Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLTAGE AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Forced RF generation of CW magnetrons for superconducting accelerators

CW magnetrons, designed and optimized for industrial RF heaters, were suggested to power Superconducting RF cavities due to their higher efficiency and lower cost than traditional klystrons, IOT’s, or solid-state amplifiers. RF amplifiers driven by a master-oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. Very large regenerative gain causes instability with intense noise when a magnetron operates with the anode voltage higher than the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection-locking by a quite small signal. In this case the CW magnetrons do not provide correlation of the magnetron startup with the injection-locking signal. Thus, the magnetron except the injection locked oscillations may generate large noise. This may increase emittance of the beam in SRF accelerators. Recently we have developed mode for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for SRF accelerators. The mode is briefly described below.

43 PARTICLE ACCELERATORS↗

X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells

X-ray beam induced current (XBIC) measurements allow mapping of the nanoscale performance of electronic devices such as solar cells. Ideally, XBIC is employed simultaneously with other techniques within a multi-modal X-ray microscopy approach. An example is given herein combining XBIC with X-ray fluorescence to enable point-by-point correlations of the electrical performance with chemical composition. For the highest signal-to-noise ratio in XBIC measurements, lock-in amplification plays a crucial role. By this approach, the X-ray beam is modulated by an optical chopper upstream of the sample. The modulated X-ray beam induced electrical signal is amplified and demodulated to the chopper frequency using a lock-in amplifier. By optimizing low-pass filter settings, modulation frequency, and amplification amplitudes, noise can efficiently be suppressed for the extraction of a clear XBIC signal. A similar setup can be used to measure the X-ray beam induced voltage (XBIV). Beyond standard XBIC/XBIV measurements, XBIC can be measured with bias light or bias voltage applied such that outdoor working conditions of solar cells can be reproduced during in-situ and operando measurements. Ultimately, the multi-modal and multi-dimensional evaluation of electronic devices at the nanoscale enables new insights into the complex dependencies between composition, structure, and performance, which is an important step towards solving the materials' paradigm.

14 SOLAR ENERGY↗

Applications of excimer lasers for atmospheric species measurements

Excimer lasers are proven sources of high pulse energy and high average power coherent radiation at several wavelength regions throughout the ultraviolet spectrum. If designed properly, excimer lasers can be operated with both low divergence and narrow spectral bandwidth, and using an oscillator - injection-locked amplifier configuration they can be tuned over a 10 to 20 A bandwidth without appreciable loss in energy. Additional wavelength coverage from excimer lasers can be obtained by stimulated Raman scattering. With the development of magnetic switching for the high voltage, high power switches, the electric discharge excimer laser can also be operated reliably for extended periods of time at high pulse rates. All these features make excimer lasers ideal sources of ultraviolet radiation for a variety of remote and in-situ atmospheric species measurements.

Laudenslager, J. B.↗

Toward Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ): Initial fabrication and characterization

Purpose We present the first prototype Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ). This detector includes a layer of avalanche amorphous Selenium (a‐Se) ( HARP ) as the photoconductor in an indirect detector to amplify the signal and reduce the effects of electronic noise to obtain quantum noise‐limited images for low‐dose applications. It is the first time avalanche a‐Se has been used in a solid‐state imaging device and poses as a possible solution to eliminate the effects of electronic noise, which is crucial for low‐dose imaging performance of AMFPI . Methods We successfully deposited a solid‐state HARP structure onto a 24 × 30 cm 2 array of thin‐film transistors ( TFT array) with a pixel pitch of 85 μm. The HARP layer consists of 16 μm of a‐Se with a hole‐blocking and electron‐blocking layer to prevent charge injection from the high‐voltage bias and pixel electrodes, respectively. An electric field ( E S e ) up to 105 V μm −1 was applied across the a‐Se layer without breakdown. A 150 μm thick‐structured CsI:Tl scintillator was used to form SHARP ‐ AMFPI . The x‐ray imaging performance is characterized using a 30 kV p Mo/Mo beam. We evaluate the spatial resolution, noise power, and detective quantum efficiency at zero frequency of the system with and without avalanche gain. The results are analyzed using cascaded linear system model ( CLSM ). Results An avalanche gain of 76 ± 5 was measured at E S e = 105 V μm −1 . We demonstrate that avalanche gain can amplify the signal to overcome electronic noise. As avalanche gain is increased, image quality improves for a constant (0.76 mR ) exposure until electronic noise is overcome. Our system is currently limited by poor optical transparency of our high‐voltage electrode and long integrating time which results in dark current noise. These two effects cause high‐spatial frequency noise to dominate imaging performance. Conclusions We demonstrate the feasibility of a solid‐state HARP x‐ray imager and have fabricated the largest active area HARP sensor to date. Procedures to reduce secondary quantum and dark noise are outlined. Future work will improve optical coupling and charge transport which will allow for frequency DQE and temporal metrics to be obtained.

