At least 487 records · Page 27

Density of Next-Generation Caustic-Side Solvent Extraction Solvent

This report recommends the appropriate modifier concentration to employ in the Next Generation Solvent (NGS) to be used in the Salt Waste Processing Facility (SWPF) at the Savannah River Site for removal of cesium from legacy tank waste. The Next Generation Caustic-Side Solvent Extraction (NG-CSSX) process employing the NGS is a marked improvement over the original Caustic-Side Solvent Extraction (CSSX) process, as it provides more effective removal of cesium from highly alkaline radioactive wastes and concentrates this removed cesium into an aqueous solution that is easy to vitrify for final disposal. Considerable effort has been devoted to optimizing the chemistry and process conditions of both systems, and their effectiveness has been demonstrated at the pilot scale at the Modular CSSX Unit (MCU). Due to the success of the demonstration and pilot-scale tests, the Salt Waste Processing Facility (SWPF) has been built to process larger volumes of waste with the CSSX process. To accelerate the waste-processing rate of the SWPF beyond its design throughput, plans call for the replacement of the CSSX process by the NG-CSSX process. To implement the NG-CSSX process in equipment optimized for CSSX, adjusting the density of the NGS to match the CSSX solvent density of 0.851 ± 0.0008 g/mL is considered advisable to obtain comparable hydraulic performance. Toward this objective, the density of the NGS has been measured at different temperatures and modifier concentrations to determine that a concentration of 0.650 M Cs-7SB modifier provides the best match for the desired density.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Formulation and Testing with RPP-WTP HLW Simulants (Final Report)

This report presents the results from HLW glass formulation work that was conducted at the Vitreous State Laboratory of The Catholic University of America during Part B1 of the RPP-WTP Project (formally known as TWRS-P) in support of the Privatization contractor, BNFL, Inc. Glass formulation development is required to provide data that are essential for design of the vitrification facility in the near term and for safe and reliable operation of that facility in the longer-term. These data also form the bases from which contractually and technically acceptable immobilized high-level waste (IHLW) products will be devised. Glass formulation therefore impacts many aspects of the vitrification facility design, overall process economics, and contractual compliance. As an integral part of the overall system design, development of glass formulations requires input from many sources including tank waste characterization, pretreatment process definition, flow sheet development, and processing schedules. Accordingly, the glass formulation effort must be responsive to new information as the facility design basis evolves.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DARHT Axis 1 Time-Resolved Injector Energy Measurement

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injected electron beam energy. The DARHT Axis 1 injector of produces a 3-4 MeV, 1-2 kA, 80-ns-FWHM electron beam. Injector capacitive monitors (EVACSUM) are summed to give the injector beam energy. Calibration of EVACSUM was last done in 1999 and is needed. In addition, the flatness of the injector drive voltage is controlled by a peaking capacitor in a Blumlien that is charged by the prime power tank. Time resolved measurements are used to optimize the value of this capacitor.

47 OTHER INSTRUMENTATION↗

Evaluation of Material Balance Approaches for Hanford Direct-Feed Low Activity Waste Processing - 20022

The Hanford Site has accumulated millions of gallons of tank waste from reprocessing spent fuel to recover plutonium, uranium, cesium, and strontium. The supernatant from the accumulated tank waste will be treated using a Direct Feed Low-Activity Waste approach. The supernatant will be treated to remove solids and cesium in the Tank-Side Cesium Removal process in the Hanford tank farm, then vitrified in a semi-batch process in the Hanford Waste Treatment and Immobilization Plant (WTP). Currently, each batch of feed is sampled at three locations prior to being fed to the melter: the feed qualification tank in the Hanford tank farm as well as the concentrate receipt vessel (CRV) and melter feed preparation vessel (MFPV) in the WTP. The feed qualification sample is taken from a large batch of accumulated feed, only two to three samples are expected each year. Approximately 275 samples from the CRVs and 1100 samples from the MFPV are expected each year. An evaluation was performed to determine if a material balance based on the feed qualification sample could replace most of the sampling in the CRVs and MFPVs. The evaluation consisted of three elements: (1) determination of the practicality of using a material balance to estimate the stream composition of the CRV and MFPV contents, (2) evaluation of whether the material balance could be automated using the existing process control system, and (3) determination of the uncertainty in glass composition using the material balance approach. It is assumed that periodic sampling at the CRV and MFPV would be performed periodically to re-baseline the material balance, evaluations are in progress to determine the frequency of this periodic sampling. Process sample locations downstream of the melter were reviewed as well, but the partitioning of semi-volatile species in the melter was determined to preclude extending the material balance approach past the melter. It was determined that replacement of the CRV sample location was feasible and did not increase process uncertainty or significantly impact waste loading. Replacement of the MFPV sample was also determined to be feasible, but that measurement of the glass former chemical addition may be needed prior to addition of these chemicals to the MFPV. This measurement could be performed by an in situ laser-induced breakdown spectroscopy (LIBS) system. Limited tests were performed to evaluate LIBS for direct measurements of the low-activity waste melter feed. The use of a material balance would eliminate over 1200 samples each year if only 10% of the CRV and MFPV batches are sampled and could likely allow the WTP laboratory to operate on days only versus 24/7 operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proton nuclear magnetic resonance (1H NMR) of flammable organic chemicals in radioactive high–level supernatant waste at the Savannah River Site (SRS)

