Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerated beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

An ultrafast laser pulse picker technique for high-average-current high-brightness photoinjectors

Beam diagnostics in high brightness photoinjectors requires that optical pulses from a high-power drive laser be picked up with an ultrahigh pulse contrast ratio and without temporal profile distortion. In high-average-current high-brightness photoinjectors, high-power drive lasers are routinely operated at GHz-level pulse repetition rate and it is challenging to achieve pulse picking without any pulse distortion. Here, we report on a new ultrafast pulse picker technique for beam diagnostics in high-average-current high-brightness photoinjectors. By efficiently combining an ultrafast low-power electro-optic modulator, high-power fiber laser amplifiers, a high-power Pockels Cell, and a frequency doubling module, we have successfully demonstrated optical bunch (30 pulses per bunch) pickup from a 704 MHz high-power drive laser and achieved a 10 6 :1 pulse contrast ratio and nearly zero pulse distortion. The performance of this pulse picking technique has been verified through beam characterization and electron cooling in the low energy RHIC electron cooling accelerator at Brookhaven National Laboratory.

43 PARTICLE ACCELERATORS↗

Field Measurement Results of the 15 T Nb 3 Sn Dipole Demonstrator MDPCT1b

A 15 T Nb 3 Sn dipole with cos-theta-type coils was developed to demonstrate a possible magnet design for a post-LHC proton-proton Collider. The magnet has 4-layer coils with 60-mm aperture, and has graded current density between the inner and outer layers to maximize performance. The coils are constrained by vertically-split, thick iron laminations, connected by aluminum Iclamps, and a thick stainless-steel skin. The magnet was previously tested at the Vertical Magnet Test Facility (VMTF) at Fermilab with reduced pre-load, and achieved record 14.1 T fields at maximum current. Now the magnet has been reassembled with full pre-load and has been cryogenically retested at VMTF. We report here on the magnetic measurements results of these tests, including field strength, geometrical harmonics, coil magnetization, and iron saturation characteristics of the demonstrator.

43 PARTICLE ACCELERATORS↗

The BDX experiment at Jefferson Laboratory

The Beam Dump Experiment (BDX) at Jefferson Laboratory (JLab) is an electron-beam thick-target experiment to search for Light Dark Matter (LDM) particles in the MeV-GeV mass range. BDX will exploit the high-intensity 10.6 GeV e^-e ? beam from CEBAF accelerator impinging on the beam dump of experimental Hall-A, collecting up to 10^{22}10 22 electrons-on-target (EOT) in a few years time. Any LDM particle produced by the interaction of the primary e^-e ? beam with the beam dump will be detected by measuring their scattering inside the BDX detector, an electromagnetic calorimeter surrounded by an hermetic veto system, which is to be installed in a dedicated underground facility, located 20 m downstream. Thanks to the large detection efficiency and background rejection capabilities, BDX will be able to explore a so-far unknown region in the LDM parameter space, improving current exclusion limits by one order of magnitude in case of a null observation. In preparation to the full experiment, a small-scale version called BDX-MINI, has been built and operated at JLab with a lower energy beam. Despite the small interaction volume, the large accumulated charge of 2.2\times10^{21}2.2×10 21 EOT allowed for the BDX-MINI measurement to set competitive exclusion limits on the LDM parameters space, comparable to those reported by larger-scale efforts.

Celentano, A.↗

Perspectives on the generation of electron beams from plasma-based accelerators and their near and long term applications

This article first gives the authors' perspectives on how the field of plasma-based acceleration (PBA) developed and how the current experiments, theory, and simulations are motivated by long term applications of PBA to a future linear collider and an x-ray free electron laser. Here, we then focus on some early applications that will likely emerge from PBA research such as electron beam radiotherapy, directional but incoherent x-ray beams for science and technology, near single cycle continuously tunable infrared pulses for spectroscopy, and non-perturbative quantum electrodynamics enabled by PBA electron beams. In our opinion, these near term applications could be developed within the next decade with a concerted effort by the community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Artificial stimulation of auroral electron acceleration by intense field aligned currents

A cesium-doped high explosion was detonated at 165 km altitude in the auroral ionosphere during quiet conditions. An Alfven wave pulse with a 200-mV/m electric field was observed, with the peak occurring 135 ms after the explosion at a distance of about 1 km. The count rate of fixed energy 2-keV electron detectors abruptly increased at 140 ms, peaked at 415 ms, and indicated a downward field-aligned beam of accelerated electrons. An anomalously high-field aligned beam of backscattered electrons was also detected. The acceleration is interpreted as due to production of an electrostatic shock or double layer between 300 and 800 km altitude. The structure was probably formed by an instability of the intense field-aligned currents in the Alfven wave launched by the charge-separation electric field due to the explosion.

