Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Uncertainty Quantification of Calculated Temperatures for the AGR 5/6/7 Experiment

This report documents the quantification of uncertainty of the calculated temperature data for the Advanced Gas Reactor (AGR) 5/6/7 fuel irradiation experiment conducted in the Advanced Test Reactor at Idaho National Laboratory in support of the Advanced Reactor Technologies? research and development program. Recognizing uncertainties inherent in physics and thermal simulations of the AGR 5/6/7 capsules, the results of the numerical simulations are used in combination with statistical analysis methods to improve qualification of measured data. The calculated fuel temperatures for AGR tests are also used for validation of the fission product transport and fuel performance simulation models. These crucial roles of the calculated fuel temperatures in ensuring achievement of the AGR experimental program objectives require accurate determination of the model temperature uncertainties. This report covers temperature uncertainty results for each of the five AGR 5/6/7 capsules. To quantify the uncertainty of calculated temperatures determined using the ABAQUS finite element heat transfer code, this study identifies and analyzes model parameters of potential importance to the calculated temperatures of fuel compacts and thermocouples. The selection of input parameters for uncertainty quantification is based on the ranking of their influences upon temperature predictions. Thus, selected input parameters include those with high sensitivity and those with the largest uncertainty. Propagation of model parameter uncertainty and sensitivity is then used to quantify the overall uncertainty of calculated temperatures. Measurement uncertainty, analysis of modeling assumptions, and expert judgment are used as the basis to quantify the uncertainty range for selected input parameters. The input uncertainties are dynamic, accounting for the effect of unplanned events and changes in thermal properties of capsule components over extended exposure to high temperatures and fast neutron irradiation. The sensitivity analysis performed in this work went beyond the traditional local sensitivity. Using experimental design, analysis of pairwise interactions of model parameters was performed to establish sufficiency of the time dependent first order (linear) expansion terms in constructing the temperature response surface. To achieve completeness, uncertainty propagation made use of pairwise noise correlations of model parameters. Furthermore, using an interpolation scheme over the input parameter domain, the analysis obtains time dependent sensitivity over the test campaign duration. This allows computation of uncertainty for the calculated fuel temperatures and the calculated graphite temperatures at thermocouple locations during the entire irradiation period.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of an Analytical Model for Therapeutic and Stray Dose Calculations of 6 MV Photon Beams

