Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sandstone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

CarbonSAFE Rocky Mountain Phase I: Ensuring Safe Subsurface Storage of Carbon Dioxide in the Intermountain West

An integrated CCS pre-feasibility study, CarbonSAF E Rocky Mountain Phase I, was conducted by the U niversity of Utah and its partners as part of the US D epartment of Energy’s Carbon Storage Assurance a nd Facility Enterprise (CarbonSAFE) program. The a ssembled project team consisted of academic, indus try and governmental agencies covering the technic al and non- technical challenges of a commercial-sc ale CO 2 storage facility capable of storing 50 million tonnes of anthropogenically-sourced CO 2 . The Rock y Mountain CarbonSAFE team identified the Hunter Power Plant in central Utah as the primary source of CO 2 on which this study would be focused. The nea rby Huntington power plant, also operated by Rocky Mountain Power, was evaluated as a secondary sou rce of CO 2 . The Hunter plant was chosen because o f an interest in CO 2 capture technology by the plant operator, Rocky Mountain Power, and also because i t is a representative example of a typical coal-fired g enerating station in the Rocky Mountain west. Amine -based and cryogenic-based capture assessments w ere performed for approximately 3 million tonnes per year for one of the boiler units at the Hunter plant, yi elding cost of capture estimates of $\$56$/tonne and $\$4 1.50$/tonne. Transportation and intermediate compre ssion would increase the per tonne costs, but will be highly dependent on specific injection locations and available rights-of-way. A high-level technical sub-ba sinal evaluation was performed on the area surround ing the Hunter and Huntington power plants to verify CO 2 storage capacity and integrity. Initial geologic c haracterization efforts focused on sites immediately adjacent to the Hunter plant, including the deep eolia n Permian White Rim Sandstone, which in outcrop a nd core from other locations indicates high permeabi lity and high porosity. However, petrophysical logs fr om wells near Hunter indicate porosity of only 2-4%. As a result, potential injection sites were moved stru cturally down-dip (to the west), into the high permea bility (~200 mD) and high porosity (20%) Navajo san dstone. A comprehensive analysis of the reservoir a nd seals was conducted, providing data to the model , simulation and risk assessment groups on the proje ct. CO 2 capacity estimates for the Navajo Sandston e approximately 18 kilometers from the Hunter plant are well in excess of the 50 million tonnes goal of the project. Area of Review Delineation and Risk Asse ssment on the Navajo, associated seals and shallow groundwater aquifers identified the most significant risks and mitigation options. A non-technical assessment to a commercial-scale CO 2 storage facility in central Utah was conducted. EPA Underground Injection Control Class VI and National Environmental Policy Act permitting present particularly challenging issues related to the development of any saline aquifer for CO 2 storage, including the area around the Hunter plant. While surface and subsurface ownership and ri ghts are not straightforward, especially on any privat e land, many of the stakeholders in central Utah are accustomed and open to oil/gas/mineral-related activities similar to what would be required for CO 2 storage sites.

01 COAL, LIGNITE, AND PEAT↗

Transportation Design and Products Specification (SECARB Phase III Work Product 6.2.2.a)

The SECARB Anthropogenic Test at the Citronelle oil field in Mobile County, Alabama is the largest fully integrated coal-fired carbon capture, transportation and storage project in the United States. Constructed and funded by Southern Company and Mitsubishi Heavy Industries, the CO 2 capture facility at Alabama Power’s 2,657-megawatt Plant Barry captures up to 500 metric tons of CO 2 per day, the equivalent emissions from 25 MW of the plant’s power generation. Captured CO 2 is transported to the mature Citronelle oil field atop a 16,380 acre (66.3 km2 of surface area), geologic salt dome. Citronelle oil field is operated by Denbury Onshore, LLC. The CO 2 is injected through ten perforated intervals in the injection well casing at depths ranging from 9,436 ft to 9,800 ft into the porous and permeable sandstones of the Paluxy Formation. This report describes the transportation design and product specifications for captured CO 2 transported from the capture facility to the underground storage reservoir. CO 2 is transported through approximately 12 miles of pipeline from Plant Barry’s capture facility and is injected into the saline aquifer sandstones of the Paluxy formation at Citronelle oil field. The following outlines the details and characteristics of each point of transportation and the quality of CO 2 being transported.

