Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Cyclic spectroscopy of the millisecond pulsar, B1937+21

Cyclic spectroscopy is a signal processing technique that was originally developed for engineering applications and has recently been introduced into the field of pulsar astronomy. It is a powerful technique with many attractive features, not least of which is the explicit rendering of information about the relative phases in any filtering imposed on the signal, thus making holography a more straightforward proposition. Here we present methods for determining optimum estimates of both the filter itself and the statistics of the unfiltered signal, starting from a measured cyclic spectrum. In the context of radio pulsars these quantities tell us the impulse response of the interstellar medium (ISM) and the intrinsic pulse profile. We demonstrate our techniques by application to 428 MHz Arecibo data on the millisecond pulsar B1937+21, obtaining the pulse profile free from the effects of interstellar scattering. As expected, the intrinsic profile exhibits main- and inter-pulse components that are narrower than they appear in the scattered profile; it also manifests some weak, but sharp, features that are revealed for the first time at low frequency. We determine the structure of the received electric field envelope as a function of delay and Doppler shift. Our delay Doppler image has a high dynamic range and displays some pronounced, low-level power concentrations at large delays. These concentrations imply strong clumpiness in the ionized ISM, on AU-size scales, which must adversely affect the timing of B1937+21.

79 ASTRONOMY AND ASTROPHYSICS↗

SFAI and Related Technologies

Researchers at Los Alamos have developed Swept-Frequency Acoustic Interferometry (SFAI) a technology that enables businesses to have greater control over their industrial processes, allowing for significantly improved efficiency by giving operators vital composition and flow rate information in real-time. This technology fills the information gap by providing this data non-invasively and at a fraction of the cost of traditional composition meters. SFAI uses engineered ultrasound and advanced signal processing to characterize multiphase flow (e.g., liquids, gasses, multi-phase mixtures) and other flows inside sealed containers and flow pipes. By being both low-cost and non-invasive, this technology is set to disrupt the current oil field monitoring state-of-the-art by providing individual well-level composition data, compared to the multi-well macroscopic information that is currently available. We are seeking a commercialization partner to license the technology or fund us through a Cooperative Research and Development Agreement (CRADA) to a further develop a usable product for commercial purposes.

03 NATURAL GAS↗

Advances in Machine and Deep Learning for Modeling and Real-time Detection of Multi-Messenger Sources

We live in momentous times. The science community is empowered with an arsenal of cosmic messengers to study the universe in unprecedented detail. Gravitational waves, electromagnetic waves, neutrinos, and cosmic rays cover a wide range of wavelengths and timescales. Combining and processing these datasets that vary in volume, speed, and dimensionality requires new modes of instrument coordination, funding, and international collaboration with a specialized human and technological infrastructure. In tandem with the advent of large-scale scientific facilities, the last decade has experienced an unprecedented transformation in computing and signal-processing algorithms. The combination of graphics processing units, deep learning, and the availability of open source, high-quality datasets has powered the rise of artificial intelligence. This digital revolution now powers a multibillion dollar industry, with far-reaching implications in technology and society. In this chapter, we describe pioneering efforts to adapt artificial intelligence algorithms to address computational grand challenges in multi-messenger astrophysics. We review the rapid evolution of these disruptive algorithms, from the first class of algorithms introduced in early 2017 to the sophisticated algorithms that now incorporate domain expertise in their architectural design and optimization schemes. We discuss the importance of scientific visualization and extreme-scale computing in reducing time-to-insight and obtaining new knowledge from the interplay between models and data.

Artificial Intelligence↗

Demonstrating the Potential of Adaptive LMS Filtering on FPGA-Based Qubit Control Platforms for Improved Qubit Readout in 2D and 3D Quantum Processing Units

Advancements in quantum computing underscore the critical need for sophisticated qubit readout techniques to accurately discern quantum states. This abstract presents our research intended for optimizing readout pulse fidelity for 2D and 3D Quantum Processing Units (QPUs), the latter coupled with Superconducting Radio Frequency (SRF) cavities. Focusing specifically on the application of the Least Mean Squares (LMS) adaptive filtering algorithm, we explore its integration into the FPGA-based control systems to enhance the accuracy and efficiency of qubit state detection by improving Signal-to-Noise Ratio (SNR). Implementing the LMS algorithm on the Zynq UltraScale+ RFSoC Gen 3 devices (RFSoC 4x2 FPGA and ZCU216 FPGA) using the Quantum Instrumentation Control Kit (QICK) open-source platform, we aim to dynamically test and adjust the filtering parameters in real-time to characterize and adapt to the noise profile presented in quantum computing readout signals. Our preliminary results demonstrate the LMS filter's capability to maintain high readout accuracy while efficiently managing FPGA resources. These findings are expected to contribute to developing more reliable and scalable quantum computing architectures, highlighting the pivotal role of adaptive signal processing in quantum technology advancements.

