Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

SU-F-T-370: A Fast Monte Carlo Dose Engine for Gamma Knife

Purpose: To develop a fast Monte Carlo dose calculation algorithm for Gamma Knife. Methods: To make the simulation more efficient, we implemented the track repeating technique on GPU. We first use EGSnrc to pre-calculate the photon and secondary electron tracks in water from two mono-energy photons of 60Co. The total photon mean free paths for different materials and energies are obtained from NIST. During simulation, each entire photon track was first loaded to shared memory for each block, the incident original photon was then splitted to Nthread sub-photons, each thread transport one sub-photon, the Russian roulette technique was applied for scattered and bremsstrahlung photons. The resultant electrons from photon interactions are simulated by repeating the recorded electron tracks. The electron step length is stretched/shrunk proportionally based on the local density and stopping power ratios of the local material. Energy deposition in a voxel is proportional to the fraction of the equivalent step length in that voxel. To evaluate its accuracy, dose deposition in a 300mm*300mm*300mm water phantom is calculated, and compared to EGSnrc results. Results: Both PDD and OAR showed great agreements (within 0.5%) between our dose engine result and the EGSnrc result. It only takes less than 1 min for every simulation, being reduced up to ∼40 times compared to EGSnrc simulations. Conclusion: We have successfully developed a fast Monte Carlo dose engine for Gamma Knife.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-13: Toward Heavy Ion Computed Tomography with Carbon Ions: A Monte Carlo Study

Purpose: In the present Monte Carlo study, we investigated the use of Carbon ions for computed tomography (CT) with a relatively low imaging dose. This will enable us to avoid any conversion of X-ray CT numbers to the relative stopping power (or relative electron density) values and the associated uncertainties in Carbon dose calculation. Methods: In the first stage, we studied the propagation of Carbon nuclei through a water phantom using the Geant4 specially to understand their lateral displacement inside the phantom. In the second stage, we used our GPU-based Monte Carlo code, which has been cross validated against Geant4, to create the 2D map of the water equivalent path length (WEPL) inside a human head size phantom by acquiring 240 projections each 1.5° apart. Subsequently the 3D relative electron density map of the phantom was reconstructed from the 2D WEPL map using the Algebraic Reconstruction Technique (ART) coupled with total variation (TV) minimization Results: A high quality image of the relative electron density inside the phantom was reconstructed by ARTTV. The mean relative error between the reconstructed image for low contrast object (PMMA) was about 1.74%. The delivered dose per scan at the center of the phantom was about 0.1 Gy. Conclusion: We have been able to obtain a 3D map of the electron density using a human head size phantom while keeping the delivered dose to relatively low value. Using the GPU capabilities of our simulation engine, we believe that a real time CT with Carbon ions could be a reality in future.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP1-04: Evaluating DECT Vs SECT Range Differences in Proton Therapy Using Clinical Data

Purpose: Range uncertainty from X-ray CT number conversion to stopping power ratio (SPR) is one of the key factors limiting the potential of proton therapy. The large margins required for deep seated tumors degrade the organ sparing achievable with the technology. Of interest is the application of dual energy CT (DECT) to SPR estimation. In this planning study proton range differences between SECT and DECT have been quantified for brain cases. Methods: A last generation dual source DECT scanner was used to acquire SECT (150 kVp with Sn filtration) and DECT (additionally 90 kVp) scans of phantoms and 5 head trauma patients, acting as surrogate cancer patients. Phantom materials were characterized in terms of SPR in a particle beam to obtain reference values. IMPT treatment plans were generated on the basis of SECT and DECT SPR images for hypothetical brain tumors using a short and a long beam path. Range differences between SECT and DECT from plan recalculations were evaluated in beam-eye-view (BEV) by comparing the 80% isodose. Results: For the 18 phantom materials the SECT RMS SPR errors were 2.6% compared to 1.1% for DECT. Group median relative range differences between SECT and DECT plans were −1.0% for the short beam path over the 5 patients investigated in this study. For the long beam path the median difference was −1.4%. These relative range differences corresponded to −0.5 mm and −1.4 mm shifts respectively. Conclusion: This is the first study performing proton therapy treatment planning on DECT patient images. Important range differences of more than 1 mm were observed between SECT and DECT treatment plans, and DECT SPR accuracy was found superior on the basis of phantom measurements. While the patients investigated in this study did not have brain tumors, the findings we observed should apply to cancer patients. Deutsche Forschungsgemeinschaft (MAP); Bundesministerium fur Bildung und Forschung (01IB13001)