01 COAL, LIGNITE, AND PEAT↗

Southeast Carbon Sequestration Partnership (SECARB) Phase III Anthropogenic Test at Citronelle Field, Mobile Co., AL: Project Assessment Report

The Southeast Carbon Sequestration Partnership Phase III Anthropogenic Test at Citronelle Field is the United States’ largest CO 2 capture and transportation, injection, storage and monitoring project using CO 2 derived from a coal-fired power station. The project represents a U.S. Department of Energy research and development initiative designed to demonstrate deep underground injection and containment of 100,000 tonnes or more of anthropogenic-source CO 2 . This report provides an assessment of the CO 2 injection at the Citronelle Anthropogenic Test site for the period August 23, 2012 to August 31, 2013. The purpose of the project assessment is to re-evaluate the AoR for the injection well. The AoR is defined as the region surrounding the geological sequestration project that may be impacted by the injection activity. The AoR is further defined as the farthest reach of the tangible CO 2 plume and/or the region of ‘significant’ reservoir pressure increase. An updated geologic model of the injection zones and storage reservoir sandstones incorporates geologic data obtained from the injection well and characterization wells drilled at the Phase III Anthropogenic Test site. The numerical modeling of the injection was conducted using the updated geologic model, plus the monitoring results obtained to August 31, 2013. The simulation demonstrates effective containment of CO 2 by the reservoir architecture of the upper Paluxy Formation, consisting of multiple, stacked, highly porous and permeable sandstones, separated by low permeability flow barriers. The CO 2 containment demonstrated in this report requires an AoR with a radius of 440 ft from the injection well. This revision reduces the radius of the AoR from the preinjection determination of 1,700 ft. With the revised AoR, the only well within the AoR is the injection well itself, the D 9-7 #2. The nearest well to the injector is the D 9-8 #2. The surface location is 870 ft away from the D 9-7 #2, placing the D 9-8 #2 outside the revised AoR.

01 COAL, LIGNITE, AND PEAT↗

Geodyn Material Library: Pseudocap models for dry porous tocks

This report describes the second edition of the Pseudocap Strength models for porous rocks implemented in GEODYN material library. The first model was developed in 2007 and calibrated for concrete. Then, the model parameters were calibrated based on triaxial tests reported for limestones and sandstones of various porosities. In these models some key parameters were chosen as functions of the reference porosity,Φ. Since then multiple modifications were implemented in the model, therefore, it has been recalibrated for some common porous materials such as limestones, sandstones, alluvium, tuffs and granite. Two types of models are described in this repot. The first type (called Pseudocap Model or PM) is for rocks from a specific location. Parameters were calibrated for several specific geologic materials. The second type (called Generic Pseudocap Model or GPM) is useful for the sites where only basic information (rock type, porosity) is available. Generic models include built-in correlations between porosities and other mechanical properties observed for certain rock types. The models of both types were validated by comparing not only to quasi-static triaxial tests for these materials but also to shock Hugoniot data and spherical explosion data for some materials. All models were derived in the frame of isotropic plasticity. They are designed to be used in explicit finite element/difference codes. Tangent stiffness tensor is not provided but can be calculated numerically for the model to be used in implicit finite element codes. For an isotropic material the stress can be decomposed into volumetric and deviatoric parts. The volumetric part is modeled using an Equation of state (EOS) which calculates the pressure and the bulk sound speed as functions of the internal specific energy and density. Here a simple, Mie-Gruneisen EOS is presented, but tabulated EOS (LEOS) provided by the library can be used as well. The stress is limited by the yield surface which depends on three invariants of the stress tensor and specific internal energy. In addition, to capture the strain-rate dependence a simple multiplier is used for the yield surface which depends on the equivalent plastic strain rate. The failure surface (the ultimate yield, Y f , defined later) is chosen in the Hoek-Brown form, commonly used in rock mechanics. It includes measurable parameters such as Unconfined Compressive Strength (UCS) as well as scale parameters characterizing the quality of the rock such as GSI (Geologic Strength Index). Thus, even though the model is calibrated for small samples it offers a way to extrapolate the strength to the field scale using geological characterization of the rock mass. The model captures effects of brittle-ductile transition in rocks by introducing a cap multiplier to the yield function. The rate of dilatancy (bulking) is proportional to the slope of the yield surface affected by the cap. Therefore, it takes place only at low confinements when the pressure is less than the brittle-ductile transition pressure, P BD . On the contrary, the porous compaction takes place at pressures higher than P BD . The cap moves as the porosity is compacted or new porosity is generated due to dilatancy. The porous compaction is modeled using an evolution equation which includes deviatoric stress so that the onset of compaction corresponds to the cap surface. The model captures effects of shear-enhanced compaction which is an important for porous rocks. Section 2 describes the modeling framework and Section 3 presents the model calibration procedure. Section 4 compares experimental data for various rocks versus model predictions. The model parameters used for this comparison are given in Appendix. The files with material constants are available with the latest GEODYN material library distribution.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the One Earth Energy Well #1 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize the Lower Mt. Simon Sandstone and Eau Claire Formation core from the One Earth Energy Well #1 (OEE Well #1) in the Illinois Basin. The primary impetus of this work is a collaboration between the U.S. Department of Energy (DOE), the Illinois State Geological Survey (ISGS), the University of Illinois, and One Earth Energy to characterize and make publicly available core information of interest to carbon sequestration efforts in the Illinois Basin. This stratigraphic well and the core data produced in this report will aid in understanding the carbon sequestration potential of the Lower Mt. Simon Sandstone and the sealing capacity of the overlying units. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/illinois-storage-corridor-one-earth-energy-1-core.

