Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume of fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Small Signal Modeling and Control of the Hydrogen Mixer for Facility E1

We have undertaken the theoretical modelling of an existing liquid hydrogen (LH2) and gas hydrogen (GH2) mixer subsystem of the E1 Ground Test Facility at NASA John C. Stennis Space Center. The E1 test facility carries out comprehensive ground-based testing and certification of various liquid rocket engines and their components. The mixer described in this work is responsible for combining high pressure before it is fed into a test article. The desired properties are maintained by precise control of the mixture of LH2 and GH2 flows. The mixer is modelled as a general multi-flow lumped volume for single constituent fluids using density and internal energy as states. The set of nonlinear differential equations is linearized about an equilibrium point and the resulting two-state, 3-input linear model is analyzed as a possible candidate for control design.

Barbieri, Enrique↗

Permeable Surface Corrections for Ffowcs Williams and Hawkings Integrals

The acoustic prediction methodology discussed herein applies an acoustic analogy to calculate the sound generated by sources in an aerodynamic simulation. Sound is propagated from the computed flow field by integrating the Ffowcs Williams and Hawkings equation on a suitable control surface. Previous research suggests that, for some applications, the integration surface must be placed away from the solid surface to incorporate source contributions from within the flow volume. As such, the fluid mechanisms in the input flow field that contribute to the far-field noise are accounted for by their mathematical projection as a distribution of source terms on a permeable surface. The passage of nonacoustic disturbances through such an integration surface can result in significant error in an acoustic calculation. A correction for the error is derived in the frequency domain using a frozen gust assumption. The correction is found to work reasonably well in several test cases where the error is a small fraction of the actual radiated noise. However, satisfactory agreement has not been obtained between noise predictions using the solution from a three-dimensional, detached-eddy simulation of flow over a cylinder.

Lockard, David P.↗

Water Flow Simulation using Smoothed Particle Hydrodynamics (SPH)

Simulation of water flow from the rainbird nozzles has been accomplished using the Smoothed Particle Hydrodynamics (SPH). The advantage of using SPH is that no meshing is required, thus the grid quality is no longer an issue and accuracy can be improved.

Hydrodynamics↗

EcAMSat: Effect of Space-Flight on Antibiotic Resistance of a Pathogenic Bacterium and its Genetic Basis

Human immune response is compromised in space and incidence of urinary tract infections (UTI) in astronauts has been reported. We have found that the causative agent of UTI, the uropathogenic Escherichia coli, becomes more resistant to gentamicin (Gm), which is commonly used to treat this disease, under modeled microgravity conditions (MMG), the increase being controlled by the stress response master regulator, σs. While the wild type bacterium becomes virtually invincible under MMG, the strain missing this sigma factor barely survives. We report here preparatory ground work for testing this finding in space flight on a nanosatellite. We have shown that the effect of Gm treatment on culture viability is directly correlated to increased Alamar Blue (AB) reduction; we have identified conditions to keep the experimental elements - the bacterial cultures, Gm, and AB - in a state of viability and potency to permit successful spaceflight experimentation given the necessary constraints. Spaceflight kinetics of AB reduction will be transmitted from the satellite via telemetry. The PharmaSat hardware previously used for space experimentation with yeast was modified to permit studies with bacteria by reducing the filter pore size and increasing fluidics volume to enable more fluid exchanges. Several verification tests have been run using the nanosatellite's flight software and prototype hardware. Cells were grown to stationary phase to induce the σs-controlled stress resistance and treated with Gm. Without Gm, the mutant took longer than the wild type to reduce the AB; this time difference increased almost 8 fold at 55 μg/mL Gm concentration. Thus, using flight hardware the mutant shows similarly increased sensitivity to Gm compared to the wild type to that found in our pilot microtiter plate experiments. Previous inflight experiments have given contradictory results concerning bacterial antibiotic resistance; none has yet explored the involvement of specific genes in this phenomenon. With our system ready to fly in late 2015/early 2016, these questions can be approached

