Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “builders”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Deterministic Design of High Precision Slicing Machine Final Report CRADA No. T-160-91-1-C (Advanced manufacturing initiative final report. Deterministic design of high precision slicing machine)

The project is designed to merge the expertise of LLNL and a US slicing machine builder in the development and production of a family of ultra-precise, slicing/grinding machines. The project will lead to the joint development of a modular family of slicers which are easily configured to a given accuracy and size. The slicers can then be profitably produced and marketed for similar precision machining applications. This project is directed towards maintaining a competitive edge for US manufacturers in the area of high precision slicing and grinding machines.

36 MATERIALS SCIENCE↗

The MARS Code System User’s Guide Version 15(2016)

This paper is a user’s guide to the current version of the MARS15 Monte Carlo code. MARS allows inclusive and, in many cases, exclusive simulations of three-dimensional hadronic and electromagnetic cascades and modeling of heavy ion, muon and low energy neutron-photon transport in accelerator, detector, spacecraft and shielding components. Particles can have energies from a fraction of an electronvolt up to about 100 TeV. The code has undergone substantial improvements since the last documented version MARS13(95) and since previous releases of MARS15; all these as well as other specific features of the MARS code system are explained in detail. Descriptions of general input and output with commentary and recommendations are given. Examples are given for running the program with distributed sources, complex compounds, arbitrary geometries, and magnetic fields. A built-in graphical-user interface allows the visualization and detailed analysis of the geometry description. Enhanced options are described for the MARS code being coupled with: the DPMJET hadron event generator, the MCNP code for low-energy neutron transport, the ANSYS system for thermal and stress analysis, physics analysis and graphics packages, the MAD accelerator lattice description via a universal MAD-MARS beam line builder, the STRUCT program for tracking particles in accelerator lattices with beam loss recording, the DETRA code for nuclide decay and transmutation calculations, the EGS5 code for precise modeling of low-energy electromagnetic showers, and the ROOT system for description and visualization of arbitrary geometries. Use of the code in a multistage mode, coupled with event generators (DPMJET), with the STRUCT program for tracking particles in accelerator lattices with beam loss recording, and with physics analysis and graphics packages is demonstrated with typical input and output examples.

43 PARTICLE ACCELERATORS↗

Residential Slab Component Calculations

Modern residential building energy codes provide a component tradeoff mechanism by which builders can trade reductions in the efficiency of some building components in trade for corresponding improvement in other components. One common tradeoff approach is based on maintaining a building "UA value," which represents the building envelope's overall thermal conductance. The building UA is the sum of individual component UA values, each of which is calculated as the product of the component's U-factor and area. Current codes, however, provide little guidance on including slab-on-grade components in the overall UA calculation. This brief provides information on calculating effective slab UA values and provides recommended text for building codes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Supporting Simulation Families in Nuclear Reactor Workflows SBIR Phase I. Final Scientific/Technical Report

The US Department of Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) Toolkit has accelerated both the solutions to existing problems and deployment of new designs for current and advanced reactors. Within the toolkit, there exist various families of simulation tools that target specific aspects of a multi-physics simulation for a nuclear reactor. Tools within a specific family vary in both complexity and fidelity as well as the types of resources they require. To complement the NEAMS effort, the Computational Model Builder (CMB) has been designed to provide a graphical user interface to design and execute nuclear reactor workflows. Previously, we had designed a workflow in CMB to design and prepare for execution a neutronics simulation using DIF3D, a diffusion and transport solver developed at Argonne National Laboratory. For this Phase I effort, we extended CMB’s reactor modeling tools to design and execute a workflow using Proteus-SN, a higher-fidelity transport solver developed at Argonne with more preparatory requirements from the workflow. Furthermore, this workflow was designed to maximize the common features of the two workflows, describing the analogous tasks between the workflows as belonging to a “simulation family”. This perspective facilitates the abstraction of the neutronics simulations to a single bifurcated workflow, allowing the engineer to design a reactor and then choose the appropriate simulation according to his or her needs for fidelity and computational cost.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Field Validation of High-R Windows: Market Assessment and Program Plan

This report provides a market assessment for high-performance residential windows based on information gathered from key researchers and industry stakeholders including a series of interviews conducted with high-performance builders in 2019. The report also outlines the U.S. Department of Energy’s planned field validation activities in support of high-R windows and provides the basis for planned field validation approaches. Although the report may be of general interest to those who work in fields pertaining to building energy efficiency and/or market adoption of energy-efficiency measures, the primary intent of this report is to document market characteristics, barriers, and activities related to high-performance residential windows in order to assist with internal program planning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

