Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIMING PROPERTIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Production of highly ionized species in high-current pulsed cathodic arcs

Time resolved optical diagnostic techniques were used to study the production of highly ionized species in aluminum plasma produced by a centered-triggered high-current pulsed cathodic arc. Controlling the spacing between cathode spots enabled a correlation between a reduction in the mean charge state and an increase in the spacing of cathode spots to be observed. As the cathode current was increased, the distances between spots were reduced and these charge states were produced for longer times. Strong cathode spot coupling is proposed as a mechanism for the production of high charge states.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chirped pulse shadowgraphy for single shot time resolved plasma expansion measurements

The dynamics of ultrashort laser plasmas demand single shot temporal measurements on fast time scales. We describe a method to record the plasma expansion on picosecond (ps) timescales continuously over hundreds of ps, in single shot. The method uses the chirp of a Ti:sapphire laser as a time-resolved optical diagnostic tool. Using this technique, the evolution of the plasma expansion had been recorded with ps time resolutions, by probing with a chirped laser pulse of 200 ps duration. A peak expansion velocity of 1.8x10{sup 7} cm/s is observed and its evolution in time is obtained for approx300 ps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Half Life of {sup 101}Mo and {sup 101}Tc beta{sup -}-decay

In this work, the half-life of the {sup 155}Sm beta{sup -} decay was determined using enriched {sup 154}Sm samples submitted to irradiation in the IEA-R1 reactor of IPEN; the activity of the samples were followed for 4-5 consecutive half lives using a 198 cm{sup 3} HPGe detector. The data was corrected using a non paralizable dead time correction and fitted to an exponential decay function using a non linear fitting procedure developed on the MatLab platform. The resulting value--T{sub 1/2} = 22.180(26) min--was compatible to the one found in the literature, with a lower uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Double streamer phenomena in atmospheric pressure low frequency corona plasma

Time-resolved images of an atmospheric pressure corona discharge, generated at 50 kHz in a single pin electrode source, show unique positive and negative corona discharge features: a streamer for the positive period and a glow for the negative period. However, unlike in previous reports of dc pulse and low frequency corona discharges, multistreamers were observed at the initial time stage of the positive corona. A possible physical mechanism for the multistreamers is suggested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical limits of semiconductor laser operation: A time-resolved analysis of catastrophic optical damage

The early stages of catastrophic optical damage (COD) in 808 nm emitting diode lasers are mapped by simultaneously monitoring the optical emission with a 1 ns time resolution and deriving the device temperature from thermal images. COD occurs in highly localized damage regions on a 30 to 400 ns time scale which is determined by the accumulation of excess energy absorbed from the optical output. We identify regimes in which COD is avoided by the proper choice of operation parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-situ lattice-strain analysis of a ferroelectric thin film under an applied pulse electric field

We developed an in-situ measurement system for characterizing the relationship between ferroelectricity and lattice distortion of a ferroelectric thin film at BL13XU, SPring-8. The dielectric polarization obtained and the lattice strain evaluated provide us with the electrostrictive coefficient of the film. The system for the method consists of a refractive lens for two dimensional micron focusing, ferroelectric characterization system, high-precision four-circle diffractometer, and time-resolved photon counting system. It enables in-situ measurements of the electric polarization of the film and an electric-field-induced strain using nano-second order time-resolved synchrotron diffraction. We applied the method to determining the lattice constant distorted by the electric field and the polarization value of a 410 nm-thick BiFeO{sub 3} thin film. The piezoelectric constant d{sub 33} evaluated was about 28 pm/V. The polarization observed allowed us to evaluate an electrostrictive coefficient Q of 1{center_dot}4x10{sup -2} m{sup 4}/C{sup 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New Developments in Femtosecond Soft X-ray Spectroscopy

Recent instrumentation developments in X-ray spectroscopy for ultra-fast time-resolved measurements with soft X-rays done in HZB Berlin during the last years are described. The significant performance improvements achieved this way are based on Fresnel diffraction from structures being fabricated on a surface of a total externally reflecting mirror. The first type of this spectrometer, an off-axis reflection zone plate, has been implemented at the BESSY Femtoslicing setup and shows on the order of 20 times higher flux in the focal plane compared to the classical grating monochromator beamline. It has proven to serve very precise experiments with a time resolution down to 100 fs on magnetic materials after optical laser pulse excitation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time Resolved Detectors and Measurements for Accelerators and Beamlines at the Australian Synchrotron

