Novel Human Radiation Exposure Biomarker Panel Applicable for Population Triage

Purpose: To identify a panel of radiation-responsive plasma proteins that could be used in a point-of-care biologic dosimeter to detect clinically significant levels of ionizing radiation exposure. Methods and Materials: Patients undergoing preparation for hematopoietic cell transplantation using radiation therapy (RT) with either total lymphoid irradiation or fractionated total body irradiation were eligible. Plasma was examined from patients with potentially confounding conditions and from normal individuals. Each plasma sample was analyzed for a panel of 17 proteins before RT was begun and at several time points after RT exposure. Paired and unpaired t tests between the dose and control groups were performed. Conditional inference trees were constructed based on panels of proteins to compare the non-RT group with the RT group. Results: A total of 151 patients (62 RT, 41 infection, 48 trauma) were enrolled on the study, and the plasma from an additional 24 healthy control individuals was analyzed. In comparison with to control individuals, tenascin-C was upregulated and clusterin was downregulated in patients receiving RT. Salivary amylase was strongly radiation responsive, with upregulation in total body irradiation patients and slight downregulation in total lymphoid irradiation patients compared with control individuals. A panel consisting of these 3 proteins accurately distinguished between irradiated patients and healthy control individuals within 3 days after exposure: 97% accuracy, 0.5% false negative rate, 2% false positive rate. The accuracy was diminished when patients with trauma, infection, or both were included (accuracy, 74%-84%; false positive rate, 14%-33%, false negative rate: 8%-40%). Conclusions: A panel of 3 proteins accurately distinguishes unirradiated healthy donors from those exposed to RT (0.8-9.6 Gy) within 3 days of exposure. These findings have significant implications in terms of triaging individuals in the case of nuclear or other radiologic events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mean Absorbed Dose to the Anal-Sphincter Region and Fecal Leakage among Irradiated Prostate Cancer Survivors

Purpose: To supplement previous findings that the absorbed dose of ionizing radiation to the anal sphincter or lower rectum affects the occurrence of fecal leakage among irradiated prostate-cancer survivors. We also wanted to determine whether anatomically defining the anal-sphincter region as the organ at risk could increase the degree of evidence underlying clinical guidelines for restriction doses to eliminate this excess risk. Methods and Materials: We identified 985 men irradiated for prostate cancer between 1993 and 2006. In 2008, we assessed long-term gastrointestinal symptoms among these men using a study-specific questionnaire. We restrict the analysis to the 414 men who had been treated with external beam radiation therapy only (no brachytherapy) to a total dose of 70 Gy in 2-Gy daily fractions to the prostate or postoperative prostatic region. On reconstructed original radiation therapy dose plans, we delineated the anal-sphincter region as an organ at risk. Results: We found that the prevalence of long-term fecal leakage at least once per month was strongly correlated with the mean dose to the anal-sphincter region. Examining different dose intervals, we found a large increase at 40 Gy; {>=}40 Gy compared with <40 Gy gave a prevalence ratio of 3.8 (95% confidence interval 1.6-8.6). Conclusions: This long-term study shows that mean absorbed dose to the anal-sphincter region is associated with the occurrence of long-term fecal leakage among irradiated prostate-cancer survivors; delineating the anal-sphincter region separately from the rectum and applying a restriction of a mean dose <40 Gy will, according to our data, reduce the risk considerably.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray ablation of hyaluronan hydrogels: Fabrication of three-dimensional microchannel networks

We present a simple and highly versatile protocol for polymer ablation: hard x-ray irradiation makes it possible to rapidly depolymerize hyaluronan hydrogels and fabricate three-dimensional network of microchannels. Photodynamic and photochemical analyses show that x-ray irradiation directly cleaves the polymer backbone and the total dose controls the degradation kinetics. This nonthermal ablation protocol may offer opportunities for processing organic polymers and biological materials.