47 OTHER INSTRUMENTATION↗

Facies Analysis and Depositional Environments of the Upper Cambrian Eau Claire Formation in Central and Northern Illinois

The Cambrian Eau Claire Formation is a confining unit for geologic carbon dioxide (CO2) storage, and potentially a confining unit for hydrogen storage, within the underlying Mount Simon Sandstone in the Central and Northern Illinois Basin. However, extensive regional studies on lateral continuity, environment of deposition, and depositional fabric of the Eau Claire Formation in the Illinois Basin are minimal compared to studies of the underlying Mount Simon Sandstone. This study presents an integrated facies analysis using sedimentological, stratigraphic, ichnological, and mineralogical data to interpret the depositional environments of the Eau Claire Formation, emphasizing the dynamic nature of sedimentary systems. By combining core analyses, thin-section analysis, facies interpretation from geophysical logs, and regional stratigraphic framework interpretation, this work provides insights into the integrated depositional framework across diverse depositional environments. These findings suggest that the Eau Claire Formation in the Central and Northern Illinois Basin was deposited in a shallow marine environment, ranging from tidal flats to offshore settings. Its mixed siliciclastic-carbonate succession was primarily controlled by relative sea-level change.

58 GEOSCIENCES↗

Petrographic and Advanced Geologic Characterization Report on Lively Grove #1 (API# 1218924947)

Lively Grove #1 (LG1 API number 1218924947) well was drilled to a depth of 5,758 feet, from the Glen Dean Limestone to the top of the Precambrian unit. In total, 49 thin sections were taken from Rotary Sidewall Core (RSWC), and one thin section was taken from Whole Core (2,918 feet, New Albany Shale) from 1,700 to 5,872 feet for this report. This report details specifically thin section point-counting analysis that includes mineralogical and pore space analysis, including grain size analysis annotated thin section photomicrographs, scanning electron microscopy (SEM) with Energy Dispersive x-ray Spectroscopy (EDS), X-ray Diffraction (XRD), statistics of grain size analysis on St. Peter Sandstone thin sections, and Argon-Argon (Ar-Ar) dating on Precambrian samples from LG1. Characterized units include the Salem Limestone, New Albany Shale, Trenton Group, Joachim Dolomite, St. Peter Sandstone, Everton Formation, Eminence Formation, Davis Member, Eau Claire Formation, and Precambrian Basement.

01 COAL, LIGNITE, AND PEAT↗

One Earth Energy Seismic Interpretation

The objectives of the Illinois Storage Corridor (ISC) project are to accelerate commercial deployment of carbon capture utilization and storage at two individual sites and receive approvals for Underground Injection Control (UIC) Class VI permits for construction at each site (ISC Project Narrative, 2020). As part of this project, and as part of the subsurface geologic characterization, 2D seismic data was acquired at both sites. This report summarizes the findings from the 2D and 3D seismic interpretation at the One Earth Energy site near Gibson City, Illinois. The seismic data confirms the stratigraphic continuity of the Mt. Simon Arkose Zone storage interval and the Eau Claire confining unit across the project area. The seismic data also indicates that there are faults that transect the Mt. Simon Arkose Zone Sandstone storage reservoir within the modeled CO 2 plume (for more detailed information, see Faults and Fractures section of One Earth Energy Class VI Permit applications). However, the seismic data also shows that there are no faults within the modeled CO 2 plume that transect the confining unit Eau Claire Formation. The faults that transect the Mt. Simon Arkose Zone Sandstone storage reservoir all tip out in the Lower Mt. Simon Formation and do not reach the overlying Eau Claire confining unit. A small 3D survey acquired around the One Earth Energy #1 characterization well confirms these findings.