Time resolved experiments require precision timing equipment and careful configuration of the machine and the beamline. The Australian Synchrotron has a state of the art timing system that allows flexible, real-time control of the machine and beamline timing parameters to target specific electron bunches. Results from a proof-of-principle measurement with a pulsed laser and a streak camera on the optical diagnostic beamline will be presented. The timing system was also used to fast trigger the PILATUS detector on an x-ray beamline to measure the fill pattern dependent effects of the detector. PILATUS was able to coarsely measure the fill pattern in the storage ring which implies that fill pattern intensity variations need to be corrected for when using the detector in this mode.

43 PARTICLE ACCELERATORS↗

Pump-probe X-ray Diffraction Technique for Irreversible Phase Change Materials

We have developed a pump-probe X-ray diffraction measurement system for a sample with irreversible reaction at BL40XU in the SPring-8. The system mainly consists of a time-resolved measurement system, a sample disk rotation system, and an X-ray microbeam system. The time-resolved measurement system gives time resolution of 50 ps in laser-pump and X-ray probe method. A sample disk rotation system for repetitive measurements was made to give a virgin sample for every measurement. The number of repetitions for one sample disk was increased by using the X-ray microbeam technique. To keep the overlap of the X-ray microbeam and the laser beam on the sample surface during the disk rotation, the sample disk rotation system was constructed by a low-eccentric spindle motor. By using this system, the pump-probe X-ray diffraction measurement was demonstrated for a crystallization process of a DVD material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The dedicated QEXAFS facility at the SLS: Performance and Scientific Opportunities

The SuperXAS beamline at the Swiss Light Source (SLS) features a permanently installed monochromator for quick scanning EXAFS (QEXAFS) spectroscopy in series with a conventional double crystal monochromator (DCM). All installed optical components like collimating and focussing mirrors can be used by both devices. The remote exchange of the monochromators is possible in less than five minutes while maintaining the beam geometry on the sample. The QEXAFS system allows fast absorption scans down to the millisecond range for the investigation of time dependent processes. Using a Si(111) channel cut crystal the energy range from 5-16 keV can be covered, with a Si(311) cut the range 9.5-30 keV. Usually a quick scanning interval of 0.1 deg. - 2 deg. in Bragg angle is selected, thus covering XANES, full EXAFS or multiple edge scans of e.g. all L-edges of a heavy element. Up to about 80 spectra per second can be collected, corresponding to a time resolution of 12.5 ms. The high intensity of the beamline even facilitates fluorescence measurements on dilute samples.

43 PARTICLE ACCELERATORS↗

Medipix3 array high performance read-out board for synchrotron research

The Medipix3 ASIC is one of the most advanced chip that is presently available to build photon counting area detectors. The capabilities of the chip include adjacent pixels charge summing circuitry to sort out the distortion due to charge sharing, simultaneous counting and read-out that enables frames to be acquired without dead time, the colour mode of operation that enables up to eight energy bands to be acquired. In order to fully exploit the capabilities of the Medipix3 chip in synchrotron research, a high performance electronic board capable of driving large arrays of chips is necessary. We propose a parallel read-out board of Medipix3 chip arrays with a scalable architecture that allows driving the Medipix3 chip in all of its modes of operation. The board functions include the control of the chip arrays, data formatting and data compression, the management of the communications with the data storage devices, and operation in various trigger modes. In addition to this the board will have some 'intelligence' embedded. This will add some very important features to the final detector such as pattern recognition, capability of variable frame duration as a function of the photon flux, feedback to other equipment and real time calculations of data relevant to experiments such as the autocorrelation function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Precision Time Delay Control with Continuous Phase Shifter for Pump-Probe Experiments Using Synchrotron Radiation Pulses

Brilliant pulsed x-ray synchrotron radiation (SR) is useful for pump-probe experiment such as time-resolved x-ray diffraction, x-ray absorption fine structure, and x-ray spectroscopy. For laser pump-SR x-ray probe experiments, short pulsed lasers are generally synchronized to the SR master oscillator controlling the voltage for acceleration of electron bunches in an accelerator, and the interval between the laser and the SR pulses is changed around the time scale of target phenomenon. Ideal delay control produces any time delay as keeping the time-precision and pointing-stability of optical pulses at a sample position. We constructed the time delay control module using a continuous phase shifter of radio frequency signal and a frequency divider, which can produce the delayed trigger pulses to the laser without degradation of the time precision and the pointing stability. A picoseconds time-resolved x-ray diffraction experiment was demonstrated at SPring-8 storage ring for fast lattice response by femtosecond pulsed laser irradiation, and suggested the possibility of accurate sound velocity measurement. A delay control unit operating with subpicosecond precision has also been designed for femtosecond pump-probe experiments using a free electron laser at SPring-8 campus.