Holmgren, G.↗

Rotating field mass and velocity analyzer

A rotating field mass and velocity analyzer having a cell with four walls, time dependent RF potentials that are applied to each wall, and a detector. The time dependent RF potentials create an RF field in the cell which effectively rotates within the cell. An ion beam is accelerated into the cell and the rotating RF field disperses the incident ion beam according to the mass-to-charge (m/e) ratio and velocity distribution present in the ion beam. The ions of the beam either collide with the ion detector or deflect away from the ion detector, depending on the m/e, RF amplitude, and RF frequency. The detector counts the incident ions to determine the m/e and velocity distribution in the ion beam.

Smith, Steven Joel↗

Accelerator commissioning and rare isotope identification at the Facility for Rare Isotope Beams

In 2008, Michigan State University was selected to establish the Facility for Rare Isotope Beams (FRIB). Construction of the FRIB accelerator was completed in January 2022. Phased accelerator commissioning with heavy ion beams started in 2017 with the normal-conducting ion source and radio-frequency quadrupole. In April 2021, the full FRIB driver linear accelerator (linac) was commissioned, with heavy ion beams accelerated to energies above 200 MeV/nucleon by 324 superconducting radiofrequency (SRF) resonators operating at 2 K and 4 K with liquid-helium cooling. Further, in preparation for high-power operation, a liquid lithium charge stripper was commissioned with heavy ion beams up to uranium-238, followed by the simultaneous acceleration of multiple-charge-state heavy ion beams to energies above 200 MeV/nucleon. In December 2021, selenium-84 was produced with the FRIB target using a krypton-86 primary beam, demonstrating FRIB’s capability for scientific discovery.

07 ISOTOPE AND RADIATION SOURCES↗

A development of wide dynamic-range halo monitor for 8 GeV proton beams at FNAL

The FNAL accelerator complex has been upgrading in increasing beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between booster and Recycler. For this purpose, it was decided to introduce the wide dynamic range monitor technique that was developed in 2012 and has been in operation at the J-PARC beam transport line. The device is a two-dimensional beam profile monitor, and it has a dynamic range of approximately six digits of magnitude by using of Optical Transition Radiation and fluorescence screens. Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. New FNAL device has been manufactured in a collaboration between J-PARC and FNAL as a part of U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. The equipment will be manufactured at J-PARC and will be shipped to FNAL in 2025.We designed the device to satisfy FNAL specifications: the beam energy, intensity, and size. Currently, most of the equipments are under construction. The large-aperture optical system has been completed and its optical characteristics are being evaluated at J-PARC. We have been also investigating measurement methods corresponding to FNAL bunch trains. This paper reports on the current status of these developments.

43 PARTICLE ACCELERATORS↗

Wire scanner assessment of transverse beam size in the Fermilab side-coupled linac

The Fermilab Side-Coupled Linac contains seven 805 MHz modules accelerating H- beam from 116 MeV to 400 MeV. Each module contains at least one wire scanner, yielding beam intensity at positions along a transverse direction. These wire scanners each contain three wires, mounted at different angles: "X", "Y", and 45° between "X" and "Y" to analyze coupling. Recently, a significant amount of transverse X-Y coupling was identified within wire scanner data from the Side-Coupled Linac, which has been present in data from the past decade. This realization has prompted an investigation into the wire scanner's utility as a diagnostic tool in the Fermilab Linac. This work presents efforts to better characterize the wire scanners' limitations and the phenomenon occurring in the Side-Coupled Linac.

43 PARTICLE ACCELERATORS↗

Wire Scanner Assessment of Transverse Beam Size in the Fermilab Side-Coupled Linac

The Fermilab Side-Coupled Linac contains seven 805 MHz modules accelerating H- beam from 116 MeV to 400 MeV. Each module contains at least one wire scanner, yielding beam intensity at positions along a transverse direction. These wire scanners each contain three wires, mounted at different angles: "X", "Y", and 45° between "X" and "Y" to analyze coupling. Recently, a significant amount of transverse X-Y coupling was identified within wire scanner data from the Side-Coupled Linac, which has been present in data from the past decade. This realization has prompted an investigation into the wire scanner's utility as a diagnostic tool in the Fermilab Linac. This work presents efforts to better characterize the wire scanners' limitations and the phenomenon occurring in the Side-Coupled Linac.