36 MATERIALS SCIENCE↗

The management of imaging dose during image-guided radiotherapy: Report of the AAPM Task Group 75

Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Although widely varied in modality and method, all radiographic guidance techniques have one thing in common--they can give a significant radiation dose to the patient. As with all medical uses of ionizing radiation, the general view is that this exposure should be carefully managed. The philosophy for dose management adopted by the diagnostic imaging community is summarized by the acronym ALARA, i.e., as low as reasonably achievable. But unlike the general situation with diagnostic imaging and image-guided surgery, image-guided radiotherapy (IGRT) adds the imaging dose to an already high level of therapeutic radiation. There is furthermore an interplay between increased imaging and improved therapeutic dose conformity that suggests the possibility of optimizing rather than simply minimizing the imaging dose. For this reason, the management of imaging dose during radiotherapy is a different problem than its management during routine diagnostic or image-guided surgical procedures. The imaging dose received as part of a radiotherapy treatment has long been regarded as negligible and thus has been quantified in a fairly loose manner. On the other hand, radiation oncologists examine the therapy dose distribution in minute detail. The introduction of more intensive imaging procedures for IGRT now obligates the clinician to evaluate therapeutic and imaging doses in a more balanced manner. This task group is charged with addressing the issue of radiation dose delivered via image guidance techniques during radiotherapy. The group has developed this charge into three objectives: (1) Compile an overview of image-guidance techniques and their associated radiation dose levels, to provide the clinician using a particular set of image guidance techniques with enough data to estimate the total diagnostic dose for a specific treatment scenario (2) identify ways to reduce the total imaging dose without sacrificing essential imaging information, and (3) recommend optimization strategies to trade off imaging dose with improvements in therapeutic dose delivery. The end goal is to enable the design of image guidance regimens that are as effective and efficient as possible.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of the secondary electrons produced by proton and electron beams in water

The secondary electrons produced in water by electron and proton beams are compared with each other. The total ionization cross section (TICS) for an electron impact in water is obtained by using the binary-encounter-Bethe model. Hence, an empirical equation based on two adjustable fitting parameters is presented to determine the TICS for proton impact in media. In order to calculate the projectile trajectory, a set of stochastic differential equations based on the inelastic collision, elastic scattering, and bremsstrahlung emission are used. In accordance with the projectile trajectory, the depth dose deposition, electron energy loss distribution in a certain depth, and secondary electrons produced in water are calculated. The obtained results for the depth dose deposition and energy loss distribution in certain depth for electron and proton beams with various incident energies in media are in excellent agreement with the reported experimental data. The difference between the profiles for the depth dose deposition and production of secondary electrons for a proton beam can be ignored approximately. But, these profiles for an electron beam are completely different due to the effect of elastic scattering on electron trajectory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Selective Shielding Bone Marrow: An Approach to Create Personal Protective Equipment for Gamma Radiation

