A lightweight bimetallic actuator for spacecraft thermal control

The design, development, and construction of two types of active thermal-control systems are described. These designs are based on the controlled angular deflections of spiral-wound bimetallic actuators. The use of these actuators and lightweight louvers results in a frictionless system that is low in weight yet simple in design and low in cost. Both designs exhibit high reliability, good performance repeatability, and do not require power from the spacecraft. Design philosophy and implementation, design tradeoffs, and materials selection are reviewed. The test program is described, and results are presented.

Schilling, K. L.↗

Thermal modeling of phase change solidification in thermal control devices including natural convection effects

Natural convection effects in phase change thermal control devices were studied. A mathematical model was developed to evaluate natural convection effects in a phase change test cell undergoing solidification. Although natural convection effects are minimized in flight spacecraft, all phase change devices are ground tested. The mathematical approach to the problem was to first develop a transient two-dimensional conduction heat transfer model for the solidification of a normal paraffin of finite geometry. Next, a transient two-dimensional model was developed for the solidification of the same paraffin by a combined conduction-natural-convection heat transfer model. Throughout the study, n-hexadecane (n-C16H34) was used as the phase-change material in both the theoretical and the experimental work. The models were based on the transient two-dimensional finite difference solutions of the energy, continuity, and momentum equations.

Ukanwa, A. O.↗

Study of fuel cell thermal control systems for advanced missions.

This study evaluated many heat rejection and thermal control concepts which could be applied to fuel cells for long term (600 hours) orbital and lunar surface missions. The concepts considered several types of radiators which utilized pumped gas, liquid and two phase working fluids and incorporated solid conduction fins as well as heat pipe (vapor chamber) fins. The comparison of the concepts was based on weight, area and other factors such as standby power, ability to accommodate heat load variation, control complexity, and meteoroid survival capability. A design selection matrix was established and an optimum (primary) and an alternate (secondary) heat rejection concept was chosen. Heat rejection techniques utilizing self-controlled heat pipe radiators dominate the results.

Caputo, R. S.↗

Development of an emulation-simulation thermal control model for space station application

Many features were added to the Thermal Control System (TCS) program to increase its user-friendliness. Several apparent inconsistencies were identified. In some instances, these have led to modifications to the source programs. With the summary line-sizing information, the user can more readily compare the TCS program results with other available data. Two mathematical models were completed: one deals with sizing and analysis of bus heat exchangers and the other provides a means of analyzing a variety of heat pipe radiator designs. A generic heat pipe model was added to the TCS Analysis Program.

Colwell, Gene T.↗

Thermal control paints on LDEF: Results of sub-experiment 802-18

Several thermal control paints were flown on the LDEF, including the white paints Chemglaze A276, S13GLo, and YB-71, and the black paint D-111. The effects of low earth orbit, which includes UV radiation and atomic oxygen, varied significantly with each paint and its location on LDEF. This paper will examine the performance of these paints as determined by changes in their optical and physical properties, including solar absorptance, surface chemical changes, and changes in surface morphology. It will also provide a correlation of these optical and physical property changes to the physical phenomena that occurred in these materials during the LDEF mission.

Jaggers, Christopher H.↗

Thermal control paints on LDEF: Results of M0003 sub-experiment 18

Several thermal control paints were flown on the Long Duration Exposure Facility (LDEF), including the white paints Chemglaze A276, S13GLO, and YB-71, and the black paint D-111. The effects of low earth orbit, which includes those induced by UV radiation and atomic oxygen, varied significantly with each paint and its location on LDEF. For example, samples of Chemglaze A276 located on the trailing edge of LDEF darkened significantly due to UV-induced degradation of the paint's binder, while leading edge samples remained white but exhibited severe atomic oxygen erosion of the binder. Although the response of S13GLO to low earth orbit is much more complicated, it also exhibited greater darkening on trailing edge samples as compared to leading edge samples. In contrast, YB-71 and D-111 remained relatively stable and showed minimal degradation. The performance of these paints as determined by changes in their optical and physical properties, including solar absorptance as well as surface chemical changes and changes in surface morphology is examined. It will also provide a correlation of these optical and physical property changes to the physical phenomena that occurred in these materials during the LDEF mission.

