Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SNAP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

KokkACC: Enhancing Kokkos with OpenACC

Template metaprogramming is gaining popularity as a high-level solution for achieving performance portability on heterogeneous computing resources. Kokkos is a representative approach that offers programmers high-level abstractions for generic programming while most of the device-specific code generation and optimizations are delegated to the compiler through template specializations. For this, Kokkos provides a set of device-specific code specializations in multiple back ends, such as CUDA and HIP. Unlike CUDA or HIP, OpenACC is a high-level and directive-based programming model. This descriptive model allows developers to insert hints (pragmas) into their code that help the compiler to parallelize the code. The compiler is responsible for the transformation of the code, which is completely transparent to the programmer. This paper presents an OpenACC back end for Kokkos: KokkACC. As an alternative to Kokkos’s existing device-specific back ends, KokkACC is a multi-architecture back end providing a high-productivity programming environment enabled by OpenACC’s high-level and descriptive programming model. Moreover, we have observed competitive performance; in some cases, KokkACC is faster (up to 9×) than NVIDIA’s CUDA back end and much faster than OpenMP’s GPU offloading back end. This work also includes implementation details and a detailed performance study conducted with a set of mini-benchmarks (AXPY and DOT product) and three mini-apps (LULESH, miniFE and SNAP, a LAMMPS proxy mini-app).

Valero Lara, Pedro↗

Bio-inspired Bistable Piezoelectric Energy Harvester for Powering Animal Telemetry Tags: Concept Design and Preliminary Experimental Validation

This paper presents the concept design, preliminary experimental validation, and performance evaluation of a novel bio-inspired bi-stable piezoelectric energy harvester for self-powered animal telemetry tags. The overall concept design, which includes a bio-inspired attachment and a bi-stable piezoelectric energy harvester, is introduced firstly with a specific application example of marine fish tracking. The self-powered telemetry tag can be externally deployed on fish (dorsal fin) to monitor fish habitats, population, and underwater environment. Inspired by the Venus flytrap’s rapid shape transition, a bistable piezoelectric energy harvester is developed to scavenge energy from fish maneuvering and the surrounding fluid flow for a sustainable power supply. The bistability of the harvester is characterized by the measured force-displacement curve and double potential wells. A bluff body is integrated to the free end of the bistable piezoelectric energy harvester to enhance the structure-fluid interaction for the large-amplitude snap-through vibrations and higher voltage output. Controlled laboratory experiments are conducted in a water tank on the bio-inspired bi-stable piezoelectric energy harvester using a servo motor system to simulate fish swing motion at various conditions to evaluate the power generation performance. The preliminary underwater experimental results demonstrated that the proposed bio-inspired bi-stable piezoelectric could effectively converter fish swing motions into electricity. 17.25 mJ energy was obtained within 130 s under the peak-to-peak swing angle of 30o at 1.5 Hz in the capacitor charging experiments.

Qian, Feng↗

Evaluation of MatriXX for IMRT and VMAT dose verifications in peripheral dose regions

Purpose: MatriXX is a two-dimensional ion chamber array designed for IMRT/VMAT (RapidArc, IMAT, etc.) dose verifications. Its dosimetric properties have been characterized for megavoltage beams in a number of studies; however, to the best of the authors' knowledge, there is still a lack of an investigation into its performance in the peripheral or low dose regions. In this work, the authors have carried out a systematic study on this issue. Methods: The authors compare the performance of MatriXX with a cylindrical ion chamber in solid water phantoms in the peripheral dose regions. The comparisons are performed for a number of typical irradiation conditions that involve different gantry and/or MLC motions, field sizes, and distances to the target including static gantry/open fields, static gantry/sweeping MLC gap (mimicking an IMRT delivery), dynamic gantry/oscillating sweeping MLC gap (mimicking a VMAT delivery), as well as clinical IMRT and VMAT plans. Results: MatriXX, when used according to the manufacturer's recommendations, is found to disagree with an ion chamber in peripheral dose regions. This disagreement has been attributed to four types of MatriXX errors, namely, positive bias, over-response to scattered doses, round-off error, and angular dependence, all of which contribute to dose inaccuracies in the peripheral regions. The positive bias, which is independent of the dose level, is cumulative when MatriXX operates in the movie mode. The accumulation is proportional to the number of movie frames (snaps) when the sampling time is greater than 500 ms and is proportional to the overall movie time for a sampling time shorter than 500 ms. This behavior suggests multiple sources of the bias. MatriXX is also found to over-respond to peripheral doses by about 2.0% for the regions investigated in this work (3-15 cm from the field edge), where phantom scatter and collimator scatter dominate. Round-off error is determined to be due to insufficient precision in conversion of the raw signals to MatriXX software data for low doses. Angular dependence is defined as the dose response of MatriXX at different gantry angles. Up to 8% difference in detector response has been observed between 0 deg. and 180 deg. Possible sources of these errors are discussed and a correction method is suggested. With corrections, MatriXX shows good agreement with the ion chamber in all cases involving different gantry and/or MLC dynamics, as well as the clinical plans. For both primary and peripheral doses, MatriXX shows dose linearity down to 2 cGy with an accuracy of within 1% of the local dose. Conclusions: The performance of MatriXX has been systematically evaluated in the peripheral dose regions. Major sources of error associated with MatriXX are identified and a correction method is suggested. This method has been successfully tested using both experimental and clinical plans. In all cases, good agreements between MatriXX and an ion chamber are achieved after corrections. The authors conclude that with proper corrections, MatriXX can be reliably used for peripheral dose measurements within the ranges studied.

