Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Droplet Evaporation-Based Approach for Microliter Fuel Property Measurements

Small-volume, high-throughput screening techniques are sought to enable downselection from a large candidate pool of bio-blendstocks to a select few, having physical properties consistent with requirements of downsized, turbo-boosted internal combustion engines. Herein, this work presents a droplet evaporation-based approach to predict heat of vaporization, vapor pressure, diffusion coefficient, and Lennard–Jones parameters for an unknown fuel. Two different schemes, considering the isothermal evaporation of a moving droplet in ambient air, are proposed, which combine droplet velocity and temperature measurements, with some known properties to predict unknown properties. The schemes utilize an inverse solution of a transient model of droplet evaporation solved in an iterative fashion. A baseline scheme, which only requires droplet size change measurements, is evaluated using test data for three liquid fuels, comprising of alkanes and alcohols, as obtained in a temperature-controlled chamber. Results yield temperature-dependent heat of vaporization and vapor pressure predictions within 10 % and 22 %, respectively, of reference values. The advanced scheme, which additionally requires droplet temperature measurement, is numerically evaluated in the current work and will be experimentally validated in future efforts. The advanced scheme is found to significantly improve prediction quality, with deviations less than 2 % and 1 % for heat of vaporization and vapor pressure, while also predicting diffusion coefficient and Lennard–Jones parameters within 5 % and 8 %, respectively. The combined set of approaches, which primarily track droplet evaporation, can be incorporated into a small-volume, high-throughput fuel screening process.

09 BIOMASS FUELS↗

Elevated central venous pressure: A consequence of exercise training-induced hypervolemia

Resting plasma volumes, and arterial and central venous pressures (CVP) were measured in 16 men before and after exercise training to determine if training-induced hypervolemia could be explained by a change in total vascular capacitance. In addition, resting levels of plasma vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (ALD), and norepinephrine (NE) were measured before and after training. The same measurements of vacular volume, pressures, and plasma hormones were measured in 8 subjects who did not undergo exercise and acted as controls. The exercise training program consisted of 10 weeks of controlled cycle exercise for 30 min/d, 4 d/wk at 75 to 80 percent of maximal oxygen uptake (VO2max). A training effect was verified by a 20 percent increase in VO2max, a resting bradycardia, and a 370 ml (9 percent) increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased. The percent change in blood volume from before to after training was linearly related to the percent change in CVP. As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was essentially unchanged following exercise training. Plasma AVP, ANP, ALD, and NE were unaltered. Results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance. This may represent a resetting of the pressure-volume stimulus-response relation for regulation of blood volume.

Convertino, Victor A.↗

Non-invasive measurement of leaf water content and pressure–volume curves using terahertz radiation

In this paper we describe a non-invasive method of measuring leaf water content using THz radiation and combine this with psychrometry for determination of leaf pressure–volume relationships. In contrast to prior investigations using THz radiation to measure plant water status, the reported method exploits the differential absorption characteristic of THz radiation at multiple frequencies within plant leaves to determine absolute water content in real-time. By combining the THz system with a psychrometer, pressure–volume curves were generated in a completely automated fashion for the determination of leaf tissue water relations parameters including water potential at turgor loss, osmotic potential at full turgor and the relative water content at the turgor loss point. This novel methodology provides for repeated, non-destructive measurement of leaf water content and greatly increased efficiency in generation of leaf PV curves by reducing user handling time.

59 BASIC BIOLOGICAL SCIENCES↗

Pulmonary tissue volume, cardiac output, and diffusing capacity in sustained microgravity

In microgravity (microG) humans have marked changes in body fluids, with a combination of an overall fluid loss and a redistribution of fluids in the cranial direction. We investigated whether interstitial pulmonary edema develops as a result of a headward fluid shift or whether pulmonary tissue fluid volume is reduced as a result of the overall loss of body fluid. We measured pulmonary tissue volume (Vti), capillary blood flow, and diffusing capacity in four subjects before, during, and after 10 days of exposure to microG during spaceflight. Measurements were made by rebreathing a gas mixture containing small amounts of acetylene, carbon monoxide, and argon. Measurements made early in flight in two subjects showed no change in Vti despite large increases in stroke volume (40%) and diffusing capacity (13%) consistent with increased pulmonary capillary blood volume. Late in-flight measurements in four subjects showed a 25% reduction in Vti compared with preflight controls (P < 0.001). There was a concomittant reduction in stroke volume, to the extent that it was no longer significantly different from preflight control. Diffusing capacity remained elevated (11%; P < 0.05) late in flight. These findings suggest that, despite increased pulmonary perfusion and pulmonary capillary blood volume, interstitial pulmonary edema does not result from exposure to microG.

