Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Quantitative grating-based x-ray dark-field computed tomography

Grating-based x-ray dark-field computed tomography is a functional method that utilizes the scattering contrast mechanism to explore the inaccessible spatially resolved internal structure of the sample. In this letter, we show that the second moment of the scattering angle distribution can be expressed as the minus logarithm of the visibility degradation of the oscillation curve in grating-based imaging. According to the conclusion of Khelashvili et al. [Phys. Med. Biol. 51, 221 (2006)], the minus logarithm of the visibility ratio fulfills the line integral condition; consequently the scattering information can be reconstructed quantitatively by conventional computed tomography algorithms. Results from a computer simulation and from an actual experiment both validate our deduction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmic Ray Inspection and Passive Tomography for SNM Detection

The Cosmic Ray Inspection and Passive Tomography (CRIPT) project has recently started investigating the detection of illicit Special Nuclear Material in cargo using cosmic ray muon tomography and complementary neutron detectors. We are currently performing simulation studies to help with the design of small scale prototypes. Based on the prototype tests and refined simulations, we will determine whether the muon tracking system for the full scale prototype will be based on drift chambers or extruded scintillator trackers. An analysis of the operations of the Port of Montreal has determined how long muon scan times should take if all or a subset of the cargo is to be screened. As long as the throughput of the muon system(s) is equal to the rate at which containers are unloaded from ships, the impact on port operations would not be great if a muon scanning stage were required for all cargo. We also show preliminary simulation results indicating that excellent separation between Al, Fe and Pb is possible under ideal conditions. The discrimination power is reduced but still significant when realistic momentum resolution measurements are considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image reconstruction from sparse data ion synchrotron-radiation-based micro-tomography.

Synchrotron-radiation-based microcomputed-tomography (SR-{micro}CT) is a powerful tool for yielding 3D structural information of high spatial and contrast resolution about a specimen preserved in its natural state. A large number of projection views are required currently for yielding SR-{micro}CT images by use of existing algorithms without significant artifacts. When a wet biological specimen is imaged, synchrotron x-ray radiation from a large number of projection views can result in significant structural deformation within the specimen. A possible approach to reducing imaging time and specimen deformation is to decrease the number of projection views. In the work, using reconstruction algorithms developed recently for medical computed tomography (CT), we investigate and demonstrate image reconstruction from sparse-view data acquired in SR-{micro}CT. Numerical results of our study suggest that images of practical value can be obtained from data acquired at a number of projection views significantly lower than those used currently in a typical SR-{micro}CT imaging experiment.

99 GENERAL AND MISCELLANEOUS↗

Electron holographic tomography for mapping the three-dimensional distribution of electrostatic potential in III-V semiconductor nanowires

Electron holographic tomography (EHT), the combination of off-axis electron holography with electron tomography, is a technique, which can be applied to the quantitative 3-dimensional (3D) mapping of electrostatic potential at the nanoscale. Here, we show the results obtained in the EHT investigation of GaAs and GaAs-AlGaAs core-shell nanowires grown by Au-catalysed metalorganic vapor phase epitaxy. The unique ability of EHT of disentangling the materials mean inner potential (MIP) from the specimen projected thickness allows reconstruction of the nanowire 3D morphology and inner compositional structure as well as the measurement of the MIP.

43 PARTICLE ACCELERATORS↗

Enhanced x-ray imaging for a thin film cochlear implant with metal artefacts using phase retrieval tomography

Phase retrieval tomography has been successfully used to enhance imaging in systems that exhibit poor absorption contrast. However, when highly absorbing regions are present in a sample, so-called metal artefacts can appear in the tomographic reconstruction. We demonstrate that straightforward approaches for metal artefact reconstruction, developed in absorption contrast tomography, can be applied when using phase retrieval. Using a prototype thin film cochlear implant that has high and low absorption components made from iridium (or platinum) and plastic, respectively, we show that segmentation of the various components is possible and hence measurement of the electrode geometry and relative location to other regions of interest can be achieved.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of neutron tomography and phase contrast imaging technique

