Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

SAS4A/SASSYS-1 Verification Testing for Sodium Fast Reactor Applications (Acceptance Testing Report)

SAS4A/SASSYS-1 (SAS) is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal- cooled nuclear reactors. With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for over fifty years and represents a critical investment in safety analysis capabilities for the U.S. Department of Energy. To support demonstration of software pedigree and confirm key functional requirements, this report has been generated to provide detailed verification of the software. Although SAS was developed to support the analysis of any liquid-metal-cooled nuclear reactor, the acceptance testing described in this document focuses on the verification of SAS capabilities as they relate to pool-type Sodium Fast Reactors (SFRs). This report includes documentation of the test problem definition, analytical solution(s), computational solution(s), acceptance criteria, comparisons of analytical/computational solutions, and determination of acceptance of the computational solution(s). Deviations from acceptance criteria are noted.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Xyce Case Study

With the elimination of underground nuclear testing and declining defense budgets, science-based stockpile stewardship requires increased reliance on high performance modeling and simulation of weapon systems. Today's weapon systems are comprised of various electrical components and systems. As a result, there is a need for tools that will allow the use of massively parallel modeling and simulation techniques on high performance computers in existing and future weapons' electrical systems models. The Xyce Parallel Electronic Simulator is a SPICE (Simulation Program with Integrated Circuit Emphasis)- compatible circuit simulator designed to run on large-scale parallel computing platforms, though it can also execute efficiently on a variety of architectures including single processor workstations. As a mature platform for large-scale parallel circuit simulation, Xyce supports standard capabilities available in commercial simulators, in addition to various devices and models specific to Sandia's needs. Specifically, Xyce aids in the design and verification of electrical and electronic circuits and systems prior to weapons' manufacturing and deployment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Xyce Case Study

With the elimination of underground nuclear testing and declining defense budgets, science-based stockpile stewardship requires increased reliance on high performance modeling and simulation of weapon systems. Today's weapon systems are comprised of various electrical components and systems. As a result, there is a need for tools that will allow the use of massively parallel modeling and simulation techniques on high performance computers in existing and future weapons' electrical systems models. The Xyce Parallel Electronic Simulator is a SPICE (Simulation Program with Integrated Circuit Emphasis)- compatible circuit simulator designed to run on large-scale parallel computing platforms, though it can also execute efficiently on a variety of architectures including single processor workstations. As a mature platform for large-scale parallel circuit simulation, Xyce supports standard capabilities available in commercial simulators, in addition to various devices and models specific to Sandia's needs. Specifically, Xyce aids in the design and verification of electrical and electronic circuits and systems prior to weapons' manufacturing and deployment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Electron Weibel instability induced magnetic fields in optical-field ionized plasmas

Generation and amplification of magnetic fields in plasmas is a long-standing topic that is of great interest to both plasma and space physics. The electron Weibel instability is a well-known mechanism responsible for self-generating magnetic fields in plasmas with temperature anisotropy and has been extensively investigated in both theory and simulations, yet experimental verification of this instability has been challenging. Recently, we demonstrated a new experimental platform that enables controlled initialization of highly nonthermal and/or anisotropic plasma electron velocity distributions via optical-field ionization. Using an external electron probe bunch from a linear accelerator, the onset, saturation, and decay of the self-generated magnetic fields due to electron Weibel instability were measured for the first time to our knowledge. In this paper, we will first present experimental results on time-resolved measurements of the Weibel magnetic fields in non-relativistic plasmas produced by Ti:Sapphire laser pulses (0.8 μm) and then discuss the feasibility of extending the study to a quasi-relativistic regime by using intense CO 2 (e.g., 9.2 μm) lasers to produce much hotter plasmas.

36 MATERIALS SCIENCE↗

Liquid Chromatography Mass Spectrometry study of eutectic bis(2,2-dinitropropyl) acetal/formal

This study is the first attempt to document methodology development undergone using liquid chromatography tandem quadrupole time of flight mass spectrometry (LC-QTOF) to investigate degradation products of eutectic bis(2,2-dinitropropyl) acetal/formal nitroplasticizer (called NP here). Method properties investigated are: desolvation temperature (°C) and spray voltage (V) of the electrospray ionization source, and the development of an acetone system rinse to prevent any residual contamination between sample injections. Details are given on why it is essential to investigate method optimization with changes shown in MS/MS analysis in addition to MS results. Trends in MS/MS analytic results reveal important relationships between baseline and aged materials. In addition to verification of previously proposed fragments, insights offered by this newly developed methodology will also identify new degradation products and shed light on the complexity of NP degradation chemistry.