60 APPLIED LIFE SCIENCES↗

Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study

Purpose: Target sites affected by organ motion require a time resolved (4D) dose calculation. Typical 4D dose calculations use 4D-CT as a basis. Unfortunately, 4D-CT images have the disadvantage of being a 'snap-shot' of the motion during acquisition and of assuming regularity of breathing. In addition, 4D-CT acquisitions involve a substantial additional dose burden to the patient making many, repeated 4D-CT acquisitions undesirable. Here the authors test the feasibility of an alternative approach to generate patient specific 4D-CT data sets. Methods: In this approach motion information is extracted from 4D-MRI. Simulated 4D-CT data sets [which the authors call 4D-CT(MRI)] are created by warping extracted deformation fields to a static 3D-CT data set. The employment of 4D-MRI sequences for this has the advantage that no assumptions on breathing regularity are made, irregularities in breathing can be studied and, if necessary, many repeat imaging studies (and consequently simulated 4D-CT data sets) can be performed on patients and/or volunteers. The accuracy of 4D-CT(MRI)s has been validated by 4D proton dose calculations. Our 4D dose algorithm takes into account displacements as well as deformations on the originating 4D-CT/4D-CT(MRI) by calculating the dose of each pencil beam based on an individual time stamp of when that pencil beam is applied. According to corresponding displacement and density-variation-maps the position and the water equivalent range of the dose grid points is adjusted at each time instance. Results: 4D dose distributions, using 4D-CT(MRI) data sets as input were compared to results based on a reference conventional 4D-CT data set capturing similar motion characteristics. Almost identical 4D dose distributions could be achieved, even though scanned proton beams are very sensitive to small differences in the patient geometry. In addition, 4D dose calculations have been performed on the same patient, but using 4D-CT(MRI) data sets based on variable breathing patterns to show the effect of possible irregular breathing on active scanned proton therapy. Using a 4D-CT(MRI), including motion irregularities, resulted in significantly different proton dose distributions. Conclusions: The authors have demonstrated that motion information from 4D-MRI can be used to generate realistic 4D-CT data sets on the basis of a single static 3D-CT data set. 4D-CT(MRI) presents a novel approach to test the robustness of treatment plans in the circumstance of patient motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-387: Achieving Optimal Patient Setup Imaging and Treatment Workflow Configurations in Multi-Room Proton Centers

Purpose: To simulate patient flow in proton treatment center under uncertainty and to explore the feasibility of treatment preparation rooms to improve patient throughput and cyclotron utilization. Methods: Three center layout scenarios were modeled: (S1: In-Tx room imaging) patient setup and imaging (planar/volumetric) performed in treatment room, (S2: Patient setup in preparation room) each treatment room was assigned with preparation room(s) that was equipped with lasers only for patient setup and gross patient alignment, and (S3: Patient setup and imaging in preparation room) preparation room(s) was equipped with laser and volumetric imaging for patient setup, gross and fine patient alignment. A 'snap' imaging was performed in treatment room. For each scenario, the number of treatment rooms and the number of preparation rooms serving each treatment room were varied. We examined our results (average of 100 16-hour (two shifts) working days) by evaluating patient throughput and cyclotron utilization. Results: When the number of treatment rooms increased ([from, to]) [1, 5], daily patient throughput increased [32, 161], [29, 184] and [27, 184] and cyclotron utilization increased [13%, 85%], [12%, 98%], and [11%, 98%] for scenarios S1, S2 and S3 respectively. However, both measures plateaued after 4 rooms. With the preparation rooms, the throughput and the cyclotron utilization increased by 14% and 15%, respectively. Three preparation rooms were optimal to serve 1-3 treatment rooms and two preparation rooms were optimal to serve 4 or 5 treatment rooms. Conclusion: Patient preparation rooms for patient setup may increase throughput and decrease the need for additional treatment rooms (cost effective). Optimal number of preparation rooms serving each gantry room varies as a function of treatment rooms and patient setup scenarios. A 5th treatment room may not be justified by throughput or utilization.