Cancer is one of the most significant health care problems today. It is estimated that 1 in 2 men and women will be diagnosed with some form of cancer in their lifetime. Nearly two thirds of cancer patients will receive radiation therapy at some point in their care and the vast majority of these radiotherapy treatments will be performed with megavoltage photon therapy. Photon treatment techniques typically devote considerable attention to limiting the exposure of healthy tissues outside of the intended treatment volume. Nonetheless, small levels of unwanted stray radiation are incident upon the patient's whole body, which can increase the risk for numerous late effects, including second malignancies. When one considers that second cancers account for approximately 15% of all cancers and that it is projected that by the year 2020, there will be almost 20 million cancer survivors in the United States and four million in the UK, the need for improved accuracy in stray dose calculations appears likely to increase dramatically. Despite the obvious benefits this capability would afford, contemporary commercial treatment planning systems (TPSs) lack the ability to accurately predict stray dose outside the treatment field, e.g., beyond the 5% isodose surface. Thus, there is a large, variable, and systematic underestimation of stray radiation exposures by commonly used clinical TPSs for photon therapy. To overcome this problem, in a companion paper we proposed a simple, physics-based analytical model that calculates the total therapeutic and stray dose from photon treatment fields. The purpose of this work was to evaluate the accuracy of the basic physics in the analytical absorbed dose model for several simple treatment fields. We assessed the performance of the basic physics in an analytical model that calculates the total absorbed dose deposited by primary, leakage, and scattered photons both inside and outside of square treatment fields of 6 MV photon conventional radiotherapy. The assessment was accomplished by comparing model predictions of total dose with measured dose profiles in a water-phantom. The major finding of this study is that the physics-based model performed well, predicting dose in water within 11.5% dose difference or 5 mm distance to agreement with measured values in the therapeutic region and within 1.1 mGy/Gy or 0.5 mm distance to agreement with measured values in the out-of-field region at 90% of the locations considered. Contemporary external-beam photon TPSs do not include the capability to accurately predict the absorbed dose beyond a few centimeters outside of the treatment field. Our work suggests that it is feasible to improve dosimetric accuracy in the out-of-field region using a simple and computationally fast, physics-based analytical algorithm. This is demonstrated by the measured absorbed dose as well as the corresponding values calculated by two contemporary commercial TPSs (Pinnacle, Philips Health care, Andover, MA and Eclipse, Varian Medical Systems, Inc., Palo Alto, CA) and the analytical model considered in this work. It is apparent that both TPSs underestimated the absorbed dose by greater than 3 mGy/Gy at locations outside of the 0.5% relative dose level. In contrast, the analytical model evaluated in this work calculated absorbed dose in the same region within 0.4 mGy/Gy of measured values. The physics-based analytical dose model could prove useful in a number of different applications. The accurate knowledge of absorbed dose deposited outside of the treatment field is especially important for predicting radiation late effects, such as second cancer, fertility complications, and cardiac toxicity. It may also facilitate predictions of the effects of in utero exposure. We conclude that it is possible to accurately calculate the therapeutic and stray absorbed dose from a conventional radiotherapy treatment field of 6 MV photons using a physics-based analytical model. This was demonstrated by the agreement between measured and calculated doses in water within 11.5% relative dose difference or 5 mm distance to agreement in the therapeutic region, and within 1.1 mGy/Gy absolute dose difference or 0.5 mm distance to agreement in the out-of-field region at 90% of positions for all of the fields considered in this work. This is also illustrated by Figure 4 which plots dose values from analytical model predictions and measurements at five representative irradiation conditions and shows that the analytical model agreement is good in all cases. Furthermore, the model validated in this work evidently can predict dose values with better accuracy at out-of-field locations than contemporary TPSs. This and previous works, taken together, suggest that analytical physics-based models will offer advantages over TPSs or Monte Carlo models for whole-body dose calculations for several radiotherapy applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radionuclide Inventory Calculations for the Calcined Solid Storage Facility Performance Assessment - 19292

Originally named the Idaho Chemical Processing Plant when it was constructed in the early 1950's, the Idaho Nuclear Technology and Engineering Center reprocessed SNF to recover highly enriched uranium and other nuclear-related products for the U.S. DOE. Reprocessing SNF generated millions of gallons of aqueous radioactive waste. Calcination was a process developed at the INL Site to convert liquid waste into a solid, granular form from 1963 to 2000. The calcination process produced a safer product for storage while reducing the volume of stored liquid waste by an average factor of seven. Calcine is currently stored in the Calcined Solids Storage Facility (CSSF). The CSSFs are often called 'bin sets' because each CSSF (CSSFs 1 through 6) contains several stainless-steel storage bins housed in a concrete vault. The CSSF is an interim waste storage facility. In the future, calcine will be retrieved, treated (if necessary), and sent to an off-Site facility for storage or disposal. To close the CSSF, the bulk of the calcine will be removed and stored or disposed of elsewhere. The bins and vaults will then be placed in a configuration that is protective of human health and the environment. For purposes of the performance assessment, the depth of the residual calcine at closure was assumed to be 5-cm in each bin. The 5-cm of residual calcine in each bin is assumed to be mixed in grout during closure. The activities of the residual radionuclides are the inventory used for the dose assessment calculations for the CSSF performance assessment. The objective of this analysis was to calculate the radionuclide activity in the residual calcine remaining in the CSSF after closure. The purpose of this paper is to present the approach used to calculate the radionuclide inventory of the calcine currently stored in CSSF and the residual calcine in the CSSF after closure using data from the calcined waste Historical Processing Model (HPM). Limited sampling and analysis of the calcine in the CSSF bins was conducted in the past. Future similar calcine sampling and analysis efforts would be costly, generate additional mixed waste, and may not provide the desired detailed calcine composition data. However, during the later years of calcining, an alternative to calcine sampling and analysis was developed and the information was captured in the HPM. The HPM uses multiple sources to provide definitive calcine volume, mass, and composition, including: compositions and volumes of the liquid wastes that were calcined, ORIGEN2 - and ORIGEN-ARP-based radioactivity calculations, calciner and CSSF operating data, and process knowledge of INTEC fuel and waste-processing systems. HPM calcine composition was used to develop an inventory of radionuclides for use in the performance assessment evaluation for closure of CSSF. There are 43 bins that contain calcine, with six to twelve segments in each bin for a total of 337 bin segments for which the HPM calculates the average calcine composition. The HPM calculates the composition of each of the nearly 7,000 batches of material (startup bed, nonradioactive material, and radioactive waste) charged to the calciners. The calculations use the CSSF dimensions, including the CSSF number of bins, heights, outside diameters, annular air space diameter (if necessary), and volume of calcine currently in the bins. For each of the CSSFs, for a 5-cm residual, the percent of total calcine was calculated along with the residual activity for the radionuclides. Residual activity was estimated for 148 different radionuclides. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculating Potential Radiological Emissions for Waste Management Activities at INL - 20068