This paper presents design and development of a state of art neutron imaging technique at CIRUS reactor with special reference for techniques adopted for tomography and phase contrast imaging applications. Different components of the beamline such as collimator, shielding, sample manipulator, digital imaging system were designed keeping in mind the requirements of data acquisition time and resolution. The collimator was designed in such a way that conventional and phase contrast imaging can be done using same collimator housing. We have done characterization of fuel pins, study of hydride blisters in pressure tubes hydrogen based cells, two phase flow visualization, and online study of locomotive parts etc. using neutron tomography and radiography technique. We have also done some studies using neutron phase contrast imaging technique on this beamline.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Postmortem analysis of sand grain crushing from pile interface using X-ray tomography

Pile foundations of offshore platforms, wind and water turbines are typically subjected to a variety of cyclic loading paths due to their complex environment. While many studies focus on global pile behaviour, the soil-pile interface is explored here by a micromechanical study of the soil layer in contact with the pile surface. This work is devoted to the analysis of frozen post-mortem silica sand samples recovered at the pile interface following installation and cyclic loading tests in a calibration chamber using x-ray tomography. An experimental procedure developed for three dimensional (3D) snow imaging was adapted for the recovery of the in-situ sand samples to preserve their structure during tomography scans. 3D images at a pixel size of 7 {mu}m were then obtained using a cryogenic cell. Results confirm the presence of a shear band at the pile surface as well as void ratios changes in the direction of the pile's radius.

36 MATERIALS SCIENCE↗

Fast synchrotron X-ray tomography study of the rod packing structures

We present a fast synchrotron X-ray tomography study of the packing structures of rods under tapping. Utilizing the high flux of the X-rays generated from the third-generation synchrotron source, we can complete a tomography scan within several seconds, after which the three-dimensional (3D) packing structure can be obtained for the subsequent structural analysis. Due to the high-energy nature of the X-ray beam, special image processing steps including image phase-retrieval has been implemented. Overall, this study suggests the possibility of acquiring statistically significant static packing structures within a reasonable time scale using high-intensity X-ray sources.

36 MATERIALS SCIENCE↗

Feasibility study of endoscopic x-ray luminescence computed tomography: Simulation demonstration and phantom application

Even though endoscopic fluorescence diffuse optical tomography (eFDOT) exhibits significant potential, currently its application is limited due to the existence of strong autofluorescence and the imaging inaccuracy caused by a very short source-detector distance. Motivated by the emerging X-ray luminescence computed tomography (XLCT) technology, we presented an endoscopic XLCT (eXLCT) methodology. In the methodology, the aperture angle of the objective was incorporated into the forward model, providing a more accurate description of light propagation. Numerical simulation with a heterogeneous geometry and an imaging experiment with a physical phantom were illustrated to demonstrate the feasibility of the presented eXLCT methodology.

36 MATERIALS SCIENCE↗

Atom probe tomography evaporation behavior of C-axis GaN nanowires: Crystallographic, stoichiometric, and detection efficiency aspects

The field evaporation behavior of c-axis GaN nanowires was explored in two different laser-pulsed atom probe tomography (APT) instruments. Transmission electron microscopy imaging before and after atom probe tomography analysis was used to assist in reconstructing the data and assess the observed evaporation behavior. It was found that the ionic species exhibited preferential locations for evaporation related to the underlying crystal structure of the GaN and that the species which evaporated from these locations was dependent on the pulsed laser energy. Additionally, the overall stoichiometry measured by APT was significantly correlated with the energy of the laser pulses. At the lowest laser energies, the apparent composition was nitrogen-rich, while higher laser energies resulted in measurements of predominantly gallium compositions. The percent of ions detected (detection efficiency) for these specimens was found to be considerably below that shown for other materials, even for laser energies which produced the expected Ga:N ratio. The apparent stoichiometry variation and low detection efficiency appear to be a result of evaporation of Ga ions between laser pulses at the lowest laser energies and evaporation of neutral N{sub 2} species at higher laser energies. All of these behaviors are tied to the formation of nitrogen-nitrogen bonds on the tip surface, which occurred under all analysis conditions. Similar field evaporation behaviors are therefore expected for other materials where the anionic species readily form a strong diatomic bond.