The Savannah River Site stores approximately 36 million gallons of radioactive and hazardous waste that contains approximately 245 million curies. The waste is sent through various chemical processes to reduce its volume and to separate various components. The facility plans to replace formic acid (a chemical used to reduce soluble mercury) with glycolic acid. Recycle solution with glycolate may flow back to the tank farm, where the glycolate can generate hydrogen gas by thermal and radiolytic mechanisms. The current analytical method for detecting glycolate (ion chromatography) in supernatant requires a large dilution to reduce interference from the nitrate anions. Hydrogen nuclear magnetic resonance is an analytical method that requires less sample dilution. It takes advantage of the CH 2 group in glycolate. Liquid samples were spiked with four different levels of glycolate to build a calibration line, as it is recommended in the standard addition method. The detection and quantitation limits determined were 1 and 5 ppm, respectively, for 32 scans, which is well below the process limit of 10 ppm. In one test, 800 scans of a supernatant spiked with 1 ppm glycolate resulted in a -CH 2 peak with a signal-to-noise ratio of 36.

1H↗

Expansion of the Direct Feed High-Level Waste Glass Composition in the High Al Range

Baseline glass compositions have been developed and demonstrated for successful immobilization of Hanford high-level waste (HLW) prepared through a pretreatment process. Recent enhanced waste glass formulations have shown promise to increase the waste loading of pretreated sludge compositions from a broader range of HLW feeds. This project proposes to increase the loading of minimally pretreated Hanford HLW in glass by expanding the existing database and glass property-composition models. Estimated direct-feed high level waste (DFHLW) compositions were generated by the Hanford Tank Operations Contractor and used by Pacific Northwest National Laboratory to determine target glass compositions. Gaps in existing data were identified including one high-priority gap in the high Al compositional region. This report summarizes the data collected during the characterization of the DFHLW High Al Glass Matrix. These glasses were intentionally designed with high aluminum concentrations (15 to 30 wt%) and a high likelihood of nepheline formation, which is known to negatively affect glass durability. Some glasses were expected to either fail or approach property constraints to fill data gaps in poorly understood regions of the compositional space due to lack of data. Out of the 50 glasses tested, 14 glasses formed nepheline, while the model predicted nepheline formation in 20 glasses. All quenched glasses met the product consistency test durability constraint; however, 8 glasses failed this constraint after undergoing the canister centerline cooling treatment. Additionally, 17 glasses did not meet the viscosity constraints, 4 failed the EC constraints, and 2 exceeded the allowable T2% for spinel crystal formation. All glasses satisfied the SO 3 solubility limit. The resulting dataset provides valuable information to improve model accuracy and reduce prediction uncertainty. These insights will ultimately support the development of more robust glass formulation strategies, enabling higher waste loadings, reducing operational risks, and expanding the processing envelope.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structure property correlations in wet-spun textile PAN fibers for cost-effective carbon fibers applicable in H 2 storage tank manufacturing