20 FOSSIL-FUELED POWER PLANTS↗

One Earth Energy Static and Dynamic Reservoir Modeling

This report presents the static and dynamic reservoir modeling conducted for the CarbonSAFE Phase III Illinois Storage Corridor project to assess the feasibility of commercial-scale CO 2 storage in the Mt. Simon Sandstone at the One Earth Energy (OEE) site in McLean County, Illinois. Three-dimensional geocellular models of the Mt. Simon storage complex were developed in Petrel ® by integrating petrophysical log data, core analyses, and seismic surveys from the OEE #1 stratigraphic test well and two nearby wells, with multiple model versions created as new data became available. Dynamic reservoir simulations, performed using Landmark's Nexus software, progressed through three phases (preliminary, sensitivity, and UIC Class VI permit studies) evaluating injection scenarios across varying rates, well orientations, permeability models, and multi-well configurations. Results demonstrate that commercial-scale storage is feasible: three injection wells spaced approximately one mile apart can store a total of 90 million tonnes of CO 2 over 20 years, producing a combined plume with an equivalent radius of 3.2 miles and a maximum pressure-front-defined Area of Review of 178 mi 2 at the end of injection that diminishes to 34 mi 2 after 50 years of post-injection monitoring. Sensitivity analyses indicate that a 20% change in porosity or permeability yields approximately a 7% change in AoR radius, and that perforating the high-permeability arkosic zone minimizes the pressure front compared to injection in the upper Mt. Simon Sandstone.

09 BIOMASS FUELS↗

Prairie State Generating Company Site: Storage Field Development Plan

This Storage Field Development plan presents the Storage Complex characterization results, construction, monitoring, operational plans, and costs associated with the proposed Prairie State Energy Campus - Carbon Capture and Storage (PSEC-CCS) project in Washington County, Illinois, near Marissa. The proposed storage complex, known as the St. Peter-Everton Storage Complex, comprises the St. Peter Sandstone and Everton sandstone reservoirs, with the Maquoketa Shale serving as the primary confining unit and the Knox Group as lower confining unit. The lowermost Underground Source of Drinking Water (USDW) identified for the site is the Pennsylvanian section.

01 COAL, LIGNITE, AND PEAT↗

Geology of the One Earth Energy Site

The One Earth Energy site is one of two sites in the Illinois Storage Corridor (ISC) project. The objectives of the ISC project is to accelerate commercial deployment of carbon capture utilization and storage at two individual sites and receive approvals for Underground Injection Control (UIC) Class VI permits for construction at each site. At the One Earth Energy site, an extensive data collection program was undertaken, which included the drilling of a test well (One Earth Energy #1 [OEE #1]), four 2D seismic lines, and a small 3D seismic survey. The OEE #1 well was drilled in 2022 and acquired extensive core, log, and testing data to characterize the subsurface geology of the site. Coring was focused on the storage interval, the Mt. Simon Sandstone, and the confining interval, the Eau Claire Formation. The core and log data were used to evaluate the sedimentology and sequence stratigraphy, as well as to develop the conceptual geologic model. This report includes the geological summaries of the Mt. Simon Sandstone and the Eau Claire Formation. The extensive analysis of the log data is included in the petrophysical section, showing ranges of porosity, estimated pore size, and the mineral content of selected zones in the well. The separate petrographic technical report entitled “Petrographic and Advanced Geologic Characterization Report on One Earth Energy #1 (API# 1211325373)”, report number DOE-UIUC-0031892-04, details thin section point-counting analysis that includes mineralogical and pore space analysis, including grain size analysis, annotated thin section photomicrographs, scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS), and statistics of grain size analysis on Mt. Simon thin sections from OEE #1. The final OEE #1 well data to be included in this geology report is the routine core analysis of both whole core plugs and rotary sidewall core plugs. In addition to the OEE #1 well, four 2D seismic lines and a small 3D survey were acquired as part of the overall subsurface geological characterization. This geology report references the seismic interpretation report, entitled “One Earth Energy Site Seismic Interpretation Task 5.0”, report number DOE-UIUC-0031892-07. This report details the stratigraphic and structural interpretation of the 2D and 3D seismic data acquired at the One Earth Energy site. The 2D seismic data was acquired in 2019 and 2021, and the 3D survey was acquired in 2022. The objectives of the seismic programs were to contribute to the subsurface characterization of the Mt. Simon-Eau Claire Storage Complex by evaluating the continuity of potential storage reservoirs and containment intervals across the project area, and to determine if any geologic features are present that would increase containment risk to the proposed carbon storage project.