Many casualties of the Hiroshima and Nagasaki atomic bombs, and many of the firefighters who first responded to the Chernobyl nuclear power plant accident, became ill with acute radiation syndrome (ARS). Most of the people who do not recover from ARS will die within a few weeks to a few months after exposure, with the primary cause of death being the destruction of the body's bone marrow (BM). This is exemplified by the Chernobyl firefighters, the majority of whom received whole body doses between 0.8 and 10 Gy, and the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) final report on the disaster concluded that the underlying cause of death of all 28 firefighters who succumbed to ARS was from bone marrow failure. BM is comprised of hematopoietic stem cells (HSCs) which are responsible for the constant renewal of blood cells. Due to their high rate of proliferation, HSCs are especially vulnerable to ionizing radiation, but are endowed with remarkable regenerative potential. Owing to their central role in blood production, lethal irradiation of HSCs leads to death from severe anemia, infection and internal bleeding. This relationship between high doses of radiation and HSC apoptosis has led to the use of HSC transplantation as a life-saving intervention in cases of acute exposure. This is demonstrable in medical practice, where thousands of individuals have undergone supra-lethal Total Body Irradiation (TBI) for purposes of cancer therapy, and were rescued by well-matched BM transplantation. Indeed, life-threatening damage may be reversed by BM transplantation in individuals receiving doses of radiation of up to 10 Gy. At doses > 10 Gy, damage to gastrointestinal (GI) tissue may become a limiting factor in survival. Remarkably, in the common procedure of BM transplantation, the number of HSCs extracted from a single active BM site containing less than 5% of the donor's BM tissue is sufficient to support the complete reconstitution of the HSC compartment in a lethally irradiated recipient. This capacity of BM to expand and replenish is due to the high regenerative potential of the HSCs it harbors. In contrast to mature blood cells, which are dispersed throughout the body, HSCs are confined to the bones, allowing for effective targeted shielding. This has been confirmed in several animal models, where sparing the HSC-rich area of a subject receiving otherwise full-body irradiation is sufficient to support hematopoietic functions and allow survival. Approximately 48% of the human body's active BM is contained within the lumbar vertebrae and the pelvic region. This high concentration of BM makes the pelvic region an ideal area to shield for preventing the serious hematopoietic effects of radiation exposure. Stem-cell rich tissues like active BM are also more sensitive to the stochastic effects (i.e. cancer) of radiation exposure. The high amount of BM in the pelvic region, combined with the presence of the sensitive gastrointestinal system and female gonads in this same area of the body allows for the possibility of significantly reducing stochastic effects of radiation by limiting radiation exposure to this vital area. Thus, shielding this region holds great promise for both acute and protracted exposures. Thus, a specialized radiation shielding device for the protection of active BM concentrations is presented here. This belt-like selective shielding device focuses on the protection of BM that is present in the pelvis and hip bones, protecting the medullary volume from which BM is commonly extracted for transplantation (i.e. the iliac bones) while allowing relatively unhindered movement of the wearer. In order to optimize the use of shielding materials towards the protection of active BM, the shielding uniquely brings into account the natural shielding properties of human tissue, with thickness being inversely related to the thickness and radiation attenuation of the underlying tissue at each point surrounding the area being protected. The findings resulting from both experimental and simulation testing of this selective shielding device are presented here.

61 RADIATION PROTECTION AND DOSIMETRY↗

Validation of a pretreatment delivery quality assurance method for the CyberKnife Synchrony system

Purpose: To evaluate the geometric and dosimetric accuracies of the CyberKnife Synchrony respiratory tracking system (RTS) and to validate a method for pretreatment patient-specific delivery quality assurance (DQA). Methods: An EasyCube phantom was mounted on the ExacTrac gating phantom, which can move along the superior–inferior (SI) axis of a patient to simulate a moving target. The authors compared dynamic and static measurements. For each case, a Gafchromic EBT3 film was positioned between two slabs of the EasyCube, while a PinPoint ionization chamber was placed in the appropriate space. There were three steps to their evaluation: (1) the field size, the penumbra, and the symmetry of six secondary collimators were measured along the two main orthogonal axes. Dynamic measurements with deliberately simulated errors were also taken. (2) The delivered dose distributions (from step 1) were compared with the planned ones, using the gamma analysis method. The local gamma passing rates were evaluated using three acceptance criteria: 3% local dose difference (LDD)/3 mm, 2%LDD/2 mm, and 3%LDD/1 mm. (3) The DQA plans for six clinical patients were irradiated in different dynamic conditions, to give a total of 19 cases. The measured and planned dose distributions were evaluated with the same gamma-index criteria used in step 2 and the measured chamber doses were compared with the planned mean doses in the sensitive volume of the chamber. Results: (1) A very slight enlargement of the field size and of the penumbra was observed in the SI direction (on average <1 mm), in line with the overall average CyberKnife system error for tracking treatments. (2) Comparison between the planned and the correctly delivered dose distributions confirmed the dosimetric accuracy of the RTS for simple plans. The multicriteria gamma analysis was able to detect the simulated errors, proving the robustness of their method of analysis. (3) All of the DQA clinical plans passed the tests, both in static and dynamic conditions. No statistically significant differences were found between static and dynamic cases, confirming the high degree of accuracy of the Synchrony RTS. Conclusions: The presented methods and measurements verified the mechanical and dosimetric accuracy of the Synchrony RTS. Their method confirms the fact that the RTS, if used properly, is able to treat a moving target with great precision. By combining PinPoint ion chamber, EBT3 films, and gamma evaluation of dose distributions, their DQA method robustly validated the effectiveness of CyberKnife and Synchrony system.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-05: Non-Invasive in Vivo Biodosimetry in Radiotherapy Patients Using Electron Paramagnetic Resonance (EPR) Spectroscopy