The economic viability of high-strength carbon fibers is pivotal for their integration into Type IV compressed hydrogen storage tanks. Oak Ridge National Laboratory is advancing this objective by developing cost-effective, textile-grade polyacrylonitrile (PAN) precursor fibers through an optimized wet spinning-process to garner more microstructural control over the precursor fibers. Here, this study examines the microstructural characteristics of PAN fibers, particularly the crystalline orientation factor, and their impact on mechanical properties in both precursor and thermally converted carbon fibers (CFs). Three wet-spun PAN fibers, all having diameters of 12-13 µm but varying orientation factors were assessed. Comprehensive characterization using X-ray scattering and microscopy revealed that fibers with higher orientation factors exhibited enhanced crystallinity and optimized crystallite sizes. Mechanical testing demonstrated that the PAN fiber with the highest orientation factor achieved the greatest tensile strength (98 ksi) and modulus (1.60 Msi). Additionally optical and scanning electron microscopy confirmed smooth and defect-free surfaces across all samples. These findings indicate that manipulating spinning parameters to maximize orientation factor is more impactful in achieving high strength and modulus over factors attributed to crystallinity and crystallite sizes. Here, highest performing CFs, thermally processed in lab from textile-grade precursor averaged 558 ksi, a 10% increase over previous results.

36 MATERIALS SCIENCE↗

Long-Term PCT of ILAW Glasses (Final Report FY2020)

About 50 million gallons of high-level mixed waste is currently stored in underground tanks at The United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in a near-surface engineered facility – the Integrated Disposal Facility (IDF) – on the Hanford site, while the IHLW product is designed for deep geological disposal in a national facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. The objective of the work described in this report is to perform testing, data collection, and analyses for the ILAW glass product for subsequent use in the performance assessment (PA) of the IDF to assess potential environmental risks associated with long-term storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY2021 Long-Term PCT of ILAW Glasses

Approximately 54 to 56 million gallons of radioactive waste is currently stored in underground tanks at The United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in a near-surface engineered facility – the Integrated Disposal Facility (IDF) – on the Hanford site, while the IHLW product is designed for deep geological disposal in a national facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. The objective of the work described in this report is to perform testing, data collection, and analyses for the ILAW glass product for subsequent use in the performance assessment (PA) of the IDF to assess potential environmental risks associated with long-term storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Literature Review Investigating Historical Plutonium Solubility in SRS Tank Waste

The Savannah River Site (SRS) has designed the Accelerated Basin De-inventory (ABD) program to accelerate the de-inventory of L-Basin and accelerate the Spent Nuclear Fuel (SNF) disposition mission. Similarly, the H-Canyon facility at SRS is reestablishing the 6.3D electrolytic dissolver for dissolving unirradiated stainless-steel (SS) clad Fast Critical Assembly (FCA) fuel. In both discard types (ABD and FCA), plutonium is present and its complex solubility when composited to Concentration, Storage, and Transfer Facility (CSTF) sludge is being investigated as it may have downstream impacts to the liquid waste (LW) organization. This literature review aims to highlight and compile the existing literature on plutonium solubility in waste streams relevant to ABD and FCA discards, as well as discuss some considerations in analyzing solubility data of plutonium. This review serves to help define the analysis methods for future experiments involving plutonium (and other actinides) and in designing appropriate testing conditions surrounding these studies. This review is broken up into five parts and will discuss: (i) The possible effects of testing hold time and temperature on plutonium solubility, (ii) the influence of neutralization rate and particle size of freshly precipitated discards, (iii) the coprecipitation of plutonium with iron and uranium, (iv) predictive solubility modeling and the influence of supernate anions on solubility, and (v) the speciation of plutonium in solutionas a result of supernate anions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange of Selected Group II Metals and Lead by Crystalline Silicotitanate and Competition for Cs Exchange Sites

A series of batch contact tests were conducted to evaluate the exchange behavior of Ba, Ca, Pb, and Sr onto crystalline silicotitanate (CST) in support of an expedited Cs removal and pretreatment system at the Hanford site. Binary Na/M 2+ and ternary Na/Cs/M 2+ isotherms were generated to understand selectivity, capacity, and competitive impact of each analyte on Cs uptake from a simple 1 M NaOH/4.6 M NaNO 3 simulant. Analyte loading from a 0.1 M NaOH/5.5 M NaNO 3 simulant was assessed to determine the effect of hydroxide concentration on binary Na/M 2+ isotherms. Finally, results from binary and ternary isotherms indicated that group II metals, and Pb do not impact CST performance toward CST at concentrations expected in Hanford tank waste supernate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation (Rev.1)