36 MATERIALS SCIENCE↗

Evaluation of a pair-based, joint-likelihood association approach for regional infrasound event identification

SUMMARY A Bayesian framework for the association of infrasonic detections is presented and evaluated for analysis at regional propagation scales. A pair-based, joint-likelihood association approach is developed that identifies events by computing the probability that individual detection pairs are attributable to a hypothetical common source and applying hierarchical clustering to identify events from the pair-based analysis. The framework is based on a Bayesian formulation introduced for infrasonic source localization and utilizes the propagation models developed for that application with modifications to improve the numerical efficiency of the analysis. Clustering analysis is completed using hierarchical analysis via weighted linkage for a non-Euclidean distance matrix defined by the negative log-joint-likelihood values. The method is evaluated using regional synthetic data with propagation distances of hundreds of kilometres in order to study the sensitivity of the method to uncertainties and errors in backazimuth and time of arrival. The method is found to be robust and stable for typical uncertainties, able to effectively distinguish noise detections within the data set from those in events, and can be made numerically efficient due to its ease of parallelization.

58 GEOSCIENCES↗

FY20 Verification of BISON Using Analytic and Manufactured Solutions

In 2010, the U.S. Department of Energy created its first Energy Innovation Hub, which is focused on developing high-fidelity and high-resolution Modeling and Simulation (M&S) tools for modeling of Light Water Reactors (LWRs). This hub, Consortium for Advanced Simulation of LWRs (CASL), has developed an LWR simulation tool called Virtual Environment for Reactor Applications (VERA). The multi-physics capability of VERA is achieved through the coupling of single-physics codes, including BISON, CTF, MPACT, and MAMBA. BISON is a fuel performance code which models the thermo-mechanical behavior of nuclear fuel using high performance M&S. It is capable of modeling traditional LWR fuel rods, fuel plates, and TRi-structural ISOtropic (TRISO) fuel particles. It can employ three-dimensional Cartesian, two-dimensional axisymmetric cylindrical, or one-dimensional radial spherical geometry. It includes empirical models for a large variety of fuel physics: temperature- and burnup-dependent thermal properties, fuel swelling and densification, fission gas production, cladding creep, fracture, cladding plasticity, and gap/plenum models. This document details a series of code verification test problems that are used to test BISON. These problems add confidence that the BISON code is a faithful representation of its underlying mathematical model. The suite of verification tests are mapped to the underlying conservation equations solved by the code: heat conduction, mechanics, and species conservation. Twenty-two problems are added for the heat conduction solution, two for the mechanics solution, and none for species conservation. Method of Manufactured Solutions (MMS) capability is demonstrated with three problems, and temperature drops across the fuel gap are tested.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Recommended Target Fields for Commissioning the Vera C. Rubin Observatory

The commissioning team for the Vera C. Rubin observatory is planning a set of engineering and science verification observations with the Legacy Survey of Space and Time (LSST) commissioning camera and then the Rubin Observatory LSST Camera. The time frame for these observations is not yet fixed, and the commissioning team will have flexibility in selecting fields to observe. In this document, the Dark Energy Science Collaboration (DESC) Commissioning Working Group presents a prioritized list of target fields appropriate for testing various aspects of DESC-relevant science performance, grouped by season for visibility from Rubin Observatory at Cerro Pachon. Our recommended fields include Deep-Drilling fields (DDFs) to full LSST depth for photo-$z$ and shape calibration purposes, HST imaging fields to full depth for deblending studies, and an $\sim$200 square degree area to 1-year depth in several filters for higher-level validation of wide-area science cases for DESC. We also anticipate that commissioning observations will be needed for template building for transient science over a broad RA range. We include detailed descriptions of our recommended fields along with associated references. We are optimistic that this document will continue to be useful during LSST operations, as it provides a comprehensive list of overlapping data-sets and the references describing them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical Solutions for Seismic Fluid-Structure Interaction of Head-Supported Cylindrical Tanks