Purpose: Medical intervention following a major, unplanned radiation event can elevate the human whole body exposure LD50 from 3 to 7 Gy. On a large scale, intervention cannot be achieved effectively without accurate and efficient triage. Current methods of retrospective biodosimetry are restricted in capability and applicability; published human data is limited. We aim to further develop, validate, and optimize an automated field-deployable in vivo electron paramagnetic resonance (EPR) instrument that can fill this need. Methods: Ionizing radiation creates highly-stable, carbonate-based free radicals within tooth enamel. Using a process similar to nuclear magnetic resonance, EPR directly measures the presence of radiation-induced free radicals. We performed baseline EPR measurements on one of the upper central incisors of total body irradiation (TBI) and head and neck (H&N) radiotherapy patients before their first treatment. Additional measurements were performed between subsequent fractions to examine the EPR response with increasing radiation dose. Independent dosimetry measurements were performed with optically-stimulated luminescent dosimeters (OSLDs) and diodes to more accurately establish the relationship between EPR signal and delivered radiation dose. Results: 36 EPR measurements were performed over the course of four months on two TBI and four H & N radiotherapy patients. We observe a linear increase in EPR signal with increasing dose across the entirety of the tested range. A linear least squares-weighted fit of delivered dose versus measured signal amplitude yields an adjusted R-square of 0.966. The standard error of inverse prediction (SEIP) is 1.77 Gy. For doses up to 7 Gy, the range most relevant to triage, we calculate an SEIP of 1.29 Gy. Conclusion: EPR spectroscopy provides a promising method of retrospective, non-invasive, in vivo biodosimetry. Our preliminary data show an excellent correlation between predicted signal amplitude and delivered dose. With further development, a robust means of predicting delivered radiation dose from EPR measurements is expected. This project was funded by the Biomedical Advanced Research and Development Authority (BARDA) within the U.S. Department of Health and Human Services subcontracted through the Geisel School of Medicine at Dartmouth and by the Dartmouth Physically-Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR) Pilot Program.

60 APPLIED LIFE SCIENCES↗

Reduction of Eu{sup 3+} to Eu{sup 2+} in aluminoborosilicate glasses under ionizing radiation

Eu{sub 2}O{sub 3}-doped aluminoborosilicate glasses were prepared by melting in air at high temperature ({approx}1500 {sup o}C). It was shown by luminescence and Electron Paramagnetic Resonance (EPR) measurements that both Eu{sup 3+} and Eu{sup 2+} ions can exist simultaneously in the glass matrix studied after glass synthesis as well as after exposure to ionizing radiation. Increase of total Eu{sub 2}O{sub 3} concentration leads to the increase of Eu{sup 3+} luminescence intensity while the luminescence intensity of Eu{sup 2+} ions tends to decrease. In contrast the EPR indicates that the amount of Eu{sup 2+} ions in the glass increases with total Eu{sub 2}O{sub 3} concentration. The difference in the results of the two spectroscopies is explained in terms of energy transfer from Eu{sup 2+} to Eu{sup 3+} leading to an Eu{sup 2+} luminescence quenching. Irradiation results in the increase of reduced Eu{sup 2+} quantity detected by EPR measurements. It was shown that Eu{sup 2+} ions are located in both high (g {approx} 4.6) and low symmetry ('U' spectrum) sites in the structure of aluminoborosilicate glasses. The increase of Eu{sup 2+} content by the increase of the irradiation dose manifests the strong reduction process Eu{sup 3+} {yields} Eu{sup 2+}.

36 MATERIALS SCIENCE↗

Effects of ionizing radiation on CCD's

The effects of 1.2 MeV gamma radiation and 20 MeV electrons on the operational characteristics of CCDs are studied. The effects of ionizing radiation on the charge transfer efficiency, dark current, and input/output circuitry are described. The improved radiation hardness of buried channel CCDs is compared to surface channel results. Both ion implanted and epitaxial layer buried channel device results are included. The advantages of using a single thickness SiO2 gate dielectric are described. The threshold voltage shifts and surface state density changes of dry, steam, and HCl doped oxides are discussed. Recent results on the recovery times and total dose effects of high dose rate pulses of 20 MeV electrons are reported.