At Idaho National Laboratory (INL), work involving radionuclides is evaluated for potential emissions from a project in order to comply with the National Emission Standards for Hazardous Air Pollutants (NESHAP) regulations, 40 CFR 61 Subpart H. Emission calculations are documented in an Air Permitting Applicability Determination (APAD) to analyze unmitigated and mitigated emissions and determine if an Application to Construct (ATC) or continuous monitoring is required. To calculate the unmitigated and mitigated emissions, a spreadsheet was developed to provide ease in determining potential emissions by providing the maximum operating temperature and the material being used. The spreadsheet aids in determining the potential emissions for research projects and waste management activities at Materials and Fuels Complex (MFC) and other locations across the INL site. Furthermore, it can also be used for periodic confirmatory measurements (PCM) to justify low emissions. Elements that factor into the unmitigated and mitigated calculations include the amount of each radionuclide used (in curies or grams), specific activity (if amount is given in grams), the temperature the material is heated to in Celsius, the dose conversion factor which is derived from Clean Air Act Assessment Package - 1988 (CAP-88) modeling, and the number of HEPA filters used for mitigated measures. The main drivers for calculating the unmitigated emissions for a project are the amount used per radionuclide, the maximum operating temperature, and the location of the work. The maximum operating temperature determines the airborne release factor which is dependent on the physical state of the radionuclide. Prior to October 2017, if the radionuclide was heated to greater than 100 deg. C, the radionuclide was assumed to be a gas, which has the highest airborne release factor. This assumption would be overly conservative for radionuclides with high melting and boiling points, which provided a challenge to demonstrate low emissions. In October 2017, the Environmental Protection Agency (EPA) approved an alternative method for INL. This method allows the airborne release factor to be determined by using the melting point and 90% of the boiling point of the radionuclide. This methodology was included in the spreadsheet to allow unmitigated emission calculations for APADs to be completed more efficiently and effectively. Results show a reduction in time completing air emission calculations as well as lower total emissions across all facilities at INL. MFC annual emissions were reduced by 62% from the previous year and Research and Education Campus (REC) facilities were reduced by 38% due to implementation of the approved alternative method. Time spent on APADs, PCMs, and documentation for the annual NESHAP report was also reduced significantly. The spreadsheet provided in Table I provides the potential emission calculations for the 'Advanced Retrieval and Disposition Techniques for Remote Handled Mixed Low Level Waste (RH MLLW) at the Radioactive Scrap and Waste Facility (RSWF)' project. Calculations show the Potential Effective Dose Equivalent (PEDE) at RSWF to be 7.27 E-04 mrem/yr (7.27 E-09 Sv/yr) which is well below the 0.1 mrem/yr threshold. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heterogeneous Neutron Leakage Model for PWR Pin-by-pin Calculation