Unvented roof assemblies have been accepted in North American building codes since 2007; code-compliant construction calls for a minimum thickness of “air-impermeable insulation” (based on climate zone) to avoid cold-weather condensation and moisture risks. This is typically implemented with polyurethane spray foam insulation; however, negatives of this material include high first cost and possible adverse environmental impacts. Implementing unvented roofs in a moisture-safe manner with air-permeable fibrous fill insulations (e.g., fiberglass or cellulose) could potentially reduce the first cost of unvented roof designs, allowing for more widespread use. Building unvented roofs in a cost-effective, airtight, and moisture-safe manner opens up options for high-performance house designers and builders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guidance and Recommendations for Streamlining Reporting for Federal Energy and Water Efficiency Projects

Federal agencies are required to report on their progress in meeting various energy and water management requirements. These reporting requirements encompass energy and water projects at federal facilities, including projects that are alternatively financed, e.g., conducted through energy savings performance contracts (ESPCs) or utility energy service contracts (UESCs). The purpose of this guidance is to provide recommendations to streamline federal agency reporting. The guidance recommends the use of eProject Builder (ePB), a project development and archiving tool for energy projects. ePB carries additional value in its simplification of federal agency reporting by dovetailing with the Federal Energy Management Program’s (FEMP’s) EISA 432 Compliance Tracking System (CTS).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MOOSE Framework Meshing Enhancements to Support Reactor Analysis

MOOSE-based physics codes require an input finite element mesh on which the physics solution is calculated, reported, and transferred to other physics codes. The use of difficult-touse, external licensed software is often required to generate high quality meshes for reactor geometries. High-fidelity geometry modeling also requires elaborate tracking of groups of elements for material property assignment and output reporting which can be considerably complex for the user to identify and maintain. Under the U.S. Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, several meshingrelated enhancements have been developed for the MOOSE framework to address user challenges in creating finite element meshes for advanced reactor geometries. MOOSE mesh generators have been developed to mesh hexagonal geometries (pins, ducted assemblies, and cores) commonly found in liquid-metal cooled fast reactor concepts. The mesh generator used for hexagonal pin cells is generic for regular polygons and therefore may also be used for Cartesian pin cells. Hexagonal pin cells can be stitched into ducted assemblies, and assemblies can be stitched together into a core. The user may specify region ids, region names, and other preferences on the mesh. This control is useful for later material mapping in the MOOSE-based physics codes input. A capability was also developed for meshing rotating control drums including determination of material volume fractions in each mesh element as a function of time. Control drum meshes may be stitched to other hexagonal assemblies to create a core configuration. Additional mesh generators were developed that wrap around the hexagonal meshing capabilities and utilize “extra element integer” ID values on each element. In regular Cartesian or hexagonal assemblies or cores, the bookkeeping of element groups for both material assignment and output reporting can now be automated through assignment of pin, assembly, core, axial and depletion id values stored as extra element integers. The extra element tags on the mesh greatly speed the reactor analyst’s efforts to map materials to meshes, track depletion zones, and parse output such as axial pin power distributions. At the highest level, pin, assembly, and core mesh generators (with this reactor terminology) have also been developed to easily generate regular Cartesian and hexagonal cores, including axial extrusion. These reactor geometry builders call upon the previously mentioned capabilities to produce analysis-ready 3D meshes including material assignments. Open source mesh triangulation capabilities were also investigated for integration into the MOOSE framework to address the need for meshing the core periphery region which extends from the irregular outer assembly border to a cylindrical boundary. Options are limited due to licensing constraints, and the recommendation is pursue building a native MOOSE Delaunay triangulator routine with full functionality. Finally, a series of verification problems were performed with NEAMS physics tools. All developed capabilities will be available in the new open-source “Reactor” module of the MOOSE framework, which is accessible to any MOOSE-based NEAMS physics tool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it's desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilation systems (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. While this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and - of greatest concern - outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger HVAC systems. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Mitsubishi Electric Trane US, CORE Energy Recovery Solutions, and Therma-Stor LLC to design and test VICS prototypes. A conceptual diagram is shown in Figure 1, and the latest prototype (shown in Figure 2) was manufactured by Therma-Stor and tested in SWA's facility in Norwalk, CT. The ERV heat exchanger was provided by CORE, and the VICS was installed in conjunction with a 1-ton, inverter heat pump provided by Mitsubishi.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Affordable Solid Panel "Perfect Wall" System