43 PARTICLE ACCELERATORS↗

Generation of straight and curved hollow plasma channels by laser-generated nonlinear wakefields and studies of ultra-intense laser pulse guiding

We report on a study of highly controllable, quasi-static hollow plasma channels generated by ion motion following a laser–plasma interaction via numerical simulations. These channels are generated by ion motion in a nonlinear wakefield, which has an asymmetry between focusing and defocusing periods. Such plasma channels, driven by a fs duration, 100 TW level laser pulse, have the capability to guide more powerful laser pulses. Moreover, we show that curved plasma channels can be generated in a transverse density gradient plasma and alloptical guiding of a second, significantly more powerful laser pulse in such a curved plasma channel. This mechanism may be useful for creating plasma optics for multi-stage TeV laser plasma accelerators and compact synchrotron radiation sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nb3Sn Coating of Twin Axis Cavity for SRF Applications

The twin axis cavity with two identical accelerating beams has been proposed for Energy recovery linac (ERL) applications. Nb3Sn is a superconducting material with a higher critical temperature and a higher critical field as compared to Nb, which promises a lower operating cost due to higher quality factors. Two niobium twin axis cavities fabricated at JLab and were proposed to be coated with Nb3Sn. Due to their more complex geometry, the typical coating process used for basic elliptical cavities needs to be improved to coat these cavities. This devel-opment advances the current coating system at JLab for coating complex cavities. Two twin axis cavities were coated recently for the first time. This contribution dis-cusses initial results from coating of twin axis cavities, RF testing and witness sample analysis with an overview of the current challenges towards high performance Nb3Sn coated twin axis cavities.

Tiskumara, J.↗

Implementation of a Mesh refinement algorithm into the quasi-static PIC code QuickPIC

Plasma-based acceleration (PBA) has emerged as a promising candidate for the accelerator technology used to build a future linear collider and/or an advanced light source. In PBA, a trailing or witness particle beam is accelerated in the plasma wave wakefield (WF) created by a laser or particle beam driver. The WF is often nonlinear and involves the crossing of plasma particle trajectories in real space and thus particle-in-cell methods are used. The distance over which the drive beam evolves is several orders of magnitude larger than the wake wavelength. This large disparity in length scales is amenable to the quasi-static approach. Three-dimensional (3D), quasi-static (QS), particle-in-cell (PIC) codes, e.g., QuickPIC, have been shown to provide high fidelity simulation capability with 2-4 orders of magnitude speedup over 3D fully explicit PIC codes. In PBA, the witness beam needs to be matched to the focusing forces of the WF to reduce the emittance growth. In some linear collider designs, the matched spot size of the witness beam can be 2 to 3 orders of magnitude smaller than the spot size (and wavelength) of the wakefield. Such an additional disparity in length scales is ideal for mesh refinement where the WF within the witness beam is described on a finer mesh than the rest of the WF. A mesh refinement scheme is described that has been implemented into the 3D QS PIC code, QuickPIC. Very fine (high) resolution is used in a small spatial region that includes the witness beam and progressively coarser resolutions in the rest of the simulation domain. A fast multigrid Poisson solver has been implemented for the field solve on the refined meshes and a Fast Fourier Transform (FFT) based Poisson solver is used for the coarse mesh. The code has been parallelized with both MPI and OpenMP, and the parallel scalability has also been improved by using pipelining. A preliminary adaptive mesh refinement technique is described to optimize the computational time for simulations with an evolving witness beam size. Several test problems are used to verify that the mesh refinement algorithm provides accurate results. Additionally, the results are benchmarked against highly resolved simulations exhibiting near-azimuthal symmetry, performed using QPAD—a novel hybrid QS PIC code that uses a PIC description in the coordinates (r, ct – z) and a gridless description in the azimuthal angle, Φ.

Linear collider↗

Linear beam stability in periodic focusing systems: Krein signature and band structure

The general question of how a beam becomes unstable has been one of the fundamental research topics among beam and accelerator physicists for several decades. In this study, we revisited the general problem of linear beam stability in periodic focusing systems by applying the concepts of Krein signature and band structure. We numerically calculated the eigenvalues and other associated characteristics of one-period maps, and discussed the stability properties of single-particle motions with skew quadrupoles and envelope perturbations in high-intensity beams on an equal footing. In particular, an application of the Krein theory to envelope instability analysis was newly attempted in this study. Finally, the appearance of instabilities is interpreted as the result of the collision between eigenmodes of opposite Krein signatures and the formation of a band gap.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