Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arrival time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

472 records · Page 27

Association of Mesoscale Auroral Structures and Breakups With Energetic Particle Injections at Geosynchronous Orbit

Geomagnetic substorms are associated with characteristic energetic particle injection signatures at geosynchronous orbit that are often dispersionless in both electrons and ions near the magnetic local time sector of auroral onset locations and are dispersed farther away from this region. Although the precise mechanism responsible for the coherent injection signatures at geosynchronous orbit have been the topic on considerable ongoing debate for decades, recent work on bursty bulk flows (BBFs) in the tail have led to the hypothesis that they may be the result of multiple, overlapping flow bursts penetrating into the inner magnetosphere from more distant downtail reconnection sites. Since auroral streamers are thought to be ionospheric signatures of BBFs in the tail, they can be used as proxies for testing this hypothesis. Using high resolution auroral imagery from the POLAR/VIS instrument combined with multi-spacecraft observations of energetic particle injections at geosynchronous orbit, we examine the association of mesoscale auroral structures with particle injection signatures over many hours during the 9 November 1998 storm. We find that the explosive types of auroral activations, such as pseudo-breakups and substorm onset breakups, are associated with the more intense and well-defined dispersed injection signatures, while intervals of isolated streamer activity appear to be associated with smaller dispersed “injectionlet” signatures. Furthermore, intervals of sustained, intense, and late expansion phase/recovery phase streamer activity appear to be associated with sustained elevated dispersed particle fluxes. These results are consistent with the hypothesis that it is the overlapping effects of sustained, intense multiple flow bursts penetrating toward the Earth that result in classical substorm particle injection signatures at geosynchronous orbit. However, it is also suggested that torches/omega-band tongues are the prime fate of braking isolated flow bursts (streamers) rather than the development of breakups, bulges, and substorm current wedge formation. A statistical analysis is presented showing that 93% of the observed torches evolved from streamers, 93% of streamers arriving in the equatorward regions of the bulge led to torches, 10.5% of such streamers led to breakups (either pseudo-breakups or substorm onsets), and only 3.5% of such streamers led to substorm onsets.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of a generalized least squares algorithm for infrasound beamforming with coherent background noise

Infrasonic signals of interest can occur during periods with persistent, coherent, background noise, which may be natural or anthropogenic. For high signal-to-noise (SNR) ratio transient signals, an ‘overprinting’ of the coherent background may occur, and the signal may still be detected. However, this approach fails for low SNR signals of interest, which may be obscured by coherent noise. An infrasound beamforming method based on generalized least squares (GLS) is investigated for detecting transient signals of interest in the presence of coherent and incoherent background noise. This approach relies on an estimate of the noise covariance, captured in a covariance matrix, to effectively null contributions to the array response from noisy directions of arrival. Synthetic array data is used to investigate the performance of the GLS beamformer compared to the Bartlett beamformer when coherent and incoherent backgrounds are present. Additionally, the effects of array element number and relative strength of the interfering signal on the GLS estimates is investigated. GLS empirical area under the curve estimates suggest that the beamformer can recover coherent power for a signal of interest lower in amplitude than the coherent background, but this effectiveness degrades more quickly with SNR for a four element array compared to a six or eight element infrasound array. Finally, infrasound from the Forensic Surface Experiment, a bolide signal observed at IMS array I37NO, and a volcanic signal recorded at the Alaska Volcano Observatory array ADKI are used to evaluate GLS performance on recorded data. A ten minute window was used to capture the background noise, and the coherent background signal was nulled in all three examples.

58 GEOSCIENCES↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

The Influence of Aqueous Dispersivity on Transport of Radiological Material at LANL MDA G - 20450

Aqueous dispersivity is a phenomenon by which a solute moving in groundwater mixes with water that does not contain the solute and becomes diluted. Solutes take paths of varying lengths through pore networks or experience slower velocities due to interactions with pore walls. Aqueous dispersivity leads to breakthrough curves with earlier arrival than expected in purely advective systems and persistent 'tails,' or late-arriving, dilute concentrations of the solute. Dispersivity can be longitudinal (in the direction of flow) or transverse (orthogonal to flow). LANL has disposed of radioactive material at Material Disposal Area (MDA) G since the late 1950's. Most of the disposed materials at MDA G are low-level waste (LLW), but other types of radioactive wastes are disposed or stored at the site. For example, there is a collection of remote-handled transuranic waste (RH-TRU) waste in 33 shafts, which were intended to be stored retrievably. Aqueous-phase radionuclides included in models of contaminant transport at MDA G are subject to dispersive processes in porous media of the vadose zone and saturated zone. To model dispersivity at MDA G probabilistically, we created site-specific distributions of aqueous dispersivity. First, we performed a comprehensive review of peer-reviewed publications, reports from other performance assessments of MDA G, and documentation from sites that were considered similar based on expert opinion, such as Yucca Mountain. Data were included from a wide range of sources, so that distributions developed based on the data reflect the current state of knowledge in properties of the subsurface environment. Data were grouped based on value type (e.g., determined via experiment or used in a different model), rock type, zone type (saturated or unsaturated), and site, and were weighted in the distributions according to their relevance to the site and zone type. We combined Monte Carlo simulation and bootstrapping techniques to produce approximate distributions of mean aqueous dispersivity. Distributions of dispersivity for saturated and unsaturated zone transport are differentiated by data weight and the length scales over which transport occurs. We find that underestimating or disregarding transverse dispersivity may lead to overstating simulated well capture in the saturated zone at MDA G. Neglecting transverse dispersivity is a common assumption due in part to use of one-dimensional transport models that do not consider solute spreading orthogonal to flow. Also, we find that variability in longitudinal dispersivity is associated with substantial travel time alterations in the MDA G unsaturated zone and in simulated contaminant breakthrough times at a downstream observation plane in the MDA G saturated zone. Finally, at large scales (>1000 m), a linear trend between the dispersivity coefficient and length over which transport occurs may overestimate the dispersivity coefficient. Future modeling work with application to solute spreading could include interacting advective and diffusive zones in the highly fractured basalt below MDA G. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