The SPS is an innovative interpretation of the “perfect wall” concept, in which environmental control layers are located on the exterior side of the structural components, as opposed to traditional cavity insulated, stud-framed walls. The primary objective of this study is to validate the SPS technology in terms of its constructability, cost, and performance. Specifically for this project, we partnered with two affordable housing nonprofits in Minnesota—Twin Cities Habitat for Humanity and Urban Homeworks—to build five new houses using SPS walls, as well as two high-performance stud-framed comparison homes. We also reviewed cost and performance data from 13 SPS homes built prior to this project by MonoPath and Spero Environmental Builders. Reviewing the outcomes of these 20 homes total, we find promising results in terms of constructability, cost, and performance, although more structural performance data are needed before this new technology can see widespread adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the New Home Market Opportunity: Case Study and Cost Modeling for Solar and Storage in 2030

Residential solar and storage markets are growing in the United States. With approximately 1 million new homes constructed every year, this represents a significant opportunity for solar and storage installations. Some homebuilders have begun to build new homes with solar and storage included as a standard offering. It is not clear how solar and storage is incorporated into the new construction process and at what cost. Further, it is unclear what barriers or opportunities exist to scale this model nationwide. To fill this gap in the literature, this research conducts a case study of Mandalay Homes' new solar and storage community in Arizona to gather lessons learned. From this foundation, we further generate a set of pathways to reduce install costs and expand solar and storage market penetration in this sector. To model existing and 2030 solar and storage costs, we use the National Renewable Energy Laboratory's (NREL's) bottom-up cost model. This modeling is further informed by 12 interviews conducted with new home builders, solar contractors, and other subject matter expert organizations. Our case study analysis generated three key considerations for other homebuilders including: 1. Educating local permitting, inspection, and in some cases utility officials on solar and storage products, designs, and code compliant building practices may be required. The need for education may decline as more local governments and utilities review and approve solar and storage projects. 2. Incorporating solar and storage systems into the homebuilding process can add complexity and related coordination challenges. This does not need to result in home construction delays, but can result in costly contractor "dry runs" to construction sites. 3. Deploying solar and storage at the time of new construction has significant economies of scale, which can improve the value proposition of the systems. The case study, extant literature, and interviews were used to model both existing and future solar and storage installation costs at time of new construction. Here, we find three key cost reduction opportunities relating to solar and battery storage hardware, customer acquisition, and overhead. If future contractors can maximize the cost reduction opportunities outlined here, residential new construction costs could decline by 8 - 25% by 2030, depending on the modeled scenario. Though we expect costs to decline through 2030, it is unclear which of these scenarios may ultimately appear. Interviewees further identified a variety of barriers across each cost category that could temper the savings shown here. At the same time, interviewees described several pathways to scale the new construction solar and storage market, beyond installation cost savings. Interviewees confirmed that changes in finance, rate design, resilience policies, deployment mandates, and DER aggregation could all support more market adoption than seen today. These findings suggest that there are significant opportunities to expand new construction markets and this research can serve as a baseline to assess progress in this segment through 2030.

14 SOLAR ENERGY↗

The Energy in Modular (EMOD) Buildings Method: A Guide to Energy-Efficient Design for Industrialized Construction of Modular Buildings

Industrialized construction has immense potential to address the growing need globally to build and upgrade the building stock to be affordable, energy-efficient, and resilient. It can also help achieve the United States' goal of a 50% reduction in U.S. greenhouse gas (GHG) emissions by 2030. Despite this potential, and the ever-increasing push for electrification and decarbonization of households in the United States, industrialized construction has not yet been leveraged specifically to help address these challenges and accelerate the pathway to meet these goals. The National Renewable Energy Laboratory (NREL) aims to claim this missed opportunity by focusing on delivering affordable, grid-efficient net-zero energy (NZE) modular buildings for underserved communities to ensure an equitable transition to the future of clean energy, accelerate decarbonization of the built environment, and support the development of a high-productivity construction and energy efficiency workforce. The Energy in Modular (EMOD) method is our approach to designing, producing, and delivering affordable, net-zero energy, low-carbon, and healthier buildings at scale. The following energy efficiency strategies are part of the scope of this guide: envelope thermal control, envelope infiltration control, mechanical, electrical, and plumbing systems, smart controls, and solar plus storage. We draw synergies between design for manufacturing and assembly, process optimization, retrofit technologies, and digitization. Our goal is to influence the improvement and production of buildings to increase performance, enhance energy efficiency, and reduce GHG emissions. This guide documents the research and development efforts initiated by a set of design objectives to "modularize" a set of energy efficiency and low-carbon strategies into a housing unit while preserving and enhancing energy efficiency benefits and decarbonization pathways. This guide is intended to serve as a framework for housing developers, housing agencies, architects, energy experts, and process engineers or factory operator personnel who are critical to today's modular builder teams. This guide focuses on specific energy efficiency strategies, decarbonization pathways, and associated processes as part of NREL's research efforts. Stakeholders may substitute other means, methods, and technologies for the ones evaluated in this study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SULI Technical Report: WIRE (Draft)