09 BIOMASS FUELS↗

Storage Field Development Plan: One Earth Energy

This Storage Field Development plan presents the Storage Complex characterization results, construction, monitoring, and operational plans, and costs associated with the proposed One Earth Sequestration Carbon Capture and Storage (OES-CCS) site in McLean County, Illinois, near Gibson City. The proposed storage complex, known as the Mt. Simon Storage Complex, comprises the Cambrian Mt. Simon Sandstone reservoir and the primary seal, the Cambrian Eau Claire Formation. The lowermost Underground Source of Drinking Water (USDW) identified for the site is the Ordovician St. Peter Sandstone. Geologic characterization of the Mt. Simon Storage Complex at the OES-CCS site was performed by the Illinois Storage Corridor CarbonSAFE Phase III project, which also prepared and submitted three UIC Class VI applications to construct three injection wells; the permit applications were submitted and are in the federal EPA review process. A characterization well, OEE #1, was drilled to collect site-specific data. These data were analyzed and used to develop the UIC Class VI applications. The OEE #1 well will be converted to an in-zone monitoring (IZM) well for the injection phase. The proposed buildout for the OES-CCS site includes (1) three injection wells (OES #1, OES #2, and OES #3), (2) two IZM wells, (3) two above confining zone (ACZ) monitoring wells, one of which will be used to monitor the lowermost USDW, (4) capture and compression facilities, and (5) transportation facilities, i.e., pipelines. A pre-operational testing program was proposed in the Class VI permit application and will be employed at the site pending approval. Additional pre-injection (baseline), syn-injection, and post-injection monitoring and site care procedures will be followed by OES to ensure that injection activities are protective of human health and the environment. Injection is scheduled to begin in 2025, distributed across the three injection wells in accordance with the permit operating conditions. One Earth Sequestration intends to inject up to 90 million tonnes of CO 2 over a period of approximately 20 years. Injection will begin at approximately 0.5 million tonnes of CO 2 annually and ramp up to a maximum of 4.5 million tonnes annually. Daily injection rates are expected to range from 1,400 to 1,500 tonnes per day initially and reach a maximum of approximately 4,225 tonnes per day, depending on site geology and injectivity at each injection well location, and CO 2 availability. The costs associated with the OES-CCS project include pre-operational costs (e. g. additional seismic data acquisition and well drilling), capture and transportation facility and equipment costs, predicted field operating expenditures (OpEx), and decommissioning and post-injection site care (PISC) costs. The risks associated with project activities, such as site construction, injection operations, and verification of secure storage were evaluated, and mitigation strategies proposed to alleviate those risks.

09 BIOMASS FUELS↗

Up-Scaling Geochemical Reaction Rates for Carbon Dioxide (CO2) in Deep Saline Aquifers

The overall goal of the project was to bridge the gap between our knowledge of small-scale geochemical reaction rates and reaction rates meaningful for modeling transport at core scales. The working hypothesis was that reaction rates, determined from laboratory measurements based upon reactions typically conducted in well mixed batch reactors using pulverized reactive media may be significantly changed in in situ porous media flow due to rock microstructure heterogeneity. Specifically we hypothesized that, generally, reactive mineral surfaces are not uniformly accessible to reactive fluids due to the random deposition of mineral grains and to the variation in flow rates within a pore network. Expected bulk reaction rates would therefore have to be correctly up-scaled to reflect such heterogeneity. The specific objective was to develop a computational tool that integrates existing measurement capabilities with pore-scale network models of fluid flow and reactive transport. The existing measurement capabilities to be integrated consisted of (a) pore space morphology, (b) rock mineralogy, and (c) geochemical reaction rates. The objective was accomplished by: (1) characterizing sedimentary sandstone rock morphology using X-ray computed microtomography, (2) mapping rock mineralogy using back-scattered electron microscopy (BSE), X-ray dispersive spectroscopy (EDX) and CMT, (3) characterizing pore-accessible reactive mineral surface area, and (4) creating network models to model acidic CO{sub 2} saturated brine injection into the sandstone rock samples.

