Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Kinetic temperatures of iron ions in the solar wind observed with STEREO/PLASTIC

STEREO/PLASTIC provides detailed information on the three-dimensional velocity distributions of solar wind iron ions with a time resolution of 5 minutes. In general the distributions at 1 AU contain complicated structures showing persistence over several records, i.e., over intervals of up to 30 minutes, but no clear correlation of the properties of these distributions with the direction of the ambient magnetic field is evident. We have performed a statistical analysis using nearly 9000 observations. Iron ions follow the same trends as protons, alpha particles, and electrons: The ratio T{sub perpendicular}/T{sub ||} seems to be limited by the ion cyclotron instability, whereas T{sub ||} /T{sub perpendicular} is bounded by the firehose instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance study of single undoped CsI crystals for the Mu2e experiment

The Mu2e experiment at Fermilab aims to measure the neutrinoless muon-to-electron conversion, which is a charged-lepton flavor-violating process. The goal of the experiment is to reach a single event sensitivity of 2.5 × 10 -17 , to set an upper limit on the muon conversion rate at 6.7 × 10 -17 in a three-year run. For this purpose, the Mu2e detector is designed to identify electrons from muon conversion and reduce the background to a negligible level. It consists of a low-mass straw tracker and a pure CsI crystal calorimeter. In this paper, the performance of undoped CsI single crystal is reported. Crystals from many vendors have been characterized by determining their Light Yield (LY) and Longitudinal Response Uniformity (LRU), when read with a UV extended PMT, and their time resolution when coupled to a silicon photomultiplier. The crystals show a LY of ~100 photoelectrons per MeV when wrapped with Tyvek and coupled to the PMT without optical grease. The LRU is well represented by a linear slope that is on average 0.6%/cm. Both measurements have been performed using a 22 Na source. The timing performance has been evaluated exploiting cosmic rays, with MPPC readout. A timing resolution lower than 400 ps has been achieved (at ~20 MeV, which is the energy released by a minimum ionizing particle in the crystal).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Gas Chromatography with High-Resolution Time-of-Flight Mass Spectrometry Methodology for BDNPA/F

Analysis of thermally labile compounds such as bis(2,2-dinitropropyl) acetal/formal (BDNPA/F), an energetic plasticizer, is usually performed via liquid chromatography (LC) as opposed to gas chromatography (GC) due to thermal decomposition in the inlet or the analytical column. While LC is a powerful technique, the analysis of volatile and semivolatile compounds is best suited to GC. Herein, a method was developed for a gas chromatograph coupled to high-resolution mass spectrometer (GC-HRMS), utilizing a programmable temperature vaporizer (PTV) inlet. A subset of the native compounds and several produced by the thermal decomposition of BDNPA/F in the inlet were evaluated by using multiple PTV inlet parameters to determine the optimal ramp rate and final temperature of the inlet (60 °C/min from 60 to 325 °C). The optimized GC-HRMS method nearly reduced all thermal decomposition, allowing for an excellent separation to be obtained. Furthermore, multiple ionization methods, including electron impact (EI), negative chemical ionization (NCI), and positive chemical ionization (PCI), were used to explore the many chemical differences between the BDNPA/F samples. A preliminary investigation of the benefits of using GC-HRMS to evaluate the chemical differences between unaged and aged BDNPA/F samples for unique insight was evaluated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scanning cross-correlator for monitoring uniform 3D ellipsoidal laser beams

The specific features of experimental implementation of a cross-correlator with a scan rate above 1600 cm s{sup -1} and a spatial delay amplitude of more than 15 mm are considered. The possibility of measuring the width of femtosecond pulses propagating in a train 300 μs in duration with a repetition rate of 1 MHz is demonstrated. A time resolution of 300 fs for the maximum time window of 50 ps is attained. The cross-correlator is aimed at testing 3D pulses of a laser driver of an electron photo-injector. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Burst-mode dual-comb spectroscopy

We introduce a new modality of dual-comb spectroscopy that enables a simplified and powerful new approach for time-resolved measurements with increased acquisition rates. This "burst mode" form of dual-comb spectroscopy (BM-DCS) relies on the multiplexing of each probe pulse into a short train of pulses. With this approach we demonstrate a time-resolved series of absorption-based spectroscopic measurements of a laser-induced plasma using only a single laser ablation shot and identify 22 Nd lines not previously reported in the literature. The transmission spectra spanned 3.1 THz and were acquired at an effective acquisition rate of 25 kHz with 40 ms time-resolution. This simple modification to 100 MHz level dual-comb systems provides a flexible approach for studying transient and low duty-cycle events such as laser-induced plasmas, combustion, and explosive reactions.