uropathogenic E. coli↗

Hybrid Thermal Control System for Extreme Thermal Environments

NASA’s return to the moon brings about many challenges, including issues with survival on the Lunar surface. Marshall Space Flight Center (MSFC) has been developing a hybrid thermal control system that can be utilized for various surface assets that must survive in extreme lunar environments. This scalable system is targeted for human-rated systems and utilizes a combination of a- pumped fluid loop (PFL) and a loop heat pipe (LHP) with thermal control valve (TCV). Pumped fluid loops have a long history of use in human rated systems. They can collect large amounts of waste heat and transport it over long distances in rovers, habitats, and other systems. By utilizing a non-toxic working fluid in the habitable volume, the PFL is easily serviceable by the crew and does not pose a risk during any unexpected leaks or failures. The addition of a LHP for the exterior heat transport and rejection adds several benefits to the system for extreme environment survival. The quantity of LHP scan be tailored to optimize heat rejection for different systems and allows for larger adiative surfaces. By utilizing a TCV in combination with the LHP, there can be high heat transfer during the daytime with minimal heat transfer during the night. The TCV passively controls the amount of heat transfer through the LHP based on the environmental temperature. A prototype system has been tested in bench top and thermal vacuum conditions. Results are presented showing the feasibility of the system concept.

Thermal Control↗

Hybrid Thermal Control System for Extreme Thermal Environments

NASA’s return to the moon brings about many challenges, including issues with survival on the Lunar surface. Marshall Space Flight Center (MSFC) has been developing a hybrid thermal control system that can be utilized for various surface assets that must survive in extreme lunar environments. This scalable system is targeted for human-rated systems and utilizes a combination of a- pumped fluid loop (PFL) and a loop heat pipe (LHP) with thermal control valve (TCV). Pumped fluid loops have a long history of use in human rated systems. They can collect large amounts of waste heat and transport it over long distances in rovers, habitats, and other systems. By utilizing a non-toxic working fluid in the habitable volume, the PFL is easily serviceable by the crew and does not pose a risk during any unexpected leaks or failures. The addition of a LHP for the exterior heat transport and rejection adds several benefits to the system for extreme environment survival. The quantity of LHP scan be tailored to optimize heat rejection for different systems and allows for larger adiative surfaces. By utilizing a TCV in combination with the LHP, there can be high heat transfer during the daytime with minimal heat transfer during the night. The TCV passively controls the amount of heat transfer through the LHP based on the environmental temperature. A prototype system has been tested in bench top and thermal vacuum conditions. Results are presented showing the feasibility of the system concept.

Thermal Control↗

A CFD Analysis of Hydrogen Leakage During On-Pad Purge in the ORION/ARES I Shared Volume

A common open volume is created by the stacking of the Orion vehicle onto the Ares I Upper Stage. Called the Shared Volume, both vehicles contribute to its gas, fluid, and thermal environment. One of these environments is related to hazardous hydrogen gas. While both vehicles use inert purge gas to mitigate any hazardous gas buildup, there are concerns that hydrogen gas may still accumulate and that the Ares I Hazardous Gas Detection System will not be sufficient for monitoring the integrated volume. This Computational Fluid Dynamics (CFD) analysis has been performed to examine these topics. Results of the analysis conclude that the Ares I Hazardous Gas Detection System will be able to sample the vent effluent containing the highest hydrogen concentrations. A second conclusion is that hydrogen does not accumulate under the Orion Service Module (SM) avionics ring as diffusion and purge flow mixing sufficiently dilute the hydrogen to safe concentrations. Finally the hydrogen concentrations within the Orion SM engine nozzle may slightly exceed the 1 percent volume fraction when the entire worse case maximum full leak is directed vertically into the engine nozzle.

Ajmani, Kumud↗

Method of delivering lunar generated fluid to earth orbit using an external tank

A method and apparatus are provided for delivering lunar generated fluid to Earth orbit from lunar orbit. Transport takes place in an external tank of a shuttle which has been suitably outfitted in Earth orbit for reusable travel between Earth orbit and a lunar orbit. The outfitting of the external tank includes the adding of an engine, an electrical system, a communication system, a guidance system, an aerobraking device, and a plurality of interconnected fluid storage tanks to the hydrogen and oxygen tanks of the external tank. The external tank is then propelled to lunar orbit the first time using Earth-based propellant. In lunar orbit, the storage tanks are filled with the lunar generated fluid with the remainder tank volumes filled with lunar generated liquid oxygen and hydrogen which serve as propellants for returning the tank to Earth orbit where the fluid is off-loaded. The remaining lunar generated oxygen and hydrogen is then sufficient to return the external tank to lunar orbit so that a subsequent cycle of fluid delivery is repeated. A space station in a higher Earth orbit is preferably used to outfit the external tank, and a lunar node in lunar orbit is used to store and transfer the fluid and liquid oxygen and hydrogen to the external tank. The lunar generated fluid is preferably .sup.3 He.