58 GEOSCIENCES↗

Preliminary simulations of planned experiments to study the impact of trace gases on the capacity of the Weyburn-Midale field to store carbon dioxide

The CO{sub 2} stream injecting into the Weyburn-Midale field can be generally classified as a reducing stream with residual H{sub 2}S and low-molecular weight hydrocarbons. The composition of the CO{sub 2} gas stream from the Dakota Gasification Company is reported to be 95% CO{sub 2}, 4% hydrocarbons, and 1% H{sub 2}S by volume (Huxley 2006). In addition to the H{sub 2}S introduced at the injection wells, significant concentrations of H{sub 2}S are thought to have been produced in-situ by sulfate reducing bacteria from previous water floods for enhanced oil production. Produced gas compositions range in H{sub 2}S concentrations from 1 to 6 volume percent. The produced gas, including the trace impurities, is re-injected into the field. Although there is no evidence for inorganic reduction of SO{sub 4}{sup 2-} to H{sub 2}S at the Weyburn-Midale field, Sitchler and Kazuba (2009) suggest that SO{sub 4}{sup 2-} can be inorganically reduced to elemental sulfur in highly reducing environments based on a natural analog study of the Madison Formation in Wyoming. They propose that elevated concentrations of CO{sub 2} dissolve anhydrite to produce the sulfate that is then reduced. Oxidizing CO{sub 2} streams with residual O{sub 2} and SO{sub 2} typical of streams captured from oxyfuel and post combustion processes are not presently an issue at the Weyburn-Midale field. However it is possible that the oxidizing CO{sub 2} streams may be injected in the future in carbonate reservoirs similar to the Weyburn-Midale field. To date there are few modeling and experimental studies that have explored the impact of impurity gases in CO{sub 2} streams targeted for geologic storage (Gale 2009). Jacquemet et al (2009) reviewed select geochemical modeling studies that explored the impact of SO{sub 2} and H{sub 2}S impurities in the waste streams (Gunter et al., 2000, Knauss et al., 2005, Xu et al., 2007). These studies collectively show that SO{sub 2} significantly reduces the pH when oxidized to H{sub 2}SO{sub 4} causing enhanced dissolution of carbonate minerals and some sulfate mineral precipitation. Low pH results in higher mineral solubility and faster dissolution rates and is thought to enhance porosity and permeability near the injection well when trace amounts of SO{sub 2} is injected with CO{sub 2}. The impact of H{sub 2}S on storage reservoir performance appears to more subtle. Knauss et al (2005) report no significant impacts of injection of CO{sub 2} gas streams with and without H{sub 2}S (1 M Pascal H{sub 2}S + 8.4 M Pascal CO{sub 2}) in simulations of CO{sub 2} storage in the Frio sandstone formation. Geochemical reactions for H{sub 2}S impurities include enhance field alkalinity and reaction with iron bearing minerals that may delay breakthrough of H{sub 2}S relative to CO{sub 2}. Emberley et al. (2005) report that half of the alkalinity measured at monitoring wells at the Weyburn-Midale field is due to HS{sup -}. Schoonen and Xu (2004) report that H{sub 2}S can be sequestered as pyrite in sandstones and carbonates by dissolving iron hydroxides and iron-bearing clays. Similarly, Gunter et al (2000) propose the that siderite converts to iron sulfides when it is reacted with H{sub 2}S. The geochemical reactions between H{sub 2}S and iron bearing minerals together with the high solubility of H{sub 2}S relative to CO{sub 2} may contribute to the delayed break though of H{sub 2}S in experiments. A few core flood experiments have shown that the injection of supercritical CO{sub 2} into carbonate aquifers has the potential to significantly alter the porosity in the absence of trace gases such as SO{sub 2} and H{sub 2}S. Luquot and Gouze (2009) documented a 2% porosity increase in carbonate cores when rock-water interactions were transport limited and solution concentrations were closer to equilibrium and a 4% porosity increase when rock-water interactions were reaction limited and solution compositions were further from equilibrium. Similarly Le Guen et al (2007) used x-ray micro-tomography and geochemistry to show that porosity significantly increases when reacted with pure CO{sub 2}. While both of these studies nicely illustrate the relationship between reaction kinetics, thermodynamics, and porosity changes using x-ray micro-tomography, actual changes in a reservoir may be significantly lower because the input brines used in these studies were significantly dilute and below mineral carbonate saturation. The objective of the simulations reported was to explore viable experimental parameters for CO{sub 2} core flood experiments designed to investigate the impact of CO{sub 2} on porosity and permeability in the Weyburn-Midale storage reservoir. We describe the simulation results for core flood experiments in which formation waters that are equilibrated with supercritical CO{sub 2} at 60 C and 14.7 M Pascals react with three different flow units within the Midale formation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mudstone Baffles and Barriers in Lower Cretaceous Strata at a Proposed CO 2 Storage Hub in Kemper County, Mississippi, United States