Johnson, Hans↗

Demonstrating the Potential of Adaptive LMS Filtering on FPGA-Based Qubit Control Platforms for Improved Qubit Readout in 2D and 3D Quantum Processing Units

Advancements in quantum computing underscore the critical need for sophisticated qubit readout techniques to accurately discern quantum states. This abstract presents our research intended for optimizing readout pulse fidelity for 2D and 3D Quantum Processing Units (QPUs), the latter coupled with Superconducting Radio Frequency (SRF) cavities. Focusing specifically on the application of the Least Mean Squares (LMS) adaptive filtering algorithm, we explore its integration into the FPGA-based control systems to enhance the accuracy and efficiency of qubit state detection by improving Signal-to-Noise Ratio (SNR). Implementing the LMS algorithm on the Zynq UltraScale+ RFSoC Gen 3 devices (RFSoC 4x2 FPGA and ZCU216 FPGA) using the Quantum Instrumentation Control Kit (QICK) open-source platform, we aim to dynamically test and adjust the filtering parameters in real-time to characterize and adapt to the noise profile presented in quantum computing readout signals. Our preliminary results demonstrate the LMS filter's capability to maintain high readout accuracy while efficiently managing FPGA resources. These findings are expected to contribute to developing more reliable and scalable quantum computing architectures, highlighting the pivotal role of adaptive signal processing in quantum technology advancements.

Johnson, Hans↗

A generalized tool for accurate time-domain separation of excited modes in spin-torque oscillators

We propose and develop an advanced signal processing technique that, combined with micromagnetic simulations, is able to deeply describe the non-stationary behavior of spin-torque oscillators, both in terms of time domain and spatial distribution of the magnetization dynamics. The Hilbert-Huang Transform is used for the identification of the time traces of each oscillation in a multimode excitation and enhanced with masking signals and the Ensemble Empirical Mode Decomposition. We emphasize that the technique developed here is general and can be used for any physical non-linear system in the presence of multimode dynamical excitation or intermittence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development and Validation of a Polarimetric-MCScene 3D Atmospheric Radiation Model

Polarimetric measurements can substantially enhance the ability of both spectrally resolved and single band imagery to detect the proliferation of weapons of mass destruction, providing data for locating and identifying facilities, materials, and processes of undeclared and proliferant nuclear weapons programs worldwide. Unfortunately, models do not exist that efficiently and accurately predict spectral polarized signatures for the materials of interest embedded in complex 3D environments. Having such a model would enable one to test hypotheses and optimize both the enhancement of scene contrast and the signal processing for spectral signature extraction. The Phase I set the groundwork for development of fully validated polarimetric spectral signature and scene simulation models. This has been accomplished 1. by (a) identifying and downloading state-of-the-art surface and atmospheric polarimetric data sources, (b) implementing tools for generating custom polarimetric data, and (c) identifying and requesting US Government funded field measurement data for use in validation; 2. by formulating an approach for upgrading the radiometric spectral signature model MODTRAN to generate polarimetric intensities through (a) ingestion of the polarimetric data, (b) polarimetric vectorization of existing MODTRAN modules, and (c) integration of a newly developed algorithm for computing polarimetric multiple scattering contributions; 3. by generating an initial polarimetric model that demonstrates calculation of polarimetric solar and lunar single scatter intensities arising from the interaction of incoming irradiances with molecules and aerosols; 4. by developing a design and implementation plan to (a) automate polarimetric scene construction and (b) efficiently sample polarimetric scattering and reflection events, for use in a to be developed polarimetric version of the existing first-principles synthetic scene simulation model, MCScene; and 5. by planning a validation field measurement program in collaboration with the Remote Sensing and Exploitation group at Sandia National Laboratories (SNL) in which data from their ongoing polarimetric field and laboratory measurement program will be shared and, to the extent allowed, tailored for model validation in exchange for model predictions under conditions and for geometries outside of their measurement domain.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Assessment of global and gene-specific DNA methylation in rat liver and kidney in response to non-genotoxic carcinogen exposure