Local climate undoubtedly affects facility maintenance requirements; however, knowledge of the link between weather and facility condition over time is grounded in the 1990s and needs to be updated. WIRE aims to quantify the relationship between climate and infrastructure by calculating climate-based service life estimates to be used in BUILDER, a program the Department of Energy (DOE) uses for facility management. Phase One of this project is a case study on window-or-wall-mounted AC units. The independent variables influencing service life are load, maintenance quality, and effective age, with load calculated from three weather variables: temperature, humidity, and solar radiation. Given sufficient data, service life can be calculated as a function of these variables via regression. WIRE is currently collecting data. Preliminary estimated service life projections as a function of load derived from Lawrence Livermore National Laboratory (LLNL) data support the need for updated analysis on the relationship between climate and facility condition. With the groundwork laid, WIRE can generate deliverables immediately upon arrival of data. The methods used for this case study constitute a framework for deriving the relationship between weather variables and service life for other components.

42 ENGINEERING↗

MOOSE Reactor Module Meshing Enhancements to Support Reactor Physics Analysis

The U.S. Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) program develops an integrated suite of advanced reactor physics tools built upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Each code generally requires an input finite element mesh on which the physics solution is calculated, reported, and transferred to other physics codes. The meshing process is often burdensome for the complex geometries present in reactors due to lack of easy-to-use, open-source meshing tools. To address the bottleneck associated with meshing complex geometries found in nuclear reactors, NEAMS initiated the development of the MOOSE Reactor Module starting in FY21. The Reactor Module builds off the existing MOOSE Mesh System to include targeted meshing capabilities such as the ability to generate hexagonal pin cells, assemblies with ducts, rotating control drums, cores, peripheral zones around a core, as well as the automatic labeling (“reporting IDs”) of pin, assembly, and planar zones to simplify post-processing of results. As a Physics Module in MOOSE, the Reactor Module is open-source, available with any MOOSE installation, directly compatible with MOOSE-based tools, and can be invoked from MOOSEbased applications to generate meshes. Functionality from the Reactor Module has been applied to several advanced reactor concepts to demonstrate user workflow improvements and accuracy. The primary objective of the Reactor Module is to improve useability of MOOSEbased tools by streamlining mesh generation and output inspection processes. During FY22, the functionality of the Reactor Module (and accompanying Mesh System) has been expanded based on user needs. First, the Reactor Geometry Mesh Builder capability developed primarily in FY21 has been refactored and merged to the public MOOSE repository. This capability wraps underlying Reactor Module mesh generators into a “Pin – Assembly – Core” workflow appropriate for conventional Cartesian and hexagonal geometries, and notably assigns material IDs during mesh generation stage and generates only the minimal number of blocks needed in order to reduce computational burden. Biasing and boundary layer options have been added to the base mesh generators as required by thermal hydraulics solvers. The reporting ID functionality has been expanded to differentiate ring-wise and azimuthal sectors within a pin for use with depletion algorithms, and VectorPostProcessor and Reporter objects are now available to integrate solution variables across zones based on ID combinations. Functionality to trim hexagonal meshes along the center or periphery has been developed so users may leverage symmetry and reflective boundary conditions to reduce the mesh size. A flexible and powerful tool to fill the space between two sidesets has been introduced to the framework and can be used for transition layers such as stitching two assemblies together with different numbers of pins, or for complex geometries which do not follow conventional Cartesian/hexagonal patterns. Finally, additional verification problems were performed with NEAMS physics tools in complement with existing NEAMS work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of the Thermal and Moisture Performance of Insulating Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak heating and cooling loads of a home. Over the past 20 years, residential window attachment retrofit technologies have been developed that significantly increase the number of options available to home builders, homeowners, and utilities when considering upgrades of overall window performance. Within the interior window attachments category, honeycomb cellular shades typically have the highest R-values because of their layered or concentric designs. During the winter when the window is fully covered, however, the added insulation reduces the amount of warm indoor air that reaches the window surface, thereby lowering the temperature of the window glass and frame and increasing the potential for condensation to collect on the interior surface of the window. The degree to which this potential is realized depends on the indoor and outdoor conditions as well as the overall thermal resistance of the window and the shades. To examine the condensation buildup potential on the interior surface of the window and the conditions under which this occurs, this report describes experimental research conducted by Pacific Northwest National Laboratory in collaboration with Hunter Douglas, using a a controlled environmental test chamber at the Hunter Douglas facility in Broomfield, Colorado. The results will be used to inform the Attachments Energy Rating Council, which provides energy performance information on all rated window attachments products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