Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biomedical device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

SU-F-T-462: Lessons Learned From a Machine Incident Reporting System

Purpose: Linear accelerators must operate with minimal downtime. Machine incident logs are a crucial tool to meet this requirement. They providing a history of service and demonstrate whether a fix is working. This study investigates the information content of a large department linear accelerator incident log. Methods: Our department uses an electronic reporting system to provide immediate information to both key department staff and the field service department. This study examines reports for five linac logs during 2015. The report attributes for analysis include frequency, level of documentation, who solved the problem, and type of fix used. Results: Of the reports, 36% were documented as resolved. In another 25% the resolution allowed treatment to proceed although the reported problem recurred within days. In 5% only intermediate troubleshooting was documented. The remainder lacked documentation. In 60% of the reports, radiation therapists resolved the problem, often by clearing the appropriate faults or reinitializing a software or hardware service. 22% were resolved by physics and 10% by field service engineers. The remaining 8% were resolved by IT, Facilities, or resolved spontaneously. Typical fixes, in order of scope, included clearing the fault and moving on, closing and re-opening the patient session or software, cycling power to a sub-unit, recalibrating a device (e.g., optical surface imaging), and calling in Field Service (usually resolving the problem through maintenance or component replacement). Conclusion: The reports with undocumented resolution represent a missed opportunity for learning. Frequency of who resolves a problem scales with the proximity of the person’s role (therapist, physicist, or service engineer), which is inversely related to the permanence of the resolution. Review of lessons learned from machine incident logs can form the basis for guidance to radiation therapists and medical physicists to minimize equipment downtime and ensure safe operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Use of a Trellis Device for Endovascular Treatment of Venous Thrombosis Involving a Duplicated Inferior Vena Cava

Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot involving the infrarenal segment of a duplicated left IVC who underwent pharmacomechanical thrombectomy and tissue plasminogen activator catheter-directed thrombolysis with complete deep venous thrombosis resolution. To our knowledge this is the first reported case in the English literature of the use of a Trellis thrombectomy catheter in the setting of duplicated IVC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robust surfactant-assisted one-pot sample preparation for label-free single-cell and nanoscale proteomics

With advanced mass spectrometry (MS)-based proteomics, genome-scale proteome coverage can be achieved from bulk cells. However, such bulk measurement obscures cell to cell heterogeneity, precluding proteome profiling of single cells and small numbers of cells of interest. To address this issue, in recent 5 years there are a surge of small sample preparation methods developed for robust effective collection and processing of single cells and small numbers of cells for in-depth MS-based proteome profiling. Based on their broad accessibility, they can be categorized into two types: specific device- and standard PCR tube- or multi-well plate-based methods. Herein we describe the detailed protocol of our recently developed, easily adoptable, Surfactant-assisted One-Pot (SOP) sample preparation coupled with MS method termed SOP-MS for label-free single-cell and nanoscale proteomics. SOP-MS capitalizes on the combination of a MS-compatible surfactant, DDM (n-Dodecyl-ß-D-maltoside), and standard low-bind PCR tube or multi-well plate for ‘all-in-one’ one-pot sample preparation without sample transfer. With its robust and convenient features, SOP-MS can be readily implemented in any MS laboratory for single-cell and nanoscale proteomics. With further improvements in MS detection sensitivity and sample throughput, we believe that SOP-MS could open an avenue for single-cell proteomics with broad applicability in the biological and biomedical research.

Single-cell proteomics, nanoscale proteomics, SOP-↗

Thermoplastic moulding of regenerated silk

Early insights into the unique structure and properties of native silk suggested that β-sheet nanocrystallites in silk would degrade prior to melting when subjected to thermal processing. Since then, canonical approaches for fabricating silk-based materials typically involve solution-derived processing methods, which have inherent limitations with respect to silk protein solubility and stability in solution, and time and cost efficiency. In this study, we report a thermal processing method for the direct solid-state moulding of regenerated silk into bulk ‘parts’ or devices with tunable mechanical properties. At elevated temperature and pressure, regenerated amorphous silk nanomaterials with ultralow β-sheet content undergo thermal fusion via molecular rearrangement and self-assembly assisted by bound water to form a robust bulk material that retains biocompatibility, degradability and machinability. This technique reverses presumptions about the limitations of direct thermal processing of silk into a wide range of new material formats and composite materials with tailored properties and functionalities.

