Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Preparation Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Ambient and High Pressure CuNiSb 2 : Metal-Ordered and Metal-Disordered NiAs-Type Derivative Pnictides

The mineral Zlatogorite, CuNiSb 2 , was synthesized in the laboratory for the first time by annealing elements at ambient pressure (CuNiSb 2 -AP). Rietveld refinement of synchrotron powder X-ray diffraction data indicates that CuNiSb 2 -AP crystallizes in the NiAs-derived structure ( P 3 m 1, #164) with Cu and Ni ordering. The structure consists of alternate NiSb 6 and CuSb 6 octahedral layers via face-sharing. The formation of such structure instead of metal disordered NiAs-type structure ( P 6 3 / mm c, #194) is validated by the lower energy of the ordered phase by first-principle calculations. Interatomic crystal orbital Hamilton population, electron localization function, and charge density analysis reveal strong Ni-Sb, Cu-Sb, and Cu-Ni bonding and long weak Sb-Sb interactions in CuNiSb 2 -AP. The magnetic measurement indicates that CuNiSb 2 -AP is Pauli paramagnetic. First-principle calculations and experimental electrical resistivity measurements reveal that CuNiSb 2 -AP is a metal. The low Seebeck coefficient and large thermal conductivity suggest that CuNiSb 2 is not a potential thermoelectric material. Single crystals were grown by chemical vapor transport. The high pressure sample (CuNiSb 2 -8 GPa) was prepared by pressing CuNiSb 2 -AP at 700 °C and 8 GPa. However, the structures of single crystal and CuNiSb 2 -8 GPa are best fit with a disordered metal structure in the P 3 m 1 space group, corroborated by transmission electron microscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Speciation mapping of the oxidation layer on aged uranium dioxide using scanning transmission x-ray spectromicroscopy

In this study, UO 2 was aged in humid air and prepared as a thin section using a focused ion beam (FIB) instrument. The specimen was measured using synchrotron radiation spectromicroscopy techniques at the Beamline 11.0.2 STXM end station of the Advanced Light Source (ALS). Non-negative matrix factorization (NMF) methods were used to identify and map three component x-ray absorption near-edge structure (XANES) spectra in the oxygen K-edge data, revealing a surface layer of U 4 O 9 with a thickness of 206 ± 21 nm, and the bulk of the sample remaining as UO 2 . Uranium N 4,5 -edge XANES spectromicroscopy supports these results. The diffusion-controlled parabolic rate constant for UO 2 oxidation to U 4 O 9 was calculated from the observed layer thickness and compared to literature values. Complementary transmission electron microscopy (TEM) was used to image the sample and identify the phases present in various regions, confirming the STXM results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Apollo Next Generation Sample Analysis (ANGSA): A Segue to the Next Era of Lunar Exploration and Sample Return Activities

In the fifty years since the first lunar samples were collected on Apollo 11, significant advancements have taken place in laboratory analysis, planetary science, and astromaterials curation. These advances are now being leveraged for the Apollo Next Generation Sample Analysis (ANGSA) Program, which aims to study specially curated Apollo samples that have never been studied before. Since Apollo 17 in 1972, a great deal has been learned about the Moon, including the unique environments of the poles. Building upon Apollo and remote sensing studies since then, the Artemis Program aims to explore the cold environments near the lunar south pole while achieving the concurrent goals of landing the first woman and the next man on the Moon by 2024. Recent developments for ANGSA have significantly accelerated our readiness for Artemis sample return, particularly in the area of cold sample studies. Four science teams were selected to study cold and/or volatile-bearing samples collected during the Apollo program. These samples have special storage and handling requirements that necessitate their processing in a -20°C environment that meets the Apollo materials and cleanliness requirements. NASA has recently undertaken the development and implementation of a cold sample processing facility to support ANGSA. A similar facility will be needed to process the cold, volatile-bearing samples planned to be returned by Artemis missions; therefore, ANGSA provides excellent preparation for Artemis’ future cold sample processing efforts. We will outline the goals of the ANGSA and Artemis programs, illustrating the complementary nature of the work for both. We will describe the efforts to date in designing, testing, and implementing a cold curation facility that meets the requirements of ANGSA and Apollo curation. We will then outline future work for that facility to reach operational readiness. Finally, we will present the sample collection and curation strategies for Artemis, showing how they overlap and build on ANGSA efforts. The development of cold curation at NASA represents a significant leap in the knowledge, experience, and technologies used in astromaterials curation, opening the door for new investigations of lunar volatiles, impacts, formation processes, prebiotic chemistry, and resource utilization, among many others.

