Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UNLOADING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Cardiovascular Responses to Simulated Spaceflight: Molecular Signatures and Surrogate Outputs to Measure CVD Risk

During extended space missions beyond low Earth orbit, astronauts will encounter prolonged periods of weightlessness and low dose space radiation. Previous studies have shown that exposure to small doses of high LET radiation (< 50 cGy) can lead to both short-term and long-term alterations in heart function, structure and underlying molecular mechanisms. In this study, we aim to identify the molecular signature associated with the cardiovascular response to simulated galactic cosmic radiation (5-ion GCR) alone or in combination with simulated weightlessness at time intervals relevant to mission length and recovery. Additionally, we aim to determine whether sex impacts cardiovascular responses to these spaceflight factors. Our overarching goal is to enhance our understanding of the cardiovascular risks associated with extended space missions and the clinical endpoints they suggest. We hypothesize that exposure to simulated space radiation leads to enduring alterations in the transcriptome, redox signaling and cytokine environment of cardiovascular tissue, some which have known links with reduced cardiovascular performance, aging, and increased risk of cardiovascular disease (CVD). Furthermore, we posit that simulated space radiation exposure in combination with simulated microgravity exacerbates cardiovascular deficits compared to single factor exposure. Female and male C57BL/6J mice, aged 23-24 weeks, were exposed to a single dose of 5, 15, or 50 cGy of 5-ion GCR, or sham-treated (0 cGy). Euthanasia was performed at 14 days and ~4 months post-irradiation. Hearts, aorta and blood plasma were collected shortly thereafter. RNA-sequencing of left ventricles at ~4 months post-GCR exposure revealed sex differences in the heart transcriptome with a few genes showing radiation-dependent changes in expression levels. Notably, some of the differentially expressed genes in 15 and 50 cGy GCR groups are known to play roles in the development of CVD. Analysis of protein levels of a subset of inflammatory cytokines in the heart indicated sex differences but no differences between sham and 50 cGy groups. Results also showed correlations among differentially expressed genes and a subset of inflammatory cytokines, with some correlations altered by GCR exposure. These findings suggest that GCR exposure can modify protein and gene networks linked to inflammation and CVD progression. In the aorta, telomere lengths were comparable across treatment groups sexes. Mitochondrial copy number is a biomarker for mitochondrial function with decreased copy numbers associated with cardiometabolic disease traits. Mitochondrial copy numbers of aorta also showed no sex nor dose differences. In a second study, mice underwent one week of simulated microgravity by hindlimb unloading (HU) and then exposed to a single dose of 15 cGy of 5-ion GCR. HU was conducted for an additional two weeks following GCR exposure. Single factor exposure groups (HU or GCR only) also were included in the study. Euthanasia was then performed and the same tissues were collected. Protein levels of select inflammatory cytokines in the heart showed sex-dependent differences in expression. In the aorta, telomere lengths and mitochondrial copy number also showed sex differences. In summary, our results indicate differences between sexes in biomarkers related to cardiovascular health. Exposure to 5-ion GCR or HU, alone or in combination, did not result in changes in most of the cardiovascular biomarkers that were examined. However, in the heart, simulated space radiation at doses of 15 and 50 cGy led to long-term alterations in the expression levels of a small group of genes known to be associated with the progression of CVD. The long-term transcriptomic changes resulting from exposure to simulated space radiation should be carefully investigated to mitigate adverse cardiovascular events during and after deep space missions. Our results also highlight the importance of sex-specific strategies in monitoring and maintaining cardiovascular health during and after deep space missions.

cardiovascular↗

A Load-based Depth-sensing Indentation Technique for NDE and Life Assessment of Thermal Barrier Coatings

In this paper, we present a load-based micro-indentation technique for evaluating material mechanical properties as well as degradation evaluation and debonding/spallation detection of thermal barrier coating (TBC) materials. Instead of using contact area as a necessary parameter, the new technique is based on the indentation load. Coupled with a multiple-partial unloading procedure during the indentation process, this technique results in a load-depth sensing indentation system capable of determining Young’s modulus of metals, superalloys, and single crystal matrices, and stiffness of coated material systems with flat, tubular, or curved architectures. This micro-indentation technique can be viewed as a viable non-destructive evaluation (NDE) technique for determining as-manufactured and process-exposed metal, superalloy, single crystal, and TBC-coated material properties. This technique also shows promise for the development of a portable instrument for on-line, in-situ NDE and mechanical properties measurement of structural components.