36 MATERIALS SCIENCE↗

A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography

Since coronary heart disease is one of the main causes of death all over the world, cardiac computed tomography (CT) imaging is an application of very high interest in order to verify indications timely. Due to the cardiac motion, electrocardiogram (ECG) gating has to be implemented into the reconstruction of the measured projection data. However, the temporal and spatial resolution is limited due to the mechanical movement of the gantry and due to the fact that a finite angular span of projections has to be acquired for the reconstruction of each voxel. In this article, a motion-compensated reconstruction method for cardiac CT is described, which can be used to increase the signal-to-noise ratio or to suppress motion blurring. Alternatively, it can be translated into an improvement of the temporal and spatial resolution. It can be applied to the entire heart in common and to high contrast objects moving with the heart in particular, such as calcified plaques or devices like stents. The method is based on three subsequent steps: As a first step, the projection data acquired in low pitch helical acquisition mode together with the ECG are reconstructed at multiple phase points. As a second step, the motion-vector field is calculated from the reconstructed images in relation to the image in a reference phase. Finally, a motion-compensated reconstruction is carried out for the reference phase using those projections, which cover the cardiac phases for which the motion-vector field has been determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strain-insensitive intrinsically stretchable transistors and circuits

An all-elastomer strain engineering approach, which uses patterned elastomer layers with tunable stiffnesses, can be used to create intrinsically stretchable transistor arrays with a device density of 340 transistors cm -2 and strain insensitivity of less than 5% performance variation when stretched to 100% strain. Intrinsically stretchable electronics can form intimate interfaces with the human body, creating devices that could be used to monitor physiological signals without constraining movement. However, mechanical strain invariably leads to the degradation of the electronic properties of the devices. Here we show that strain-insensitive intrinsically stretchable transistor arrays can be created using an all-elastomer strain engineering approach, in which the patterned elastomer layers with tunable stiffnesses are incorporated into the transistor structure. By varying the cross-linking density of the elastomers, areas of increased local stiffness are introduced, reducing strain on the active regions of the devices. This approach can be readily incorporated into existing fabrication processes, and we use it to create arrays with a device density of 340 transistors cm -2 and a strain insensitivity of less than 5% performance variation when stretched to 100% strain. We also show that it can be used to fabricate strain-insensitive circuit elements, including NOR gates, ring oscillators and high-gain amplifiers for the stable monitoring of electrophysiological signals.

42 ENGINEERING↗

The Imaging and Medical Beam Line at the Australian Synchrotron

As a result of the enthusiastic support from the Australian biomedical, medical and clinical communities, the Australian Synchrotron is constructing a world-class facility for medical research, the 'Imaging and Medical Beamline'. The IMBL began phased commissioning in late 2008 and is scheduled to commence the first clinical research programs with patients in 2011. It will provide unrivalled x-ray facilities for imaging and radiotherapy for a wide range of research applications in diseases, treatments and understanding of physiological processes. The main clinical research drivers are currently high resolution and sensitivity cardiac and breast imaging, cell tracking applied to regenerative and stem cell medicine and cancer therapies. The beam line has a maximum source to sample distance of 136 m and will deliver a 60 cm by 4 cm x-ray beam1 - monochromatic and white - to a three storey satellite building fully equipped for pre-clinical and clinical research. Currently operating with a 1.4 Tesla multi-pole wiggler, it will upgrade to a 4.2 Tesla device which requires the ability to handle up to 21 kW of x-ray power at any point along the beam line. The applications envisaged for this facility include imaging thick objects encompassing materials, humans and animals. Imaging can be performed in the range 15-150 keV. Radiotherapy research typically requires energies between 30 and 120 keV, for both monochromatic and broad beam.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Colossal Terahertz Emission with Ultrafast Tunability Based on Van der Waals Ferroelectric NbOI 2

Abstract Terahertz (THz) technology is critical for quantum material physics, biomedical imaging, ultrafast electronics, and next‐generation wireless communications. However, standing in the way of widespread applications is the scarcity of efficient ultrafast THz sources with on‐demand fast modulation and easy on‐chip integration capability. Here the discovery of colossal THz emission is reported from a van der Waals (vdW) ferroelectric semiconductor NbOI 2 . Using THz emission spectroscopy, a THz generation efficiency an order of magnitude higher than that of ZnTe, a standard nonlinear crystal for ultrafast THz generation is observed. The underlying generation mechanisms associated are further uncovered with its large ferroelectric polarization by studying the THz emission dependence on excitation wavelength, incident polarization, and fluence. Moreover, the ultrafast coherent amplification and annihilation of the THz emission and associated coherent phonon oscillations by employing a double‐pump scheme are demonstrated. These findings combined with first‐principles calculations, inform a new understanding of the THz light–matter interaction in emergent vdW ferroelectrics and pave the way to develop high‐performance THz devices on them for quantum materials sensing and ultrafast electronics.