(280.5395) Plasma Diagnostics, broadband laser spe↗

Sensitive and single-shot OH and temperature measurements by femtosecond cavity-enhanced absorption spectroscopy

In many low-temperature plasmas (LTPs), the OH radical and temperature represent key properties of plasma reactivity. However, OH and temperature measurements in weakly ionized LTPs are challenging, due to the low concentration and short lifetime of OH and the abrupt temperature rise caused by fast gas heating. To address such issues, this Letter combined cavity-enhanced absorption spectroscopy (CEAS) with femtosecond (fs) pulses to enable sensitive single-shot broadband measurements of OH and temperature with a time resolution of ∼180 ns in LTPs. Such a combination leveraged several benefits. With the appropriately designed cavity, an absorption gain of ∼66 was achieved, enhancing the actual OH detection limit by ∼55× to the 10 11 cm -3 level (sub-ppm in this work) compared with single-pass absorption. Single-shot measurements were enabled while maintaining a time resolution of ∼180 ns, sufficiently short for detecting OH with a lifetime of ∼100 μs. With the broadband fs laser, ∼34,000 cavity modes were matched with ∼95 modes matched on each CCD pixel bandwidth, such that fs-CEAS became immune to the laser-cavity coupling noise and highly robust across the entire spectral range. Also, the broadband fs laser allowed simultaneous sensing of many absorption features to enable simultaneous multi-parameter measurements with enhanced accuracies.

Liu, Ning↗

Fast Plasma Instrument for MMS: Simulation Results

Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. The Dual Electron Spectrometer (DES) of the Fast Plasma Instrument (FPI) for MMS meets these demanding requirements by acquiring the electron velocity distribution functions (VDFs) for the full sky with high-resolution angular measurements every 30 ms. This will provide unprecedented access to electron scale dynamics within the reconnection diffusion region. The DES consists of eight half-top-hat energy analyzers. Each analyzer has a 6 deg. x 11.25 deg. Full-sky coverage is achieved by electrostatically stepping the FOV of each of the eight sensors through four discrete deflection look directions. Data compression and burst memory management will provide approximately 30 minutes of high time resolution data during each orbit of the four MMS spacecraft. Each spacecraft will intelligently downlink the data sequences that contain the greatest amount of temporal structure. Here we present the results of a simulation of the DES analyzer measurements, data compression and decompression, as well as ground-based analysis using as a seed re-processed Cluster/PEACE electron measurements. The Cluster/PEACE electron measurements have been reprocessed through virtual DES analyzers with their proper geometrical, energy, and timing scale factors and re-mapped via interpolation to the DES angular and energy phase-space sampling measurements. The results of the simulated DES measurements are analyzed and the full moments of the simulated VDFs are compared with those obtained from the Cluster/PEACE spectrometer using a standard quadrature moment, a newly implemented spectral spherical harmonic method, and a singular value decomposition method. Our preliminary moment calculations show a remarkable agreement within the uncertainties of the measurements, with the results obtained by the Cluster/PEACE electron spectrometers. The data analyzed was selected because it represented a potential reconnection event as currently published.

Figueroa-Vinas, Adolfo↗

Dynamics and Origin of Extra-solar Planetary Systems and Microlensing Detection of Extra-solar Planets

We compare a space-based microlensing search for planets, with a ground based microlensing search originally proposed by D. Tytler (Beichman, et al. 1996). Perturbations of microlensing light curves when the lens star has a planetary companion are sought by one wide angle survey telescope and an array of three or four followup narrow angle telescopes distributed in longitude that follow events with high precision, high time resolution photometry. Alternative ground based programs are considered briefly. With the four 2 meter telescopes distributed in longitude in the southern hemisphere in the Tytler proposal, observational constraints on a ground-based search for planets during microlensing events toward the center of the galaxy are severe. Probably less than 100 events could be monitored per year with high precision, high time resolution photometry with only about 42% coverage on the average regardless of how many events were discovered by the survey telescope. Statistics for the occurrence and properties for Jupiter-mass planets would be meaningful but relatively meager four years after the program was started, and meaningful statistics for Earth-mass planets would be non existent. In contrast, the 14,500 events in a proposed 4 year space based program (GEST = Galactic Exoplanet Survey Telescope) would yield very sound statistics on the occurrence, masses and separations of Jupiter-mass planets, and significant constraints on similar properties for Earth-mass planets. The significance of the Jupiter statistics would be to establish the frequency of planetary systems like our own, where terrestrial planets could exist inside the orbits of the giants.