Julie Mitchell↗

Quarterly Research Performance Progress Report (Q8)

As part of Task 1, we have started by testing our modeling capabilities by reproducing isothermal DFIT simulations presented in the literature. Once satisfied with the results we have started by targeting the modeling of the DFITs at conducted at well 58-32. We have a identified a specific test (cycle 4 in zone 2) as the most interesting to be model with GEOS hydraulic fracturing module. Thus, we have first produced results with an isothermal model and adjusted model parameters to get a satisfying match with field pressure data. The, we have added thermal effects and compared the modeling results with and without thermal effects to estimate how thermal effects may influence test interpretation. Models seem to suggest that, for small volumes of fluid, thermal effects are moderate. In Task 2, we have adapted GEOS phase-field formulation to be able to simulate near-wellbore hydraulic fracture nucleation and propagation. We have devised a novel formulation that, compared to other existing ones, incorporates rock strengths. We have submitted a journal publication about our work. We are currently employing this phase-field formulation to model the experiments taking place at U Pitt and help us understand the effect of various parameters. In Task 3, we have built a model of the region surround well 16A and have started modeling stage 3 stimulation because of its simpler planar geometry. After calibrating simulation parameters using known analytical solutions, we have simulated the stage 3 stimulation using our isothermal hydraulic fracturing module, varying the permeability field, the stress conditions including different physics to get a better understanding of the numerical challenges and of the effects of varying these parameters on the simulation results. In Task 4 laboratory experimentation, a set of specialized drilling and injection tools has been customized and constructed to accommodate an inclined well with an orientation of up to 30 degrees relative to material anisotropy or principal stress axes. These inclined samples have also undergone thermal stress and hydraulic fracturing at a temperature of 190 degrees Celsius. Furthermore, both vertical and deviated sampling testing setups enable an extended analysis of post-peak pressure behaviors, facilitating post-test pressure analyses such as the G-function, step rate, and fracture reopening measurements. Thus, the key components of in-situ stress estimation can be extracted and validated through our experiment, providing a solid foundation for validating existing in-situ stress estimation theories or proposing new ones. Simultaneously, we are integrating computer vision techniques with traditional experimental fracture observation methods such as multi-overcore/slicing and water-penetration fracture observation. This combination will prove beneficial in populating the hydraulic fracture patterns database, generated under challenging EGS conditions. This approach aims to deepen our understanding of the complexities in EGS reservoirs and pave the way for future data-driven investigations. Additionally, PITT has also equipped the ELE International compression machine, which is now prepared for conducting indirect tensile and fracture toughness tests. These tests will aid in characterizing how rock fabrics influence the resulting fracture patterns. Additionally, we have completed the required personnel training and gained access to Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) for conducting more detailed characterization and analysis of rock fabrics, as well as the examination of thermal and hydraulically induced fracture patterns. Thus, the PITT team has effectively demonstrated the capabilities of our experimental apparatuses in exploring the thermal effects, well deviation angles, material anisotropy, and operational choices (such as circulation rate, injection fluid viscosity, and injection rate) and their impact on pressure responses and fracture trajectories under the Utah FORGE conditions.

15 GEOTHERMAL ENERGY↗

In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.