36 MATERIALS SCIENCE↗

A Load-based Micro-indentation Technique for Mechanical Property and NDE Evaluation

A load-based micro-indentation technique has been developed for evaluating mechanical properties of materials. Instead of using measured indentation depth or contact area as a necessary parameter, the new technique is based on the indentation load, coupled with a multiple-partial unloading procedure for mechanical property evaluation. The proposed load-based micro-indentation method is capable of determining Young’s modulus of metals, superalloys, and single crystal matrices, and stiffness of coated material systems with flat, tubular, or curved architectures. This micro-indentation technique can be viewed as a viable non-destructive evaluation (NDE) technique for determining as-manufactured and process-exposed metal, superalloy, single crystal, and TBC-coated material properties. Based on this technique, several bond coated substrates were tested at various stages of thermal cycles. The time-series evaluation of test material surface stiffness reveals the status of coating strength without any alternation of the coating surface, making it a true time-series NDE investigation. The microindentation test results show good correlation with post mortem microstructural analyses. This technique also shows promise for the development of a portable instrument for on-line, in-situ NDE and mechanical properties measurement of structural components.

36 MATERIALS SCIENCE↗

NON-DESTRUCTIVE TBC SPALLATION DETECTION BY A MICRO-INDENTATION METHOD

In this research, a load-based depth-sensing micro-indentation method for spallation detection and damage assessment of thermal barrier coating (TBC) materials is presented. A non-destructive multiple loading/partial unloading testing methodology was developed where in stiffness responses of TBC coupons subjected to various thermal cyclic loading conditions were analyzed to predict the spallation site and assess TBC degradation state. The measured stiffness responses at various thermal loading cycles were used to generate time-series color maps for correlation with accumulation of TBC residual stress states. The regions with higher stiffness responses can be linked to a rise in out-of-plane residual stress located near or at the yttria stabilized zirconia (YSZ)/thermally grown oxide (TGO) interface, which is ultimately responsible for initiating TBC spallation failure. A TBC thermal exposure testing plan was carried out where time-series cross-sectional microstructural analyses of damage accumulation and spallation failure associated with the evolution of bond coat/TGO/top coat composite (e.g. thickness, ratcheting, localized oxidations, etc.) of air plasma sprayed (APS) TBCs were evaluated and correlated to the measured stiffness responses at various thermal cycles. The results show that the load-based micro-indentation test methodology is capable of identifying the spallation site(s) before actual occurrence. This micro-indentation technique can be viewed as a viable non-destructive evaluation (NDE) technique for determining as-manufactured and process-exposed TBCs. This technique also shows promise for the development of a portable instrument for on-line, in-situ spallation detection/prediction of industrial-size TBC turbine components.

36 MATERIALS SCIENCE↗

The effects of shockwave profile shape and shock obliquity on spallation in Cu and Ta: kinetic and stress-state effects on damage evolution(u)

Widespread research over the past five decades has provided a wealth of experimental data and insight concerning shock hardening and the spallation response of materials subjected to square-topped shock-wave loading profiles. Less quantitative data have been gathered on the effect of direct, in-contact, high explosive (HE)-driven Taylor wave (or triangular-wave) loading profile shock loading on the shock hardening, damage evolution, or spallation response of materials. Explosive loading induces an impulse dubbed a 'Taylor Wave'. This is a significantly different loading history than that achieved by a square-topped impulse in terms of both the pulse duration at a fixed peak pressure, and a different unloading strain rate from the peak Hugoniot state achieved. The goal of this research is to quantify the influence of shockwave obliquity on the spallation response of copper and tantalum by subjecting plates of each material to HE-driven sweeping detonation-wave loading and quantify both the wave propagation and the post-mortem damage evolution. This talk will summarize our current understanding of damage evolution during sweeping detonation-wave spallation loading in Cu and Ta and show comparisons to modeling simulations. The spallation responses of Cu and Ta are both shown to be critically dependent on the shockwave profile and the stress-state of the shock. Based on variations in the specifics of the shock drive (pulse shape, peak stress, shock obliquity) and sample geometry in Cu and Ta, 'spall strength' varies by over a factor of two and the details of the mechanisms of the damage evolution is seen to vary. Simplistic models of spallation, such as P{sub min} based on 1-D square-top shock data lack the physics to capture the influence of kinetics on damage evolution such as that operative during sweeping detonation loading. Such considerations are important for the development of predictive models of damage evolution and spallation in metals and alloys.