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-03: Accurate Tissue Characterization for Monte Carlo Dose Calculation Using Dual-and Multi-Energy CT Data

Purpose: To develop a general method for human tissue characterization with dual-and multi-energy CT and evaluate its performance in determining elemental compositions and the associated proton stopping power relative to water (SPR) and photon mass absorption coefficients (EAC). Methods: Principal component analysis is used to extract an optimal basis of virtual materials from a reference dataset of tissues. These principal components (PC) are used to perform two-material decomposition using simulated DECT data. The elemental mass fraction and the electron density in each tissue is retrieved by measuring the fraction of each PC. A stoichiometric calibration method is adapted to the technique to make it suitable for clinical use. The present approach is compared with two others: parametrization and three-material decomposition using the water-lipid-protein (WLP) triplet. Results: Monte Carlo simulations using TOPAS for four reference tissues shows that characterizing them with only two PC is enough to get a submillimetric precision on proton range prediction. Based on the simulated DECT data of 43 references tissues, the proposed method is in agreement with theoretical values of protons SPR and low-kV EAC with a RMS error of 0.11% and 0.35%, respectively. In comparison, parametrization and WLP respectively yield RMS errors of 0.13% and 0.29% on SPR, and 2.72% and 2.19% on EAC. Furthermore, the proposed approach shows potential applications for spectral CT. Using five PC and five energy bins reduces the SPR RMS error to 0.03%. Conclusion: The proposed method shows good performance in determining elemental compositions from DECT data and physical quantities relevant to radiotherapy dose calculation and generally shows better accuracy and unbiased results compared to reference methods. The proposed method is particularly suitable for Monte Carlo calculations and shows promise in using more than two energies to characterize human tissue with CT.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-09: Thermoacoustic Range Verification with Perfect Co-Registered Overlay of Bragg Peak onto Ultrasound Image

Purpose: The potential of particle therapy has not yet been fully realized due to inaccuracies in range verification. The purpose of this work was to correlate the Bragg peak location with target structure, by overlaying thermoacoustic localization of the Bragg peak onto an ultrasound image. Methods: Pulsed delivery of 50 MeV protons was accomplished by a fast chopper installed between the ion source and the inflector of the 88″ cyclotron at Lawrence Berkeley National Lab. 2 Gy were delivered in 2 µs by a beam with peak current of 2 µA. Thermoacoustic emissions were detected by a cardiac array and Verasonics V1 ultrasound system, which also generated a grayscale ultrasound image. 1024 thermoacoustic pulses were averaged before filtering and one-way beamforming focused signal onto the Bragg peak location with perfect co-registration to the ultrasound images. Data was collected in a room temperature water bath and gelatin phantom with a cavity designed to mimic the intestine, in which gas pockets can displace the Bragg peak. Experiments were performed with the cavity both empty and filled with olive oil. Results: In the waterbath overlays of the Bragg peak agreed with Monte Carlo simulations to within 800±170 µm. Agreement within 1.3 ± 0.2 mm was achieved in the gelatin phantom, although relative stopping powers were estimated only to first order from CT scans. Protoacoustic signals were detected after travel from the Bragg peak through 29 mm and 65 mm of phantom material when the cavity was empty and full of olive oil, respectively. Conclusion: Protoacoustic range verification is feasible with a commercial clinical ultrasound array, but at doses exceeding the clinical realm. Further optimization of both transducer array and injection line chopper is required to enable range verification within a 2 Gy dose limit, which would enable online adaptive treatment. This work was supported in part by a UWM Intramural Instrumentation Grant and by the Director, Office of Science, Office of Nuclear Physics, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. YMQ was supported by a UWM-OUR summer fellowship.

