Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X

The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of DIII-D radial interferometer–polarimeter for large bandwidth, low noise, and toroidal mode number measurements

Near ion-cyclotron frequency (f ci ) fluctuations, such as those originating from Global and Compressional Alfvén Eigenmodes (GAEs/CAEs), are expected to be present in future fusion reactors but are not well understood due to the limited availability of core measurements in present-day tokamaks. The measurement bandwidth of the Radial Interferometer–Polarimeter (RIP) diagnostic has been upgraded from 1 to 5 MHz to detect these fluctuations in DIII-D. RIP adopts the three-wave technique for simultaneous polarimetric and interferometric measurements. Solid-state microwave sources operating at 650 GHz are used as probe beams and provide 5 MHz bandwidth for both polarimetric and interferometric measurements. Bandwidths of related hardware, including mixer amplifier, signal cable, and digital phase demodulator, are increased correspondingly. Measurement noise is minimized by reducing the time delay between reference and probe signals to nanosecond level and employing correlation-based techniques. Using the upgraded diagnostic, CAE/GAE-like bursting fluctuations are observed in neutral-beam heated plasmas with toroidal magnetic field B φ ≈ 1 T. Current upgrades being undertaken would enable the evaluation of toroidal mode number for these modes. Furthermore, this work opens the possibility of better understanding near ion-cyclotron frequency fluctuations in fusion relevant plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a capacitance measurement for pulsed magnetic fields

Capacitance measurements are crucial for probing the electrical properties of materials. In this study, we develop and implement a capacitance measurement technique optimized for pulsed magnetic fields. Our approach employs an auto-balancing bridge method, leveraging a high-bandwidth transimpedance amplifier to mitigate parasitic contributions from coaxial cables. This technique enables precise capacitance measurements in rapidly changing magnetic fields, as demonstrated in experiments on the magnetoelectric material NiCo 2 TeO 6 . The results reveal strong magnetoelectric coupling, including a pronounced hysteresis in capacitance that coincides with magnetization measurements and an enhanced energy dissipation peak at high sweep rates. Compared to traditional LCR meter measurements in DC fields, our method exhibits excellent agreement while providing additional insight into field-induced phase transitions. This work establishes a robust methodology for capacitance measurements under extreme conditions and opens new opportunities for studying multiferroic and correlated electron systems under high magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental studies of 1.5 – 1.6 μm high-power single-frequency semiconductor lasers

High-power semiconductor laser systems based on 1.5 – 1.6 μm single-frequency distributed feedback (DFB) lasers with a sidewall Bragg diffraction grating are developed and their current – voltage, light – current, and spectral characteristics are experimentally studied. The characteristics of conventional lasers with a Fabry – Perot cavity and DFB lasers fabricated from one and the same heterostructure are compared. At a pump current not exceeding 700 mA, a conventional laser with a cavity length of 1.6 mm and a mesa-stripe width of 3 μm emits a power no lower than 200 mW versus 150 mW of the DFB laser; both lasers are mounted in a housing 11 mm in diameter. The DFB laser mounted in a butterfly housing emits a power no lower than 100 mW at the exit of the single-mode cable at a pump current not exceeding 500 mA, which, at a 60 % coupling efficiency, corresponds to a power no lower than 165 mW; the side-mode suppression ratio in this case is no lower than 53 dB. It is shown that the wavelength deviation with changing pump current and temperature is almost an order of magnitude lower for the DFB laser than for the conventional laser. (paper)

36 MATERIALS SCIENCE↗

Climate change–induced stress disrupts ectomycorrhizal interaction networks at the boreal–temperate ecotone