36 MATERIALS SCIENCE↗

Phased array compaction cell for measurement of the transversely isotropic elastic properties of compacting sediments

Sediments undergoing compaction typically exhibit transversely isotropic (TI) elastic properties. We present a new experimental apparatus, the phased array compaction cell, for measuring the TI elastic properties of clay-rich sediments during compaction. This apparatus uses matched sets of P- and S-wave ultrasonic transducers located along the sides of the sample and an ultrasonic P-wave phased array source, together with a miniature P-wave receiver on the top and bottom ends of the sample. The phased array measurements are used to form plane P-waves that provide estimates of the phase velocities over a range of angles. From these measurements, the five TI elastic constants can be recovered as the sediment is compacted, without the need for sample unloading, recoring, or reorienting. This paper provides descriptions of the apparatus, the data processing, and an application demonstrating recovery of the evolving TI properties of a compacting marine sediment sample.

54 ENVIRONMENTAL SCIENCES↗

Determining Ductile Fracture Toughness in Metals

Ductile fracture toughness determination, such as the J-integral versus crack growth resistance (J-R) curve, is a useful tool for evaluating material structural integrity in the presence of pre-existing defects. The J-R curve represents a way to calculate the work (energy) per unit fracture surface area needed to drive the crack growth. A typical J-R curve is shown in Fig. 1 from which the material fracture toughness near the initiation of stable crack growth (Jq) can be derived. In addition, tearing modulus (TR), representing the material resistance to stable crack growth, can be calculated based on the slope of the J-R curve between two exclusion lines (red dashed lines in Fig. 1). Since the introduction of the J-R curve, extensive efforts have been continuously devoted to develop simplified and reliable methods for determining the material J-R curve. This article briefly reviews three widely-used J-R curve test methods in metals, i.e. elastic unloading compliance (EUC), normalization, and direct current potential drop (DCPD). The main difference in these methods relates to the determination of the crack size. More details of performing the J-R curve determination can be found in ASTM standard E1820-11.

DCPD↗

Application of Direct Current Potential Drop for the J-integral vs. Crack Growth Resistance Curve Characterization

The direct current potential drop (DCPD) technique has been applied to derive the J-integral vs. crack growth resistance curve (J-R curve) for fracture toughness characterization of structural materials. The test matrix covered three materials including type 316LN stainless steels, Ni-based alloy 617, and one ferritic-martensitic steel, three specimen configurations including standard compact, single edge bending, and disk-shaped compact specimens, and temperatures ranging from 20 C to 650 C. When compared with baseline J-R curves derived from the ASTM normalization method, the original J-R curves from the DCPD technique yielded much smaller Jq values due to the influence of crack blunting, plastic deformation, etc. on potential drop. To counter these effects, a new procedure for adjusting DCPD J-R curves was proposed. After applying the new adjustment procedure, the average difference in Jq between the DCPD technique and the normalization method was only 5.2% and the difference in tearing modulus was 7.4%. The promising result demonstrates the applicability of the DCPD technique for the J-R curve characterization especially in extreme environments, such as elevated temperatures, where the conventional elastic unloading compliance method faces considerable challenges.

DCPD↗

J-R Curve Determination for Disk-shaped Compact Specimens Based on the Normalization Method and Direct Current Potential Drop Technique

Material ductile fracture toughness can be described by J-integral versus crack extension relationship (J-R curve). As a conventional J-R curve measurement method, unloading compliance (UC) becomes impractical in elevated temperature testing due to relaxation of the material and a friction induced back-up shape of the J-R curve. In addition, the UC method may underpredict the crack extension for standard disk-shaped compact (DC(T)) specimens. In order to address these issues, the normalization method and direct current potential drop (DCPD) technique were applied for determining J-R curves at 24 C and 500 C for 0.18T DC(T) specimens made from type 316L stainless steel. For comparison purchase, the UC method was also applied in 24 C tests. The normalization method was able to yield valid J-R curves in all tests. The J-R curves from the DCPD technique need adjustment to account for the potential drop induced by plastic deformation, crack blunting, etc. and after applying a newly-developed DCPD adjustment procedure, the post-adjusted DCPD J-R curves essentially matched J-R curves from the normalization method. In contrast, the UC method underpredicted the crack extension in all tests resulting in substantial deviation in the derived J-R curves manifested by high Jq values than the normalization or DCPD method. Only for tests where the UC method underpredicted the crack extension by a very small value, J-R curves determined by the UC method were similar to those determined by the normalization or DCPD method.