Scheuermann, James R.↗

Mars Global Surveyor Ka-Band Frequency Data Analysis

The Mars Global Surveyor (MGS) spacecraft, launched on November 7, 1996, carries an experimental space-to-ground telecommunications link at Ka-band (32 GHz) along with the primary X-band (8.4 GHz) downlink. The signals are simultaneously transmitted from a 1.5-in diameter parabolic high gain antenna (HGA) on MGS and received by a beam-waveguide (BWG) R&D 34-meter antenna located in NASA's Goldstone Deep Space Network (DSN) complex near Barstow, California. The projected 5-dB link advantage of Ka-band relative to X-band was confirmed in previous reports using measurements of MGS signal strength data acquired during the first two years of the link experiment from December 1996 to December 1998. Analysis of X-band and Ka-band frequency data and difference frequency (f(sub x)-f(sub ka)/3.8) data will be presented here. On board the spacecraft, a low-power sample of the X-band downlink from the transponder is upconverted to 32 GHz, the Ka-band frequency, amplified to I-W using a Solid State Power Amplifier, and radiated from the dual X/Ka HGA. The X-band signal is amplified by one of two 25 W TWTAs. An upconverter first downconverts the 8.42 GHz X-band signal to 8 GHz and then multiplies using a X4 multiplier producing the 32 GHz Ka-band frequency. The frequency source selection is performed by an RF switch which can be commanded to select a VCO (Voltage Controlled Oscillator) or USO (Ultra-Stable Oscillator) reference. The Ka-band frequency can be either coherent with the X-band downlink reference or a hybrid combination of the USO and VCO derived frequencies. The data in this study were chosen such that the Ka-band signal is purely coherent with the X-band signal, that is the downconverter is driven by the same frequency source as the X-band downlink). The ground station used to acquire the data is DSS-13, a 34-meter BWG antenna which incorporates a series of mirrors inside beam waveguide tubes which guide the energy to a subterranean pedestal room, providing a stable environment for the feed and electronics equipment. A dichroic plate is used to reflect the X-band energy and pass the Ka-band energy to another mirror. The RF energy for each band is then focused onto a feed horn and low-noise amplifier package. After amplification and RF/IF downconversion, the IF signals are sent to the Experimental Tone Tracker (ETT), a digital phase-lock-loop receiver, which simultaneously tracks both X-band and Ka-band carrier signals. Once a signal is detected, the ETT outputs estimates of the SNR in a I -Hz bandwidth (Pc/No), baseband phase and frequency of the signals every I -sec. Between December 1996 and December 1998, the Ka-band and X-band signals from MGS were tracked on a regular basis using the ETT. The Ka-band downlink frequencies described here were referenced to the spacecraft's on-board USO which was also the X-band frequency reference (f(sub ka)= 3.8 f(sub x)). The ETT estimates of baseband phase at I -second sampled time tags were converted to sky frequency estimates. Frequency residuals were then generated for each band by removing a model frequency from each observable frequency at each time tag. The model included Doppler and other effects derived from spacecraft trajectory files obtained from the MGS Navigation Team. A simple troposphere correction was applied to the data. In addition to residuals, the USO frequencies emitted by the spacecraft were estimated. For several passes, the USO frequencies were determined from X-band data and from Ka-band data (referred to X-band by dividing by 3.8) and were found to be in good agreement. In addition, X-band USO frequency estimates from MGS Radio Science data acquired from operational DSN stations were available for comparison and were found to agree within the I Hz level. The remaining sub-Hertz differences were attributed to the different models and software algorithms used by MGS Radio Science and KaBLE-11. A summary of the results of a linear fit of the USO frequency versus time (day of year) is presented in Table I for an initial segment of passes.