36 MATERIALS SCIENCE↗

Multispectral guided fluorescence diffuse optical tomography using upconverting nanoparticles

We report on improved image detectability for fluorescence diffuse optical tomography using upconverting nanoparticles doped with rare-earth elements. Core-shell NaYF{sub 4}:Yb{sup 3+}/Er{sup 3+}@NaYF{sub 4} upconverting nanoparticles were synthesized through a stoichiometric method. The Yb{sup 3+}/Er{sup 3+} sensitizer-activator pair yielded two anti-Stokes shifted fluorescence emission bands at 540 nm and 660 nm, here used to a priori estimate the fluorescence source depth with sub-millimeter precision. A spatially varying regularization incorporated the a priori fluorescence source depth estimation into the tomography reconstruction scheme. Tissue phantom experiments showed both an improved resolution and contrast in the reconstructed images as compared to not using any a priori information.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lamb mode selection for accurate wall loss estimation via guided wave tomography

Guided wave tomography offers a method to accurately quantify wall thickness losses in pipes and vessels caused by corrosion. This is achieved using ultrasonic waves transmitted over distances of approximately 1–2m, which are measured by an array of transducers and then used to reconstruct a map of wall thickness throughout the inspected region. To achieve accurate estimations of remnant wall thickness, it is vital that a suitable Lamb mode is chosen. This paper presents a detailed evaluation of the fundamental modes, S{sub 0} and A{sub 0}, which are of primary interest in guided wave tomography thickness estimates since the higher order modes do not exist at all thicknesses, to compare their performance using both numerical and experimental data while considering a range of challenging phenomena. The sensitivity of A{sub 0} to thickness variations was shown to be superior to S{sub 0}, however, the attenuation from A{sub 0} when a liquid loading was present was much higher than S{sub 0}. A{sub 0} was less sensitive to the presence of coatings on the surface of than S{sub 0}.

42 ENGINEERING↗

Thermal stability of curved ray tomography for corrosion monitoring

Guided wave tomography is being developed as an effective tool for continuous monitoring of corrosion and erosion depth in pipelines. A pair of transmit- and receive-ring arrays of ultrasonic transducers encircles the pipe and delimits the section to be monitored. In curved ray tomography (CRT), the depth profile is estimated from the time delay matrix, Δτ, whose ij-th entry is the phase traveltime difference between the current and baseline signals measured between transducers i and j of the transmit and receive-ring arrays, respectively. Under perfectly stable experimental conditions, the non-zero entries of Δτ are only due to the occurrence of damage and provide a reliable input to CRT. However, during field operation, Δτ can develop non-zero entries due to a number of environmental changes ranging from temperature variations to degradation of transducer-pipe coupling and transducer intrinsic performance. Here, we demonstrate that these sources of instability can be eliminated by exploiting the spatial diversity of array measurements in conjunction with EMAT transducer technology which is intrinsically stable owing to its non-contact nature. The study is based on a full-scale experiment performed on a schedule 40, 8’ diameter, 3 m length steel pipe, monitored with two EMAT ring arrays. It is shown that for an irregularly shaped defect the proposed method yields maximum depth estimations that are as accurate as single point ultrasonic thickness gaging measurements and over a wide temperature range up to 175°C. The results indicate that advanced inversion schemes in combination with EMAT transduction offer great potential for continuously monitoring the progression of corrosion or erosion damage in the oil and gas industry.

