Object Stores for CMS data [Poster]
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The overall objective of the proposed study was to advance the technical understanding of CO 2 incorporation into novel cementitious materials for the development of high value products that provide a net reduction in carbon emissions. This project combined two primary phases of research that addressed technical barriers related to (i) optimizing CO 2 storage capability of cementitious materials, (ii) evaluating and enhancing physical properties of novel carbonated materials, and (iii) assessing the reductions in life cycle CO 2 emissions attributed to CO 2 carbonation of precast cementitious materials. Engineered cementitious composites (ECC) are a class of highly ductile concrete composites that have been shown to be very durable when used in the built environment. CO 2 carbonation of ECC was examined in this study and it was found that precast ECC specimens could sequester up to 35% CO 2 by cement mass after 24 hours of curing at a CO 2 pressure of 0.5 MPa and 23°C and had a strain capacity of 3%. Carbonation conditions were optimized at the bench-scale and then utilized to create full-scale CO 2 -cured ECC railroad ties that were field tested on a train track. Rail ties were selected for this initial assessment of CO 2 storage in precast concrete materials due to the large market for concrete ties in the railroad industry. Although the full-scale rail ties passed all of the required American Railway Engineering and Maintenance-of-Way Association qualifying mechanical tests, on-track testing of the CO 2 -cured ECC rail ties was unsuccessful due to fiber alignment in the ECC the during the rail tie casting process which prevented the material from achieving the expected level of strain capacity. This result highlights the challenge in scaling up bench-scale processes to full-scale product manufacturing and requires additional investigation into the casting process of large-scale infrastructure elements using ECC combined with carbonation curing. Life cycle assessment of a CO 2 -cured ECC rail tie versus a traditional concrete rail tie indicates that the ECC tie can have lifecycle carbon savings of between 11% and 51% depending on how much longer its useful lifetime is compared to traditional concrete rail ties. Both carbon and cost savings are driven by a reduction in the need to replace broken rail ties, so the key factor is the extent to which a CO 2 -cured ECC rail tie will have increased lifetime durability compared to alternative rail ties.
Explore the source record for details and available documents.
One of the most important responsibilities chemical owners at Los Alamos National Laboratory (LANL) have is to ensure the safety of the chemicals they own. An important consideration is how chemicals react to their environment. In the case of 2-propanol, a common solvent found in research laboratories used often in manufacturing and analytical processes, it can develop peroxides with exposure to light. 2-Propanol is classified as a Group B (class 3) peroxide-forming solvent. However, there is a dearth of literature that summarizes the risks surrounding peroxide formation in 2-propanol (IPA), leading to a lack of awareness of these hazards in the chemistry community.
Explore the source record for details and available documents.
This guide was created to empower Energy Storage for Social Equity (ES4SE) community members to learn more about power systems, energy distribution, renewable energy, and battery storage systems. It was developed in an accessible format for audiences of varied backgrounds and requires no previous experience in energy storage. It is intended to serve readers as both an educational and reference document as they consider, procure, and deploy power systems that include battery energy storage technologies and microgrids in their communities. By providing an introductory overview of the basics of electricity, power generation, and household energy consumption and loads, this guide prepares readers to learn even more about battery energy storage, microgrid systems, and the sizing of solar and battery systems.
Fact sheet on the 45Q tax credit. 45Q was created in 2008 as a tax credit to incentivize the development of carbon capture, utilization, and storage (CCUS) projects.
As part of the Cyclotron Road program, Inlyte Energy, Inc. investigated low-cost energy storage for the electricity grid via batteries manufactured from abundant materials. Low-cost energy storage can solve the problem of the intermittency of wind and solar power, thereby allowing these sources of energy to scale more rapidly. The project team explored development of a Na-FeCl 2 battery—which had as its starting redox-active materials the abundant materials table salt (NaCl) and iron—that can operate safely and efficiently over a long lifetime, and be produced at very low-cost. The Na-FeCl 2 battery is architecturally similar to the commercialized Zebra (Na-NiCl 2 ) batteries, which have demonstrated safety, efficiency, and long lifetime. This project explored and assessed key design changes, including the use of planar Na-β’’-alumina solid electrolyte and lower temperatures (~200 °C) with polymer seals aimed at decreasing costs.
This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.
Guidebook contains information about EPAct alternative fuels regulations for fleets, flexible fuel vehicles, E85 properties and specifications, and E85 handling and storage guidelines.
Results of measurements of vector and tensor polarization of a deuteron beam in the storage ring COSY have been published by the SPIN{at}COSY collaboration. In this experiment a RF Dipole was used that produced spin flip. The strength of the RFD-induced depolarizing resonance was calculated from the amount of spin flipping and the results shown in the figures of the cited paper. In this note we present the simulation of the experimental data (vector polarization) with the spin tracking code Spink.
The primary project goal is to develop and test tools for optimization of ECBM recovery and geologic storage of CO{sub 2} in coalbeds, in addition to tools for monitoring CO{sub 2} sequestration in coalbeds to support risk assessment. Three critical topics identified are (1) the integrity of coal bed methane geologic and engineered systems, (2) the optimization of the coal bed storage process, and (3) reliable monitoring and verification systems appropriate to the special conditions of CO{sub 2} storage and flow in coals.