The Cretaceous and Tertiary deposits in Mississippi, Alabama, and the adjacent continental shelf constitute a widespread succession of sandstone, mudstone, and carbonate that has proven to be an important target for geologic CO 2 storage in the onshore Gulf of Mexico basin. Integrated analysis of stratigraphy, sedimentology, and reservoir properties based on cores and geophysical well logs indicates that the Paluxy Formation and Washita- Fredericksburg interval present gigatonne-class storage opportunities. The distribution, geometry, and composition of the area is a direct reflection of the original depositional environments, and understanding these factors is essential for understanding the geologic storage potential of the Paluxy Formation and Washita-Fredericksburg interval at the Kemper County energy facility in Mississippi. Geologic characterization of the Mississippi Embayment at the energy facility focused primarily on characterizing the confinement potential of the storage complex. Integration of core analyses and geophysical well logs has yielded a high-resolution stratigraphic analysis of storage reservoirs, baffles, barriers, and seals. Scanning electron microscopy (SEM) coupled with energy dispersive X-ray spectroscopy (EDS), and quantitative X-ray diffraction (XRD) was used to characterize microfabric, pore types, and mineralogy within mudstone of the east-central Mississippi Embayment at the Kemper County energy facility. Mudstone beds in the Paluxy Formation and Washita-Fredericksburg interval have variable thickness and continuity. High water saturation in the Cretaceous mudstone units influences swelling smectite clay and mudrock permeability based on pulse decay analysis is 1–96 nD. These low permeability values indicate that the mudstone units are effective baffles, barriers, and confining intervals that make significant migration of injected CO 2 out of the storage complex unlikely. The numerous baffles and barriers within the target reservoir intervals, moreover, favor the retention of multiple CO 2 in plumes within the abundant stacked sandstone bodies.

03 NATURAL GAS↗

Carbon Storage and Enhanced Oil Recovery in Pennsylvanian Morrow Formation Clastic Reservoirs: Controls on Oil–Brine and Oil–CO2 Relative Permeability from Diagenetic Heterogeneity and Evolving Wettability