Hartsell, G. A.↗

Long-term low-dose α-particle enhanced the potential of malignant transformation in human bronchial epithelial cells through MAPK/Akt pathway

Highlights: • Multi-exposures of 25 mGy α-ray enhanced cell proliferation, adhesion, and invasion. • MAPK/Akt but not JNK/P66 was positively correlated with cell invasive phenotypes. • LDR of α-irradiation triggers cell malignant transformation through MAPK/Akt. - Abstract: Since the wide usage of ionizing radiation, the cancer risk of low dose radiation (LDR) (<0.1 Gy) has become attractive for a long time. However, most results are derived from epidemiologic studies on atomic-bomb survivors and nuclear accidents surrounding population, and the molecular mechanism of this risk is elusive. To explore the potential of a long-term LDR-induced malignant transformation, human bronchial epithelial cells Beas-2B were fractionally irradiated with 0.025 Gy α-particles for 8 times in total and then further cultured for 1–2 months. It was found that the cell proliferation, the abilities of adhesion and invasion, and the protein expressions of p-ERK, p-Akt, especially p-P38 were not only increased in the multiply-irradiated cells but also in their offspring 1–2 months after the final exposure, indicating high potentiality of cell malignant transformation. On opposite, the expressions of p-JNK and p-P66 were diminished in the subcultures of irradiated cells and thus may play a role of negative regulation in canceration. When the cells were transferred with p38 siRNA, the LDR-induced enhancements of cell adhesion and invasion were significantly reduced. These findings suggest that long-term LDR of α-particles could enhance the potential of malignant transformation incidence in human bronchial epithelial cells through MAPK/Akt pathway.

60 APPLIED LIFE SCIENCES↗

Low Energy Ionizing Radiation and Plasma Contributions to Radiation Dose in Materials at Sun-Earth Lagrange Points

- High energy radiation environments responsible for radiation damage to thick materials are well characterized and modeled: - Galactic cosmic rays — Badhwar-O’Neil 2020, CREME96, Nymmik - Solar particle events — Emission of Solar Protons, SAPPHIRE, JPL, King 1972 - Trapped radiation belts — AE8/AP8, AE9/AP9/IRENE - Low energy radiation environments responsible for radiation damage to thin materials relevant to Lagrange points and interplanetary missions have not been treated as comprehensively to date: - Solar wind - Magnetosheath - Magnetotail - Concern to spacecraft design and operations is radiation damage to surfaces and thin materials with mission critical applications on exterior of spacecraft - Applications: thermal control coatings, sunshields, multilayer insulation, optical thin film coatings, solar sails, thermo-optical properties of space exposed materials - Damage processes: radiation degradation (total dose), light ion sputtering, proton blistering of soft metals, modification of optical properties (α/ε), modification of charging properties (SEY, surface conductivity)