Subedi, Sujan [Department of Materials Science and↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

Soft inertial microfluidics for high throughput separation of bacteria from human blood cells

We developed a new approach to separate bacteria from human blood cells based on soft inertial force induced migration with flow defined curved and focused sample flow inside a microfluidic device. This approach relies on a combination of an asymmetrical sheath flow and proper channel geometry to generate a soft inertial force on the sample fluid in the curved and focused sample flow segment to deflect larger particles away while the smaller ones are kept on or near the original flow streamline. The curved and focused sample flow and inertial effect were visualized and verified using a fluorescent dye primed in the device. First the particle behavior was studied in detail using 9.9 and 1.0 {micro}m particles with a polymer-based prototype. The prototype device is compact with an active size of 3 mm{sup 2}. The soft inertial effect and deflection distance were proportional to the fluid Reynolds number (Re) and particle Reynolds number (Re{sub p}), respectively. We successfully demonstrated separation of bacteria (Escherichia coli) from human red blood cells at high cell concentrations (above 10{sup 8}/mL), using a sample flow rate of up to 18 {micro}L/min. This resulted in at least a 300-fold enrichment of bacteria at a wide range of flow rates with a controlled flow spreading. The separated cells were proven to be viable. Proteins from fractions before and after cell separation were analyzed by gel electrophoresis and staining to verify the removal of red blood cell proteins from the bacterial cell fraction. This novel microfluidic process is robust, reproducible, simple to perform, and has a high throughput compared to other cell sorting systems. Microfluidic systems based on these principles could easily be manufactured for clinical laboratory and biomedical applications.

54 ENVIRONMENTAL SCIENCES↗

Mortality and Rates of Secondary Intervention After EVAR in an Unselected Population: Influence of Simple Clinical Categories and Implications for Surveillance

IntroductionPost-EVAR surveillance has a major impact upon patients, carers and healthcare resources. We hypothesised that elective indication, on-IFU anatomy, use of a modern device or normal first CTA, or a combination of these categories, might predict a rate of secondary intervention low enough to alter current surveillance protocols.MethodsPatients undergoing EVAR in our institution between 01.05.2007 and 28.02.2013 were assessed. Data on indication (elective, emergency), anatomy relative to IFU, device, first month CTA result, secondary intervention and mortality were obtained. Kaplan–Meier charts of mortality and freedom from secondary intervention were produced. Statistical analysis was by log-rank test and Cox proportional hazard modelling.Results234 patients underwent EVAR (188 elective, 208 on-IFU). Most implants were Endurant (106) or Talent (98). 151 patients had a normal first CTA. By median follow-up of 38.6 months, 39 patients underwent secondary intervention. A normal first CTA and elective indication were significantly associated with reduced risk of secondary intervention (p < 0.001 and p = 0.042 respectively), but device type and placement on- or off-IFU were not. Elective placement with a normal first CTA was 93 % predictive of freedom from secondary intervention by 32 months post-EVAR. Of nine patients undergoing secondary intervention in this group, eight presented symptomatically.DiscussionIn optimal procedural circumstances with normal post-procedural imaging, only 7 % of patients undergoing EVAR require secondary intervention, a minority of which is driven by surveillance. These data support a change to surveillance more tailored to the individual patient, and highlight the need for further qualitative and quantitative research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Project 57 Air Monitoring Report: (Jan 1 - Dec 31 2018)

During the late 1950s, the Atomic Energy Commission (AEC) (now the U.S. Department of Energy [DOE]) conducted a series of safety experiments to determine if a nuclear device subjected to a large conventional explosives detonation would result in a nuclear yield. The AEC obtained temporary use of a large portion of western Emigrant Valley from the U.S. Department of Defense (DOD) for one of these experiments: Project 57. Following the Project 57 safety experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Emigrant Valley is part of the Nevada Test and Training Range (NTTR). For safety and security reasons, access to the NTTR is controlled using both physical (i.e., fences) and administrative (e.g., signs and postings) controls. Therefore, the public cannot access the Project 57 site and there are no known human receptors that routinely access the site. Project 57 was detonated on April 24, 1957, in Emigrant Valley approximately 13 mi (21 km) northeast of the north end of Yucca Flat. This test was undertaken to develop: (1) a means of estimating immediate distribution and long-term redistribution of plutonium dispersed during a nonnuclear detonation; (2) biomedical evaluation techniques for use in likely plutonium-laden environments; (3) methods of decontaminating ground areas, pavements, and building materials; and (4) alpha survey instruments and field monitoring procedures to promptly estimate contaminant deposition. Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the ground surface. Various radiological surveys have been performed in the area since Project 57 was conducted. The AEC delineated the area containing radioactive material based on radioactivity surveys performed shortly after the test was conducted. A designated Contamination Area (CA), marked by a fence, was established later. The distribution of americium-241 (Am-241) in the area was determined again in a 1997 flyover, which showed Am-241 ranging from as much as 70,000 counts per second (cps) at ground zero to background (<70 cps). This survey also documented Am-241 radioactivity on the ground surface beyond the east side CA fence at levels of up to 150 cps. In 2007, the DOE expanded the CA by posting “Contamination Area” signs 200 ft to 400 ft (60 m to 120 m) beyond the original fence, which formed a new CA boundary.