Jaggers, C. H.↗

International Space Station Internal Thermal Control System Cold Plate/Fluid-Stability Test: Two Year Update

Operation of the Internal Thermal Control System (ITCS) Cold Plate/Fluid-Stability Test Facility commenced on September 5, 2000. The facility was intended to provide advance indication of potential problems on board the International Space Station (ISS) and was designed: - To be materially similar to the flight ITCS. - To allow for monitoring during operation. - To run continuously for three years. During the first two years of operation the conditions of the coolant and components were remarkably stable. During this same period of time, the conditions of the ISS ITCS significantly diverged from the desired state. Due to this divergence, the test facility has not been providing information useful for predicting the flight ITCS condition. Results of the first two years are compared with flight conditions over the same time period, showing the similarities and divergences. To address the divergences, the test facility was modified slightly to more closely match the flight conditions, and to gain insight into the reasons for the divergence. Results of the modifications are discussed and provide insight into the development of the conditions on orbit.

Paul Wieland↗

Selection of an Alternate Biocide for the ISS Internal Thermal Control System Coolant, Phase 2

The ISS (International Space Station) ITCS (Internal Thermal Control System) includes two internal coolant loops that utilize an aqueous based coolant for heat transfer. A silver salt biocide had previously been utilized as an additive in the coolant formulation to control the growth and proliferation of microorganisms within the coolant loops. Ground-based and in-flight testing demonstrated that the silver salt was rapidly depleted, and did not act as an effective long-term biocide. Efforts to select an optimal alternate biocide for the ITCS coolant application have been underway and are now in the final stages. An extensive evaluation of biocides was conducted to down-select to several candidates for test trials and was reported on previously. Criteria for that down-select included: the need for safe, non-intrusive implementation and operation in a functioning system; the ability to control existing planktonic and biofilm residing microorganisms; a negligible impact on system-wetted materials of construction; and a negligible reactivity with existing coolant additives. Candidate testing to provide data for the selection of an optimal alternate biocide is now in the final stages. That testing has included rapid biocide effectiveness screening using Biolog MT2 plates to determine minimum inhibitory concentration (amount that will inhibit visible growth of microorganisms), time kill studies to determine the exposure time required to completely eliminate organism growth, materials compatibility exposure evaluations, coolant compatibility studies, and bench-top simulated coolant testing. This paper reports the current status of the effort to select an alternate biocide for the ISS ITCS coolant. The results of various test results to select the optimal candidate are presented.

Wilson, Mark E.↗

International Space Station (ISS) Internal Active Thermal Control System (IATCS) New Biocide Selection, Qualification and Implementation

The Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) is primarily responsible for the removal of heat loads from payload and system racks. The IATCS is a water based system which works in conjunction with the EATCS (External ATCS), an ammonia based system, which are interfaced through a heat exchanger to facilitate heat transfer. On-orbit issues associated with the aqueous coolant chemistry began to occur with unexpected increases in CO2 levels in the cabin. This caused an increase in total inorganic carbon (TIC), a reduction in coolant pH, increased corrosion, and precipitation of nickel phosphate. These chemical changes were also accompanied by the growth of heterotrophic bacteria that increased risk to the system and could potentially impact crew health and safety. Studies were conducted to select a biocide to control microbial growth in the system based on requirements for disinfection at low chemical concentration (effectiveness), solubility and stability, material compatibility, low toxicity to humans, compatibility with vehicle environmental control and life support systems (ECLSS), ease of application, rapid on-orbit measurement, and removal capability. Based on these requirements, ortho-phthalaldehyde (OPA), an aromatic dialdehyde compound, was selected for qualification testing. This paper presents the OPA qualification test results, development of hardware and methodology to safely apply OPA to the system, development of a means to remove OPA, development of a rapid colorimetric test for measurement of OPA, and the OPA on-orbit performance for controlling the growth of microorganisms in the ISS IATCS since November 3, 2007.

Wilson, Mark E.↗

International Space Station (ISS) Internal Active Thermal Control System (IATCS) New Biocide Selection, Qualification and Implementation

The Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) is primarily responsible for the removal of heat loads from payload and system racks. The IATCS is a water based system which works in conjunction with the EATCS (External ATCS), an ammonia based system, which are interfaced through a heat exchanger to facilitate heat transfer. On-orbit issues associated with the aqueous coolant chemistry began to occur with unexpected increases in CO2 levels in the cabin. This caused an increase in total inorganic carbon (TIC), a reduction in coolant pH, increased corrosion, and precipitation of nickel phosphate. These chemical changes were also accompanied by the growth of heterotrophic bacteria that increased risk to the system and could potentially impact crew health and safety. Studies were conducted to select a biocide to control microbial growth in the system based on requirements for disinfection at low chemical concentration (effectiveness), solubility and stability, material compatibility, low toxicity to humans, compatibility with vehicle environmental control and life support systems (ECLSS), ease of application, rapid on-orbit measurement, and removal capability. Based on these requirements, ortho-phthalaldehyde (OPA), an aromatic dialdehyde compound, was selected for qualification testing. This paper presents the OPA qualification test results, development of hardware and methodology to safely apply OPA to the system, development of a means to remove OPA, development of a rapid colorimetric test for measurement of OPA, and the OPA on-orbit performance for controlling the growth of microorganisms in the ISS IATCS since November 3, 2007.

Wilson, Mark E.↗

Design and Testing of the CubeSat Form Factor Thermal Control Louvers

As CubeSat and SmallSat missions increase in complexity and power consumption they present innate thermal challenges. Science instruments may require thermal stability while a variety of factors such as high-powered components, sunlight and shadow on orbit, or tight spacecraft layout may produce a wide range of temperatures. The CubeSat Form Factor Thermal Control Louvers are a passive method of stabilizing the thermal environment inside of small spacecraft via miniature thermal louvers. These louvers are a patented design, with a technology demonstration version of the louvers operating correctly in flight on the Dellingr CubeSat in 2018. This paper will describe the methods used to develop and test this technology, as well as the results obtained and how this technology may be used in CubeSat and SmallSat missions.

louvers↗

Whisker/Cone growth on the thermal control surfaces experiment no. S0069

An unusual surface 'growth' was found during scanning electron microscope (SEM) investigations of the Thermal Control Surface Experiment (TCSE) S0069 front thermal cover. This 'growth' is similar to the cone type whisker growth phenomena as studied by G. K. Wehner beginning in the 1960's. Extensive analysis has identified the most probable composition of the whiskers to be a silicate type glass. Sources of the growth material are outgassing products from the experiment and orbital atomic oxygen, which occurs naturally at the orbital altitudes of the LDEF mission in the form of neutral atomic oxygen. The highly ordered symmetry and directionality of the whiskers are attributed to the long term (5.8 year) stable flight orientation of the LDEF.

Zwiener, James M.↗

A Multi-Environment Thermal Control System With Freeze-Tolerant Radiator

Future space exploration missions require advanced thermal control systems (TCS) to dissipate heat from spacecraft, rovers, or habitats operating in environments that can vary from extremely hot to extremely cold. A lightweight, reliable TCS is being developed to effectively control cabin and equipment temperatures under widely varying heat loads and ambient temperatures. The system uses freeze-tolerant radiators, which eliminate the need for a secondary circulation loop or heat pipe systems. Each radiator has a self-regulating variable thermal conductance to its ambient environment. The TCS uses a nontoxic, water-based working fluid that is compatible with existing lightweight aluminum heat exchangers. The TCS is lightweight, compact, and requires very little pumping power. The critical characteristics of the core enabling technologies were demonstrated. Functional testing with condenser tubes demonstrated the key operating characteristics required for a reliable, freeze-tolerant TCS, namely (1) self-regulating thermal conductance with short transient responses to varying thermal loads, (2) repeatable performance through freeze-thaw cycles, and (3) fast start-up from a fully frozen state. Preliminary coolant tests demonstrated that the corrosion inhibitor in the water-based coolant can reduce the corrosion rate on aluminum by an order of magnitude. Performance comparison with state-of-the-art designs shows significant mass and power saving benefits of this technology.

Chen, Weibo↗

Pathways towards managing cost and degradation risk of fast charging cells with electrical and thermal controls

The charging rate of Li-ion batteries is limited by the risks of lithium plating and thermal damage, both of which negatively affect lifetime of the batteries. This work analyzes how to minimize charge time and manage the risk of degradation using both electrical and thermal controls. To accomplish this, an electrochemical-thermal model is developed to introduce a constant-risk fast charging protocol which maximizes the charging current while maintaining the cell within pre-defined design limits selected to minimize the risk of degradation. Results indicate 80%-charging of a typical NMC/graphite cell can be achieved within 10 minutes with a cell cost under $100 kW –1 h –1 (corresponding to an 80 μm thick anode) when charged at moderate allowable risks of degradation. Here, we also demonstrate how stretching the allowable risk (i.e., higher temperatures, larger C-rates, and lower anode potential limits) allows affordable design of fast charging cells.

25 ENERGY STORAGE↗