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-07: MRI-Linac Dosimetry: Parameters That Change in a Magnetic Field

Purpose: In MRI-linac integrated systems, the presence of the magnetic (B-)field has a large impact of the dose-distribution and the dose-responses of detectors; yet established protocols and previous experience may lead to assumptions about the commissioning process that are no longer valid. This study quantifies parameters that change when performing dosimetry with an MRI-linac including beam quality specifiers and the effective-point-of-measurement (EPOM) of ionization chambers. Methods: We used the Geant4 Monte Carlo code for this work with physics parameters that pass the Fano cavity test to within 0.1% for the simulated conditions with and without a 1.5 T B-field. A point source model with the energy distribution of an MRI-linac beam was used with and without the B-field to calculate the beam quality specifiers %dd(10)× and TPR{sup 20}{sub 10}, the variation of chamber response with orientation and the how the B-field affects the EPOM of ionization chambers by comparing depth-dose curves calculated in water to those generated by a model PTW30013 Farmer chamber. Results: The %dd(10)× changes by over 2% in the presence of the B-field while the TPR{sup 20}{sub 10} is unaffected. Ionization chamber dose-response is known to depend on the orientation w.r.t. the B-field, but two alternative perpendicular orientations (anti-parallel to each other) also differ in dose-response by over 1%. The B-field shifts the EPOM downstream (closer to the chamber center) but it is also shifted laterally by 0.27 times the chamber’s cavity radius. Conclusion: The EPOM is affected by the B-field and it even shifts laterally. The relationship between %dd(10)× and the Spencer-Attix stopping powers is also changed. Care must be taken when using chambers perpendicular to the field as the dose-response changes depending on which perpendicular orientation is used. All of these effects must be considered when performing dosimetry in B-fields and should be accounted for in future dosimetry protocols. This project was partially funded by Elekta Ltd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards 3D printed multifunctional immobilization for proton therapy: Initial materials characterization

Purpose: 3D printing technology is investigated for the purpose of patient immobilization during proton therapy. It potentially enables a merge of patient immobilization, bolus range shifting, and other functions into one single patient-specific structure. In this first step, a set of 3D printed materials is characterized in detail, in terms of structural and radiological properties, elemental composition, directional dependence, and structural changes induced by radiation damage. These data will serve as inputs for the design of 3D printed immobilization structure prototypes. Methods: Using four different 3D printing techniques, in total eight materials were subjected to testing. Samples with a nominal dimension of 20 × 20 × 80 mm{sup 3} were 3D printed. The geometrical printing accuracy of each test sample was measured with a dial gage. To assess the mechanical response of the samples, standardized compression tests were performed to determine the Young’s modulus. To investigate the effect of radiation on the mechanical response, the mechanical tests were performed both prior and after the administration of clinically relevant dose levels (70 Gy), multiplied with a safety factor of 1.4. Dual energy computed tomography (DECT) methods were used to calculate the relative electron density to water ρ{sub e}, the effective atomic number Z{sub eff}, and the proton stopping power ratio (SPR) to water SPR. In order to validate the DECT based calculation of radiological properties, beam measurements were performed on the 3D printed samples as well. Photon irradiations were performed to measure the photon linear attenuation coefficients, while proton irradiations were performed to measure the proton range shift of the samples. The directional dependence of these properties was investigated by performing the irradiations for different orientations of the samples. Results: The printed test objects showed reduced geometric printing accuracy for 2 materials (deviation > 0.25 mm). Compression tests yielded Young’s moduli ranging from 0.6 to 2940 MPa. No deterioration in the mechanical response was observed after exposure of the samples to 100 Gy in a therapeutic MV photon beam. The DECT-based characterization yielded Z{sub eff} ranging from 5.91 to 10.43. The SPR and ρ{sub e} both ranged from 0.6 to 1.22. The measured photon attenuation coefficients at clinical energies scaled linearly with ρ{sub e}. Good agreement was seen between the DECT estimated SPR and the measured range shift, except for the higher Z{sub eff}. As opposed to the photon attenuation, the proton range shifting appeared to be printing orientation dependent for certain materials. Conclusions: In this study, the first step toward 3D printed, multifunctional immobilization was performed, by going through a candidate clinical workflow for the first time: from the material printing to DECT characterization with a verification through beam measurements. Besides a proof of concept for beam modification, the mechanical response of printed materials was also investigated to assess their capabilities for positioning functionality. For the studied set of printing techniques and materials, a wide variety of mechanical and radiological properties can be selected from for the intended purpose. Moreover the elaborated hybrid DECT methods aid in performing in-house quality assurance of 3D printed components, as these methods enable the estimation of the radiological properties relevant for use in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Feasibility study of heavy ion physics program at NICA

