculations. For higher frequencies limitations on matching are imposed by restricting the loads ability to shift the slot operation to the nearest slot resonance; this is done in combination with maximizing the power reception as a function of angle of incidence. Finally, slot power mismatch based on limited cavity load quality factor is considered below the first slot resonance.

42 ENGINEERING↗

EMITTANCE GROWTH DUE TO RF PHASE NOISE IN CRAB CAVITIES

The Electron-Ion Collider (EIC) incorporates beam crabbing to recover geometric luminosity loss from the nonzero crossing angle at the interaction point (IP). It is well-known that crab cavity imperfections can cause growth of colliding beam emittances, thus degrading collider performance. Here we report a particle tracking study to quantify these effects. Presently the study is focused on crab cavity RF phase noise. Simulations were carried out using Bmad. Dependence of emittance growth on phase noise level was obtained which could be used for developing crab cavity phase control specifications. We also benchmarked these simulations with theory.

Huang, H.↗

Plasma Processing of SRF Cavities at Jefferson Lab

Jefferson Lab has an ongoing R&D program in plasma processing which is close to going into production pro-cessing in the CEBAF accelerator. Plasma processing is a common technique for removing hydrocarbons from surfaces, which increases the work function and reduces the secondary emission coefficient [1]. The initial focus of the effort is processing C100 cavities by injecting RF power into the HOM coupler ports. The goal will be to improve the operational gradients and the energy margin of the CEBAF linacs by processing cryomodules in situ. Results from processing a cryomodule in the cryomodule test bunker as well as cavity vertical test results will be presented. This work describes the systems and methods used at JLAB for processing cavities using an ar-gon/oxygen gas mixture.

Powers, T.↗

Overview on Recent Development of Conduction Cooling Cavities

Improvements in both the cooling power of 4 K crycoolers and the deposition of Nb3Sn films have spurred research and development efforts towards the operation of Nb3Sn-coated SRF cavities cooled by conduction with commercial cryocoolers. Different types of SRF cavities with frequencies between 650 MHz and 2.6 GHz and different conduction cooling schemes have been tested at different laboratories, demonstrating accelerating gradients up to ~10 MV/m. This contribution provides an overview of these and future efforts along with possible cryostat designs under evaluation for conduction-cooled SRF cavities.

Ciovati, G.↗

Review of the application piezoelectric actuators for SRF cavity tuners

Modern particle accelerators and high-energy physics experiments that deployed up to several hundred of accelerating superconducting RF cavities require accurate frequency control. This is achieved by using cavity tuners typically actuated with the piezoelectric ceramic actuators. Piezoelectric ceramic actuators have become “standard” components of the SRF cavity tuner and depending on the application could be operated in different environments: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters common to all applications are the lifetime and reliability of the actuators. Several programs targeting the development of reliable piezo actuators are presented in this contribution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Manufacturing the Harmonic Kicker Cavity Prototype for the Electron-Ion Collider

High-bunch-frequency beam-separation schemes, such as the injection scheme proposed for the Rapid Cycling Synchrotron at the Electron-Ion Collider, demand rise and fall times an order of magnitude below what can realistically be accomplished with a stripline kicker. Nanosecond-time-scale kick waveforms can instead be obtained by Fourier synthesis in a harmonically resonant quarter-wave radio-frequency cavity which is optimized for high shunt impedance. Originally developed for the Jefferson Lab Electron-Ion Collider (JLEIC) Circulator Cooler Ring, a hypothetical 11-pass ring driven by an energy-recovery linac at Jefferson Lab, our high-power prototype of such a harmonic kicker cavity, which operates at five modes at the same time, will demonstrate the viability of this concept with a beam test at Jefferson Lab. As the geometry of the cavity, tight mechanical tolerances, and number of ports complicate the design and manufacturing process, special care must be given to the order of the manufacturing steps. We present our experiences with the manufacturability of the present design, lessons learned, and first RF test results from the prototype.