Butterfield, Ansel J.↗

The CMC/3DPNS computer program for prediction of three-dimension, subsonic, turbulent aerodynamic juncture region flow. Volume 2: Users' manual

The CMC fluid mechanics program system was developed to transmit the theoretical solution of finite element numerical solution methodology, applied to nonlinear field problems into a versatile computer code for comprehensive flow field analysis. Data procedures for the CMC 3 dimensional Parabolic Navier-Stokes (PNS) algorithm are presented. General data procedures a juncture corner flow standard test case data deck is described. A listing of the data deck and an explanation of grid generation methodology are presented. Tabulations of all commands and variables available to the user are described. These are in alphabetical order with cross reference numbers which refer to storage addresses.

Manhardt, P. D.↗

The CMC/3DPNS computer program for prediction of three-dimensional, subsonic, turbulent aerodynamic juncture region flow. Volume 3: Programmers' manual

The CMC fluid mechanics program system was developed to transmit the theoretical evolution of finite element numerical solution methodology, applied to nonlinear field problems into a versatile computer code for comprehensive flow field analysis. A detailed view of the code from the standpoint of a computer programmer's use is presented. A system macroflow chart and detailed flow charts of several routines necessary to interact with a theoretican/user to modify the operation of this program are presented. All subroutines and details of usage, primarily for input and output routines are described. Integer and real scalars and a cross reference list denoting subroutine usage for these scalars are outlined. Entry points in dynamic storage vector IZ; the lengths of each vector accompanying the scalar definitions are described. A listing of the routines peculiar to the standard test case and a listing of the input deck and printout for this case are included.

Orzechowski, J. A.↗

Effect Of Leg Exercise On Vascular Volumes During Bed Rest

Report describes experiments on effects of no-exercise regimen and of two leg-exercise regimens on volumes of plasma, volumes of red blood cells, densities of bodies, and water balances of 19 men (32 to 42 years old) confined to minus 6 degrees-head-down bed rest for 30 days. Purpose of study to determine whether either or both exercise regimens maintain plasma volume and to relate levels of hypovolemia to body fluid balances. Results showed during bed rest, plasma volume maintained in isotomic group but not in other two groups, and no significant differences in body densities, body weights, or water balances among three groups. Concludes isotonic-exercise regimen better than isokinetic-exercise regimen for maintaining plasma volume during prolonged exposure to bed rest.

Greenleaf, J. E.↗

Latest developments in the MOOSE fluid properties module

The fluid properties module in MOOSE serves a variety of fluid simulation applications based on MOOSE, including the MOOSE Navier Stokes module~\cite{moose_ns}, Pronghorn~\cite{pgh}, SAM~\cite{sam}, the MOOSE thermal hydraulics module, RELAP-7~\cite{relap7} and subchannel~\cite{subchannel}. It is used for coarse mesh multi-dimensional thermal-hydraulics~\cite{pgh}, 1D systems analysis~\cite{sam,relap7} in nuclear reactor analysis, and porous flow simulations~\cite{porous} for underground gas storage and water seepage. The use of consistent fluid properties across fluid flow applications facilitates coupled simulations~\cite{anl_sam_pgh}. The module offers a consistent set of interfaces to implement to create a new fluid property. There are numerous fluid properties of interest in the entirety of all fields of fluid flow simulations, and this is exacerbated by the use of different variable sets depending on the compressibility of the fluid. For single-phase fluids, the following variable sets may be used to compute fluid properties: (pressure, temperature) and (specific volume, specific internal energy). Some properties may also be computed using the (pressure, density) or the (specific volume, specific enthalpy) variable sets. In order to reduce the challenge of adding a new fluid property, properties may be implemented partially.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sequentially coupled flow and geomechanical simulation with a discrete fracture model for analyzing fracturing fluid recovery and distribution in fractured ultra-low permeability gas reservoirs