There are strong experimental and theoretical evidences that in collisions of heavy ions at relativistic energies nuclear matter undergoes a phase transition to the deconfined state—Quark Gluon Plasma. The caused energy region of such transition was not found at high energy at SPS and RHIC and search for this energy is shifted to lower energies, which will be covered by the future NICA (Dubna), FAIR (Darmstadt) facilities and BES II at RHIC. Fixed target and collider experiments at the NICA facility will work at the energy range from a few AGeV up to √( S{sub NN}) = 11 GeV GeV and will study the most interesting area on the nuclear matter phase diagram. The most remarkable results were observed in the study of collective phenomena occurring in the early stage of nuclear collisions. Investigation of the collective flow will provide information on Equation of State (EoS) for nuclear matter. Study of the Event-by-Event fluctuations and correlations can give us signals of critical behavior of the system. Femtoscopy analysis provides the space-time history of the collisions. Also, it was found that baryon stopping power revealing itself as a “wiggle” in excitation function of curvature of the (net)proton rapidity spectrum relates to the order of the phase transition. The available observations of an enhancement of dilepton rates at low invariant masses may serve as a signal of the chiral symmetry restoration in hot and dense matter. Due to this fact, measurements of the dilepton spectra are considered to be an important part of the NICA physics program. The study of strange particles and hypernuclei production gives additional information on the EoS and “strange” axis of the QCD phase diagram. In this paper a feasibility of the considered investigations is shown by the detailed Monte Carlo simulations applied to the planned experiments (BM@N, MPD) at NICA.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-time time-dependent density functional theory in Quantum Espresso and related codes

A set of subroutines that interact with an existing computer program, Quantum Espresso (QE), that takes a set of electronic orbitals from QE and propagates them forward in time in response to a number of perturbations. These perturbations include the motion of ions and a wide spectrum of applied electromagnetic fields (e.g., static magnetic fields, slowly-varying electric fields, x-rays, etc.). From the time evolution of the electronic orbitals comes time-varying values of physical observables like the electronic charge and current densities and atomic forces. These are further post-processed to yield properties of interest like stopping powers, conductivities, and the dynamic structure factor. The electronic orbitals are described in a plane wave basis and the equations of motion are carried out using a unitary or approximately unitary time propagation algorithm. Related work will include subroutines for interfacing this capability, as well as others that already exist within QE, with a fork of QE that is more extensible and modular.SAND2019-12611 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Baczewski, Andrew↗