Altered expression of tumor suppressor genes and oncogenes, which is regulated in part at the level of DNA methylation, is an important event involved in non-genotoxic carcinogenesis. This may serve as a marker for early detection of non-genotoxic carcinogens. Therefore, we evaluated the effects of non-genotoxic hepatocarcinogens, 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), hexachlorobenzene (HCB), methapyrilene (MPY) and male rat kidney carcinogens, d-limonene, p-dichlorobenzene (DCB), chloroform and ochratoxin A (OTA) on global and CpG island promoter methylation in their respective target tissues in rats. No significant dose-related effects on global DNA hypomethylation were observed in tissues of rats compared to vehicle controls using LC–MS/MS in response to short-term non-genotoxic carcinogen exposure. Initial experiments investigating gene-specific methylation using methylation-specific PCR and bisulfite sequencing, revealed partial methylation of p16 in the liver of rats treated with HCB and TCDD. However, no treatment related effects on the methylation status of Cx32, e-cadherin, VHL, c-myc, Igfbp2, and p15 were observed. We therefore applied genome-wide DNA methylation analysis using methylated DNA immunoprecipitation combined with microarrays to identify alterations in gene-specific methylation. Under the conditions of our study, some genes were differentially methylated in response to MPY and TCDD, whereas d-limonene, DCB and chloroform did not induce any methylation changes. 90-day OTA treatment revealed enrichment of several categories of genes important in protein kinase activity and mTOR cell signaling process which are related to OTA nephrocarcinogenicity. - Highlights: • Studied non-genotoxic carcinogens caused no change on global DNA hypomethylation. • d-Limonene, DCB and chloroform did not show any genome-wide methylation changes. • Some genes were differentially methylated in response to MPY, TCDD and OTA. • Protein kinase activity and mTOR cell signaling are involved in OTA carcinogenicity. • Our data highlight Cpne4 may be a potential biomarker for non-genotoxic carcinogens.

60 APPLIED LIFE SCIENCES↗

Cold Electronics for Giant Liquid Argon Time Projection Chambers

The choice between cold and warm electronics (inside or outside the cryostat) in very large LAr TPCs (>5-10 ktons) is not an electronics issue, but it is rather a major cryostat design issue. This is because the location of the signal processing electronics has a direct and far reaching effect on the cryostat design, an indirect effect on the TPC electrode design (sense wire spacing, wire length and drift distance), and a significant effect on the TPC performance. All these factors weigh so overwhelmingly in favor of the cold electronics that it remains an optimal solution for very large TPCs. In this paper signal and noise considerations are summarized, the concept of the readout chain is described, and the guidelines for design of CMOS circuits for operation in liquid argon (at {approx}89 K) are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ADC evaluation boards design and test framework for LCLS-II precision receiver

In the low-level RF control field, ADC acquisition accuracy and noise set the boundary of our control ability, making it important to develop low-noise acquisition systems. From the design to test stage, all the noise terms should be understood and characterized. The specific need addressed here is the precision acquisition system for the second Linac Coherent Light Source (LCLS-II), led by SLAC National Accelerator Laboratory. Test circuit boards for the LTC2174 and AD9268 ADCs are designed and fabricated by LBNL. An ADC test framework based on FPGA evaluation board to assess performance has been developed. The ADC test framework includes both DSP (Digital Signal Processing) firmware and processing software. It is useful for low-level RF control and other synchronization projects. Investigating the clock jitter between two channels give us an understanding of that noise source. Working with the test framework, the raw ADC data are transferred to a computer through a Gigabit Ethernet interface. Then short-term error signal can be calculated based on a sine wave fit. By changing low-pass filter bandwidth, relative long-term performance can also be obtained. Amplitude jitter and differential phase jitter are the key issues for ADCs. This paper will report the test results for LTC2174 and AD9268 chips. The integral amplitude jitter is smaller than 0.003 %, and the integral phase noise is smaller than 0.0015° (measured at 47 MHz RF, 100 MHz clock, bandwidth 1 Hz to 100 kHz) for both ADC chips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

Design of an ultra low power CMOS pixel sensor for a future neutron personal dosimeter

Despite a continuously increasing demand, neutron electronic personal dosimeters (EPDs) are still far from being completely established because their development is a very difficult task. A low-noise, ultra low power consumption CMOS pixel sensor for a future neutron personal dosimeter has been implemented in a 0.35 {mu}m CMOS technology. The prototype is composed of a pixel array for detection of charged particles, and the readout electronics is integrated on the same substrate for signal processing. The excess electrons generated by an impinging particle are collected by the pixel array. The charge collection time and the efficiency are the crucial points of a CMOS detector. The 3-D device simulations using the commercially available Synopsys-SENTAURUS package address the detailed charge collection process. Within a time of 1.9 {mu}s, about 59% electrons created by the impact particle are collected in a cluster of 4 x 4 pixels with the pixel pitch of 80 {mu}m. A charge sensitive preamplifier (CSA) and a shaper are employed in the frond-end readout. The tests with electrical signals indicate that our prototype with a total active area of 2.56 x 2.56 mm{sup 2} performs an equivalent noise charge (ENC) of less than 400 e - and 314 {mu}W power consumption, leading to a promising prototype. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new architecture for fast ultrasound imaging