Joseph I. Minow↗

Assessment of out-of-field absorbed dose and equivalent dose in proton fields

Purpose: In proton therapy, as in other forms of radiation therapy, scattered and secondary particles produce undesired dose outside the target volume that may increase the risk of radiation-induced secondary cancer and interact with electronic devices in the treatment room. The authors implement a Monte Carlo model of this dose deposited outside passively scattered fields and compare it to measurements, determine the out-of-field equivalent dose, and estimate the change in the dose if the same target volumes were treated with an active beam scanning technique. Methods: Measurements are done with a thimble ionization chamber and the Wellhofer MatriXX detector inside a Lucite phantom with field configurations based on the treatment of prostate cancer and medulloblastoma. The authors use a GEANT4 Monte Carlo simulation, demonstrated to agree well with measurements inside the primary field, to simulate fields delivered in the measurements. The partial contributions to the dose are separated in the simulation by particle type and origin. Results: The agreement between experiment and simulation in the out-of-field absorbed dose is within 30% at 10-20 cm from the field edge and 90% of the data agrees within 2 standard deviations. In passive scattering, the neutron contribution to the total dose dominates in the region downstream of the Bragg peak (65%-80% due to internally produced neutrons) and inside the phantom at distances more than 10-15 cm from the field edge. The equivalent doses using 10 for the neutron weighting factor at the entrance to the phantom and at 20 cm from the field edge are 2.2 and 2.6 mSv/Gy for the prostate cancer and cranial medulloblastoma fields, respectively. The equivalent dose at 15-20 cm from the field edge decreases with depth in passive scattering and increases with depth in active scanning. Therefore, active scanning has smaller out-of-field equivalent dose by factors of 30-45 in the entrance region and this factor decreases with depth. Conclusions: The dose deposited immediately downstream of the primary field, in these cases, is dominated by internally produced neutrons; therefore, scattered and scanned fields may have similar risk of second cancer in this region. The authors confirm that there is a reduction in the out-of-field dose in active scanning but the effect decreases with depth. GEANT4 is suitable for simulating the dose deposited outside the primary field. The agreement with measurements is comparable to or better than the agreement reported for other implementations of Monte Carlo models. Depending on the position, the absorbed dose outside the primary field is dominated by contributions from primary protons that may or may not have scattered in the brass collimating devices. This is noteworthy as the quality factor of the low LET protons is well known and the relative dose risk in this region can thus be assessed accurately.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-I-79: Validation of a Monte Carlo Radiographic Simulation

Purpose: To validate a radiographic simulation in order to estimate patient dose due to clinically-used radiography protocols. Methods: A Monte Carlo simulation was created to simulate a radiographic x-ray beam using GEANT4. Initial validation was performed according to a portion of TG 195. Computational NURBS-based phantoms were used simulate patients of varying ages and sizes. The deposited energy in the phantom is output by the simulation. The exposure in air from a clinically used radiography unit was measured at 100 cm for various tube potentials. 10 million photons were simulated with 1 cubic centimeter of air located 100 cm from the source, and the total absorbed dose was noted. The normalization factor was determined by taking a ratio of the measured dose in air to the simulated dose in air. Dose to individual voxels is calculated using the energy deposition map along with the voxelized and segmented phantom and the normalization factor. Finally, the effective dose is calculated using the ICRP methodology and tissue weighting factors. Results: This radiography simulation allows for the calculation and visualization of the energy deposition map within a voxelized phantom. The ratio of exposure, measured using an ionization chamber, to air in the simulation was determined. Since the simulation output is calibrated to match the exposure of a given clinical radiographic x-ray tube, the dose map may be visualized. This will also allow for absorbed dose estimation in specific organs or tissues as well as a whole body effective dose estimation. Conclusion: This work indicates that our Monte Carlo simulation may be used to estimate the radiation dose from clinical radiographic protocols. This will allow for an estimate of radiographic dose from various examinations without the use of traditional methods such as thermoluminescent dosimeters and body phantoms.

60 APPLIED LIFE SCIENCES↗

Education and training in the field of nuclear instrumentation and measurement: CEA/INSTN (National Institute for Nuclear Sciences and Technologies) strategy to improve and develop new pedagogical tools and methods