43 PARTICLE ACCELERATORS↗

SU-C-201-06: Utility of Quantitative 3D SPECT/CT Imaging in Patient Specific Internal Dosimetry of 153-Samarium with GATE Monte Carlo Package

Purpose: Patient-specific 3-dimensional (3D) internal dosimetry in targeted radionuclide therapy is essential for efficient treatment. Two major steps to achieve reliable results are: 1) generating quantitative 3D images of radionuclide distribution and attenuation coefficients and 2) using a reliable method for dose calculation based on activity and attenuation map. In this research, internal dosimetry for 153-Samarium (153-Sm) was done by SPECT-CT images coupled GATE Monte Carlo package for internal dosimetry. Methods: A 50 years old woman with bone metastases from breast cancer was prescribed 153-Sm treatment (Gamma: 103keV and beta: 0.81MeV). A SPECT/CT scan was performed with the Siemens Simbia-T scanner. SPECT and CT images were registered using default registration software. SPECT quantification was achieved by compensating for all image degrading factors including body attenuation, Compton scattering and collimator-detector response (CDR). Triple energy window method was used to estimate and eliminate the scattered photons. Iterative ordered-subsets expectation maximization (OSEM) with correction for attenuation and distance-dependent CDR was used for image reconstruction. Bilinear energy mapping is used to convert Hounsfield units in CT image to attenuation map. Organ borders were defined by the itk-SNAP toolkit segmentation on CT image. GATE was then used for internal dose calculation. The Specific Absorbed Fractions (SAFs) and S-values were reported as MIRD schema. Results: The results showed that the largest SAFs and S-values are in osseous organs as expected. S-value for lung is the highest after spine that can be important in 153-Sm therapy. Conclusion: We presented the utility of SPECT-CT images and Monte Carlo for patient-specific dosimetry as a reliable and accurate method. It has several advantages over template-based methods or simplified dose estimation methods. With advent of high speed computers, Monte Carlo can be used for treatment planning on a day to day basis.

60 APPLIED LIFE SCIENCES↗

SU-E-T-783: Using Matrixx to Determine Transit Dose Contribution Over Clinically Useful Limits of HDR Source Activity

Purpose: Most HDR brachytherapy treatment planning systems (TPS) use TG-43 formalism to calculate dose without including transit dose corrections. Historically, measurement of this contribution has required sophisticated apparatus unavailable in most hospitals. We use Matrixx to investigate several scenarios where transit dose contribution may effect a clinical treatment. Methods: Treatment plans were generated using Oncentra Brachy TPS (Version 4.3.0.410, Nucletron ) on a CT scan of a 24-catheter Freiburg applicator (Nucletron ) laid flat on the MatriXX (IBA) detector. This detector is an array of 1020 parallel plate ion chambers. All 24 catheters were digitized and dwells within a central square region of 5×5cm of the applicator were activated. Each of the active catheters had 6 dwells in increments of 1.0cm. The plans were normalized to 10mm. This places the 100% isodose line at the correct effective point of measurement, which lies half-way between the parallel plates of the ion chambers. It is also within the clinically relevant treatment depth for superficial applications. A total of 6 plans were delivered for 3 prescription doses, 1Gy, 2Gy and 4Gy using source activities of 2.9Ci and 11.2Ci. The MatriXX array was operated to capture dosimetric snaps every 500ms and yielded an integral dose at the end of treatment. Results: A comparison of integral dose from 2 different source activities shows that the transit dose contribution is larger when the source activity is higher. It is also observed that the relative transit dose contribution decreases as prescription dose increases. This is quantified by the Gamma analysis. Conclusion: We have demonstrated that the Matrixx detector can be used to evaluate the contribution for a HDR source during transit from the HDR afterloader to a dwell location, and between adjacent dwell locations.