Explore the source record for details and available documents.
The CO{sub 2} stream injecting into the Weyburn-Midale field can be generally classified as a reducing stream with residual H{sub 2}S and low-molecular weight hydrocarbons. The composition of the CO{sub 2} gas stream from the Dakota Gasification Company is reported to be 95% CO{sub 2}, 4% hydrocarbons, and 1% H{sub 2}S by volume (Huxley 2006). In addition to the H{sub 2}S introduced at the injection wells, significant concentrations of H{sub 2}S are thought to have been produced in-situ by sulfate reducing bacteria from previous water floods for enhanced oil production. Produced gas compositions range in H{sub 2}S concentrations from 1 to 6 volume percent. The produced gas, including the trace impurities, is re-injected into the field. Although there is no evidence for inorganic reduction of SO{sub 4}{sup 2-} to H{sub 2}S at the Weyburn-Midale field, Sitchler and Kazuba (2009) suggest that SO{sub 4}{sup 2-} can be inorganically reduced to elemental sulfur in highly reducing environments based on a natural analog study of the Madison Formation in Wyoming. They propose that elevated concentrations of CO{sub 2} dissolve anhydrite to produce the sulfate that is then reduced. Oxidizing CO{sub 2} streams with residual O{sub 2} and SO{sub 2} typical of streams captured from oxyfuel and post combustion processes are not presently an issue at the Weyburn-Midale field. However it is possible that the oxidizing CO{sub 2} streams may be injected in the future in carbonate reservoirs similar to the Weyburn-Midale field. To date there are few modeling and experimental studies that have explored the impact of impurity gases in CO{sub 2} streams targeted for geologic storage (Gale 2009). Jacquemet et al (2009) reviewed select geochemical modeling studies that explored the impact of SO{sub 2} and H{sub 2}S impurities in the waste streams (Gunter et al., 2000, Knauss et al., 2005, Xu et al., 2007). These studies collectively show that SO{sub 2} significantly reduces the pH when oxidized to H{sub 2}SO{sub 4} causing enhanced dissolution of carbonate minerals and some sulfate mineral precipitation. Low pH results in higher mineral solubility and faster dissolution rates and is thought to enhance porosity and permeability near the injection well when trace amounts of SO{sub 2} is injected with CO{sub 2}. The impact of H{sub 2}S on storage reservoir performance appears to more subtle. Knauss et al (2005) report no significant impacts of injection of CO{sub 2} gas streams with and without H{sub 2}S (1 M Pascal H{sub 2}S + 8.4 M Pascal CO{sub 2}) in simulations of CO{sub 2} storage in the Frio sandstone formation. Geochemical reactions for H{sub 2}S impurities include enhance field alkalinity and reaction with iron bearing minerals that may delay breakthrough of H{sub 2}S relative to CO{sub 2}. Emberley et al. (2005) report that half of the alkalinity measured at monitoring wells at the Weyburn-Midale field is due to HS{sup -}. Schoonen and Xu (2004) report that H{sub 2}S can be sequestered as pyrite in sandstones and carbonates by dissolving iron hydroxides and iron-bearing clays. Similarly, Gunter et al (2000) propose the that siderite converts to iron sulfides when it is reacted with H{sub 2}S. The geochemical reactions between H{sub 2}S and iron bearing minerals together with the high solubility of H{sub 2}S relative to CO{sub 2} may contribute to the delayed break though of H{sub 2}S in experiments. A few core flood experiments have shown that the injection of supercritical CO{sub 2} into carbonate aquifers has the potential to significantly alter the porosity in the absence of trace gases such as SO{sub 2} and H{sub 2}S. Luquot and Gouze (2009) documented a 2% porosity increase in carbonate cores when rock-water interactions were transport limited and solution concentrations were closer to equilibrium and a 4% porosity increase when rock-water interactions were reaction limited and solution compositions were further from equilibrium. Similarly Le Guen et al (2007) used x-ray micro-tomography and geochemistry to show that porosity significantly increases when reacted with pure CO{sub 2}. While both of these studies nicely illustrate the relationship between reaction kinetics, thermodynamics, and porosity changes using x-ray micro-tomography, actual changes in a reservoir may be significantly lower because the input brines used in these studies were significantly dilute and below mineral carbonate saturation. The objective of the simulations reported was to explore viable experimental parameters for CO{sub 2} core flood experiments designed to investigate the impact of CO{sub 2} on porosity and permeability in the Weyburn-Midale storage reservoir. We describe the simulation results for core flood experiments in which formation waters that are equilibrated with supercritical CO{sub 2} at 60 C and 14.7 M Pascals react with three different flow units within the Midale formation.
Guidebook contains information about EPAct alternative fuels regulations for fleets, flexible fuel vehicles, E85 properties and specifications, and E85 handling and storage guidelines.
Abstract not provided.
Abstract not provided.
Abstract not provided.