Some ultrasound imaging applications require high frame rate, for example 3D imaging and automated inspections of large components. Being the signal-processing throughput of the system the main bottleneck, parallel beamforming is required to achieve hundreds to thousands of images per second. Simultaneous A-scan line beamforming in all active channels is required to reach the intended high frame rate. To this purpose, a new parallel beamforming architecture that exploits the currently available processing resources available in state-of-the-art FPGAs is proposed. The work aims to get the optimal resource usage, high scalability and flexibility for different applications. To achieve these goals, the basic beamforming function is reformulated to be adapted to the DSP-cell architecture of state-of-the-art FPGAs. This allows performing simultaneous dynamic focusing on multiple A-scan lines. Some realistic examples are analyzed, evaluating resource requirements and maximum operating frequency. For example, a 128-channel system, with 128 scan lines and acquiring at 20 MSPS, can be built with 4 mid-range FPGAs, achieving up to 18000 frames per second, just limited by the maximum PRF. The gold standard Synthetic Transmit Aperture method (also called Total Focusing Method) can be carried out in real time at a processing rate of 140 high-resolution images per second (16 cm depth on steel)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mitochondrial dynamics coordinate cell differentiation

Highlights: • Mitochondrial fusion and fission are essential in mouse embryogenesis, and cell differentiation. • The mitochondrial shape changes in differentiation and dedifferentiation. • Mitochondrial dynamics act as a hub to consolidate intra-and-extracellular signals in cell differentiation. Cells differentiate into specific and functional lineages to build up tissues. It has been shown in several tissues that mitochondrial morphology, levels of “mitochondria-shaping” proteins, and mitochondrial functions change upon differentiation. In this review, we highlight the significance of mitochondrial dynamics and functions in tissue development, cell differentiation, and reprogramming processes. Signalling cascades are critical for tissue stem cell maintenance and cell fate determination, and growing evidence demonstrates mitochondria could act as a centre of intra and extracellular signals to coordinate signalling pathways, such as Notch, Wnt, and YAP/TAZ signalling. Just an organelle, however, emerges as a master regulator of cell differentiation, and can be a target to manipulate cell fates.

60 APPLIED LIFE SCIENCES↗

100 TeV pp collisions, SM type, PYTHIA8 generator: tev100pp_minbias_a2_pythia8_l3

MinBias events used to mix with signal processes. 60k events per file. Pythia8 Minimum bias (ND+SD+DD) sample with ATLAS MB Tune A2-MSTW2008LO tune, i.e. events include non-diffractive, single diffractive and double diffractive events. Events are slimmed with pT>0.4 GeV cut. The file uses low-precision varint 1000 ("l3") for length units to make it comparable with some signal files. Due to reduced precision for decay length, this file is smaller than the standard file with 10^4 units.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of a hybrid silicon-plasmonic co-propagating coupler operating close to coherent perfect absorption

By hybrid integration of plasmonic and dielectric waveguide concepts, it is shown that nearly perfect coherent absorption can be achieved in a co-propagating coupler geometry. First, the operating principle of the proposed device is detailed in the context of a more general 2 × 2 lossy coupler formalism. Then, it is shown how to tune the device in a wide region of possible working points, its broadband operation, and the tolerance to fabrication uncertainties. Finally, a complete picture of the electromagnetic modes inside the hybrid structure is analyzed, shining light onto the potentials which the proposed device holds in view of classical and quantum signal processing, nonlinear optics, polarization control, and sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of Hybrid K-Edge Densitometry in Reprocessing Facilities

During reprocessing operations, accurately determining the elemental concentrations of uranium and plutonium is critical for nuclear security. Reprocessing facilities processes hundreds of tons of nuclear material annually, requiring accurate measurements to ensure effective nuclear material control and accountability. Hybrid K-edge densitometry (HKED) system combines K-edge absorption densitometry with x-ray fluorescence to measure actinide elemental concentrations with a low uncertainty. This system uses high-purity germanium gamma-ray detectors and advanced signal processing equipment to detect x-ray accurately. This document provides guidance on how to achieve effective performance from an HKED system for measuring uranium and plutonium concentrations in reprocessing facilities. It includes best practices for the setup and operation of an HKED system, while highlighting factors influencing uncertainties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

100 TeV pp collisions, SM type, PYTHIA8 generator: tev100pp_minbias_a2_pythia8_nosl

MinBias events used to mix with signal processes. 60k events per file. Pythia8 Minimum bias (ND+SD+DD) sample with ATLAS MB Tune A2-MSTW2008LO tune, i.e. events include non-diffractive, single diffractive and double diffractive events. Events are slimmed with pT>0.4 GeV cut. No slimming. The file uses low-precision varint 1000 ("l3") for length units to make it comparable with some signal files. Due to reduced precision for decay length, this file is smaller than the standard file with 10^4 units.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