SOURCES4D

SOURCES is a code for computing neutron source rates and spectra from spontaneous fission (including delayed neutrons) and (alpha,n) reactions in homogeneous materials and (alpha,n) reactions in single-interface and two-interface geometries. SOURCES is a Los Alamos National Laboratory (LANL) code that is written in FORTRAN and distributed through the Radiation Safety Information Computation Center (RSICC). LANL’s last release of SOURCES to RSICC was SOURCES4C in 2002. This disclosure covers the latest version of SOURCES, SOURCES4D. This version adds sensitivity capabilities for (alpha,n) sources in homogeneous materials. Specifically, SOURCES4D writes new output that can be used to calculate, in post-processing, first and second derivatives of the (alpha,n) source rate density and spectrum with respect to nuclide densities in a homogeneous material and first derivatives of the (alpha,n) source rate density and spectrum with respect to nuclide stopping powers and (alpha,n) cross sections (nuclear data). These derivatives are useful for uncertainty quantification, predictive modeling, and other applications in neutron transport problems.

Favorite, Jeffrey A.↗

Ion Fast Ignition-Establishing a Scientific Basis for Inertial Fusion Energy --- Final Report

The Fast Ignition (FI) Concept for Inertial Confinement Fusion (ICF) has the potential to provide a significant advance in the technical attractiveness of Inertial Fusion Energy reactors. FI differs from conventional ?central hot spot? (CHS) target ignition by decoupling compression from heating: using a laser (or heavy ion beam or Z pinch) drive pulse (10?s of nanoseconds) to create a dense fuel and a second, much shorter (~10 picoseconds) high intensity pulse to ignite a small volume within the dense fuel. The compressed fuel is opaque to laser light. The ignition laser energy must be converted to a jet of energetic charged particles to deposit energy in the dense fuel. The original concept called for a spray of laser-generated hot electrons to deliver the energy; lack of ability to focus the electrons put great weight on minimizing the electron path. An alternative concept, proton-ignited FI, used those electrons as intermediaries to create a jet of protons that could be focused to the ignition spot from a more convenient distance. Our program focused on the generation and directing of the proton jet, and its transport toward the fuel, none of which were well understood at the onset of our program. We have developed new experimental platforms, diagnostic packages, computer modeling analyses, and taken advantage of the increasing energy available at laser facilities to create a self-consistent understanding of the fundamental physics underlying these issues. Our strategy was to examine the new physics emerging as we added the complexity necessary to use proton beams in an inertial fusion energy (IFE) application. From the starting point of a proton beam accelerated from a flat, isolated foil, we 1) curved it to focus the beam, 2) attached the foil to a superstructure, 3) added a side sheath to protect it from the surrounding plasma, and finally 4) studied the proton beam behavior as it passed through a protective end cap into plasma. We built up, as we proceeded, a self-consistent picture of the quasi-neutral plasma jet that is the proton beam that, for the first time, included the role of the hot electrons in shaping the jet. Controlling them?through design of the accelerating surface and its connection to the surrounding superstructure?is critical; their uniform spread across the proton accelerating area is vital, but their presence in the jet opposes focus; their electron flow away from the acceleration area reduces conversion efficiency but can also increase focusing ability. The understanding emerging from our work and the improved simulation tools we have developed allow designing structures that optimize proton beams for focused heating. Our findings include: ? The achievable focus of proton beams is limited by the thermal pressure gradient in the laser-generated hot electrons that drive the process. This bending can be suppressed using a controlled flow of hot electrons along the surrounding cone wall, which induces a local transverse focusing sheath electric field. The resultant (vacuum-focused) spot can meet IFE requirements. ? Confinement of laser-generated electrons to the proton accelerating area can be achieved by supporting targets on thin struts. That increases laser-to-proton conversion energy by ~50%. As noted above, confinement should not be total; necessary hot-electron leakage into the surrounding superstructure for proton focusing can be controlled by with the strut width/number. ? Proton jets are further modified as they enter the fuel through the superstructure?s end cap. They can generate currents during that transit that further focus the proton beams. We developed a new ion stopping module for LSP code that properly accounted for changes in stopping power with ionization (e.g. temperature), and will be using it in future studies. The improved understanding, new experimental platforms, and the self-consistent modeling capability allow researchers a new ability to investigate the interaction of large ion currents with warm dense matter. That is of direct importance to the creation and investigation of all aspects of warm dense matter as well as to proton-ignited FI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Implementation of Time-Dependent Density Functional Theory for Extended Systems in Extreme Environments