The interaction networks formed by ectomycorrhizal fungi (EMF) and their tree hosts, which are important to both forest recruitment and ecosystem carbon and nutrient retention, may be particularly susceptible to climate change at the boreal–temperate forest ecotone where environmental conditions are changing rapidly. Here, we quantified the compositional and functional trait responses of EMF communities and their interaction networks with two boreal ( Pinus banksiana and Betula papyrifera ) and two temperate ( Pinus strobus and Quercus macrocarpa ) hosts to a factorial combination of experimentally elevated temperatures and reduced rainfall in a long-term open-air field experiment. The study was conducted at the B4WarmED (Boreal Forest Warming at an Ecotone in Danger) experiment in Minnesota, USA, where infrared lamps and buried heating cables elevate temperatures (ambient, +3.1 °C) and rain-out shelters reduce growing season precipitation (ambient, ~30% reduction). EMF communities were characterized and interaction networks inferred from metabarcoding of fungal-colonized root tips. Warming and rainfall reduction significantly altered EMF community composition, leading to an increase in the relative abundance of EMF with contact-short distance exploration types. These compositional changes, which likely limited the capacity for mycelial connections between trees, corresponded with shifts from highly redundant EMF interaction networks under ambient conditions to less redundant (more specialized) networks. Further, the observed changes in EMF communities and interaction networks were correlated with changes in soil moisture and host photosynthesis. Collectively, these results indicate that the projected changes in climate will likely lead to significant shifts in the traits, structure, and integrity of EMF communities as well as their interaction networks in forest ecosystems at the boreal–temperate ecotone.

54 ENVIRONMENTAL SCIENCES↗

Distributed fiber-optic sensing in a subscale high-temperature superconducting dipole magnet

High-temperature superconductors, such as REBa2Cu3O7−x (REBCO, RE = rare earth), are becoming pivotal for high-field magnet technology for future circular colliders and compact fusion reactors. The U.S. Magnet Development Program, in collaboration with industry, is developing REBCO magnet technology using round conductors consisting of multiple REBCO tapes. For these multi-tape cables, traditional instrumentation, such as voltage taps and resistive strain gauges, become insufficient to help measure and understand the performance-limiting factors in these model magnets. Distributed fiber-optic sensing (DFOS) is a potential solution to address this challenge. Although DFOS is well established for various applications, measuring temperature and strain in high-temperature superconducting magnets is in its infancy. Here we report the detailed implementation and test results of DFOS based on Rayleigh scattering in a subscale canted cosθ (CCT) dipole magnet using high-temperature superconducting CORC® wires. We co-wound optical fibers in each layer of the CCT magnet and compared different types of commercial fibers and mold-release agents to reduce the power attenuation in the fibers. The DFOS allowed us to measure mechanical deformation and temperature along the conductor during tests at 77 and 4.2 K. The measured strain agreed quantitively with a finite-element mechanical model of the subscale magnet. Our results indicate that DFOS can effectively identify locations of strain and temperature changes, offering unique insight into magnet performance that can advance our understanding and development of the REBCO magnet technology for high-energy physics and fusion applications.

Luo, Linqing↗

Process-based balance of system cost modeling for offshore wind power plants in the United States

This paper describes the development of a process-based and open-source balance of system cost model that provides the capability to evaluate both existing and novel offshore wind technologies. Individual design and installation steps are represented with bottom-up engineering models that compute times and costs associated with the process; furthermore, operational constraints are assigned to each process so that delays caused by weather and presence of marine mammals may be accounted for in the overall project timeline. The model structure, assumptions, inputs, and results are vetted with industry partners and compared against actual projects for validation. Installation times show reasonable agreement with real data. Project cost sensitivities are investigated to compute the system-level impact of different design choices. First, individual vessel efficiencies are computed for varying numbers of installation vessels and weather time series to show the diminishing returns of more than two feeder barges. Then, array cable capital costs and installation times are determined for a representative project with different turbine sizes. These values quantify the cost-benefit tradeoffs and show a net-cost savings of decreasing numbers of turbines, increased turbine spacing, and fewer turbine terminations. These results demonstrate that the balance of system model features the accuracy, functionality, and accessibility to serve as the foundation for a wide range of analyses to identify cost reduction potentials for offshore wind energy in the United States.