Fluid-structure interaction (FSI) of earthquake shaking is a design consideration in the civil, nuclear, chemical, and mechanical industries. Preliminary sizing of structures and components in these industries will often use analytical solutions because there is insufficient information to warrant the analysis of numerical models. Here, this study extends prior analytical work on seismic FSI of base-supported tanks in the 1980s to accommodate head-supported tanks with geometries similar to those proposed for new-build, liquid (fluid)-filled, advanced reactors. Analytical solutions are derived for flexible, head-supported, cylindrical tanks subjected to small-amplitude, unidirectional, horizontal seismic motion, and address frequencies of lateral motions of the tank, hydrodynamic pressures, frequencies of waves, wave heights, and reactions at the head support. Solutions are presented for a range of tank dimensions and could be used for a) preliminary design of head-supported cylindrical tanks and their supporting structures with idealized seismic input, and b) verification of numerical models to be used for final seismic analysis, design, and probabilistic risk assessment.

42 ENGINEERING↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗

Absolute intensity calibration for carbon-edge soft X-ray scattering

Resonant soft X-ray scattering (RSOXS) has become a premier probe to study complex three-dimensional nanostructures in soft matter through combining the robust structural characterization of small-angle scattering with the chemical sensitivity of spectroscopy. This technique borrows many of its analysis methods from alternative small-angle scattering measurements that utilize contrast variation, but thus far RSOXS has been unable to reliably achieve an absolute scattering intensity required for quantitative analysis of domain compositions, volume fraction, or interfacial structure. Here, a novel technique to calibrate RSOXS to an absolute intensity at the carbon absorption edge is introduced. It is shown that the X-ray fluorescence from a thin polymer film can be utilized as an angle-independent scattering standard. Verification of absolute intensity is then accomplished through measuring the Flory–Huggins interaction parameter in a phase-mixed polymer melt. As a result, the necessary steps for users to reproduce this intensity calibration in their own experiments to improve the scientific output from RSOXS measurements are discussed.

47 OTHER INSTRUMENTATION↗

RISE: robust iterative surface extension for sub-nanometer X-ray mirror fabrication

Precision optics have been widely required in many advanced technological applications. X-ray mirrors, as an example, serve as the key optical components at synchrotron radiation and free electron laser facilities. They are rectangular silicon or glass substrates where a rectangular Clear Aperture (CA) needs to be polished to sub-nanometer Root Mean Squared (RMS) to keep the imaging capability of the incoming X-ray wavefront at the diffraction limit. The convolutional polishing model requires a CA to be extended with extra data, from which the dwell time is calculated via deconvolution. However, since deconvolution is very sensitive to boundary errors and noise, the existing surface extension methods can hardly fulfill the sub-nanometer requirement. On one hand, the figure errors in a CA were improperly modeled during the extension, leading to continuity issues along the boundary. On the other hand, uncorrectable high-frequency errors and noise were also extended. In this study, we propose a novel Robust Iterative Surface Extension (RISE) method that resolves these problems with a data fitting strategy. RISE models the figure errors in a CA with orthogonal polynomials and ensures that only correctable errors are fit and extended. Combined with boundary conditions, an iterative refinement of dwell time is then proposed to compensate the errors brought by the extension and deconvolution, which drastically reduces the estimated figure error residuals in a CA while the increase of total dwell time is negligible. To our best knowledge, RISE is the first data fitting-based surface extension method and is the first to optimize dwell time based on iterative extension. An experimental verification of RISE is given by fabricating two elliptic cylinders (10 mm × 80 mm CAs) starting from a sphere with a radius of curvature around 173 m using ion beam figuring. The figure errors in the two CAs greatly improved from 204.96 nm RMS and 190.28 nm RMS to 0.62 nm RMS and 0.71 nm RMS, respectively, which proves that RISE is an effective method for sub-nanometer level X-ray mirror fabrication.

36 MATERIALS SCIENCE↗

Development and Validation of Two-Phase Flow Models in MOOSE and Application to Molten Salt Reactors

Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated two new models into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model and a Euler-Euler model. The Euler-Euler model offers higher fidelity, while the mixture drift-flux model provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model's accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase models implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, both models are applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of both models for capturing the two-phase flow dynamics critical to MSR operations.