Morabito, D.↗

Gallium nitride based power switches for next generation of power conversion

Power conversion impacts all areas of electricity consumption, including motion control, lighting, air conditioning, and information technology. Si, the workhorse of the industry, has served well so far but reached its material limits. To keep up with the advancement of technologies enabling new conveniences, power conversion techniques need to go through significant transformation that calls for the next generation semiconductor for power switching. SiC and GaN, which have the potential to push the envelope beyond Si providing solutions for the entire range of power conversion at higher efficiencies and reduced form factors. GaN HEMTs have an added advantage over SiC MOSFETs owing to the high-mobility electron channel formed at the AlGaN/GaN interface, which has been the basis of radio frequency amplifiers. GaN has enabled systems that can run with lesser cooling at frequencies at least ten times higher than current Si-based systems, significantly reducing the form factor both electrically (passive components) and mechanically (heat sinks). The high current and voltage required for high power conversion application make the chip area in a lateral topology uneconomical and difficult to manufacture. Vertical GaN devices on bulk GaN substrates complete the portfolio of power switches required to address the power conversion market.

Chowdhury, S↗

Single-Event Effect Testing of the Linear Technology LTC6103HMS8#PBF Current Sense Amplifier

The LTC6103HMS8#PBF (henceforth abbreviated as LTC6103) current sense amplifier from Linear Technology was tested for both destructive and non-destructive single-event effects (SEE) using the heavy-ion cyclotron accelerator beam at Lawrence Berkeley National Laboratory (LBNL) Berkeley Accelerator Effects (BASE) facility. During testing, the input voltages and output currents were monitored to detect single event latch-up (SEL) and single-event transients (SETs).

single-event effects (SEE)↗

Phase locking of an S-band wide-gap klystron amplifier with high power injection driven by a relativistic backward wave oscillator

Theoretical analyses and preliminary experiments on the phase-locking characteristics of an inductively loaded 2-cavity wide-gap klystron amplifier (WKA) with high power injection driven by a GW-class relativistic backward wave oscillator (RBWO) are presented. Electric power of the amplifier and oscillator is supplied by a single accelerator being capable of producing dual electron beams. The well phase-locking effect of the RBWO-WKA system requires the oscillator have good frequency reproducibility and stability from pulse to pulse. Thus, the main switch of the accelerator is externally triggered to stabilize the diode voltage and then the working frequency. In the experiment, frequency of the WKA is linearly locked by the RBWO. With a diode voltage of 530 kV and an input power of {approx}22 MW, an output power of {approx}230 MW with the power gain of {approx}10.2 dB is obtained from the WKA. As the main switch is triggered, the relative phase difference between the RBWO and the WKA is less than {+-}15 Degree-Sign in a single shot, and phase jitter of {+-}11 Degree-Sign is obtained within a series of shots with duration of about 40 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An X-band high-impedance relativistic klystron amplifier with an annular explosive cathode

The feasibility of employing an annular beam instead of a solid one in the X-band high-impedance relativistic klystron amplifier (RKA) is investigated in theory and simulation. Small-signal theory analysis indicates that the optimum bunching distance, fundamental current modulation depth, beam-coupling coefficient, and beam-loaded quality factor of annular beams are all larger than the corresponding parameters of solid beams at the same beam voltage and current. An annular beam RKA and a solid beam RKA with almost the same geometric parameters are compared in particle-in-cell simulation. Output microwave power of 100 MW, gain of 50 dB, and power conversion efficiency of 42% are obtained in an annular beam RKA. The annular beam needs a 15% lower uniform guiding magnetic field than the solid beam. Our investigations demonstrate that we are able to use a simple annular explosive cathode immersed in a lower uniform magnetic field instead of a solid thermionic cathode in a complicated partially shielding magnetic field for designing high-impedance RKA, which avoids high temperature requirement, complicated electron-optical system, large area convergence, high current density, and emission uniformity for the solid beam. An equivalent method for the annular beam and the solid beam on bunching features is proposed and agrees with the simulation. The annular beam has the primary advantages over the solid beam that it can employ the immersing uniform magnetic field avoiding the complicated shielding magnetic field system and needs a lower optimum guiding field due to the smaller space charge effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact readout of large CLYC scintillators with silicon photomultipler arrays