54 ENVIRONMENTAL SCIENCES↗

SU-F-T-493: An Investigation Into the Feasibility of Using PipsPro Software with Film for Linac QA

Purpose: To determine the feasibility of using radiochromic and radiographic film with Pipspro software for quality assurance of linear accelerators with no on-board imaging. Methods: The linear accelerator being used is a Varian Clinac 21EX. All IGRT is performed using the BrainLab ExacTrac system. Because of the lack of on board imaging, certain monthly and annual TG-142 quality assurance tests are more difficult to perform and analyze to a high degree of accuracy. Pipspro was not designed to be used with hard film, and to our knowledge its use with film had not been investigated. The film used will be GafChromic EBT3 film and Kodak EDR2 film, scanned with an Epson V700 scanner. The following routine tests will be attempted: MLC picket fence, light vs. radiation field coincidence, starshots, and MLC transmission. Results: The only tests that gave accurate and reliable results were the couch, gantry, and collimator starshots. Typical MV and kV images are acquired with a much higher level of contrast between the irradiated and non-irradiated areas when compared to film. Pipspro relies on this level of contrast to be able to automatically detect the fiducial points from its phantom devices, leaf edges for picket fence and transmission tests, and jaw edges for light vs. radiation field tests. Because of this, certain tests gave erroneous results and others were not able to be performed in the software at all, with either type of film. The number of monitor units delivered to the film, the experimental setup, and the scan settings was not able to rectify the problem. Conclusion: For linear accelerators with no on-board imaging, it is not recommended to use hard film with PipsPro to perform TG-142 quality assurance tests. Other software or methods should instead be investigated.

60 APPLIED LIFE SCIENCES↗

3D printable silicone compositions exhibiting high toughness and low durometer

3D printable silicones can be designed with varying crosslink density, network structures, and types of reinforcing additives. Within this design space, one may tailor the uncured material’s rheology and mechanical response to access a wide range of potential applications. However, printable, low modulus silicones, particularly those applicable to direct ink write, are underreported in published literature. To address the need for higher performance, low modulus silicones with demonstrated printability, a new set of ca. 20–50 Shore A hardness silicone elastomers exhibiting ca. 7 MPa ultimate tensile strength and ca. 400–1200% elongation at break is presented. Mechanical properties were analyzed, providing insight to the effects of formulation constituents on mechanical properties. Cyclic mechanical testing of the silicone formulations was also performed, and the energy loss and permanent set throughout cycling were determined. In conclusion, printed structures demonstrate the feasibility of these new silicones as durable frameworks for novel soft device applications.

36 MATERIALS SCIENCE↗

A three channel telemetry system

A three channel telemetry system intended for biomedical applications is described. The transmitter is implemented in a single chip using a 2 micron BiCMOS processes. The operation of the system and the test results from the latest chip are discussed. One channel is always dedicated to temperature measurement while the other two channels are generic. The generic channels carry information from transducers that are interfaced to the system through on-chip general purpose operational amplifiers. The generic channels have different bandwidths: one from dc to 250 Hz and the other from dc to 1300 Hz. Each generic channel modulates a current controlled oscillator to produce a frequency modulated signal. The two frequency modulated signals are summed and used to amplitude modulate the temperature signal which acts as a carrier. A near-field inductive link telemeters the combined signals over a short distance. The chip operates on a supply voltage anywhere from 2.5 to 3.6 Volts and draws less than 1 mA when transmitting a signal. The chip can be incorporated into ingestible, implantable and other configurations. The device can free the patient from tethered data collection systems and reduces the possibility of infection from subcutaneous leads. Data telemetry can increase patient comfort leading to a greater acceptance of monitoring.