60 APPLIED LIFE SCIENCES↗

Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2 mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.

60 APPLIED LIFE SCIENCES↗

SU-F-T-165: Daily QA Analysis for Spot Scanning Beamline

Purpose: The dosimetric results of our daily quality assurance over the last 8 years for discrete pencil beam scanning proton therapy will be presented. Methods: To perform the dosimetric checks, a multi-ion chamber detector is used, which consists of an array of 5 single parallel plate ion chambers that are aligned as a cross separated by 10cm each. The Tracker is snapped into a jig, which is placed on the tabletop. Different amounts of Solid Water buildup are added to shift the dose distribution. The dosimetric checks consist of 3 parts: position check, range check and volume dose check. Results: The average deviation of all position-check data were 0.2±1.3%. For the range check, the average deviation was 0.1%±1.2%, which also corresponds to a range stability of better than 1 mm over all measurements. The volumetric dose output readings were all within ±1% with the exception of 2 occasions when the cable to the dose monitor was being repaired. Conclusion: Morning QA using the Tracker device gives very stable dosimetric readings but is also sensitive to mechanical and output changes in the proton therapy delivery system.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-372: Surface and Peripheral Dose in Compensator-Based FFF Beam IMRT

Purpose: Flattening filter free (FFF) beams produce higher dose rates. Combined with compensator IMRT techniques, the dose delivery for each beam can be much shorter compared to the flattened beam MLC-based or compensator-based IMRT. This ‘snap shot’ IMRT delivery is beneficial to patients for tumor motion management. Due to softer energy, surface doses in FFF beam treatment are usually higher than those from flattened beams. Because of less scattering due to no flattening filter, peripheral doses are usually lower in FFF beam treatment. However, in compensator-based IMRT using FFF beams, the compensator is in the beam pathway. Does it introduce beam hardening effects and scattering such that the surface dose is lower and peripheral dose is higher compared to FFF beam MLC-based IMRT? Methods: This study applied Monte Carlo techniques to investigate the surface and peripheral doses in compensator-based IMRT using FFF beams and compared it to the MLC-based IMRT using FFF beams and flattened beams. Besides various thicknesses of copper slabs to simulate various thicknesses of compensators, a simple cone-shaped compensator was simulated to mimic a clinical application. The dose distribution in water phantom by the cone-shaped compensator was then simulated by multiple MLC defined FFF and flattened beams with various openings. After normalized to Dmax, the surface and peripheral dose was compared between the FFF beam compensator-based IMRT and FFF/flattened beam MLC-based IMRT. Results: The surface dose at the central 0.5mm depth was close between the compensator and 6FFF MLC dose distributions, and about 8% (of Dmax) higher than the flattened 6MV MLC dose. At 8cm off axis at dmax, the peripheral dose between the 6FFF and flattened 6MV MLC demonstrated similar doses, while the compensator dose was about 1% higher. Conclusion: Compensator does not reduce the surface doses but slightly increases the peripheral doses due to scatter inside compensator.

60 APPLIED LIFE SCIENCES↗

WE-H-207A-07: Image-Based Versus Atlas-Based Internal Dosimetry

Purpose: Monte Carlo (MC) simulation is known as the gold standard method for internal dosimetry. It requires radionuclide distribution from PET or SPECT and body structure from CT for accurate dose calculation. The manual or semi-automatic segmentation of organs from CT images is a major obstacle. The aim of this study is to compare the dosimetry results based on patient’s own CT and a digital humanoid phantom as an atlas with pre-specified organs. Methods: SPECT-CT images of a 50 year old woman who underwent bone pain palliation with Samarium-153 EDTMP for osseous metastases from breast cancer were used. The anatomical date and attenuation map were extracted from SPECT/CT and three XCAT digital phantoms with different BMIs (i.e. matched (38.8) and unmatched (35.5 and 36.7) with patient’s BMI that was 38.3). Segmentation of patient’s organs in CT image was performed using itk-SNAP software. GATE MC Simulator was used for dose calculation. Specific absorbed fractions (SAFs) and S-values were calculated for the segmented organs. Results: The differences between SAFs and S-values are high using different anatomical data and range from −13% to 39% for SAF values and −109% to 79% for S-values in different organs. In the spine, the clinically important target organ for Samarium Therapy, the differences in the S-values and SAF values are higher between XCAT phantom and CT when the phantom with identical BMI is employed (53.8% relative difference in S-value and 26.8% difference in SAF). However, the whole body dose values were the same between the calculations based on the CT and XCAT with different BMIs. Conclusion: The results indicated that atlas-based dosimetry using XCAT phantom even with matched BMI for patient leads to considerable errors as compared to image-based dosimetry that uses the patient’s own CT Patient-specific dosimetry using CT image is essential for accurate results.