In recent years, DFT-MD has been shown to be a useful computational tool for exploring the properties of WDM. These calculations achieve excellent agreement with shock compression experiments, which probe the thermodynamic parameters of the Hugoniot state. New X-ray Thomson Scattering diagnostics promise to deliver independent measurements of electronic density and temperature, as well as structural information in shocked systems. However, they require the development of new levels of theory for computing the associated observables within a DFT framework. The experimentally observable x-ray scattering cross section is related to the electronic density-density response function, which is obtainable using TDDFT - a formally exact extension of conventional DFT that describes electron dynamics and excited states. In order to develop a capability for modeling XRTS data and, more generally, to establish a predictive capability for first principles simulations of matter in extreme conditions, real-time TDDFT with Ehrenfest dynamics has been implemented in an existing PAW code for DFT-MD calculations. The purpose of this report is to record implementation details and benchmarks as the project advances from software development to delivering novel scientific results. Results range from tests that establish the accuracy, efficiency, and scalability of our implementation, to calculations that are verified against accepted results in the literature. Aside from the primary XRTS goal, we identify other more general areas where this new capability will be useful, including stopping power calculations and electron-ion equilibration.

97 MATHEMATICS AND COMPUTING↗

Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector

Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Elastic Recoil Detection Technique for Quantifying Light Isotope Concentrations in Irradiated TPBAR Materials.

The National Nuclear Security Administration's Tritium Sustainment Program is responsible for the design, development, demonstration, testing, analysis, and characterization of tritium-producing burnable absorber rods (TPBARs) and their components, in addition to producing tritium for the nation's strategic stockpile. The FY18 call for proposals included the specific basic science research topic, "Demonstration and evaluation of advanced characterization methods, particularly for quantifying the concentration of light isotopes ( 1 H, 2 H, and 4 He, 6 Li, and 7 Li) in metal or ceramic matrices". A project IWO-389859 was awarded to the Ion Beam Lab (IBL) at Sandia-NM in FY18. This reports the success we had in developing and demonstrating such a method: 42 MeV Si + 7 from the IBL' s Tandem was used to recoil these light isotopes into special detectors that separated all these isotopes by simultaneously measuring the energy and stopping power of these reoils. This technique, called Heavy Ion - Elastic Recoil Detection or HI-ERD, accurately measured the enriched 6 Li/Li-total of 0.246 +- 0.016, compared to the known value of 0.239. The isotopes 1 H, 2 H, 4 He, 6 Li and 7 Li were also measured. (page intentionally left blank)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Data – Benchmarking 19 F(α,n) Yield Data for Nuclear Safeguards