Lesho, Jeffery C.↗

Does Mechanical Thrombectomy in Acute Embolic Stroke Have Long-term Side Effects on Intracranial Vessels? An Angiographic Follow-up Study

Purpose. Mechanical thrombectomy (mTE) proved to be effective treating acute vessel occlusions with an acceptable rate of procedural complications. Potential long-term side effects of the vessel wall trauma caused by mechanical irritation of the endothelium are unknown up to now. Methods. From a retrospectively established database of 640 acute stroke treatments, we selected 261 patients with 265 embolic vessel occlusions treated successfully by mTE without permanent implantation of a stent. Analysis comprised the type of devices used and the number of passes performed. Digital subtraction angiography immediately after treatment was evaluated for vasospasm, dissection, and extravasation. Control angiographic images were evaluated for any morphological change compared to the immediate posttreatment angiographic run. Results. Recanalization was achieved with a median of one (range 1-10) mTE maneuvers. Vasospasm occurred in 69 territories (26.0 %) and was treated with glyceroltrinitrate in three. Dissection was observed in one vessel (0.4 %). Intraprocedural hemorrhage in two patients (0.8 %) was either wire or device induced. Follow-up digital subtraction angiography was available for 117 territories after a median of 107 days, revealing target vessel occlusion in one segment (0.9 %) and a de novo stenosis of four segments (3.4 %). All findings were clinically asymptomatic. Posttreatment vasospasm was more frequent in patients with de novo stenosis and occlusion (p = 0.038). Conclusion. De novo stenoses and occlusions occur in a small proportion of patients after mTE. Because all lesions were clinically asymptomatic, this finding does not affect the overall benefit of the treatment. Vasospasm may predict late vessel wall changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformable Organic Nanowire Field-Effect Transistors

Deformable electronic devices that are impervious to mechanical influence when mounted on surfaces of dynamically changing soft matters have great potential for next–generation implantable bioelectronic devices. Here, deformable field–effect transistors (FETs) composed of single organic nanowires (NWs) as the semiconductor are presented. The NWs are composed of fused thiophene diketopyrrolopyrrole based polymer semiconductor and high–molecular–weight polyethylene oxide as both the molecular binder and deformability enhancer. The obtained transistors show high field–effect mobility >8 cm 2 V –1 s –1 with poly(vinylidenefluoride– co –trifluoroethylene) polymer dielectric and can easily be deformed by applied strains (both 100% tensile and compressive strains). The electrical reliability and mechanical durability of the NWs can be significantly enhanced by forming serpentine–like structures of the NWs. Remarkably, the fully deformable NW FETs withstand 3D volume changes (>1700% and reverting back to original state) of a rubber balloon with constant current output, on the surface of which it is attached. In conclusion, the deformable transistors can robustly operate without noticeable degradation on a mechanically dynamic soft matter surface, e.g., a pulsating balloon (pulse rate: 40 min –1 (0.67 Hz) and 40% volume expansion) that mimics a beating heart, which underscores its potential for future biomedical applications.

36 MATERIALS SCIENCE↗

Nanoporous aluminum oxide membranes coated with atomic layer deposition-grown titanium dioxide for biomedical applications: An in vitro evaluation

The surface topographies of nanoporous anodic aluminum oxide (AAO) and titanium dioxide (TiO 2 ) membranes have been shown to modulate cell response in orthopedic and skin wound repair applications. In this study, we: (1) demonstrate an improved atomic layer deposition (ALD) method for coating the porous structures of 20, 100, and 200 nm pore diameter AAO with nanometer-thick layers of TiO 2 and (2) evaluate the effects of uncoated AAO and TiO 2 -coated AAO on cellular responses. The TiO 2 coatings were deposited on the AAO membranes without compromising the openings of the nanoscale pores. The 20 nm TiO 2 -coated membranes showed the highest amount of initial protein adsorption via the micro bicinchoninic acid (micro-BOA) assay; all of the TiO 2 -coated membranes showed slightly higher protein adsorption than the uncoated control materials. Cell viability, proliferation, and inflammatory responses on the TiO 2 -coated AAO membranes showed no adverse outcomes. For all of the tested surfaces, normal increases in proliferation (DNA content) of L929 fibroblasts were observed over from 4 hours to 72 hours. No increases in TNF-alpha production were seen in RAW 264.7 macrophages grown on TiO 2 -coated AAO membranes compared to uncoated AAO membranes and tissue culture polystyrene (TOPS) surfaces. Both uncoated AAO membranes and TiO 2 -coated AAO membranes showed no significant effects on cell growth and inflammatory responses. In conclusion, the results suggest that TiO 2 -coated AAO may serve as a reasonable prototype material for the development of nanostructured wound repair devices and orthopedic implants.

36 MATERIALS SCIENCE↗