Clinical Trial↗

Finding a contaminant source in a volume of flowing fluid

A method includes: mapping a boundary of a volume of flowing fluid; partitioning the volume by a computational mesh; finding a contaminant location at a first sensor that is disposed within the volume; obtaining a measured velocity of the flowing fluid within the volume; generating a reversed velocity vector field within the mesh, in response to the measured velocity; time stepping the contaminant location from the first sensor along the reversed velocity vector field until the contaminant location intersects the boundary of the volume; and finding a contaminant source at the intersection of the time stepped contaminant location with the boundary of the volume.

Lopez-Marrero, Vanessa↗

International Space Station Urine Monitoring System Functional Integration and Science Testing

Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

Cibuzar, Branelle R.↗

International Space Station Urine Monitoring System Functional Integration and Science Testing

Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

Rodriguez, Branelle R.↗

International Space Station Urine Monitoring System Functional Integration and Science Testing

Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

Rodriquez, Branelle R.↗

Theory of spectral radiance of pollutants at sea, volume 1

Remote measurement of pollutants dumped in the sea, not oil slicks, but soluble pollutants that change the color of the water, is addressed. The sensor is a spectral radiometer that flies over the polluted area and compares its spectral radiance (color) to that of surrounding clean seawater. The goal is to infer the concentration of pollutants using the measured radiance of the sea compared to laboratory measurements of reflection and transmission spectra of the pollutants. The subject is treated in three steps: (1) the quantities involved are defined and means for measuring them are described; (2) the equations for remote sensing with a low-flying aircraft are derived, in which wase the absorption and radiance of intervening air is negligible; and (3) high-flying aircraft and satellites are applied, in which case the radiance of intervening air is the major problem.

Source record↗

Sighting of El Chichon sulfur dioxide clouds with the Nimbus 7 total ozone mapping spectrometer

The eruptions of El Chichon volcano on March 28 and April 3 and 4, 1982 were observed by the Nimbus 7 total ozone mapping spectrometer due to strong absorption by volcanic gases at the shortest wavelengths of the spectrometer (312.5 and 317.5 nm). These ultraviolet pictures permit a measurement of the volume, dispersion, and drift of volcanic gas clouds. The tropospheric clouds were rapidly dispersed in westerly winds while persistent stratospheric clouds drifted in easterly winds at speeds up to 13 m/sec. The spectral reflectance is consistent with sulfur dioxide absorption and rules out carbon disulfide as a major constituent. A preliminary estimate of the mass of sulfur dioxide deposited in the stratosphere by the large eruptions on April 3 and 4 is 3.3 million tons. Prior estimates of volcanic cloud volume were based on extrapolation of locally measured sulfur dioxide concentrations.

Krueger, A. J.↗

Free-volume characteristics of epoxies

Positron annihilation spectroscopy was used to measure free-volume characteristics of selected epoxies. Fluorene resins, a new family of high-temperature thermosetting resins, were selected as the test medium. Experimental results indicate that the free-volume cell size V sub f varies with the molecular weight between the cross-links M sub c according to an equation of the form V sub f = AM sub c sup B, where A and B are structural constants. In two of the samples, the concentration of bulky fluorene groups was increased in the network backbone by replacement of some of the conventional bisphenol A epoxy resin with fluorene-derived epoxy resin. This resulted in an increase in their glass transition temperature for a given level of cross-linking. It was found that in these samples, the Doppler broadening of the annihilation peak decreases with the increasing fluorene content, presumably due to enhanced damping of the chain motions.

Singh, Jag J.↗

Entry Descent and Landing Workshop Proceedings: The Mars Science Laboratory (MSL) Entry, Descent and Landing Instrumentation (MEDLI) Hardware - Volume 1

Objectives: Measure Pressure: a) Confirm spacecraft aerodynamics. b) Independently measure attitude. c) Determine density profile. d) Determine wind component. Measure Temperature: a) Verify heating levels on spacecraft surface. b) Determine recession amount and rate. c) Validate material response at Mars conditions. The better we understand the Mars entry environment, the better we can design the next spacecraft.