17 WIND ENERGY↗

Neutral gas analysis for JET DT operation

Neutral gas analysis, the measurement and evaluation of total and partial pressures, is a key technique to study the impact of neutral gas dynamics on retention, recycling and release processes of fuel or impurity species in fusion devices. At JET, the experiment closest to ITER in terms of operating parameters and size, various detectors and techniques for partial pressure and total pressure measurements are deployed together to characterise neutral gas dynamics during and after plasma operation on various toroidal and poloidal locations. An extensive modification of JET's sub-divertor neutral gas diagnostic system aims at retaining and extending established measurement capabilities in the forthcoming Deuterium-Tritium (DT) experiments (DTE2). To achieve DT compatibility, a separation of radiation-sensitive electronics from the sensor and adequate radiation shielding is required, as well as utilisation of a DT compatible differential pumping system with adjustable throughput to account for the strong pressure variation in the sub-divertor region. Finally, the sub-divertor neutral gas diagnostic will be equipped with multiple Residual Gas Analysers (RGAs), utilising quadrupole mass spectrometry and electrostatic ion-trap-principles, all operating with remote electronics located behind the biological radiation shield. These RGAs will record data in a fast selected discrete mass mode during plasma pulses (cycle ~2 s) and will automatically switch back to continuous data recording (cycle ~100 s) afterwards. They will be complemented by a newly improved Penning gauge spectroscopy configuration in particular supporting the He and D 2 separation relevant for DT operation. The distance between these devices and their associated control unit is typically 15m . A newly developed RGA with a cable length of 80 m, compatible with the ITER environment, will also be employed for the first time. Finally, this set-up and its operation in DTE2 will provide vital input to the development of the ITER divertor RGA in the most relevant environment currently available.

47 OTHER INSTRUMENTATION↗

Lycoris - A large-area, high resolution beam telescope

We note that a high-resolution beam telescope is one of the most important and demanding infrastructure components at any test beam facility. Its main purpose is to provide reference particle tracks from the incoming test beam particles to the test beam users, which allows measurement of the performance of the device-under-test (DUT). LYCORIS, a six-plane compact beam telescope with an active area of ~ 10 x 10 cm 2 (extensible to 10 x 20 cm 2 ) was installed at the DESY II Test Beam Facility in 2019, to provide a precise momentum measurement in a 1 T solenoid magnet or to provide tracking over a large area. The overall design of Lycoris will be described as well as the performance of the chosen silicon sensor. The 25 μm pitch micro-strip sensor used for Lycoris was originally designed for the SiD detector concept for the International Linear Collider. It adopts a second metallization layer to route signals from strips to the bump-bonded KPiX ASIC and uses a wire-bonded flex cable for the connection to the DAQ and the power supply system. This arrangement eliminates the need for a dedicated hybrid PCB. Its performance was tested for the first time in this project. The system has been evaluated at the DESY II Test Beam Facility in several test-beam campaigns and has demonstrated an average single-point resolution of 7.07 μm.

47 OTHER INSTRUMENTATION↗

Fast wave interferometer for ion density measurement on DIII-D

=A fast wave interferometer (FWI), which can measure ion mass density, has been developed on DIII-D for its use on future fusion reactors, as well as for the study of ion behavior in current plasma devices. The frequency of the fast waves used for the FWI is around 60 MHz, and require antennas and coaxial cables or waveguides, which, unlike traditional mirror-based optical interferometers, are less susceptible to neutron/gamma-ray radiation and are relatively immune to impurity deposition and erosion as well as alignment issues. The bulk ion density evaluated using FWI show good agreement with that derived from CO 2 interferometry within about 15%. When the ion mass density measurement by FWI is combined with an electron density measurement from CO 2 interferometry, Z eff measurements are also enabled and are in agreement with those from visible Bremsstrahlung measurements. Additionally, large-bandwidth FWI measurements clearly resolve 10–100 kHz coherent modes and demonstrate its potential as a core fluctuation diagnostic, sensitive to both magnetic and ion density perturbations.