DCPD↗

Application of a Novel DCPD Adjustment Method for the J-R Curve Characterization: A study based on ORNL and ASTM Interlaboratory Results

Material fracture toughness in the fully ductile region can be described by a J-integral vs. crack growth resistance curve (J-R curve). As a conventional J-R curve measurement method, the elastic unloading compliance (EUC) method becomes impractical for elevated temperature testing due to relaxation of the material and friction induced back-up shape of the J-R curve. One alternative solution of J-R curve testing applies the Direct Current Potential Drop (DCPD) technique for measuring crack extension. However, besides crack growth, potential drop can also be influenced by plastic deformation, crack tip blunting, etc., and uncertainties exist in the current DCPD methodology especially in differentiating potential drop due to stable crack growth and due to material deformation. Thus, using DCPD for J-R curve determination remains a challenging task. In this study, a new adjustment procedure for applying DCPD to derive the J-R curve has been developed for conventional fracture toughness specimens, including compact tension, three-point bend, and disk-shaped compact specimens. Data analysis has been performed on Oak Ridge National Laboratory (ORNL) and American Society for Testing and Materials (ASTM) interlaboratory results covering different specimen thicknesses, test temperatures, and materials, to evaluate the applicability of the new DCPD adjustment procedure for J-R curve characterization. After applying the newly-developed procedure, direct comparison between the DCPD method and the normalization method on the same specimens indicated close agreement for the overall J-R curves, as well as the provisional values of fracture toughness near the onset of ductile crack extension, Jq, and of tearing modulus.

DCPD↗

Handling of Highly Radioactive Radiation Sources in a Hot Cell Using a Mechanically Driven Cell Crane - 13452

In 2010, Siempelkamp Nukleartechnik GmbH was awarded the contract for design and erection of a Hot Cell for handling and storage of highly radioactive radiation sources. This Hot Cell is part of a new hot cell laboratory, constructed for the NHZ (Neues Handhabungszentrum = New Handling Center) of the Nuclear Engineering Seibersdorf GmbH (NES). All incurring radioactive materials from Austria are collected in the NHZ, where they are safely conditioned and stored temporarily until their final storage. The main tasks of the NES include, apart from the collection, conditioning and storage of radioactive waste, also the reprocessing and the decontamination of facilities and laboratories originating from 45 years of research and development at the Seibersdorf site as well as the operation of the Hot Cell Laboratory [1]. The new Hot Cell Laboratory inside the NHZ consists of the following room areas: - One hot cell, placed in the center, for remote controlled, radiation protected handling of radioactive materials, including an integrated floor storage for the long-term temporary storage of highly radioactive radiation sources; - An anteroom for the loading and unloading of the hot cell; - One control room for the remote controlling of the hot cell equipment; - One floor storage, placed laterally to the hot cell, for burial, interim storage and removal of fissionable radioactive material in leak-proof packed units in 100 l drums. The specific design activity of the hot cell of 1.85 Pbq relating to 1-Me-Radiator including the integrated floor storage influences realization and design of the components used in the cell significantly. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

D and D of the Callisto PWR Loop as part of the Refurbishment of the BR2 Research Reactor - 16168

Research reactor BR2 is undergoing a thorough maintenance and modernisation operation until mid-2016. In order to be able to use the reactor safely and efficiently in the coming period of 10 years, a preventive replacement of the beryllium matrix was required as a major step in the refurbishment. At the same time, a number of preventive maintenance and modernisation activities have been defined, including the dismantling of the CALLISTO (Capability for Light Water Irradiation in Steady State and Transient Operation) PWR experimental facility for in-pile studies installed into BR2 for more than 20 years. The CALLISTO end of life decommissioning strategy aims for waste, cost and dose uptake minimisation and includes: - the unloading and removal of the in-pile sections; - a closed-loop full system decontamination for dose reduction; - the complete dismantling of the loop; - the further sorting and segmentation in a dedicated workshop; - a hard chemical batch-wise decontamination for unconditional clearance. The operation is planned in the period of mid-2015 until mid-2016. The paper will describe in detail these subsequent steps, with a focus on decontamination and dismantling. Lessons learned and potential benefits towards the D and D of commercial PWR will be highlighted. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The SD-20K, a large Type B(U)F Package for Waste Containers - 18181