Peale, S. J.↗

MULTI-TECHNIQUE APPROACH TO MEASURE SIZE AND TIME RESOLVED ATMOSPHERIC AND RADIONUCLIDE AEROSOLS

Accurate quantifications of aerosol components are crucial to predict global atmospheric transport models. Recently developed International Monitoring System (IMS) network represents an opportunity to enhance comprehensive systematic aerosol observations on a global scale because it provides a global infrastructure. As such, a local pilot study utilizing several state-of-the-art instruments has been conducted at the peak of Rattlesnake Mountain, Washington, USA, during three month periods (June-August) in 2003 to explore this opportunity. In this study, routine aerosol samples were collected using a 3-stage Cascade Impactor Beam Analyzer (0.07 to 2.5 µm) with time resolution about 6 hours on long Teflon strips while radionuclide aerosols were collected using Radionuclide aerosol sampler/analyzer (RASA) developed at Pacific Northwest National Laboratory. The elemental composition and hydrogen concentration were measured using proton induced x-ray emission (PIXE) and proton elastic scattering analysis (PESA), respectively. In addition, short and long-lived radionuclides that exist in nature were measured with same time resolution (6 hours) using RASA. In this method, high-resolution gamma-ray spectra were analyzed for radionuclide concentration. Combination of trace radioactive and non-radioactive element analysis in aerosols makes this investigation unique.

Shutthanandan, V↗

Progress of neutral-beam-aided diagnostics on the HL-2A tokamak

A 32/64-channel Charge eXchange Recombination Spectroscopy (CXRS) and a 7-channel motional Stark effect (MSE) polarimeter have been developed on the HL-2A tokamak. To extract the maximum time resolution of the system, the incidence fibers of the spectrometer are pitch-controlled; and the double-slit fiber bundle can increase the spatial channels with one charge-coupled device detector. The ion temperature and plasma rotation with time and spatial resolutions up to 5 ms and 1 cm are obtained. Sawtooth oscillation, transition from intermediate phase (I phase) to high confinement mode (H mode) can be clearly observed by the CXRS. The spectrometer can be utilized as the main component of the MSE polarimeter, which can effectively overcome the weak Stark effect. The pitch angles of magnetic field are obtained for 7 spatial points covering 24 cm along major radius with time resolution of 40 ms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relationship of Interplanetary Shock Micro and Macro Characteristics: A Wind Study

The non-linear least squared MHD fitting technique of Szabo 11 9941 has been recently further refined to provide realistic confidence regions for interplanetary shock normal directions and speeds. Analyzing Wind observed interplanetary shocks from 1995 to 200 1, macro characteristics such as shock strength, Theta Bn and Mach numbers can be compared to the details of shock micro or kinetic structures. The now commonly available very high time resolution (1 1 or 22 vectors/sec) Wind magnetic field data allows the precise characterization of shock kinetic structures, such as the size of the foot, ramp, overshoot and the duration of damped oscillations on either side of the shock. Detailed comparison of the shock micro and macro characteristics will be given. This enables the elucidation of shock kinetic features, relevant for particle energization processes, for observations where high time resolution data is not available. Moreover, establishing a quantitative relationship between the shock micro and macro structures will improve the confidence level of shock fitting techniques during disturbed solar wind conditions.

Szabo, Adam↗

Automated imaging of the annihilation of a transverse domain wall in patterned magnetic thin films

Imaging the magnetic domain wall behavior in patterned thin films under external stimuli can enable understanding the underlying energy landscape and the role of local microstructure and defects. We present an automated workflow for in situ Lorentz transmission electron microscopy to image magnetic domain walls at the nanometer length scale and at a time resolution in the sub-millisecond regime—the latter of which is limited by the speed of the available camera. Our workflow is modular and can be broadly applied to various types of in situ experiments, taking us a step closer to the future of autonomous imaging of nanomagnetic films with electron microscopy. Using our workflow, we show the transformation of a transverse domain wall with sub-millisecond time resolution under the application of an in situ transverse magnetic field, a study of whose dynamics are essential in the design of future domain wall mediated spintronic device applications.