Sarrazin, P.↗

Vapor Growth of ZnSe-based Compound Semiconductors in Low Gravity environment on International Space Station

Six low-gravity experiments of crystal growth of ZnSe-based compound semiconductors by physical vapor transport (PVT) are scheduled to be processed inside Low Gradient Furnace (LGF) on Materials Science Research Rack (MSRR) in Material Science Laboratory (MSL) on International Space Station (ISS) starting from February 27th, 2023. The flight samples consist of three unseeded growths of ZnSe, Cr-doped ZnSe and ZnSeTe as well as growth of ZnSe on top of three single crystal ZnSe seeds with orientation of (100), (110) and (111). The main scientific objective of the flight experiments is to establish the effects of gravity-driven fluid flows on Earth to (i) the non-uniform incorporation of impurities and defects and (ii) the deviation from stoichiometry observed in the grown crystals caused by growth interface fluctuations and evolution as the results of buoyancy-driven convection and irregular fluid-flows. The investigation will also evaluate the effects of gravity on the PVT process by examining (i) the growth kinetics on various seed orientations, (ii) the dopant segregation and distribution in the Cr doped ZnSe, and (iii) the compositional segregation and distribution in the ternary ZnSeTe crystal grown by PVT. Additionally, from X-ray diffraction/topography and by measuring the density and distribution of various crystalline defects it will assess the self-induced strain effects developed during processing at elevated temperatures caused by the weight of the crystals. During the ground-based preparations, the following tasks have been accomplished: • Establish the thermodynamic properties of the ZnSe binary and related ternary systems by measuring the partial pressures of the vapor phase coexisting with the condensed phases and perform phase diagram calculations for comparison. • Evaluate the effects of gravity-driven convection in the growth process by performing experiments under various vapor transport orientations relative to gravity vector, i.e., horizontal, vertically stabilized and destabilized configurations. • Establish a quantitative correlation between growth parameters and the characteristics and properties of the grown crystals by characterizing the crystals using a variety of techniques. • Evaluate the fundamentals of the current theories on vapor transport and crystal growth kinetics by performing in-situ and real-time monitoring techniques during growth. • Develop a one-dimensional diffusion limited theory of mass transport and two- and three-dimensional numerical simulations of both mass transport and heat transfer and thus establish the microgravity requirements for the flight experiments and to predict the characteristics of the grown crystals such as the solid-vapor interface shapes… etc. and establish a fundamental understanding of the crystal growth process from the comparison with experimental results.

ZnSe↗

The Acquisition, Containment, and Curation of Mars Samples on Earth

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (henceforth AACO) is responsible for receiving and curating all of NASA’s extraterrestrial samples, current and future (as per NASA Policy Directive (NPD) 7100.10E “Curation of Extraterrestrial Materials”). As such, the AACO coordinates sample capture, containment, and transportation to the curation facility as well as documents, preserves, prepares, and distributes all of the samples within NASA’s astromaterial collections for research, education, and public outreach. Since the lunar rock and soil samples returned during the Apollo Program, NASA’s first Class V Restricted Earth Return Missions, the AACO curates six other astromaterials collections. Lessons learned from each collection and respective missions (e.g. Apollo, Genesis, Stardust) as well as advancements in science and technology have informed the AACO’s plan for acquiring and curating Martian samples. Given the nature of the collection, a mobile and modular facility is recommended. The two broad requirements a Mars sample facility must maintain are: 1) the ability to contain the samples to protect the public from exposure of an “unknown unknown” biological agent and 2) ensure the scientific integrity of the samples are maintained (while maximizing scientific outcome). Although Apollo samples were eventually deemed safe and released to the scientific community for evaluation, there is no guarantee that this will be the case for Martian samples. Therefore, the facility in which the samples will be contained and investigated must be modular and able to accommodate an array of instrumentation that could be highly variable depending on the initial scientific outcomes. Furthermore, in order to facilitate proper sample capture and containment upon landing as well as sample distribution to other laboratories with proper containment, a mobile facility is a valuable investment.