Overstreet, S. A.↗

Advances in SRF cavity architectures for quantum computing

Superconducting radio frequency (SRF) cavities offer an excellent platform for storing and processing quantum information due to their exceptionally long lifetimes and large accessible Hilbert spaces. A common strategy to manipulate the quantum states is to use a nonlinear element like a transmon. Nevertheless, constructing a 3D SRF architecture with sustained cavity lifetimes presents several challenges. In this talk, we present our successful integration of transmons with single-cell Nb SRF cavities, enabling the preparation of several non-classical states. Preliminary results reveal the potential of this platform to build a qudit-based quantum computer, departing from traditional qubit-based architectures. We discuss strategies to enhance coherence times, develop high-fidelity gate schemes, and expand the system for constructing a multi-qudit quantum processor. Furthermore, we explore how this architecture can bolster dark matter detection efficiency through multi-photon quantum state preparation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards multi-qudit quantum processor using superconducting RF cavities

Superconducting radio-frequency (SRF) cavities made using high-purity Niobium can reach single photon lifetimes longer than a second with proper treatment [1]. These resonator cavities are thus an excellent choice for storing higher-dimensional quantum states. However, preparing and manipulating quantum states with larger photon numbers require a nonlinear component, like a transmon, with a sufficiently long coherence time. With the advancement in materials processing enabling coherence times for transmons exceeding hundreds of micro-seconds, one can encode and process quantum information using d-levels (qudit) of the resonators. In this talk, we will present preliminary results showing the control of a single-qudit and our progress toward building multi-qudit architecture using multi-mode SRF cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase-controlled enhancement of photon lifetime in coupled superconducting cavities.

The photon lifetime of superconducting cavities is essential forthe long coherence of quantum computing units and sensors. Wediscover that the photon lifetime of cavity field in a couple- cavitysystem is modified by the phases of the initial states and thephase in the coupling channel. Experimentally by performingring-down measurement for two coupled 3D superconductingcavities, we observed a factor of two enhancement in cavityphoton lifetime. The result open new avenues for improvingperformances of superconducting cavities and quantum systems.

43 PARTICLE ACCELERATORS↗

High Q SRF cavity-based searches for beyond the standard model physics

The SRF technology developed for accelerators can be successfully applied to new applications, including quantum computing, dark matter searches and beyond the standard model physics. The ultra-high quality factor of SRF cavities can enable unprecedented sensitivity in fields outside of the usual accelerator applications, for examples fundamental and beyond the standard model physics. Applications of SRF cavities for gravitational waves searches are also being investigated. The SQMS Physics and Sensing thrust is working on this effort as it strives to combine SRF cavities with QIS, with a focus on BSM and fundamental physics.

Berlin, A.↗

Design and Prototyping of the Electron Ion Collider Electron Storage Ring SRF cavity

Among the EIC?s numerous RF subsystems, the electron storage ring?s (ESR) 591 MHz fundamental RF system is one of the most challenging. Each cavity in the system will handle up to 2.5 A of beam current and supply up to 600 kW beam power under a wide range of voltage. The EIC R&D plan includes the design, fabrication and testing of such a cavity. In this paper, we will report the latest status and findings of the ongoing design and prototyping of this cavity, including the RF and mechanical/thermal design, fabrication design, and the progress of fabrication.

Guo, Jiquan↗

Dark Matter and other BSM searches with SRF cavities at SQMS

The Superconducting Quantum Materials and Systems Center, led by Fermi National Accelerator Laboratory, is one of five research centers funded by the U.S. Department of Energy as part of a national initiative to develop and deploy the world’s most powerful quantum computers and sensors. The SQMS Center uses world-record quality-factor superconducting radio-frequency, or SRF, cavities as ultra-sensitive quantum probes. Cavities combined with superconducting transmon qubits can be the building block of a quantum computer, and they can also be employed for fundamental physics searches. Within the quantum sensing thrust, researchers are developing experiments based on cavities and novel quantum devices to search for particles beyond the Standard Model, dark matter candidates, gravitational waves and fundamental material properties. The seminar will present a brief overview of the center and focus on the physics and sensing work conducted at Fermilab.

43 PARTICLE ACCELERATORS↗

Dark Matter and other BSM searches with SRF cavities at SQMS

The Superconducting Quantum Materials and Systems Center, led by Fermi National Accelerator Laboratory, is one of five research centers funded by the U.S. Department of Energy as part of a national initiative to develop and deploy the world’s most powerful quantum computers and sensors. The SQMS Center uses world-record quality-factor superconducting radio-frequency, or SRF, cavities as ultra-sensitive quantum probes. Cavities combined with superconducting transmon qubits can be the building block of a quantum computer, and they can also be employed for fundamental physics searches. Within the quantum sensing thrust, researchers are developing experiments based on cavities and novel quantum devices to search for particles beyond the Standard Model, dark matter candidates, gravitational waves and fundamental material properties. The seminar will present a brief overview of the center and focus on the physics and sensing work conducted at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