Instruments & Instrumentation↗

The Octopus processor for the CMS L1 muon trigger for High Luminosity LHC

The upgraded L1 muon trigger system of the CMS experiment in the High Luminosity Large Hadron Collider is based on custom processors featuring large Field Programmable Gate Arrays (FPGAs) connected by large numbers of optical links. These provide the I/O bandwidth and power necessary to process the complex algorithms used during the collection of physics data. The design and performance requirements of these processors creates significant challenges in signal integrity, power delivery, and thermal management. In this paper we describe the Octopus processor, featuring a large Xilinx Virtex Ultrascale+ FPGA and up to 128 links interfaced to optics through high quality twin-ax copper cables. Results on signal integrity at 25 Gb/s and the first demonstration of 50+ Gb/s links with pluggable optics in CMS are also shown, demonstrating bit error rates below 10 –15 at a 95% confidence level. The thermal performance is measured inside an Advanced-TCA crate with acceptable thermal margins up to 200 W of chip power. Future improvements are mentioned, potentially allowing operation at up to 300 W.

Instruments & Instrumentation↗

Upgrades of the ATLAS zero degree calorimeter system for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1, were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with H_2-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; a new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new “Reaction Plane Detectors” (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run 3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run 3.

43 PARTICLE ACCELERATORS↗

Operational experience with the Proto-DUNE NP02 and NP04 large volume liquid argon cryostats and their cryogenic systems at CERN

The far Detector of the Deep Underground Neutrino Experiment (DUNE) will be housed in several large volume (about 12.500 m$^{3}$) liquid argon cryostats. The design principle of these large cryostats, and of the cryogenic system belonging to them, are investigated through the design, construction and operation of a series of prototype installations.The Neutrino Platform 02 (NP02) and 04 (NP04) cryostats, placed at CERN, contain DUNE proto-type detectors, each of them housed in an about 600 m$^{3}$ liquid argon bath. These cryostats, based on the membrane cryostat principle, and their cryogenic systems have been designed according to the DUNE principle. Measurements performed in these test stands shall confirm the foreseen heat loads into the cryostat systems entering via its walls, via detector cabling and via the cold electronics, shall confirm the low temperature gradient over the active detector volume and shall certify the liquid argon purification principle.This paper introduces the requirements for the NP02 and NP04 cryostats and their cryogenic systems, describes the design principle applied to these two systems and gives an overview of the different modes in which the two systems have been operating. The experimental results are presented and discussed, and “lessons learned” for future installations are dawn.

43 PARTICLE ACCELERATORS↗

Measurement of Transverse Resistance for Stacks of Non-insulated REBCO Tapes

Transverse resistance among adjacent conductors is a key parameter to calculate AC losses in superconducting cables with non-insulated conductors. The transverse pressure insert (TPI) previously developed and used at Fermilab was modified to measure transverse resistance of stacks made of non-insulated REBCO tapes as a function of transverse pressure at liquid nitrogen temperature. Pressure up to 322 MPa was applied with a hydraulic cylinder. A small current up to 10 A was flown in the stack sample through REBCO tape leads spliced above and below the stack. The latter had a bending radius larger than 6 mm to prevent the critical current degradation in REBCO leads. The voltage was measured just outside the compressed area. Stack samples included stacks of bare 4-mm wide REBCO tapes, as well as REBCO tapes alternated with 4-mm wide stainless-steel ribbons of 40 μm and 30 μm of thickness. We herein present the results of these transverse resistance measurements. Results show a stronger dependence on pressure for smaller pressure vs. larger ones. Also, of the two components of contact resistance, i.e. contact and bulk, the latter was negligible.