Harrington, Andrea D.↗

Innovative Nuclear Materials Outboard-A Project Specimen Preparation Guide

The Innovative Nuclear Materials (INM) Program was recently established by the U.S. Department of Energy (DOE) to develop advanced material technologies for use in nuclear reactors. The INM program is presently focused on researching in-core non-fueled materials for application in fast spectrum nuclear reactors. The widespread deployment of fast reactors continues to be a prominent aspiration for advanced nuclear technology developers. However, companies working to license these reactors have no choice but to rely on historic material technologies since further optimization and advancement of these materials is impeded by the lack of fast neutron irradiation test facilities. INM-OA is a non-fueled drop-in experiment which will irradiate material specimens of interest to fast reactor applications. This experiment will be irradiated at Idaho National Laboratory (INL) in the Advanced Test Reactor (ATR) outboard-A (OA) position during normal and high temperature steady state (HTSS) cycles. It will include material specimens supplied by members of the INM program and will utilize a cadmium-lined basket to filter out incident thermal neutrons, thus simulating a faster neutron energy spectrum. Material specimens will undergo post-irradiation examination including microscopy and mechanical testing. In addition to absorption reactions, fast neutrons cause microstructural damage in materials by atom displacement, which can cause exacerbated changes in physical properties and behavior. Thus, the data obtained from the INM-OA experiment will be crucial for understanding the engineering-scale behavior of reactor materials. This document is intended for the Principal Investigators providing samples for this project. Topics included are a general description of the experiment, the irradiation experiment/capsule design, sample geometries, number of samples to be provided, documentation to be provided, a brief list potentially useful characterization methods that can be leveraged at INL, and other miscellaneous requirements specific to this project. This document is intended for informational use only.

innovative nuclear materials↗

The microbiologist's guide to metaproteomics

Metaproteomics is an emerging approach for studying microbiomes, offering the ability to characterize proteins that underpin microbial functionality within diverse ecosystems. As the primary catalytic and structural components of microbiomes, proteins provide unique insights into the active processes and ecological roles of microbial communities. By integrating metaproteomics with other omics disciplines, researchers can gain a comprehensive understanding of microbial ecology, interactions, and functional dynamics. This review, developed by the Metaproteomics Initiative (www.metaproteomics.org), serves as a practical guide for both microbiome and proteomics researchers, presenting key principles, state-of-the-art methodologies, and analytical workflows essential to metaproteomics. Topics covered include experimental design, sample preparation, mass spectrometry techniques, data analysis strategies, and statistical approaches.

bioinformatics↗

KENO-VI Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS6) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analysis. The well-known KENO-VI three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO-VI primer is designed to help a new user understand and use the SCALE/KENO-VI Monte Carlo code for nuclear criticality safety analysis. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO-VI in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO-VI that are useful in criticality analysis. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface. Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO-VI input and allows the user to quickly run a simple criticality problem with SCALE/KENO-VI. Each following section begins with a list of basic objectives identifying the goal of the section and the individual SCALE/KENO-VI features covered in detail in the section’s sample problems. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO-VI. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO-VI. Complete descriptions are provided in the SCALE/KENO-VI manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO-VI training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO-VI for criticality analysis; the SCALE/KENO-VI manual provides information on the use of SCALE/KENO-VI and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata, and sample inputs are also available at https://code.ornl.gov/scale/primers/kenovi/.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of an Ultrasonic/Sonic Driller/Corer to Obtain Sample Powder for CHEMIN, a Combined XRD/XRF Instrument

A miniature CHEMIN XRD/XRF (X-Ray Diffraction/X-Ray Fluourescence) instrument is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed in order to enable XRD analysis on an extraterrestrial body is how best to obtain a representative sample powder for analysis. For XRD powder diffraction analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a 2-dimensional detector as used in the CHEMIN instrument will produce good results with poorly prepared powders, the quality of the data will improve if the sample is fine-grained and randomly oriented. An Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL is an effective mechanism of sampling rock to produce cores and powdered cuttings. It requires low axial load (< 5N) and thus offers significant advantages for operation from lightweight platforms and in low gravity environments. The USDC is lightweight (<0.5kg), and can be driven at low power (<5W) using duty cycling. It consists of an actuator with a piezoelectric stack, ultrasonic horn, free-mass, and drill bit. The stack is driven with a 20 kHz AC voltage at resonance. The strain generated by the piezoelectric is amplified by the horn by a factor of up to 10 times the displacement amplitude. The tip impacts the free-mass and drives it into the drill bit in a hammering action. The free-mass rebounds to interact with the horn tip leading to a cyclic rebound at frequencies in the range of 60-1000 Hz. It does not require lubricants, drilling fluid or bit sharpening and it has the potential to operate at high and low temperatures using a suitable choice of piezoelectric material. To assess whether the powder from an ultrasonic drill would be adequate for analyses by an XRD/XRF spectrometer such as CHEMIN, powders obtained from the JPL ultrasonic drill were analyzed and the results were compared to carefully prepared powders obtained using a laboratory bench scale Retsch mill.