In the last few decades, the nodal diffusion calculation accompanied with the assembly homogenization has been widely employed. The single assembly calculation with the reflective boundary condition (BC) would be carried out to determine the assembly-homogenized parameters. Because of the reflective BC, no axial and/or radial leakage rates have been taken into accounted for the lattice calculation. To represent the global influence of the reactor core on an assembly calculation, one mostly frequently uses a procedure called leakage model to approximately take into account the absorption due to the macroscopic structure of the physical flux in a heterogeneous situation. For the assembly homogenization, this absorption is introduced as the product of the leakage coefficient and the buckling obtained for an equivalent homogeneous medium using the well-known homogeneous B1 theory. Clearly, this is an imperfect representation of leakages in a heterogeneous medium. However, the errors introduced by the foregoing procedure are small for the whole? -assembly homogenization in a PWR. When it comes to the pin-by-pin calculation, it is not the case. The leakage rate? will be affected by the neutron streaming effect caused by the heterogeneity of the assembly. Especially when poison pins or empty channels are present, the streaming effect becomes important. The errors introduced appear particularly visible. The heterogeneous leakage model? which assumes that the neutron flux is variational and the leakage rate is not uniform over the lattice pitch is a more appropriate choice. When the heterogeneous leakage model is applied in the lattice calculation for the pin-cell homogenization, the pin-homogenized problem would be changed compared with the original assembly problem without any homogenization technique. So, the Cooperation of the heterogeneous leakage model with the pin-cell homogenization theory is unsettled. In this paper, both homogenous and heterogeneous leakage models are evaluated in pin-by-pin calculation. Their implements used in pin-cell homogenization of the lattice calculation are studied. The diffusion coefficient obtained from transport cross-section and the space-dependent leakage coefficient together with the two leakage models are analyzed for the practical reactor-core applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spherical Target Temperature by Extended CFAST Calculation

The purpose of this calculation is to evaluate the temperature at the surface of a spherical target made of polyethylene during a room fire. The current calculation is separated into 2 steps: (1) CFAST code calculation--Calculate the air temperature; radiation flux to the target from the fire, surrounding air, and walls; convection flux; and target temperature. (2) Extended model calculation--Calculate the temperature of the target sphere taking into account the density, heat capacity, heat conductivity, and the spherical geometry of the target by solving the coupled finite difference equations. The second step calculation utilizes the air temperature and radiation flux determined by the CFAST code calculation in the first step.

99 GENERAL AND MISCELLANEOUS↗

QSL Squasher: A Fast Quasi-separatrix Layer Map Calculator

Quasi-Separatrix Layers (QSLs) are a useful proxy for the locations where current sheets can develop in the solar corona, and give valuable information about the connectivity in complicated magnetic field configurations. However, calculating QSL maps, even for two-dimensional slices through three-dimensional models of coronal magnetic fields, is a non-trivial task, as it usually involves tracing out millions of magnetic field lines with immense precision. Thus, extending QSL calculations to three dimensions has rarely been done until now. In order to address this challenge, we present QSL Squasher—a public, open-source code, which is optimized for calculating QSL maps in both two and three dimensions on graphics processing units. The code achieves large processing speeds for three reasons, each of which results in an order-of-magnitude speed-up. (1) The code is parallelized using OpenCL. (2) The precision requirements for the QSL calculation are drastically reduced by using perturbation theory. (3) A new boundary detection criterion between quasi-connectivity domains is used, which quickly identifies possible QSL locations that need to be finely sampled by the code. That boundary detection criterion relies on finding the locations of abrupt field-line length changes, which we do by introducing a new Field-line Length Edge (FLEDGE) map. We find FLEDGE maps useful on their own as a quick-and-dirty substitute for QSL maps. QSL Squasher allows construction of high-resolution 3D FLEDGE maps in a matter of minutes, which is two orders of magnitude faster than calculating the corresponding 3D QSL maps. We include a sample of calculations done using QSL Squasher to demonstrate its capabilities as a QSL calculator, as well as to compare QSL and FLEDGE maps.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Cone-Beam Tomography and Cross-Sectional Imaging for Volumetric and Dosimetric Calculations in Resin Yttrium-90 Radioembolization