The efficiency of carbon utilization and storage within the Pennsylvanian Morrow B sandstone, Farnsworth Unit, Texas, is dependent on three-phase oil, brine, and CO2 flow behavior, as well as spatial distributions of reservoir properties and wettability. We show that end member two-phase flow properties, with binary pairs of oil–brine and oil–CO2, are directly dependent on heterogeneity derived from diagenetic processes, and evolve progressively with exposure to CO2 and changing wettability. Morrow B sandstone lithofacies exhibit a range of diagenetic processes, which produce variations in pore types and structures, quantified at the core plug scale using X-ray micro computed tomography imaging and optical petrography. Permeability and porosity relationships in the reservoir permit the classification of sedimentologic and diagenetic heterogeneity into five distinct hydraulic flow units, with characteristic pore types including: macroporosity with little to no clay filling intergranular pores; microporous authigenic clay-dominated regions in which intergranular porosity is filled with clay; and carbonate–cement dominated regions with little intergranular porosity. Steady-state oil–brine and oil–CO2 co-injection experiments using reservoir-extracted oil and brine show that differences in relative permeability persist between flow unit core plugs with near-constant porosity, attributable to contrasts in and the spatial arrangement of diagenetic pore types. Core plugs “aged” by exposure to reservoir oil over time exhibit wettability closer to suspected in situ reservoir conditions, compared to “cleaned” core plugs. Together with contact angle measurements, these results suggest that reservoir wettability is transient and modified quickly by oil recovery and carbon storage operations. Reservoir simulation results for enhanced oil recovery, using a five-spot pattern and water-alternating-with-gas injection history at Farnsworth, compare models for cumulative oil and water production using both a single relative permeability determined from history matching, and flow unit-dependent relative permeability determined from experiments herein. Both match cumulative oil production of the field to a satisfactory degree but underestimate historical cumulative water production. Differences in modeled versus observed water production are interpreted in terms of evolving wettability, which we argue is due to the increasing presence of fast paths (flow pathways with connected higher permeability) as the reservoir becomes increasingly water-wet. The control of such fast-paths is thus critical for efficient carbon storage and sweep efficiency for CO2-enhanced oil recovery in heterogeneous reservoirs.

Rasmussen, Lindsey↗

Deposition, Diagenesis, and Sequence Stratigraphy of the Pennsylvanian Morrowan and Atokan Intervals at Farnsworth Unit

Farnsworth Field Unit (FWU), a mature oilfield currently undergoing CO2-enhanced oil recovery (EOR) in the northeastern Texas panhandle, is the study area for an extensive project undertaken by the Southwest Regional Partnership on Carbon Sequestration (SWP). SWP is characterizing the field and monitoring and modeling injection and fluid flow processes with the intent of verifying storage of CO2 in a timeframe of 100–1000 years. Collection of a large set of data including logs, core, and 3D geophysical data has allowed us to build a detailed reservoir model that is well-grounded in observations from the field. This paper presents a geological description of the rocks comprising the reservoir that is a target for both oil production and CO2 storage, as well as the overlying units that make up the primary and secondary seals. Core descriptions and petrographic analyses were used to determine depositional setting, general lithofacies, and a diagenetic sequence for reservoir and caprock at FWU. The reservoir is in the Pennsylvanian-aged Morrow B sandstone, an incised valley fluvial deposit that is encased within marine shales. The Morrow B exhibits several lithofacies with distinct appearance as well as petrophysical characteristics. The lithofacies are typical of incised valley fluvial sequences and vary from a relatively coarse conglomerate base to an upper fine sandstone that grades into the overlying marine-dominated shales and mudstone/limestone cyclical sequences of the Thirteen Finger limestone. Observations ranging from field scale (seismic surveys, well logs) to microscopic (mercury porosimetry, petrographic microscopy, microprobe and isotope data) provide a rich set of data on which we have built our geological and reservoir models.

04 OIL SHALES AND TAR SANDS↗

Implementing Large-Scale CCS in Complex Geologic Reservoirs: Insights from Three Appalachian Basin Case Studies

This paper presents three design case studies for implementing large-scale geologic carbon storage in the Appalachian Basin region of the midwestern United States. While the Appalachian Basin has a challenging setting for carbon storage, the three case studies detailed in this article demonstrate that there are realistic options for implementing carbon storage in the basin. Carbonate rock formations, depleted hydrocarbon reservoirs, and moderate-porosity sandstones can be utilized as carbon-storage reservoirs in the Appalachian Basin. While these are not typical concepts for CO2 storage, the storage zones have advantages such as defined trapping mechanisms, multiple caprocks, and defined boundaries that are not always present in thick, permeable sandstones being targeted for many carbon-storage projects. The geologic setting, geotechnical parameters, and hydrologic setting for the three case studies are provided, along with the results of reservoir simulations of the CO2 injection-deployment strategies. The geological rock formations available for CO2 storage in the Appalachian Basin are more localized reservoirs with defined boundaries and finite storage capacities. Simulation results showed that accessing carbon-storage resources in these fields may require wellfields with 2–10 injection wells. However, these fields would have the capacity to inject 1–3 million metric tons of CO2 per year and up to 90 million metric tons of CO2 in total. The CO2 storage resources would fulfill decarbonization goals for many of the natural-gas power plants, cement plants, hydrogen plants, and refineries in the Appalachian Basin region.

Sminchak, Joel↗