Chipera, S. J.↗

A Science-Focused Artificial Intelligence (AI) Responding in Real-Time to New Information: Capability Demonstration for Ocean World Missions

Introduction: Artificial intelligence (AI) has long been considered a potential mechanism to explore increasingly challenging environments, including those with extreme temperatures and pressures, limited communication capabilities, or those with demanding terrain. We posit that missions in extreme environments could deploy an onboard AI focused on science observations and goals in order to augment a traditional concept(s) of operations (ConOps). An onboard AI capability could perform functions such as data analysis in order to make high-level decisions, including prioritized data transmission for analysis by ground-based teams or autonomously-guided follow-on analyses that maximize science return. Such a capability would empower missions to respond to scientific data of interest in real-time; a mission could make observations and perform a preliminary analysis to alert ground-based scientists to an observation of interest, enabling an informed, rapid response from Earth-based teams. Enceladus Case Study for Onboard AI: We are developing an onboard AI capability for real-time telemetry response that formulates and carries-out informed decisions in service to established mission goals, enabling increased science return of a mission. We focus our AI development for use on a constellation of SmallSats orbiting Enceladus. Our Enceladus case study tests autonomous decision-making capabilities in scenarios with complex orbital dynamics, plume ejecta, extreme cold environments, power restrictions, and a requirement to maximize science return for a potential positive detection of life, while critically evaluating the potential for false positives. Telemetry includes simulated scientific data, spacecraft onboard operational data (e.g., position, velocity, and rotation), and engineering hardware performance data. Enceladus SmallSat Constellation. Our constellation includes eight SmallSat spacecraft in an 8:35 resonant orbit-based formation, leveraging Saturn’s gravitational forces to maintain stable orbits with global coverage around Enceladus. To our knowledge, we simulate the first stable configuration of multiple spacecraft in closed orbits around Enceladus, using a full ephemeris force model (Russell and Lara, 2009). Each spacecraft’s orbit will precess, causing an eastward ground track shift (from an orbiter’s perspective) of each spacecraft for each orbit. However, all spacecraft return to their original positions relative to Enceladus after eight Enceladus revolutions around Saturn. We model communication pathways between SmallSats to understand how information would need to be transmitted across the constellation to enable AI-driven decision-making and resource allocation across the fleet. Capability Demonstration. Our simulated capability demonstration inputs position, velocity, and rotation telemetry from our Enceladus-focused constellation simulations, and mass spectrometry data collected from abiotic and biotic laboratory-analog ocean world experiments (Theiling et al., 2018; Theiling, 2021; Da Poian et al., 2023). Data from these experiments are used to simulate MS measurements and different scenarios of science observations for onboard analysis performed on each of the eight spacecraft. For these demonstrations, we integrate 24 machine learning (ML) algorithms into an onboard intelligence as a ‘knowledge base’, including algorithms evaluating data quality and those predicting (with % confidence) gas composition, ocean aqueous chemistry, and whether the sample was influenced by microbial life. The onboard AI capability is designed to use the knowledge base to come to a consensus-based decision in the interpretation of the observed data in order to request additional action outside of a pre-defined ConOps. Requested actions could include e.g., prioritized downlink to Earth (for analysis by ground-based teams) or follow-on analyses performed across the constellation. The spacecraft’s intelligent onboard planner must then determine whether sufficient resources (e.g., time, power, etc.) are available and weigh the request with mission priorities. In our simulation, the constellation is able to identify potential biosignatures using onboard ML algorithms, evaluate the confidence of that prediction, and perform follow-on analyses across the fleet to confirm the detection, in order to best prepare a transmission of these data to Earth-based teams.