PurposeTo compare the use of cone-beam computed tomography versus contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) in the calculation of liver volume and planned dose for yttrium-90 radioembolization.Materials and MethodsThe study retrospectively assessed 47 consecutive patients who underwent resin Y-90 radioembolization consecutively over a 2-year period at a single center. Volume calculation software was used to determine perfused lobar liver volumes from cone-beam CT (CBCT) images obtained during mapping angiography. CBCT-derived volumes were compared with perfused lobar volume derived from contrast-enhanced CT and MRI. Nominal activities as determined by the SIR-Spheres Microspheres Activity Calculator were similarly calculated and compared using both CBCT and conventionally acquired volumes.ResultsA total of 82 hepatic lobes were assessed in 47 patients. The mean percentage difference between combined CT-MRI- and CBCT-derived calculated lobar volumes was 25.3% (p = 0.994). The mean percentage difference in calculated dose between the two methods was 21.8 ± 24.6% (p = 0.42). Combined left and right lobar CT-derived dose difference was less than 10% in 22 lobes, between 10 and 25% in 20 lobes, between 25 and 50% in 13 lobes and greater than 50% in 5 lobes. Combined left and right lobar MRI-derived dose difference was less than 10% in 11 lobes, between 10 and 25% in 7 lobes, between 25 and 50% in 2 lobes and greater than 50% in 1 lobe.ConclusionsAlthough volume measurements derived from CT/MRI did not differ significantly from those derived from CBCT, variability between the two methods led to large and unexpected differences in calculated dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multilayer Divide-Expand-Consolidate Coupled-Cluster Method: Demonstrative Calculations of the Adsorption Energy of Carbon Dioxide in the Mg-MOF-74 Metal–Organic Framework

The implementation and evaluation of a multilayer extension of the divide-expand-consolidate (DEC) scheme within the LSDalton program is presented. The DEC scheme is a linear-scaling, fragmentation-based local coupled-cluster (CC) method that provides a means of overcoming the scaling wall associated with canonical CC electronic structure calculations on large molecular systems. Taking advantage of the local nature of correlation effects, the correlation energy for the full molecule is calculated from a set of independent fragments using localized molecular orbitals. However, when only a small subsystem of a larger system is of interest, for example, adsorption sites or catalytically active sites, the majority of the computational time may be spent evaluating the correlation energy of fragments which have little effect on the properties in the area of interest (AOI). The multilayer DEC (ML-DEC) scheme addresses this by taking advantage of the independent nature of the fragments in order to evaluate the correlation energy of various regions of the system at different levels of theory. Regions far from the AOI are evaluated at lower (cheaper) levels of theory such as Hartree–Fock (HF) or Møller–Plesset second-order perturbation theory (MP2), while the area immediately surrounding the AOI is treated with a higher level CC model. Through the ML-DEC scheme, the computational cost of CC calculations on these types of systems can be significantly reduced while maintaining the accuracy of higher-level calculations. Results from HF/RI-MP2 and RI-MP2/CCSD ML-DEC calculations of the binding energy of a fatty acid dimer are presented. We find that the ML-DEC scheme is capable of reproducing DEC energy differences at a target level of theory, provided that the region treated at the target level of theory is chosen to be sufficiently large. Time-to-solution is found to be significantly reduced, particularly in the RI-MP2/CCSD calculations. Finally, the ML-DEC scheme is applied to the calculation of CO 2 adsorption in a Mg-MOF-74 channel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculation method using Clarkson integration for the physical dose at the center of the spread-out Bragg peak in carbon-ion radiotherapy