Munk, Michelle M.↗

Airborne measurements of cloud-forming nuclei and aerosol particles in stabilized ground clouds produced by solid rocket booster firings

Airborne measurements of cloud volumes, ice nuclei and cloud condensation nuclei, liquid particles, and aerosol particles were obtained from stabilized ground clouds (SGCs) produced by Titan 3 launches at Kennedy Space Center, 20 August and 5 September 1977. The SGCs were bright, white, cumulus clouds early in their life and contained up to 3.5 g/m3 of liquid in micron to millimeter size droplets. The measured cloud volumes were 40 to 60 cu km five hours after launch. The SGCs contained high concentrations of cloud condensation nuclei active at 0.2%, 0.5%, and 1.0% supersaturation for periods of three to five hours. The SGCs also contained high concentrations of submicron particles. Three modes existed in the particle population: a 0.05 to 0.1 micron mode composed of aluminum-containing particles, a 0.2 to 0.8 micron mode, and a 2.0 to 10 micron mode composed of particles that contained primarily aluminum.

Hindman, E. E., II↗

Laser-induced incandescence applied to droplet combustion

Laser-induced incandescence (LII) is ideally suited for obtaining high temporally and spatially resolved measurements of soot volume fraction in transient combustion phenomena. We demonstrate qualitative two-dimensional nonintrusive optical measurements of the soot evolution versus time from single fiber-supported burning fuel droplets of heptane and decane. Quantitative measurement of the soot volume fraction is also demonstrated through calibration of the LII signal against a small coflow ethylene diffusion flame.

VanderWal, Randall L.↗

SAM 2 measurements of the polar stratospheric aerosol, volume 1: October to April 1979

Weekly averages of Antarctic and Arctic stratospheric aerosol data as well as corresponding temperature profiles for the time and place of each stratospheric aerosol measurement (SAM) II measurement during the first 6 months of satellite flight are presented. From the aerosol extinction profile data, contours of aerosol extinction as a function of altitude and longitude or time are plotted. Aerosol optical depths are calculated for each week. Polar stratospheric clouds at altitudes of about 22 km were observed during the Arctic winter at various times and locations. A representative sample of the first 6 months of data to be used in atmospheric and climatic studies is outlined.

Mccormick, M. P.↗

Flow Loop Study of ECT-Based Volume Fraction Monitoring in Oil–Water Two-Phase Flows

Measurement of phase volume fractions in water-containing multiphase flows is necessary for the optimization of a host of industrial flow processes. Many water-containing multiphase flows can be classified as either water-dispersed or water-continuous mixtures. A recently developed approach based on Hanai’s mixture formula and utilizing electrical capacitance tomography (ECT) sensors have shown good potential for obtaining water volume fraction estimates in two-phase water-containing flows with different water salinity levels. However, the proposed approach was investigated via controlled experiments restricted to static configurations while, in practice, multiphase flows can be dynamic and unpredictable. In this work, we perform a flow loop study of the proposed ECT-based method for volume fraction estimation in oil–water two-phase flows. Here, we evaluate the performance of the proposed method in both water-dispersed and water-continuous flow regimes by employing different types of capacitive sensors in cylindrical arrangements and parallel-plate rectangular arrangements.

02 PETROLEUM↗

The measurement of boundary layers on a compressor blade in cascade. Volume 1: Experimental technique, analysis and results

Measurements were made of the boundary layers and wakes about a highly loaded, double-circular-arc compressor blade in cascade. These laser Doppler velocimetry measurements have yielded a very detailed and precise data base with which to test the application of viscous computational codes to turbomachinery. In order to test the computational codes at off-design conditions, the data were acquired at a chord Reynolds number of 500,000 and at three incidence angles. Moreover, these measurements have supplied some physical insight into these very complex flows. Although some natural transition is evident, laminar boundary layers usually detach and subsequently reattach as either fully or intermittently turbulent boundary layers. These transitional separation bubbles play an important role in the development of most of the boundary layers and wakes measured in this cascade and the modeling or computing of these bubbles should prove to be the key aspect in computing the entire cascade flow field. In addition, the nonequilibrium turbulent boundary layers on these highly loaded blades always have some region of separation near the trailing edge of the suction surface. These separated flows, as well as the subsequent near wakes, show no similarity and should prove to be a challenging test for the viscous computational codes.

Zierke, William C.↗

Volume-change indicator for molding plastic

Monitor consisting of two concentric disks measures change in volume of charge during compression/displacement molding. Device enables operator to decide whether process pressure and temperature are set properly or whether sufficient material has been placed in mold.

Heler, W. C.↗