More accurate characterization and prediction of the in-situ distribution of fracturing fluid in fractured reservoirs are needed for enhancing well productivity. In this study, an implicit-sequentially coupled flow/geomechanics simulator incorporating an efficient discrete fracture model is developed to model fluid distribution and recovery performance of ultra-low permeability gas reservoirs. The finite-volume and finite-element methods are used for space discretization of the flow and geomechanics equations, respectively, while the backward Euler method is employed for time discretization. The flow and geomechanics equations are solved sequentially based on fixed-stress splitting. An efficient discrete-fracture model is used to explicitly model the fractured system. Flexible unstructured gridding is employed to model arbitrarily-oriented fractures. The interrelations among pore volume, permeability and geomechanical conditions are considered dynamically using two-way coupled flow and geomechanics computations. The geometry of fracture (networks) due to hydraulic fracturing has significant impacts on the fracturing fluid recovery efficiency and ensuing fluid distribution. Under the same injection volume, the fracturing fluid recovery is higher when the fracture geometry is planar. Fluid recovery is relatively lower whenever natural fractures are activated during fracturing treatments; flowback time is also shortened when complex fracture network with enlarged fracture interface is present. Fracturing fluid in hydraulic fractures may leak off into the natural fractures and subsequently imbibes into the surrounding matrix due to capillarity effects. The fracturing fluid recovery and in-situ fluid distribution are sensitive to the shut-in duration and fracture closure behavior. This study analyzes the coupled flow-geomechanical responses of fractured gas reservoirs during the post-fracturing periods. Understanding the fate of the fracturing fluid can provide insights on, to some extent, the stimulated fracture volume, size of the water invasion zone, and efficiency of the fracturing design. The simulation predictions can also provide more accurate initial reservoir conditions (e.g. distributions of different phases and pressure) for long-term well performance estimation.

42 ENGINEERING↗

Lower body negative pressure - The second manned Skylab mission

Results of orthostatic evaluations of the crew of Skylab 3 with lower body negative pressure (LBNP) stress tests during their 59-d mission are reported. Except for an inflight increase (rather than a decrease) in resting heart rates, results were essentially parallel to those observed in crewmen of the shorter Skylab 2 mission. Exaggerated elevations in heart rate and decreases in pulse pressure during LBNP stress inflight and immediately postflight corresponded to lowered orthostatic tolerance. Large decrements is resting calf size inflight and in total leg volume postflight indicated significant headward fluid shifts as had already been seen in the Skylab 2 crewmen. In addition, decreases in calf circumference gave no certain indication of a plateau over the 59 d inflight. Percentage volume increase in calf size during LBNP stress inflight was greater than those in either preflight or postflight tests.

Johnson, R. L.↗

Assessment of Intraocular and Systemic Vasculature Pressure Parameters in Simulated Microgravity with Thigh Cuff Countermeasure

Changes in vision have been well documented among astronauts during and after long-duration space flight. One hypothesis is that the space flight induced headward fluid alters posterior ocular pressure and volume and may contribute to visual acuity decrements. Therefore, we evaluated venoconstrictive thigh cuffs as a potential countermeasure to the headward fluid shift-induced effects on intraocular pressure (IOP) and cephalic vascular pressure and volumes.

Huang, Alex S.↗

Development of an Atomization Methodology for Spray Combustion

In liquid rocket propulsion, the knowledge and the understanding of liquid-gas interfacial phenomena are very important. This is important for predicting the onset of cavitation occurring in swirl injection elements used in STME, as well as atomization processes in shear-induced injectors (co-axial) and impinging injector elements. From the fact that all the physical processes including droplet size distribution, droplet dispersion, mixing and combustion are controlled by atomization processes, it is expected that the successful incorporation of the volume of fraction (VOF) will greatly enhance the analytical capability of predicting spray combustion processes in liquid-fueled engines. In this paper, a methodology is developed to define and track interfaces between two fluids in non-orthogonal, body-fitted grids using a single fractional volume of fluid (VOF) variable to describe the distribution of the liquid phase in a gas-liquid flow field. This method was implemented in a mature CFD code MAST (Multiphase All-Speed Transient) utilizing the general PISO-C algorithm. For the preliminary study on the analysis of spray combustion and tracking of the interface between two phases, we will report on the progress of the simulation of the instability on the liquid column; the surface wave instability and the droplet breakup from the liquid surface.

Seung, S. P.↗

Deep-Sea Hydrothermal-Vent Sampler

An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral-precipitation temperature of 100 C but below the upper working temperature (230 C) of switching valves and tubes in the apparatus. The sample water then passes into a manifold tube, from whence the switching valves can direct the water through either a bypass tube or any one of the filter arrays, without contamination from a previous sample. Each filter array consists of series of filters having pore sizes decreasing in the direction of flow: 90-, 60-, 15-, and 7-micron prefilters and a large-surface-area 0.2-micron collection filter. All the filter taps are located between the intake and the bypass tube so that each time the bypass tube is used, the entire manifold tube is flushed as well.

Behar, Alberto E.↗