astrobiology↗

Magnetism in EuAlSi and the Eu 1−𝑥 ⁢Sr 𝑥 ⁢ AlSi solid solution solid solution

The magnetic properties of EuAlSi, a compound comprising a honeycomb lattice of Al/Si atoms and a triangular lattice of Eu atoms, are presented. By means of single-crystal x-ray diffraction, we find that EuAlSi crystallizes in an AlB 2 -type structure with space group 𝑃⁢6/mmm and unit cell parameters 𝑎 = 4.2229⁢ (10) ⁢Å and 𝑐 = 4.5268 ⁢(12)⁢ Å. Our magnetic measurements indicate that EuAlSi is a soft ferromagnetic material with 𝑇 Curie = 25.8 K. The susceptibility follows the Curie-Weiss law at high temperatures, which allowed us to determine the paramagnetic Curie temperature 𝜃 𝑃 = 36.2 ⁢(1) ⁢K and an effective magnetic moment 𝜇 eff = 8.07 ⁢(1)⁢ µ 𝐵 /Eu. This value is in agreement with the theoretical value of 7.9 µ 𝐵 for Eu 2+ free ion. Moreover, we have prepared the Eu 1−𝑥 ⁢Sr 𝑥 ⁢ AlSi solid solution, where the atoms in the triangular lattice were systematically exchanged, in order to study the evolution of the collective quantum properties from the ferromagnetic EuAlSi toward the superconducting SrAlSi. Across the Eu 1−𝑥 ⁢Sr 𝑥 AlSi solid solution, the unit cell parameters change linearly, following Vegard’s law, and making the system reliable for studying composition dependence of the interplay between the crystal structure and physical properties. As the Sr content increases, i.e., 𝑥 increases, we note a consistent reduction of 𝜇 eff and 𝑇 Curie . Long-range magnetic order in Eu 1−𝑥 ⁢Sr 𝑥 ⁢ AlSi persists up to 𝑥 = 0.95, whereas superconductivity is only observed for samples with 𝑥 > 0.97.

Walicka, Dorota I. [University of Geneva (Switzerl↗

A Draft Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth

In preparation for missions to Mars that will involve the return of samples, it is necessary to prepare for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but a specific protocol for handling and testing of returned -=1 samples from Mars remained to be developed. To refine the requirements for Mars sample hazard testing and to develop criteria for the subsequent release of sample materials from precautionary containment, NASA Planetary Protection Officer, working in collaboration with CNES, convened a series of workshops to produce a Protocol by which returned martian sample materials could be assessed for biological hazards and examined for evidence of life (extant or extinct), while safeguarding the samples from possible terrestrial contamination. The Draft Protocol was then reviewed by an Oversight and Review Committee formed specifically for that purpose and composed of senior scientists. In order to preserve the scientific value of returned martian samples under safe conditions, while avoiding false indications of life within the samples, the Sample Receiving Facility (SRF) is required to allow handling and processing of the Mars samples to prevent their terrestrial contamination while maintaining strict biological containment. It is anticipated that samples will be able to be shipped among appropriate containment facilities wherever necessary, under procedures developed in cooperation with international appropriate institutions. The SRF will need to provide different types of laboratory environments for carrying out, beyond sample description and curation, the various aspects of the protocol: Physical/Chemical analysis, Life Detection testing, and Biohazard testing. The main principle of these tests will be described and the criteria for release will be discussed, as well as the requirements for the SRF and its personnel.

Viso, M.↗

Surface preparation method for investigating the three-dimensional electronic structure of perovskite nickelates

The investigation of the electronic structures on perovskite oxides using surface-sensitive spectroscopy techniques is often hindered by their “uncleavable” nature, typically requiring expensive and complex in situ experimental setups that integrate the capabilities of sample synthesis and spectroscopy measurement under ultrahigh vacuum condition. Here, we address this challenge by developing an ozone-annealing process that yields atomically flat surfaces on perovskite oxide thin films, making them suitable for high-resolution angle-resolved photoemission spectroscopy measurements. Using this method, we present a three-dimensional electronic structure study of Nd 1−𝑥 ⁢Sr 𝑥 ⁢NiO 3 (𝑥=0 and 0.175) thin films with unprecedented accuracy. The experimentally determined low-energy fermiology exhibits quantitative agreements with two-band tight-binding simulations, which is further validated by first-principles calculations considering the material's actual crystal structure. This work provides an accessible approach for ex situ ARPES measurements on perovskite oxides and other strongly correlated oxides, including the recently discovered high-𝑇 c nickelates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improving the Near-Earth Micrometeoroid and Orbital Debris Environment Definition with LADC