43 PARTICLE ACCELERATORS↗

Two-photon resonances in femtosecond time-resolved four-wave mixing spectroscopy: {beta}-carotene

Femtosecond time-resolved pump-degenerate four-wave mixing (pump-DFWM) spectroscopy has been used to study the ultrafast dynamics of {beta}-carotene involving several electronic and vibrational states. An initial pump pulse, resonant with the S{sub 0}-to-S{sub 2} transition, excites the molecular system and a DFWM process, resonant with the S{sub 1}-to-S{sub n} transition, is used to probe the relaxation pathways. The transient shows a peculiar decay behavior, which is due to the contributions of resonant DFWM signal of the excited S{sub 1} state, nonresonant DFWM signal of the ground S{sub 0} state and vibrational hot S{sub 0}{sup *} state, and the two-photon resonant DFWM signal of the ground S{sub 0} state. We have used a kinetic model including all the signal contributions to successfully fit the transient. The time constants extracted are in very good agreement with the known values for {beta}-carotene. For comparison, a two-pulse pump-probe experiment was performed measuring the transient absorption at the wavelength of the DFWM experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved investigation of dual high power impulse magnetron sputtering with closed magnetic field during deposition of Ti-Cu thin films

Time-resolved comparative study of dual magnetron sputtering (dual-MS) and dual high power impulse magnetron sputtering (dual-HiPIMS) systems arranged with closed magnetic field is presented. The dual-MS system was operated with a repetition frequency 4.65 kHz (duty cycle {approx_equal}50%). The frequency during dual-HiPIMS is lower as well as its duty cycle (f=100 Hz, duty 1%). Different metallic targets (Ti, Cu) and different cathode voltages were applied to get required stoichiometry of Ti-Cu thin films. The plasma parameters of the interspace between magnetrons in the substrate position were investigated by time-resolved optical emission spectroscopy, Langmuir probe technique, and measurement of ion fluxes to the substrate. It is shown that plasma density as well as ion flux is higher about two orders of magnitude in dual-HiPIMS system. This fact is partially caused by low diffusion of ionized sputtered particles (Ti{sup +},Cu{sup +}) which creates a preionized medium.

36 MATERIALS SCIENCE↗

Development of the Fast Scintillation Detector with Programmable High Voltage Adjustment Suitable for Moessbauer Spectroscopy

This work is focused on a development of a compact fast scintillation detector suitable for Moessbauer spectroscopy (low energy X-ray/{gamma}-ray detection) where high counting rates are inevitable. Optimization of this part was necessary for a reliable function, better time resolution and to avoid a detector pulses pile-up effect. The pile-up effect decreases the measurement performance, significantly depends on the source activity and also on the pulse duration. Our new detection unit includes a fast scintillation crystal YAP:Ce, an R6095 photomultiplier tube, a high voltage power supply socket C9028-01 assembly, an AD5252 digital potentiometer with an I2C interface and an AD8000 ultra fast operation preamplifier. The main advantages of this solution lie in a short pulse duration (less than 200 ns), stable operation for high activities, programmable gain of the high voltage supply and compact design in the aluminum housing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of X-Ray Telescopes for eROSITA and IXO

We report on the development of a generic X-ray instrument simulator to be used in simulations of future X-ray missions. Based on a Monte Carlo approach the code generates photon events for sources in an X-ray source catalogue such as the ROSAT all sky survey or the XMM-Newton slew surveys and then models the imaging and detection process based on the available calibration files (e.g., point spread functions for the imaging). The output of the program are event lists, which can be analysed using standard software such as xselect. Due to its modular concept the simulation software can be easily adapted to different concepts of imaging detectors.As examples for the potential use of the simulation we present our studies for eROSITA and show results of simulations of the detector performance for the High Time Resolution Spectrometer and the Wide Field Imager on the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