Compact readout of a large (5 x 5 x 5 cm 3) CLYC scintillator was demonstrated with a 8 x 8 array of 6mm silicon photomultipliers (SiPMs, specifically, a SensL ArrayJ-60035-64P) and an optimized amplification and summing circuit. Read out by the SiPM array, the crystal yielded an energy resolution of 5.5% at 662 keV and a figure of merit of 3.5, equivalent to the performance achieved with a 3-inch Hamamatsu R6233-100 PMT. To reduce channel count and avoid individual amplification of each SiPM in the array, the standard outputs of 16 SiPMs were passively summed then amplified. A current feedback amplifier was used for each channel to provide the required fast response time. The four amplified channels were then passively summed resulting in a single signal channel. A custom laboratory setup, based on the PSD8C ASIC, was used to capture the output and provide time-gated integration for PSD computation. We conclude the compact volume, low bias voltage, and reduced mass of the SiPM array readout are desirable for space and national security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On operation and control of CW magnetrons for superconducting accelerators

CW magnetrons, developed for industrial RF heaters, were suggested to feed RF cavities of superconducting accelerators due to higher efficiency and lower cost of RF power than provide traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF auto generators with a huge regenerative gain. This causes regenerative instability with a notable noise when a magnetron operates as an auto generator i.e., with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for phase stabilization of magnetrons. In this case CW magnetrons with the injection-locked (coherent) oscillations generate a notable level of noise. This may preclude use of CW magnetrons in this mode in the Superconducting RF (SRF) accelerators. This paper reviews PIC modeling and previously obtained experimental results for the operation and control of CW magnetrons, which led to the development of techniques most suitable for various SRF accelerators using forced RF oscillation of magnetrons, when the magnetron is launched by an injected forcing signal, and regenerative noise is suppressed.

Kazakevich, G. [MUONS Inc., Batavia] (ORCID:000000↗

Application of Derivative Spectrometry to the Analysis of Trace Gases

A derivative spectrometer is sensitive to changes in spectral intensity over narrow wavelength internal. Specifically, a second derivative spectrometer senses the curvature of the incident spectral intensity, providing an output voltage signal proportional to the second derivative of intensity with respect to wavelength. When such an instrument is combined with multi-pass White cell, a unique trace gas analyzer results. The analyzer, operating within the middle ultraviolet spectral region, provides a highly amplified derivative spectrum of any molecular narrow band absorption which is used for trace gas identification. The intensity of any peak within a spectrum is proportional to the trace gas concentration. Such an analyzer, utilizing a 20 meter pathlength White cell, is presently being used to automatically monitor ambient air for SO2, NO, NO2, and O3 with minimum detectable concentration limits in the part per billion range.

Hager, Robert N.↗

DC isolation and protection system and circuit

A precision analog electronic circuit that is capable of sending accurate signals to an external device that has hostile electric characteristics, including the presence of very large common mode voltages. The circuit is also capable of surviving applications of normal mode overvoltages of up to 120 VAC/VDC for unlimited periods of time without damage or degradation. First, the circuit isolates the DC signal output from the computer. Means are then provided for amplifying the isolated DC signal. Further means are provided for stabilizing and protecting the isolating and amplifying means, and the isolated and amplified DC signal which is output to the external device, against overvoltages and overcurrents.