Part of the French Alternative Energies and Atomic Energy Commission (CEA), the National Institute for Nuclear Science and Technology (INSTN) is a higher education institution whose mission is to provide students and professionals a high level of scientific and technological qualification in all disciplines related to nuclear energy applications. In this frame, INSTN carries out education and training (E and T) programs in nuclear instrumentation and radioprotection. Its strategy has always been to complete theoretical courses by training courses and laboratory works carried out on an extensive range of training tools that includes a large panel of nuclear instrumentation as well as software applications. Since its creation in 1956, the INSTN has conducted both education and vocational programs on ionizing radiation detection. An extensive range of techniques have commonly been used during practical works with students and employees of companies who need to get the knowledge and specialization in this field. Today, the INSTN is mainly equipped with usual detectors and electronics in large numbers in order to be able to accommodate up to 48 trainees at the same time in two classrooms, with only two trainees for one workstation in order to optimize their learning. In the field of the neutron detection systems, the INSTN has strongly developed its offer taking advantage of the use of research reactors, such as ISIS reactor (700 kW) at Saclay. The implementation of neutron detection systems specific to the courses offers a unique way of observing and analysing the signal coming from neutron detectors, as well as learning how to set the parameters of the detection system in real conditions. Providing the trainees with an extensive overview of each part of the neutron monitoring instrumentation apply to a nuclear reactor, hands-on measurements on the ISIS reactor play a major role in ensuring a practical and comprehensive understanding of the neutron detection system and their integration in the safety system of nuclear reactors. It also gives a solid background for the follow up and the development of the neutron detection systems. Another field of activity of the INSTN is the development of new teaching tools using software applications. We describe hereafter two applications that have recently been developed by the institute, O.S.I.R.I.S and DOSIMEX. The INSTN and the company OREKA have developed an innovative teaching tool named O.S.I.R.I.S. The tool is built on a virtual 3D environment in which users operate in a totally free way. The action is located in a pressurised water reactor in the environment of a steam generator building. The users are students or professionals who want to learn and train on concrete situations on how to protect the workers against radiation. Through the use of this serious game, users must: establish a predictive dose evaluation, implement the principles of radiation protection, perform the dose result of the operation, analyse the gap between the predictive collective dose and the collective dose achieved, and decide about the lessons to provide feedback. Taking into account the increasing constraints related to radiation protection, it is essential to use computer codes to evaluate the dose rates generated by sources of ionizing radiation. Many powerful codes exist but are often relatively complex to implement and are dedicated to experts. In addition, these codes are often 'black boxes' that does not allow the user to understand the underlying physics. The objective of DOSIMEX codes developed by the INSTN is to give, by the means of a VBA code with a simple interface, the ability to easily conduct a wide range of radiological exposure situations: calculation of gamma, beta, neutron equivalent dose rate, calculation of internal contamination and atmospheric transfer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetry of Small Circular Fields for 6-MeV Electron Beams

Small field electron beams used in the clinic present complex dosimetry. This investigation reports dosimetric characteristics of small 6-MeV electron field measurements and Monte Carlo calculations, and examines their impact on patient dosimetry. Radiographic film and ionization chamber were used for dosimetric measurements for a 6-MeV electron beam from a Varian 21EX linac. A set of circular cerrobend cutouts with diameters ranging from 2 to 3.0 cm was made. A clinical Monte Carlo algorithm was used to calculate dosimetric parameters. As the cutout diameter decreased, the build-up portion of the percentage depth dose (PDD) curves shifted toward the phantom surface, the depth of maximum dose, d{sub max,} decreased from 1.2 cm to 0.6 cm, but the practical range, R{sub p}, remained constant at about 3.1 cm. The absorbed dose rate, D{sub r}, decreased linearly with decreasing diameter. Profile coverage ratios CR (ie, the ratio of a given isodose line to the cutout diameter) at d{sub max}, for 90% and 80%, CR{sub 90}, CR{sub 80}, are approximately 55% and 73%, respectively. As the cutout diameter decreased, the 90% to 10% penumbra to diameter ratio, PR, increased from 0.49 to 0.56 for 3- to 2-cm cutouts. The total 90% to 10% penumbra was about the same size as the cutout diameter. The measured output factors were in good agreement with Monte Carlo calculation within 2.2%. Accurate small electron field measurements were performed using parallel plate ion chamber and film. The data were well supported by Monte Carlo calculations. These data facilitate routine clinical treatments for small cutouts as d{sub max}, D{sub r}, and other data can be quickly obtained instead of performing labor-intensive individual patient measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of joint kinematics using a conventional clinical single-perspective flat-panel radiography system