Algebraic topology↗

Studying AC-LGAD strip sensors from laser and testbeam measurements

Here, this paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration methodology. The results were compared to those obtained with a 120 GeV proton beam. Despite the differences in the charge deposition mechanism between the laser and proton beam, the spatial and temporal resolutions were found to be compatible between the two sources after calibration. With 4D tracking detectors expected to play a vital role in upcoming collider experiments, we foresee this work as a way to evaluate the performance of semiconductor sensors that can augment testbeam measurements and accelerate R&D efforts. Additionally, simulation studies using Silvaco TCAD and Weightfield2 were carried out to understand the various contributing factors to the total time resolution in AC-LGAD sensors, measured using the laser source.

FOS: Physical sciences↗

Effect of filtering on noise and timing in nuclear particle detection

The relations between signal shaping, noise, and timing resolution in nuclear particle detection systems are examined in this paper. Mathematical analysis of five commonly used types of filters leads to numerical results for system noise components arising from sources in the preamplifier, detector, and bias resistors. These results are presented in the form of design curves for the various filters, showing the dependence of each output noise component on both the magnitude of the noise sources and the filter time constants. Three of the filters considered are simple RC types; the remaining two are combinations of delay lines and RC elements. The quantitative calculations specifically assume a silicon detector and a field-effect-transistor preamplifier. Those filters that exhibit bipolar step response are analyzed in terms of crossover timing resolution, based on the earlier noise calculations. Again, the results are summarized in sets of design curves for each filter. Finally, the comparative performance of the various filter types is discussed, and specific examples are given.

Gary, S. A.↗

Characterization of ORNL PSD ASIC

The performance of the ORNL ASIC and its readout system was tested with pixelated organic scintillators. We use a pixelated trans-Stilbene scintillator array from Inrad Optics and a pixelated organic glass scintillator array developed at Sandia National Laboratories to characterize the energy and timing resolutions and the pulse-shape discrimination (PSD) figure-of-merit (FoM). The results are compared to previous work in which the same metrics were measured on waveforms digitized at 250 MHz with 14-bit resolution. We found that the PSD FoM at 340 keVee of the ASIC configuration compared to waveform data varied with the scintillator type. We measured a PSD FoM of 1.12 ± 0.14 with the ASIC configuration versus 1.39 ± 0.23 with waveform data using the trans-Stilbene array. We measured a PSD FoM of 0.52 ± 0.18 with the ASIC configuration versus 1.25 ± 0.19 with waveform data using the the organic glass scintillator array. The coincidence timing resolution was measured using two 6x6x6 mm 3 cubes of trans-Stilbene. It was measured to be 805 ± 9 ps with the ASIC configuration versus 300 ps on average with waveform data.

42 ENGINEERING↗

EASTERN NORTH ATLANTIC (ENA) CONDENSATION PARTICLE COUNTER (CPC) with the AEROSOL MASK (ENA-AM) for the YEAR 2017

The Eastern North Atlantic (ENA) central facility is periodically affected by episodes of local aerosols. High-concentration aerosol events associated with potential local aerosol sources are sampled by the Concentration Particle Counter (CPC) and can be observed in the high-time-resolution data. In an effort to remove aerosol data that is not regionally representative from the CPC data, an aerosol mask (ENA-AM) has been previously developed and validated during the ACE-ENA campaing (Gallo et al., 2020). The ENA-AM is a standard deviation algorithm based on the statistically different behavior of adjacent data points used to determine periods when the measurements are impacted by local aerosols. This file contain one-minute time resolution submicron aerosol particle concentration datasets from the CPC for the year 2017, and the corresponding ENA-AM datasets to remove datapoints affected by local aerosol sources.

54 ENVIRONMENTAL SCIENCES↗

EASTERN NORTH ATLANTIC (ENA) CONDENSATION PARTICLE COUNTER (CPC) with the AEROSOL MASK (ENA-AM) for the YEAR 2018

The Eastern North Atlantic (ENA) central facility is periodically affected by episodes of local aerosols. High-concentration aerosol events associated with potential local aerosol sources are sampled by the Concentration Particle Counter (CPC) and can be observed in the high-time-resolution data. In an effort to remove aerosol data that is not regionally representative from the CPC data, an aerosol mask (ENA-AM) has been previously developed and validated during the ACE-ENA campaing (Gallo et al., 2020). The ENA-AM is a standard deviation algorithm based on the statistically different behavior of adjacent data points used to determine periods when the measurements are impacted by local aerosols. This file contain one-minute time resolution submicron aerosol particle concentration datasets from the CPC for the year 2018, and the corresponding ENA-AM datasets to remove datapoints affected by local aerosol sources.

54 ENVIRONMENTAL SCIENCES↗