Wagner, Charles A.↗

Analytic investigation of efficiency and performance limits in klystron amplifiers using multidimensional computer programs; multi-stage depressed collectors; and thermionic cathode life studies

Due to complexity of the program which used a hydrodynamic, axially and radially deformable disk-ring model and the resulting long computing time only the output gap was investigated. Results from independent studies were used to initiate the starting conditions for the electrons and the RF voltage using our program. Although this method of computation is less exact than processing the entire klystron interaction in 3-Dimensions it is shown that, for a confined flow focused throughout the penultimate cavity, radial velocities remain very small and the beam is highly laminar. It is concluded that possible errors resulting from treating only the output cavity in 3-D would remain small.

Kosmahl, H. G.↗

A Test for the Existence of Mach Effects with a Rotary Device

Owing to the variation in the results of several experiments designed to produce thrust with devices employing Mach effects, it was decided to design an experiment with the simple purpose of determining whether or not Mach effects actually exist, and if they can be produced when the ''bulk'' acceleration and internal energy changes required to produce them are separately supplied. In the experiment arrays of eight 500 pf high voltage capacitors are mounted on the end of a rotor and spun to and from speeds of about 60 Hz (3600 rpm) while they are excited with a 40 KHz voltage signal with amplitudes up to 6 KV. The capacitors are sandwiched between two accelerometers and any Mach effect mass fluctuation is detected as a weight fluctuation that produces signals in the accelerometers that are antiphase. Those signals are subtracted with a differential instrumentation amplifier that suppresses other signals as common mode noise. Signals with the properties sought have been found and recorded with video equipment. They suggest that Mach effects are real, and that the bulk accelerations and internal energy changes that produce them can in fact be separately supplied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High power microwave source with a three dimensional printed metamaterial slow-wave structure

For over the last decade, the concept of metamaterials has led to new approaches for considering the interaction of radiation with complex structures. However, practical manifestations of such a device operating at high power densities have proven difficult to achieve due to the resonant nature of metamaterials and the resultant high electric fields, which place severe constraints on manufacturing the slow wave structures. In this paper, we describe the first experimental manifestation of a high power microwave device utilizing a metallic slow wave structure (metamaterial-like) fabricated using additive manufacturing. The feasibility of utilizing additive manufacturing as a technique for building these relatively complicated structures has thus been demonstrated. The MW class microwave source operates in the C-band and shows frequency tunablility with electron beam voltage. The basic electromagnetic characteristics of this device, the construction using additive manufacturing, and the basic performance as a microwave oscillator are considered. Due to the tunable nature of the device, it shows promise not only as an oscillator but also as a microwave amplifier. Therefore, the dispersive characteristics and a discussion of the anticipated gain is included as it relates to an amplifier configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Magnetron Stability and Reduced Noise in Efficient Transmitters for Superconducting Accelerators

State of the art high-current superconducting accelerators require efficient RF sources with a fast dynamic phase and power control. This allows for compensation of the phase and amplitude deviations of the accelerating voltage in the Superconducting RF (SRF) cavities caused by microphonics, etc. Efficient magnetron transmitters with fast phase and power control are attractive RF sources for this application. They are more cost effective than traditional RF sources such as klystrons, IOTs and solid-state amplifiers used with large scale accelerator projects. However, unlike traditional RF sources, controlled magnetrons operate as forced oscillators. Study of the impact of the controlling signal on magnetron stability, noise and efficiency is therefore important. This paper discusses experiments with 2.45 GHz, 1 kW tubes and verifies our analytical model which is based on the charge drift approximation.

Kazakevich, G.↗

Skipper-CCD Output Sensitivity Improvement with a Common Source Cascode Amplifier

A Skipper-CCD output has been traditionally readout in a source follower configuration, also known as common drain, mainly because in this configuration a good compromise between sensitivity, noise and speed is achieved. In this work a different approach is presented: the output transistor is connected in a common source configuration and an external cascode device is added in series, obtaining a voltage gain higher than unity without increasing significantly the parasitic capacitance due to Miller effect and thus increasing the obtained voltage per electron of charge. The proposed output stage improves the sensitivity 3.4 times when compared with the traditionally used stage while keeping almost the same equivalent noise charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