The Hanford Tank Waste Treatment and Immobilization Plant Low Activity Waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of discovering that sampling locations do not meet the qualification criteria on the full-scale stacks. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. For this analysis, the range of qualified flow rates listed is conservatively based on the average DV through 6 DV for LV-S1, LV-S2, and LV-C2, and 1/3 DV to 3 DV for LV-S3. Table S1 lists the operating flow rates along with the conservative lower and upper qualified stack flow rates for each of the LAW facility stacks. For each stack, the operating flow is below the upper qualified stack.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enabling in-situ LIBS measurements of liquids and slurries

The aim of this work was to explore the use of, and further develop, a in-situ and near-real time LIBS (Laser Induced Breakdown Spectroscopy) instrument to measure liquids relevant to the Hanford site. Specifically, we investigated the feasibility of using LIBS to measure the cation composition of HLW (High Level Waste) streams. In addition, we focused on enabling continuous interrogation of those liquids using the LIBS system. For the first part, we investigated simple (sodium nitrate) solutions as well as various Hanford tank waste surrogate slurries. We showed that relevant cations (such as sodium, aluminum, magnesium, potassium) can be measured via LIBS under good conditions but the results – both quantitative and qualitative (aka reproducibility) – strongly depend on the kind and concentration of the material used. The dependence of signal intensity on concentration was also confirmed by other measurements conducted (sodium chloride and sodium nitrate in water). For the second part, we investigated the influence of varying depth and concentration of a liquid sample. We observed that for the concentrations and fill depths investigated, the liquid fill depth did not impact the emission intensity of the analyte, while concentration is confirmed to have significant effects. The results of the sample depth experiments influenced testing of waste surrogates. In addition, we focused on further developing and adapting data fitting tools in order to efficiently, accurately, and reproducibly identify the elements and materials present in a LIBS spectrum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment Maintenance Plan for the Active Low-Level Burial Ground Trenches 31, 34, and 94 at the Hanford Site

This report documents the maintenance plan for the Hanford Site 200 West Area Active Low-Level Burial Ground Trenches 31 and 34 and 200 East Area Active Trench 94 performance assessment (PA). The PA maintenance plan is one of several supporting documents that are compendiums to the active trenches (Trenches 31, 34, and 94) PA as required in DOE O 435.1, Radioactive Waste Management . The PA is documented in DOE/RL-2021-26, Performance Assessment of Active Trenches in 200 East and West Low-Level Burial Grounds at the Hanford Site . This plan follows the requirements and outline specified in the applicable U.S. Department of Energy (DOE) standard used for developing documents supporting DOE-STD-5002-2017, Disposal Authorization Statement and Tank Closure Documentation . This maintenance plan summarizes the following major activities DOE plans to conduct to maintain the Trenches 31, 34, and 94 PA: Monitoring; Research and development; Planned reviews and analyses; Revisions of Trenches 31, 34, and 94 PA. The planned research and development activities relate to evaluating the key assumptions, including evaluating conceptual model assumptions and parameter value assumptions used in the PA. The planned research and development activities include those that are designed to track the release mechanisms for Category 1, Category 3, and uranium billet waste sources, as well as continued characterization and related modeling of the natural environment in the Central Plateau of the Hanford Site. In addition, the planned research and development activities include focused testing and evaluation of engineered and natural materials to reduce the uncertainty in the conceptual models and parameter values used in the PA. All key and secondary issues identified during the review of the PA by the Low-Level Waste Disposal Facility Federal Review Group have been resolved prior to finalization of the PA. There are no outstanding issues.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Product consistency test results for the LAW Phase 4 gases

In this report, the Savannah River National Laboratory provides chemical analysis of Product Consistency Test (PCT) leachates from a series of simulated nuclear waste glasses fabricated at the Pacific Northwest National Laboratory (PNNL). The series included quenched and canister-centerline cooled (CCC) versions of the glasses. The resulting data will be used in the development of enhanced property/composition models for waste vitrification at Hanford. For some of the glass leachates, minor scatter among the triplicate values of some analytes were observed. For other leachates, there were more significant differences among the triplicate values. A review of the PCT data noted that there was little difference between the normalized values based on targeted or measured glass composition. Several of the study glasses have normalized concentration of element “i” (NCi) values that are greater than the Hanford Tank Waste Treatment and Immobilization Plant immobilized low-activity waste constraint of 4 g/L for boron (B), sodium (Na), and silicon (Si). The results of these glasses will help ensure the ability of advanced glass performance models to appropriately predict acceptable compositions. For the study glasses with NCi values exceeding 4 g/L, the CCC heat treatment samples had generally lower NCi values than quenched samples. The samples of the Environmental Assessment (EA) reference glass included with each PCT set had generally consistent NCi values. The release rates for boron (B), potassium (K), lithium (Li), sodium (Na), and silicon (Si) were highly correlated for the study glasses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterizing The Mechanical Properties of Polyurethane Foams

