Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Incorporating bubble growth volume feedback to improve simulation of the response of a structure containing liquid and gas to sudden energy input

The SNS target module is a stainless-steel structure that contains and directs mercury. The mercury is struck with short, intense proton pulses to create neutrons. The pulses deposit energy and cause loads on the target structure and mercury cavitation. Helium bubbles are introduced into the mercury to reduce loads and cavitation. This gas complicates the prediction of the target module’s physical response. The current method used to simulate the structural response to the proton pulse incorporates a simple but effective approach to approximate mercury cavitation effects. This method cannot account for the changes from injected non-condensable gas. The ability to model the target vessel response is a prerequisite for estimating its life. Known approaches for simulating a bubbly fluid mixture’s response are computationally expensive and impractical for detailed engineering models. A constitutive model is proposed for target mercury with injected gas bubbles, with the intent of providing more accurate mercury–vessel response behavior without the computing costs required to track individual bubbles. The model’s assumptions and a computational model embodiment are described. The bubbly mercury computational model is subjected to test problems to assess its potential utility. Here, the model was able to better predict the effect of gas on wave propagation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Corrigendum to “Transport of intensity equation: A tutorial” Optics and Lasers in Engineering, Volume 135 (2020) 106187

In this Corrigendum, we correct misprints in equations and figures of the article titled “Transport of intensity equation: a tutorial” Optics and Lasers in Engineering, 135, 106187, 2020.1 These misprints were caused by unanticipated issues in email communication between the authors and the editorial team during the proofreading stage. The authors would like to apologize for any inconvenience caused.

36 MATERIALS SCIENCE↗

Improved light yield and growth of large-volume ultrafast single crystal scintillators Cs 2 ZnCl 4 and Cs 3 ZnCl 5

Due to their reported fast decay times, Cs 2 ZnCl 4 and Cs 3 ZnCl 5 are promising candidates for detection of gamma rays and X-rays in high count rate and fast timing applications. In this work, we show that single crystals with better optical quality than previously demonstrated – and larger in size – can be grown via the vertical Bridgman method. Highly transparent Ø7 mm crystals of undoped Cs 2 ZnCl 4 and Cs 3 ZnCl 5 are grown and measured to have light yields surpassing those previously reported, achieving 1980 ± 100 ph/MeV and 1460 ± 70 ph/MeV at 662 keV – a 55% and 232% improvement, respectively. We observe single-component scintillation decay times for both Cs 2 ZnCl 4 (1.66 ns) and Cs 3 ZnCl 5 (0.82 ns) and radioluminescence emission with maximum intensity at ~290 nm. Scalability of these materials is also evaluated based on growth of Ø22 mm crystals. Minimal cracking is observed, and the fast decay times are maintained at this size. Coincidence time resolution of 3 × 3 × 5 mm 3 and 7 × 7 × 10 mm 3 pixels cut from Ø22 mm Cs 2 ZnCl 4 are measured to be 148 ± 1 ps FWHM and 175 ± 1 ps FWHM, respectively. Here, the improved performance and ability to be fabricated in large sizes now place Cs 2 ZnCl 4 and Cs 3 ZnCl 5 on the map as potential contenders for radiation detection applications where BaF 2 – the most commonly used ultrafast inorganic scintillator – is typically considered.

36 MATERIALS SCIENCE↗

Comparison of atomized mass and crater volume in laser ablation

The extent and dynamics of laser ablation are typically studied using crater imaging or by invoking the relationship between atomic emission and the mass removed. The former is a static view of a dynamic process and requires the accumulation of multiple shots in one location. The latter is complex and not absolute without calibration of the optical system with a standard of spectral radiance. We measure the mass of the atomized plume by laser atomic-absorption spectroscopy at 2 µs without external mass calibration; mass uncertainty in laser-ablation atomic absorption spectroscopy (LA-AAS) results from uncertainties in line area fitting, tabulated oscillator strengths, and partition functions as well as a <10% underrepresentation of the mass due to treating the plasma as a single thermodynamic equilibrium. The LA-AAS-measured mass pertains to the atoms in the probed charge states and does not include condensed or molecular species. The ablation efficiency at 300 mbar of helium varies significantly between the two focusing conditions used. A comparison of crater-derived masses and LA-AAS masses suggests that more defocused ablation may result in significant redeposition of material in the crater, distorting the conclusions from drilling studies and crater imaging. More focused ablation conditions result in crater-derived masses that exceed those measured with LA-AAS and suggest melt expulsion or phase explosion.

Merten, Jonathan [Arkansas State University, Jones↗