Tamagnini, E. [Turin Polytechnic]↗

Phase-weighted slant stacking for surface wave dispersion measurement

SUMMARY Surface wave retrieval from ambient noise records using seismic interferometry techniques has been widely used for multiscale shear wave velocity (Vs) imaging. One key step during Vs imaging is the generation of dispersion spectra and the extraction of a reliable dispersion curve from the retrieved surface waves. However, the sparse array geometry usually affects the ability for high-frequency (>1 Hz) seismic signals’ acquisition. Dispersion measurements are degraded by array response due to sparse sampling and often present smeared dispersion spectra with sidelobe artefacts. Previous studies usually focus on interferograms’ domain (e.g. cross-correlation function) and attempt to enhance coherent signals before dispersion measurement. We propose an alternative technique to explicitly deblur dispersion spectra through use of a phase-weighted slant-stacking algorithm. Numerical examples demonstrate the strength of the proposed technique to attenuate array responses as well as incoherent noise. Three different field examples prove the flexibility and superiority of the proposed technique: the first data set consists of ambient noise records acquired using a nodal seismometer array; the second data set utilizes distributed acoustic sensing (DAS) and a marine fibre-optic cable to acquire a similar ambient noise data set; the last data set is a vibrator-based active-source surface wave data. The enhanced dispersion measurements provide cleaner and higher-resolution spectra without distortions which will assist both human interpreters as well as ML algorithms in efficiently picking curves for subsequent Vs inversion.

58 GEOSCIENCES↗

Phase-controlled improvement of photon lifetime in coupled superconducting cavities

High-quality cavities are crucial for various fundamental physical studies and applications. Here we find that by coupling two cavities directly or via a phase-tunable coupling channel, the photon lifetime of the local field can exceed that of the bare cavities. The cavity photon lifetime is modified by the phases of the initial states and the phase accumulation on the coupling channel, which affect the interference between cavities. In experiments, by coupling superconducting radio-frequency cavities via phase-tunable cables, we realize a factor of 2 improvement in the cavity photon lifetime. The results can bring rich revenue to quantum information science, sensing, and high-energy physics.

43 PARTICLE ACCELERATORS↗

Modular Quantum Processor with an All-to-All Reconfigurable Router

Superconducting qubits provide a promising approach to large-scale fault-tolerant quantum computing. However, qubit connectivity on a planar surface is typically restricted to only a few neighboring qubits. Achieving longer-range and more flexible connectivity, which is particularly appealing in light of recent developments in error-correcting codes, however, usually involves complex multilayer packaging and external cabling, which is resource intensive and can impose fidelity limitations. Here, we propose and realize a high-speed on-chip quantum processor that supports reconfigurable all-to-all coupling with a large on-off ratio. We implement the design in a four-node quantum processor, built with a modular design comprising a wiring substrate coupled to two separate qubit-bearing substrates, each including two single-qubit nodes. We use this device to demonstrate reconfigurable controlled-𝑍 gates across all qubit pairs, with a benchmarked average fidelity of 96.00% ± 0.08% and best fidelity of 97.14% ± 0.07%, limited mainly by dephasing in the qubits. We also generate multiqubit entanglement, distributed across the separate modules, demonstrating GHZ-3 and GHZ-4 states with fidelities of 88.15% ± 0.24% and 75.18% ± 0.11%, respectively. This approach promises efficient scaling to larger-scale quantum circuits and offers a pathway for implementing quantum algorithms and error-correction schemes that benefit from enhanced qubit connectivity.

Quantum circuits↗

Flexible positioning of a large area detector using an industrial robot

The DIAD beamline for Dual Imaging and Diffraction at Diamond Light Source has opted to use an industrial robot to position its Dectris Pilatus 2M CdTe diffraction detector. This setup was chosen to enable flexible positioning of the detector in a quarter-sphere around the sample position whilst reliably holding the large weight of 139 kg of detector, detector mount and cabling in a stable position. Metrology measurements showed that the detector can be positioned with a linear repeatability of <19.7 µm and a rotational repeatability of <16.3 µrad. The detector position stays stable for a 12 h period with <10.1 µm of movement for linear displacement and <3.8 µrad for rotational displacement. X-ray diffraction from calibration samples confirmed that the robot is sufficiently stable to resolve lattice d-spacings within the instrumental broadening given by detector position and beam divergence.

36 MATERIALS SCIENCE↗