42 ENGINEERING↗

A microwave tomography system using a tunable mirror for beam steering

Microwave tomography is a fast-growing technique in the fields of NDE and medical industry. This paper presents a new microwave tomography system which reduces the complexities of conventional microwave imaging systems by utilizing a reconfigurable mirror, a tunable reflectarray antenna. In order to build a tunable reflectarray with beam steering capabilities, the unit cell characteristics should dynamically alter. Modelling and experimental results of a single unit cell are presented in this work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of electron-matter interaction during wet-STEM electron tomography

Tomography is an efficient tool to probe the 3 dimensional (3D) structure of materials. In the laboratory, a device has been developed to perform electron tomography in an environmental scanning electron microscopy (ESEM). The configuration of Scanning Transmission Electron Microscopy (STEM) in Environmental Scanning Electron Microscopy (ESEM) provides a novel approach for the characterization of the 3D structure of materials and optimizes a compromise between the resolution level of a few nm and the large tomogram due to the high thickness of transparency. Moreover, STEM allows the observation in 2D of wet samples in an ESEM by finely controlling the sample temperature and the water pressure of the sample environment. It has been recently demonstrated that it was possible to acquire image series of hydrated objects and thus to attain 3D characterization of wet samples. In order to get reliable and quantitative data, the present study deals with the simulation of electron-matter interactions. From such simulation on the MCM-41 material, we determine the minimum quantity of water layer which can be detected on wet materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of continuous-wave domain fluorescence diffuse optical tomography for quality control on agricultural produce

The importance of monitoring the quality of vegetables and fruits is prosperity by giving a competitive advantage for producer and providing a more healthy food for consumer. Diffuse Optical Tomography (DOT) is offering the possibility to detect the internal defects of the agricultural produce quality. Fluorescence diffuse optical tomography (FDOT) is the development of DOT, offering the possibilities to improve spatial resolution and to contrast image. The purpose of this research is to compare FDOT and DOT in forward analysis with continuous wave approach. The scattering and absorbing parameters of potatoes are used to represent the real condition. The object was illuminated by the NIR source from some positions on the boundary of object. A set of NIR detector are placed on the peripheral position of the object to measure the intensity of propagated or emitted light. In the simulation, we varied a condition of object then we analyzed the sensitivity of forward problem. The result of this study shows that FDOT has a better sensitivity than DOT and a better potential to monitor internal defects of agricultural produce because of the contrast value between optical and fluorescence properties of agricultural produce normal tissue and defects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact cold stage for micro-computerized tomography imaging of chilled or frozen samples

High resolution X-ray microCT (computerized tomography) can be used to image a variety of objects, including temperature-sensitive materials. In cases where the sample must be chilled or frozen to maintain sample integrity, either the microCT machine itself must be placed in a refrigerated chamber, or a relatively expensive commercial cold stage must be purchased. We describe here the design and construction of a low-cost custom cold stage suitable for use in a microCT imaging system. Our device uses a boron nitride sample holder, two-stage Peltier cooler, fan-cooled heat sink, and electronic controller to maintain sample temperatures as low as −25 °C ± 0.2 °C for the duration of a tomography acquisition. The design does not require modification to the microCT machine, and is easily installed and removed. Our custom cold stage represents a cost-effective solution for refrigerating CT samples for imaging, and is especially useful for shared equipment or machines unsuitable for cold room use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplexed absorption tomography with calibration-free wavelength modulation spectroscopy

We propose a multiplexed absorption tomography technique, which uses calibration-free wavelength modulation spectroscopy with tunable semiconductor lasers for the simultaneous imaging of temperature and species concentration in harsh combustion environments. Compared with the commonly used direct absorption spectroscopy (DAS) counterpart, the present variant enjoys better signal-to-noise ratios and requires no baseline fitting, a particularly desirable feature for high-pressure applications, where adjacent absorption features overlap and interfere severely. We present proof-of-concept numerical demonstrations of the technique using realistic phantom models of harsh combustion environments and prove that the proposed techniques outperform currently available tomography techniques based on DAS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