Fluorine compounds of U and Pu are ubiquitous in the nuclear fuel cycle, so F(α,n) neutrons are an important signature and quantitative source term that needs to be understood for physics-based interpretation of nondestructive assay measurements. Historically there have been large differences in the basic nuclear data for this reaction reported by various groups. UF 6 is the most prominent material in the nuclear fuel cycle, with the potential for short-term production into weaponizable form. Verification of bulk quantities, natural feed, depleted tails, and especially low enriched product in cylinders is particularly important. The principal physical measurement is neutron counting. For enriched material, the 19 F(α,n) reaction, driven by 234U, is the dominant source of neutrons. Basic nuclear data, cross sections, needed to calculate the yield, as well as information on the source spectrum for sensitivity studies are sparse and highly discrepant. This limits defensible physics-based performance evaluations. The same applies to holdup and criticality studies in which hydrated uranyl fluoride is the material of interest which accumulates in enrichment facilities. In the future we anticipate that the physics community will have made improved accelerator-based measurements and undertaken a more thorough evaluation and adjustment of all relevant available data. But in the short term, this does not help the safeguards community face the pressing real-world nondestructive assay requirements. To address this need, we have performed quality neutron measurements on UF6 materials using well-known material and high-capability neutron counters. A robust determination of the n/s/g of 234 U in UF 6 was generated along with a scientifically defensible uncertainty analysis. The weighted average value of the neutron yield is 509 n/s/g 234 U with a random uncertainty of approximately 1%. Dominant sources of systematic uncertainty are in the efficiency determination where we incur approximately 1.1% relative standard deviation associated with the 252 Cf reference source and about 0.9% uncertainty coming from the uncertainty in the F(α,n) spectrum. The stated uncertainties are an order of magnitude better than current data based on accelerator data reported in the literature. Aside from being of immediate and direct use by the safeguards community, this result will serve as an enduring integral benchmark for subsequent data evaluations that will need to match it in order to be credible. In addition to yield normalization, safeguards users of F(α,n) data also need guidance of the neutron emission spectrum. We have generated a neutron emission using a modified version of the well-known SOURCES 4C code, updated with new alpha stopping power coefficients, and a blended microscopic cross section data set. The yield and spectra are available in a form that MCNP users can readily use.

36 MATERIALS SCIENCE↗

Fabrication of Low-Cost Large-Volume Ceramic A 2 HfX 6 (A= Cs or Tl, X = Cl, Br, or I) Scintillators for Gamma Ray Detection (SBIR Phase I Final Technical Report)

Scintillator crystals play an important role in the radiation detection field. Widespread use of scintillators as gamma-ray detectors is largely generated by their extensive availability and tunable properties, such high light output, high stopping power (Z eff ), fast decay time, and good proportionality. Additionally, the cost for manufacturing a scintillation detector like NaI:Tl is usually considerably lower than the cost for manufacturing a semiconductor detector like CdZnTe. Because there is no such thing as an ideal scintillation material, an application requiring certain detection characteristics may incorporate a scintillator tailored to its specific properties. The vast variety of applications and requirements necessitates more research into new scintillation materials and/or better methods of producing existing materials.The goal of this project was to grow low cost and environmentally stable inorganic transparent ceramic scintillators with excellent gamma ray resolution, excellent energy proportionality, excellent detection efficiency due to high density (>5 g/cm 3 ) and very high Z eff (55-80), and good light yields (>40,000 ph/MeV). In Phase I Xtallized Intelligence, Inc. (XI, Inc) developed a novel ceramic fabrication technique to produce low cost and environmentally stable highly efficient inorganic transparent ceramic scintillators of various dimensions. XI, Inc., collaborating with Fisk University (Fisk), investigated the scintillation properties of these new ceramic scintillators and compared them to in their single crystal counterparts. The results of this Phase I project show that successful production of high-quality inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Both ceramic CHC and THC scintillators have achieved good performance close to the performance of their single crystal counterparts. Fabricating these inorganic ceramic scintillators mitigate many issues encountered during conventional bulk crystal growth by melt methods. Additional benefits of the ceramic fabrication technique include high production yield, low production cost, fast production time, and no material waste Inorganic transparent ceramic scintillators produced in this project will enhance cost effectiveness at the instrument level based on low projected cost of the proposed compounds, as much smaller crystal sizes would be required to achieve similar efficiency as current radioisotope identification devices (RIID’s) used in homeland security applications as well as spectrometers in high energy physics applications.

36 MATERIALS SCIENCE↗

Release of the NDI 2.2.0

The Nuclear Data Interface 2.2.0 has been released. It includes the addition of charged particle dE/dx (stopping power) data, the ability to read in NDI-formatted binary data, corrections to TN data, and other minor changes and bug fixes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Release of the NDI 2.2.0alpha

The Nuclear Data Interface 2.2.0alpha has been released. It includes the addition of charged particle dE/dx (stopping power) data, the ability to read in NDI-formatted binary data, corrections to TN data, CP 2011 and CP 2020 data, and other minor changes and bug fixes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