42 - ENGINEERING↗

Performance evaluation of cosmic ray muon trajectory estimation algorithms

Muons, being elementary particles with minimal interaction with nuclear materials and abundant at sea level, have sparked interest in utilizing them for imaging various applications, such as mining [Borselli et al., Sci. Rep. 12, 22329 (2022)], volcano imaging [Nagamine et al., Nucl. Instrum. Meth. A, 356, 585(1995)], and underground tunnel detection [Guardincerri et al., Pure Appl. Geophys. 174, 2133 (2017)]. Recently, their use in nuclear nonproliferation and safeguard verification has gained attention, particularly in cargo screening for nuclear waste smuggling [Baesso et al., J. Instrum. 9, C10041 (2014)], source localization [L. J. Schultz et al., Nucl. Instrum. Meth. A 519, 687 (2004)], and locating nuclear fuel debris in reactors [Borozdin et al., Phys. Rev. Let. 109, 152501 (2012)]. However, the resolution of muon image reconstruction techniques is limited due to multiple Coulomb scattering (MCS) within the target object. To achieve robust muon tomography, it is crucial to develop efficient and flexible physics-based algorithms that can model the MCS process accurately and estimate the most probable trajectory of muons as they pass through the target object. To address this limitation, in this study, a novel algorithmic approach utilizing the Bayesian probability theory and Gaussian approximation of MCS is chosen. Different energy levels, materials, and target sizes were considered in the evaluations. The results demonstrate that the Generalized Muon Trajectory Estimation (GMTE) algorithm offers significant improvements over currently used algorithms. Across all test scenarios, the GMTE algorithm demonstrated ~50% and 38% increase in precision compared to Straight Line Path (SLP) and Point of Closest Approach (PoCA) algorithms, respectively. Furthermore, it exhibited 10%–35% and 10%–15% increases in muon flux utilization for high and medium Z materials, respectively, compared to the PoCA algorithm. In conclusion, the extensive simulations confirm the enhanced performance and efficiency of the GMTE algorithm, offering improved resolution and reduced measurement time for cosmic ray muon imaging compared to the current SLP and PoCA algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal Experimental Design for Inverse Problems in the Presence of Observation Correlations

Optimal experimental design (OED) is the general formalism of sensor placement and decisions on the data collection strategy for engineered or natural experiments. This problem is prevalent in many critical fields such as battery design, numerical weather prediction, geosciences, environmental and urban studies. State-of-the-art computational methods for experimental design do not accommodate correlation structure in observational errors produced by many expensive-to-operate devices such as X-ray machines, radars, and satellites. Discarding evident data correlations leads to biased results, higher expenses, and waste of valuable resources. We present a general formulation of the OED formalism for model-constrained large-scale Bayesian linear inverse problems, where measurement errors are generally correlated. The proposed approach utilizes the Hadamard product of matrices to formulate the weighted-likelihood, and is valid for both finite as well as infinite-dimensional Bayesian inverse problems. Extensive numerical experiments are carried out for empirical verification of the proposed approach using an advection-diffusion model, where the objective is to optimally place a small set of sensors, under a limited budget, to predict the concentration of a contaminant in a closed and bounded domain.

Correlated observations↗

Engineering Methanogenic Microbiomes to Redirect Flux to Biomass

In this study, we present a method for acquiring and characterizing novel microbial consortia that regulates methanogens and methanotrophs through selective cultivation and metagenomic analysis of indigenous microorganisms in the environment. In addition, we present the work performed as part of this project to model the pathways that act as limiting factors in microbial methane metabolism based on a carbon cycle model. In this report, we describe the methods for selective cultivation of methane-metabolism-related microorganisms from environmental samples, the method for monitoring their methane consumption performance, and the method and results for verifying their functions using quantitative PCR and metagenomics techniques. The microbial consortia containing methanotrophs were obtained through selective cultivation and molecular biological verification, and their methane consumption performance was evaluated. In addition, the potential of the existence of bacteriophages interacting with methane metabolism-related microorganisms was identified through metagenomic sequencing.

09 BIOMASS FUELS↗