Purpose: In broad-beam carbon-ion radiotherapy performed using the heavy-ion medical accelerator in Chiba, the number of monitor units is determined by measuring the physical dose at the center of the spread-out Bragg peak (SOBP) for the treatment beam. The total measurement time increases as the number of treatment beams increases, which hinders the treatment of an increased number of patients. Hence, Kusano et al.[Jpn. J. Med. Phys. 23(Suppl. 2), 65-68 (2003)] proposed a method to calculate the physical dose at the center of the SOBP for a treatment beam. Based on a recent study, the authors here propose a more accurate calculation method.Methods: The authors measured the physical dose at the center of the SOBP while varying the circular field size and range-shifter thickness. The authors obtained the physical dose at the center of the SOBP for an irregularly shaped beam using Clarkson integration based on these measurements.Results: The difference between the calculated and measured physical doses at the center of the SOBP varied with a change in the central angle of the sector segment. The differences between the calculated and measured physical doses at the center of the SOBP were within {+-}1% for all irregularly shaped beams that were used to validate the calculation method.Conclusions: The accuracy of the proposed method depends on both the number of angular intervals used for Clarkson integration and the fineness of the basic data used for calculations: sampling numbers for the field size and thickness of the range shifter. If those parameters are properly chosen, the authors can obtain a calculated monitor unit number with high accuracy sufficient for clinical applications.

60 APPLIED LIFE SCIENCES↗

SU-E-T-464: Implementation and Validation of 4D Acuros XB Dose Calculations

Purpose: In this abstract we implement and validate a 4D VMAT Acuros XB dose calculation using Gafchromic film. Special attention is paid to the physical material assignment in the CT dataset and to reported dose to water and dose to medium. Methods: A QUASAR phantom with a 3 cm sinusoidal tumor motion and 5 second period was scanned using 4D computed tomography. A CT was also obtained of the static QUASAR phantom with the tumor at the central position. A VMAT plan was created on the average CT dataset and was delivered on a Varian TrueBeam linear accelerator. The trajectory log file from this treatment was acquired and used to create 10 VMAT subplans (one for each portion of the breathing cycle). Motion for each subplan was simulated by moving the beam isocentre in the superior/inferior direction in the Treatment Planning System on the static CT scan. The 10 plans were calculated (both dose to medium and dose to water) and summed for 1) the original HU values from the static CT scan and 2) the correct physical material assignment in the CT dataset. To acquire a breathing phase synchronized film measurements the trajectory log was used to create a VMAT delivery plan which includes dynamic couch motion using the Developer Mode. Three different treatment start phases were investigated (mid inhalation, full inhalation and full exhalation). Results: For each scenario the coronal dose distributions were measured using Gafchromic film and compared to the corresponding calculation with Film QA Pro Software using a Gamma test with a 3%/3mm distance to agreement criteria. Good agreement was found between calculation and measurement. No statistically significant difference in agreement was found between calculations to original HU values vs calculations to over-written (material-assigned) HU values. Conclusion: The investigated 4D dose calculation method agrees well with measurement.

60 APPLIED LIFE SCIENCES↗

SU-F-T-430: Validation of IBEAM Evo Couch Top for Different Relative Electron Density (RED) Combination During Photon Beam Dose Calculation in Monaco− Treatment Planning System

Purpose: Validation of iBEAM™ evo couch-top for different relative electron density (RED) combination during photon beam dose calculation in Monaco− TPS. Methods: The iBEAM™ evo couch-top has two layers:outer carbon fiber (CF) and inner foam core (FC). To study the beam intensity attenuation of couch-top, measured doses were compared with doses calculated for different REDs. Measurements were performed in solid water phantom with PTW-0.125cc ion-chamber positioned at center of the phantom with 5.3cm thickness slabs placed above and below the chamber. Similarly, in TPS, iBEAM™ evo couch-top was simulated and doses were calculated for different RED combinations (0.2CF-0.2FC, 0.4CF-0.2FC, 0.6CF-0.2FC, 0.8CF-0.2FC, and 1.0CF-0.2FC) by using Monte Carlo dose calculation algorithm in Monaco TPS (V5.1). Doses were measured for every 10 degree gantry angle separation, 10×10cm{sup 2} field size and 6MV photons. Then, attenuation is defined as the ratio of output at posterior gantry angle to output of its opposed anterior gantry angle (e.g.225°/45°). output fluctuation with different gantry angle was within ±0.21%. To confirm above results, dose-planes were measured for five pelvic VMAT plans (360°arc) in PTW two-dimensional array and compared with different calculated dose-planes of above-mentioned couch REDs. Gamma pass rates<1.00) were analyzed for 3%/2mm criteria. Results: Measured and calculated attenuation was in good agreement for the RED combination of 0.2CF-0.2FC and difference was within ±0.515%. However, other density combination showed difference of ±0.9841%, ±1.667%, ±2.9241% and ±2.8832% for 0.4CF-0.2FC, 0.6CF-0.2FC, 0.8CF-0.2FC, and 1.0CF-0.2FC, respectively. Maximum couch-top attenuation was observed at 110°–120° and 240°–250° and decreases linearly as the gantry angle approaches 180°. Moreover, gamma pass rate confirmed the above results and showed maximum pass rate of 96.23% for 0.2CF-0.2FC, whereas others were 95.72%, 95.12%, 94.31% and 93.24%. Conclusion: RED value of 0.2CF-0.2FC was found to be suitable for accurate couch-top modeling for 6MV photon beam Monte Carlo calculations in Monaco TPS.