The type B(U)F package SD-20K, currently being developed by DAHER Nuclear Technologies GmbH (DNT), will facilitate the transport of legacy waste from interim storage facilities to the German final repository Konrad. The package SD-20K could also be used in other cases where legacy packages are not fit for a final repository and/or for transport but could be easily conditioned into a suitable package. Since the 1990's German utilities, reactor operators and service providers conditioned waste according to the requirements of the preliminary acceptance criteria for the final repository Konrad. Some of this waste was conditioned in containers which were at that time licensed as type B packages but for which the license expired due to various reasons. Other waste was reclassified so that the used package type does no longer comply with the content. In recent times Konrad containers of type IP-2 are loaded with e. g. core components in compliance with the Konrad acceptance criteria but overloaded with respect to the transport regulations. DAHER Nuclear Technologies GmbH (DNT) in cooperation with Siemens AG investigated possible solutions in a general approach. The result of the evaluation was that the best solution for the transport problem was to develop a versatile type B(U)F package large enough to accommodate all containers and packages accepted for the final repository Konrad. Possible solutions like repacking (high costs and high dose exposure) or requalification (high costs and risk of failure to achieve the goal) were not considered to be generally applicable. The SD-20K packaging is currently designed to accommodate Konrad Containers type III, IV and VI; however, the dimensions of its cavity are sufficient to accommodate any container and package that meets the acceptance criteria for the final repository Konrad. The SD-20K packaging consists of an inner container which constitutes the containment, surrounded by a rather large shock absorbing structure which also contains the thermal protection system. The outer shape of the SD-20K resembles a 20' ISO container. A special feature of the SD-20K is the automatic unloading system to minimize dose exposure of the personnel in the final repository. After arrival in the repository the shock absorbing structure as well as the door of the containment system are opened automatically and the content is moved out of the SD-20K by a remote-controlled carrier system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Update on Plans for Treatment of Research Reactor Used Fuels at La Hague - 19507

Over the past decades, Orano (formerly AREVA) has been transporting, unloading, storing, and reprocessing research reactor spent fuel (RRSF) in its French facilities and with its equipment. This experience has resulted in the transportation and industrial-scale reprocessing of over 23 tons of RRSF (mainly of the Al type) at Orano's facilities in France, both in the Marcoule and the La Hague plants. In order to meet its customers growing needs in terms of RRSF management, Orano is developing new RRSF reprocessing capacities for the La Hague UP2-800 facility utilizing the lessons learned from the reprocessing of the current RRSF. This new facility is called the Traitement des Combustibles Particuliers or TCP and was introduced last year. The TCP is planned to reprocess several types of RRSF, including both Al and U{sub 3}Si{sub 2} RRSF, and in the future may also be useful in the support of reprocessing LWR and fast reactor MOX fuels. The focus of the TCP is on developing shearing and dissolution processes for these fuel types that can be incorporated into, and operated along with, the existing La Hague facilities. This paper will cover each of the stages of the current reprocessing of RRSF at La Hague from its transportation to La Hague to its post-reprocessing vitrified waste production, provide an update on its status, and identifying the areas where the TCP will better facilitate the reprocessing of the RRSF. Ultimately, this paper illustrates the innovative solutions available to modify existing recycling/reprocessing facilities to address pseudo-unique used nuclear fuel (UNF) forms to improve/simplify back-end UNF management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Research on reconstruction method for pebble-detecting CT system for PB-HTGR - 186633

In the pebble-bed high temperature gas-cooled reactor (PB-HTGR), pebble dynamics in the reactor is important for safe operation. However, the experimental research at present were mostly implemented in two-dimensional models or limited to phenomenological methods. To investigate pebble dynamics using a three-dimensional experimental method, we designed a platform with a pebble-detecting CT system exactly as the proportion of 1:5 with the actual HTR-PM. Multi-slice helical CT can provide cross-sectional images of fuel pebbles at any place during motion, allowing for pebble trajectories to be obtained during the whole unloading process. The purpose of this paper is to design appropriate algorithms to reconstruct cross-sectional images of pebbles for the system. Two methods applicable to distinct situations were discussed and compared. Based on this, a fast reconstruction method was introduced and proved to be the most suitable solution for the system to get pebble trajectories rapidly. The pebble-detecting principle and the effectiveness of the fast reconstruction method were demonstrated by a verification experiment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Injection-Induced Micro-Earthquakes in a Geothermal Steam Reservoir, The Geysers Geothermal Field, California