The Department of Energy has many radioactive facilities that are on the path of deactivation and decommissioning (D and D). These facilities can sit cold and dark for many years before final disposition, and must be maintained to ensure no radiological release occurs in the interim. Improvements and additions to D and D tool sets can greatly: Save time and money, Reduce worker risk. Conventional fixatives widely used often take the form of paints or films that are not readily applicable to 3-dimensional void spaces. Foams are one promising platform that may offer solutions to a number of contaminated problem sets such as: Gloveboxes, Pipes, Tanks. SRNL is working to characterize various commercial foams that would encapsulate the interior volume of a given space and are capable of immobilizing any remaining contamination. One key performance metric of these foams is how well they will perform in an accident scenario. To this end, SRNL is researching the mechanical properties of these foams to ensure that the material can withstand the environment of application while maintaining structural integrity. ASTM standard E3191-18 served as a guiding document for this project, outlining the requirements that foaming fixatives used for the mitigation of radioactive contamination need to meet before being implemented. Objective: Quantification of the mechanical properties of 6 commercial polyurethane foams was performed using multiple ASTM standards to record measurements for: Compression testing: Flexible Foams, Force required to produce 50% compression, Rigid Foams, Compressive and apparent modulus, Point of 10% core deformation, The 'Zero Deformation' point, Compressive strength, Yield point. Tensile testing: Tensile strength, Tensile stress, Percent elongation. Experiment 1: An electromechanical compressive tester (MTS Criterion Series 43) was used to evaluate 6 foams (4 flexible, 2 rigid). Per ASTM D1621, each rigid foam was compressed at 10% of the measured thickness per minute until the sample was 13% of it's original thickness. Per ASTM D35/4, each flexible foam was pre-flexed twice to 80% original thickness at a rate of 250 mm/min, then compressed to 80% original thickness at a rate of 50 mm/min. Experiment 2: An electromechanical tensile tester (MTS Criterion Series 43) was used to evaluate 6 foams (4 flexible, 2 rigid). Per ASTM D1623, rigid foams were pulled apart at a rate of 1.27 mm/min until the sample broke. Per ASTM D35/4, flexible foams were pulled apart at a rate of 500 mm/min until the sample broke. The strongest material in both compression and tensile testing scenarios was found to be the rigid intumescent polyurethane Hilti foam. The experiments revealed that the Hilti foam in a tensile scenario had a peak stress value that was larger than the closest competitor by a factor of 2.3 and a compressive yield point that was larger than the closest competitor by a factor of 1.4, indicating that the Hilti foam is the best choice for implementation in mechanically harsh environments. The performance metrics measured can serve as a basis for future mechanical tests that would help set relevant ASTM standards (E3191) for intumescent polyurethane foams in fixating applications. Tests like surface adhesion, impact, and flame tests would serve as a better indicator as to how this material would perform in environmentally harsh scenarios often found in decommissioned nuclear facilities. Further tests of the foams' intumescent properties would also be important should these foams be implemented in environmentally harsh scenarios.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crucible Melter Simulation in Nek5000

Nuclear tank waste at the Hanford site is slated for vitrification in large scale refractory-lined melters to transform it into a stable borosilicate waste form suitable for long-term storage or disposal. Molten glass corrodes the refractory lining over time at a rate correlated to the velocity of molten glass against the refractory-lined wall. To properly design a melter and plan for maintenance, it is necessary to accurately model the glass flow and find the correlation between flow velocity and corrosion rate. This modeling was started in STAR-CCM+ CFD software and is being continued in Nek5000 for its fast-running and quick turnaround code. This poster explains the basic process of reconstructing the geometry, fluid properties, and heating of test melters in Nek5000. The geometry is imported from a mesh file and boundary conditions assigned based on surface IDs. The fluid properties are set in the .par and .usr case files. The heating of the actual crucibles in joule heating with electrodes but simulated in Nek5000 with a volumetric heat source term. This volumetric heat source is fit to the actual heating profile with piecewise polynomials and exponentials. Basic results and verification methods are explained in the poster, as well as further work that must be done to complete modeling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