07 ISOTOPE AND RADIATION SOURCES↗

TU-D-201-05: Validation of Treatment Planning Dose Calculations: Experience Working with MPPG 5.a

Purpose: Newly published medical physics practice guideline (MPPG 5.a.) has set the minimum requirements for commissioning and QA of treatment planning dose calculations. We present our experience in the validation of a commercial treatment planning system based on MPPG 5.a. Methods: In addition to tests traditionally performed to commission a model-based dose calculation algorithm, extensive tests were carried out at short and extended SSDs, various depths, oblique gantry angles and off-axis conditions to verify the robustness and limitations of a dose calculation algorithm. A comparison between measured and calculated dose was performed based on validation tests and evaluation criteria recommended by MPPG 5.a. An ion chamber was used for the measurement of dose at points of interest, and diodes were used for photon IMRT/VMAT validations. Dose profiles were measured with a three-dimensional scanning system and calculated in the TPS using a virtual water phantom. Results: Calculated and measured absolute dose profiles were compared at each specified SSD and depth for open fields. The disagreement is easily identifiable with the difference curve. Subtle discrepancy has revealed the limitation of the measurement, e.g., a spike at the high dose region and an asymmetrical penumbra observed on the tests with an oblique MLC beam. The excellent results we had (> 98% pass rate on 3%/3mm gamma index) on the end-to-end tests for both IMRT and VMAT are attributed to the quality beam data and the good understanding of the modeling. The limitation of the model and the uncertainty of measurement were considered when comparing the results. Conclusion: The extensive tests recommended by the MPPG encourage us to understand the accuracy and limitations of a dose algorithm as well as the uncertainty of measurement. Our experience has shown how the suggested tests can be performed effectively to validate dose calculation models.

60 APPLIED LIFE SCIENCES↗

Verification of EPA's ''Preliminary Remediation Goals for radionuclides'' (PRG) electronic calculator

The U.S. Environmental Protection Agency (EPA) requested an external, independent verification study of their updated “Preliminary Remediation Goals for Radionuclides” (PRG) electronic calculator. The calculator provides PRGs for radionuclides that are used as a screening tool at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) and Resource Conservation and Recovery Act (RCRA) sites. These risk-based PRGs establish concentration limits under specific exposure scenarios. The purpose of this verification study is to determine that the calculator has no inherit numerical problems with obtaining solutions as well as to ensure that the equations are programmed correctly. There are 167 equations used in the calculator. To verify the calculator, all equations for each of seven receptor types (resident, construction worker, outdoor and indoor worker, recreator, farmer, and composite worker) were hand calculated using the default parameters. The same four radionuclides (Am-241, Co-60, H-3, and Pu-238) were used for each calculation for consistency throughout.