In this study we analyze relative contributions to the cause and mechanism of injection-induced micro-earthquakes (MEQs) at The Geysers geothermal field, California. We estimated the potential for inducing seismicity by coupled thermal-hydrological-mechanical analysis of the geothermal steam production and cold water injection to calculate changes in stress (in time and space) and investigated if those changes could induce a rock mechanical failure and associated MEQs. An important aspect of the analysis is the concept of a rock mass that is critically stressed for shear failure. This means that shear stress in the region is near the rock-mass frictional strength, and therefore very small perturbations of the stress field can trigger an MEQ. Our analysis shows that the most important cause for injection-induced MEQs at The Geysers is cooling and associated thermal-elastic shrinkage of the rock around the injected fluid that changes the stress state in such a way that mechanical failure and seismicity can be induced. Specifically, the cooling shrinkage results in unloading and associated loss of shear strength in critically shear-stressed fractures, which are then reactivated. Thus, our analysis shows that cooling-induced shear slip along fractures is the dominant mechanism of injection-induced MEQs at The Geysers.

54 ENVIRONMENTAL SCIENCES↗

METHODS FOR RECONSTRUCTION OF RADIONUCLIDE COMPOSITION AND ACTIVITY OF FISSION PRODUCTS ACCUMULATED IN THE IRRADIATED URANIUM AT THE MOMENT OF ITS RADIOCHEMICAL REPROCESSING AT PLANT “B”, “MAYAK” PA IN THE EARLY 1950s

The article describes calculation procedure for reconstruction of radionuclide composition and activity of fission fragments accumulated in the irridated uranium from “Mayak” PA graphite-uranium reactors at the moment, when irradiation is completed, and at the moment, when the uranium is transferred to radiochemical processing (plant B) in the early 1950s. The procedure includes a reactor model and a cooling pool model. It is based on archive data on monthly uranium unloading and loading in the reactor and in the cooling pool of each reactor. The objects of reconstruction include: order of reloading of uranium versus its location radius in the reactor core; duration of irradiation and radionuclide composition of fission fragments for each radius; order of uranium removal from the cooling pool; effective time of uranium storage in the pool; radionuclide composition and activity of fission fragments in the irradiated uranium delivered to radiochemical reprocessing daily and on average for each month. The model is intended for use in reconstruction of parameters of radionuclide release source into the atmosphere and the source of liquid radioactive waste generation at the “Mayak” PA radiochemical plant.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compaction localization and constitutive behavior of weak porous sandstone.

A combined experimental and constitutive modeling program for weak porous sandstone deformation is described. A series of axisymmetric compression tests were performed over a range of mean stresses to study dilatational, compactional and transitional regimes. Experimental results were used both to derive constitutive parameters for testing localization theory and to parameterize a poroelastic-plastic model. Observed strain localization, imaged syn-deformationally using acoustic emissions, includes high- and low-angle shear and low angle compactional features or 'bands'. Isotropic elastic moduli measured via unloading loops show a progressive degradation pre-failure as decreasing functions of work-conjugate plastic strains and increasing functions of stress magnitude. The degradation pathway is unique for samples which underwent localization versus those that underwent spatially pervasive pore collapse. Total shear and volume strains are partitioned into elastic and plastic portions including the ''coupling'' strain associated with modulus degradation. Plastic strain calculated with and without the coupling term is compared with regard to localization predictions. Both coupled and uncoupled cases predict high angle shear bands for uniaxial and low mean stress conditions on the dilatational side of the yield surface. Uncoupled predictions show progressively lower angle shear bands approaching the transitional regime (stress conditions approaching the 'cap' surface). When elastic-plastic coupling is accounted for, compaction bands are predicted for the transitional regime, as are observed in the experiments. Finite element modeling efforts are described using a 3-invariant, mixed-hardening, continuous yield surface, elasto-plasticity model that includes several features important for porous sandstone constitutive behavior and observed experimentally, including non-associativity, nonlinear elasticity, elastic-plastic coupling, and kinematic hardening. Modeled deformational behavior attending stress paths relevant for several reservoir production scenarios are described.

02 PETROLEUM↗