The Large Area Debris Collector (LADC) is a 10 m(sup 2) aerogel and acoustic sensor system designed to characterize and collect submillimeter micrometeoroids and orbital debris on the International Space Station (ISS). The project is led by the U.S. Naval Research Laboratory (NRL) with major collaboration by the NASA Orbital Debris Program Office at Johnson Space Center. The U.S. Department of Defense Space Test Program (STP) is responsible for the integration, deployment, and retrieval of the system. The deployment is scheduled for August 2007 with an orbital collection period of one to two years. The combined area time product of LADC will provide a much needed orbital debris population update in the size regime that is important to the safety community - 100 mm and larger. Another key element for LADC is the source identification of the collected samples. Impact features such as track length and track volume can be used to estimate the impact speed and direction of any selected residual embedded in aerogel. Acoustic sensors can provide impact timing and impact location information. The combined dynamical signatures make it possible to reconstruct the orbits of some of the collected samples and lead to their source identification. Compositional analysis on the residuals can also separate debris from meteoroids and provide additional population breakdown for orbital debris (e.g., Al, paint, steel, Al2O3). To maximize the science return and minimize potential contamination from other ISS modules, a careful selection of the location and orientation of LADC on the ISS is needed. Key issues and engineering constraints encountered during mission preparation, and the expected science return based on the mission configuration, are summarized in this paper.

Liou, J.-C.↗

Martian Dust Simulator

The Martian Dust Simulator (MDS) was designed to investigate the contamination effects of Martian soil and rock on the performance and function of flight-like microvalves and flight-like filters located within the Sample Analysis at Mars (SAM) instrument suite. The SAM instrument suite, which houses over fifty percent of the science payload, is located on-board the Mars exploration rover. The mission objective of the Mars Science Laboratory Rover is to determine the past, present, and future habitability of Mars. It will serve as a robot geologist, traveling the Mars surface for a period of one Martian year (equivalent to two earth years). The microvalves were designed as a conduit to control the flow of Martian gas to the science instruments. If exposed to particle sizes greater than half a micron, both the science instruments and science equipment, including forty-seven microvalves, could experience performance degradation. As a result, filters were used at various gas inlets to protect flight hardware from particulate degradation. Additionally, the filters serve as the only interface between the Martian environment and the mechanisms within SAM. The MDS operates at 7 Torr (0.135 psi) with a gas flow rate of 0 to 20 m/s. Iron (III) Oxide was the only dust particle specimen used, although several others were initially considered (i.e. JSC-Mars-1, Corundum Powder (Al2O3), Hydrated Sulfate, and Belville (Basalt)). The overarching goal of the MDS is to demonstrate that the Mars exploration program is adequately designed and prepared for the Martian mission environment.

Zuray, Monica↗

Review: Recent advances of ToF-SIMS for environmental analysis and imaging

Background: Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis technique, initially developed and applied in inorganic materials and semiconductors. In past decades, ToF-SIMS has attracted more attention in its analysis capabilities of organic materials, with increased applications in biology, medical, and health development. It has also become a versatile and effective tool in environmental analysis due to its high mass resolution, mass accuracy, and depth profiling. Results: In this review, we first give an overview of the principle of ToF-SIMS and follow with recent ToF-SIMS applications in exemplary environmental study cases, including atmospheric aerosol, soil, water, plant, and organic solvent analysis. Moreover, sample preparation techniques are summarized in relation to corresponding environmental applications. Specifically, we call attention to ToF-SIMS investigations showcasing studies in surface chemical compositions, images, and depth profile analysis. These findings emphasize the important role of interfacial chemistry in environmental processes and provide valuable insights into dynamic processes, such as chemical transformation, particle formation, plant biology, and microbial inspired biotechnology development. The mass spectral imaging results acquired by ToF-SIMS offer a deeper understanding of intermediate stages and transient phases for environmental specimens. Significance: In situ and operando imaging offer new possibilities in studying phenomena in real time with high spatial resolution. Furthermore, it is anticipated that more research groups will use ToF-SIMS in environmental research given recent advances in measurement capabilities and surging needs in chemical mapping of complex analytes and systems.

Aerosol↗