Purpose: The ability to accurately measure joint kinematics is an important tool in studying both normal joint function and pathologies associated with injury and disease. The purpose of this study is to evaluate the efficacy, accuracy, precision, and clinical safety of measuring 3D joint motion using a conventional flat-panel radiography system prior to its application in an in vivo study. Methods: An automated, image-based tracking algorithm was implemented to measure the three-dimensional pose of a sparse object from a two-dimensional radiographic projection. The algorithm was tested to determine its efficiency and failure rate, defined as the number of image frames where automated tracking failed, or required user intervention. The accuracy and precision of measuring three-dimensional motion were assessed using a robotic controlled, tibiofemoral knee phantom programmed to mimic a subject with a total knee replacement performing a stair ascent activity. Accuracy was assessed by comparing the measurements of the single-plane radiographic tracking technique to those of an optical tracking system, and quantified by the measurement discrepancy between the two systems using the Bland-Altman technique. Precision was assessed through a series of repeated measurements of the tibiofemoral kinematics, and was quantified using the across-trial deviations of the repeated kinematic measurements. The safety of the imaging procedure was assessed by measuring the effective dose of ionizing radiation associated with the x-ray exposures, and analyzing its relative risk to a human subject. Results: The automated tracking algorithm displayed a failure rate of 2% and achieved an average computational throughput of 8 image frames/s. Mean differences between the radiographic and optical measurements for translations and rotations were less than 0.08 mm and 0.07 Degree-Sign in-plane, and 0.24 mm and 0.6 Degree-Sign out-of-plane. The repeatability of kinematics measurements performed using the radiographic tracking technique was better than {+-}0.09 mm and 0.12 Degree-Sign in-plane, and {+-}0.70 mm and {+-}0.07 Degree-Sign out-of-plane. The effective dose associated with the imaging protocol used was 15 {mu}Sv for 10 s of radiographic cine acquisition. Conclusions: This study demonstrates the ability to accurately measure knee-joint kinematics using a single-plane radiographic measurement technique. The measurement technique can be easily implemented at most clinical centers equipped with a modern-day radiographic x-ray system. The dose of ionizing radiation associated with the image acquisition represents a minimal risk to any subjects undergoing the examination.

60 APPLIED LIFE SCIENCES↗

World History Of Radon Research And Measurement From The Early 1900's To Today

In 1900, Dorn discovered the emanation in the uranium series that eventually became the well-known gas {sup 222}Rn. From 1900 through 1908, it was demonstrated that {sup 222}Rn is a radioactive gas found in tap water, highly condensable at low temperatures with a half-life of approximately 3.7 days and can be collected on charcoal by adsorption. Although, radon was discovered in 1900, the effects of prolonged exposure had been suspected and noted 300 years earlier among underground miners who developed lung cancer. During the period from 1924-1932, it was suggested that radon was the cause of high lung cancer incidence. In 1951, researchers at the university of Rochester N.Y. pointed out that the lung cancer health hazard was from the alpha radiation dose delivered by the radon decay products that deposited in the respiratory tract. The findings of the BEIR Committee Report VI, which was based on epidemiological studies in different groups of mines in the 1950's and 1960's and on laboratory studies, showed that from 60,000 miners over 2,600 developed lung cancer where only 750 were expected.Since 1998, the epidemiological study conducted in Iowa US, showed beyond any reasonable doubt that radon decay products cause lung cancer among women who lived at least twenty years in their homes. This paper will cover early radon measurements in soil, building material, ground water and in different air environments such as in the atmosphere, caves spas, underground mines and in residential indoor air environment. Radon measurements were conducted in many areas for diagnostic purposes. Radon was used as natural tracer to study air masses, vertical diffusion, and atmospheric studies, in earthquake prediction, and as a geological indicator for radium and uranium. In the early radon measurements, electroscopes, electrometers and primitive ionization chambers were used for many years. In the 1940's fast pulse ionization chambers replaced total ionization chambers. From the mid 1950's onwards a variety of radon measuring instruments were developed to assess the radon and radon decay product exposure to underground miners, workers at contaminated sites with uranium and radium tailings and to the general public in residential buildings. In the last twenty years, new instruments and methods were developed to measure radon by using grab, integrating and continuous modes of sampling. The most common are scintillation cell monitors, activated carbon collectors, electret ionization chambers, alpha track detectors, pulse and current ionization chambers and solid-state alpha detectors.

54 ENVIRONMENTAL SCIENCES↗