54 ENVIRONMENTAL SCIENCES↗

Application of GRS method to evaluation of uncertainties of calculation parameters of perspective sodium-cooled fast reactor

A number of recent studies have been devoted to the estimation of errors of reactor calculation parameters by the GRS (Generation Random Sampled) method. This method is based on direct sampling input data resulting in formation of random sets of input parameters which are used for multiple calculations. Once these calculations are performed, statistical processing of the calculation results is carried out to determine the mean value and the variance of each calculation parameter of interest. In our study this method is used for estimation of errors of calculation parameters (K{sub eff}, power density, dose rate) of a perspective sodium-cooled fast reactor. Neutron transport calculations were performed by the nodal diffusion code TRIGEX and Monte Carlo code MMK. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lattice Physics Calculations Using the Embedded Self-Shielding Method in Polaris, Part I: Methods and Implementation

Polaris is a 2-dimensional multigroup lattice physics capability in the SCALE code system for the analysis of light water reactor fuel designs. The goal of light water reactor lattice physics codes is to generate few-group homogenized cross sections for downstream full-core nodal diffusion calculations. Additionally, lattice physics calculations contain three primary components: the cross section processing calculation, the 2D transport calculation, and the depletion calculation. This paper summarizes the calculational methods and their implementation into Polaris, with an emphasis on implementation of the embedded self-shielding method. The accuracy of the embedded self-shielding method depends on the procedure used to generate self-shielding factors on the multigroup library. Numerical benchmarks calculations reveal that the accuracy of Polaris eigenvalue predictions is enhanced by (1) using heterogeneous unit cell models to generate the self-shielding factors on the library and (2) using self-shielding factors for within-group scattering cross section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A comparison of carbon calculators

International attention to carbon dioxide emissions is turning to an individual's contribution, or 'carbon footprint.' Calculators that estimate an individual's CO{sub 2} emissions have become more prevalent on the internet. Even with similar inputs, however, these calculators can generate varying results, often by as much as several metric tons per annum per individual activity. This paper examines the similarities and differences among ten US-based calculators. Overall, the calculators lack consistency, especially for estimates of CO{sub 2} emissions from household electricity consumption. In addition, most calculators lack information about their methods and estimates, which impedes comparison and validation. Although carbon calculators can promote public awareness of carbon emissions from individual behavior, this paper reveals the need for improved consistency and transparency in the calculators.

54 ENVIRONMENTAL SCIENCES↗

Image phase shift invariance based cloud motion displacement vector calculation method for ultra-short-term solar PV power forecasting

Irradiance received on the earth's surface is the main factor that affects the output power of solar PV plants, and is chiefly determined by the cloud distribution seen in a ground-based sky image at the corresponding moment in time. It is the foundation for those linear extrapolation-based ultra-short-term solar PV power forecasting approaches to obtain the cloud distribution in future sky images from the accurate calculation of cloud motion displacement vectors (CMDVs) by using historical sky images. Theoretically, the CMDV can be obtained from the coordinate of the peak pulse calculated from a Fourier phase correlation theory (FPCT) method through the frequency domain information of sky images. The peak pulse is significant and unique only when the cloud deformation between two consecutive sky images is slight enough, which is likely possible for a very short time interval (such as 1?min or shorter) with common changes in the speed of cloud. Sometimes, there will be more than one pulse with similar values when the deformation of the clouds between two consecutive sky images is comparatively obvious under fast changing cloud speeds. This would probably lead to significant errors if the CMDVs were still only obtained from the single coordinate of the peak value pulse. However, the deformation estimation of clouds between two images and its influence on FPCT-based CMDV calculations are terrifically complex and difficult because the motion of clouds is complicated to describe and model. Therefore, to improve the accuracy and reliability under these circumstances in a simple manner, an image-phase-shift-invariance (IPSI) based CMDV calculation method using FPCT is proposed for minute time scale solar power forecasting. First, multiple different CMDVs are calculated from the corresponding consecutive images pairs obtained through different synchronous rotation angles compared to the original images by using the FPCT method. Second, the final CMDV is generated from all of the calculated CMDVs through a centroid iteration strategy based on its density and distance distribution. Third, the influence of different rotation angle resolution on the final CMDV is analyzed as a means of parameter estimation. Simulations under various scenarios including both thick and thin clouds conditions indicated that the proposed IPSI-based CMDV calculation method using FPCT is more accurate and reliable than the original FPCT method, optimal flow (OF) method, and particle image velocimetry (PIV) method.

14 SOLAR ENERGY↗