60 APPLIED LIFE SCIENCES↗

Prompt radiation as a probe for fission dynamics

It is shown that the Strutinsky-Denisov induced polarization mechanism leads to the appearance of the prompt electric dipole radiation from fission fragments of {sup 235}Uby thermal neutrons in the domain of around 5 MeV. The probability of the radiation is at the level of 0.001 per fission, which is in agreement with experiment. The angular distribution exhibits left-right asymmetry with respect to the direction of the neutron polarization axis. That means that the emission of gamma quanta at the given angle depends on the neutron polarization. The asymmetry is at the level of 10{sup -3}. The study of this effect will give a direct information about the scission configuration, nuclear viscosity, and dissipation properties of the collective energy of the surface vibration in fragments with large amplitude. This will give a complete picture of the process of snapping back the nuclear surface.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ECP-copa/ExaMiniMD

ExaMiniMD is a proxy application for Molecular Dynamics (MD) codes such as LAMMPS. Its intend is to facilitate research and development on MD algorithms in particular in the context of CoDesign efforts with hardware vendors. Currently, ExaMiniMD implements a basic Lennard Jones two body potential as well as the SNAP many body potential, both of which are available in LAMMPS. It also includes basic neighbor list builds as well as constant energy integration as found in LAMMPS and other MD codes. A feature not generally available in other MD codes is a set of statistical correctness checks which will help other developers judge whether changes to the code still give correct answers. ExaMiniMD is using the Kokkos programming model to achieve performance portability and is able to run across all major HPC platforms (GPUs, ManyCore, CPUs).

Thompson, Aidan↗

Master State Distributed Estimator (masde)

The MSE technology provides a distributed state estimation scheme for power utilities by making it a real time dynamic system, versus the static snapshot method used today. This will allow utilities to verify power grid readings and identify false data on the communication network. The prevailing method of estimation takes all the data from the system into a single load flow equation at the utilities command center. This becomes a large algorithm that is very time consuming to solve, providing the engineers only snap shots of the system. The MFD distributes an algorithm to devises that are already installed at various locations on the power grid. This allows for much faster computer times because the algorithms contain magnitudes less data. When each distributed estimator completes its calculation, it sends the results back to the master device to check against all other distributed estimators.

Reen, DylanW.↗

Enhancing Kokkos with OpenACC

C++ template metaprogramming has emerged as a prominent approach for achieving performance portability in heterogeneous computing. Kokkos represents a notable paradigm in this domain, offering programmers a suite of high-level abstractions for generic programming while deferring much of the device-specific code generation and optimization to the compiler through template specializations. Kokkos furnishes a range of device-specific code specializations across multiple back ends, including CUDA and HIP. Diverging from conventional back ends, the OpenACC implementation presents a high-level, multicompiler, multidevice, and directive-based programming model. This paper presents recent advancements in the OpenACC back end for Kokkos (i.e., KokkACC) and focuses on its integration into the Kokkos ecosystem, exploration of automatic device selection capabilities to enhance productivity, and performance evaluation on modern hardware such as NVIDIA H100 GPUs. The study includes implementation details and a thorough performance assessment across various computational benchmarks, including minibenchmarks (AXPY and DOT product), miniapps (LULESH, MiniFE, and SNAP-LAMMPS), and a scientific kernel based on the lattice Boltzmann method.

Valero Lara, Pedro↗

Similar photosynthetic, but different yield responses of C3 and C4 crops to elevated O3

This dataset contains leaf photosynthetic and biochemical traits, plant biomass, and yield in five C3 crops (chickpea, rice, snap bean, soybean, wheat) and four C4 crops (sorghum, maize, Miscanthus × giganteus, switchgrass) grown under ambient and elevated O3 concentration ([O3]) in the field at free-air O3 concentration enrichment (O3-FACE) facilities over the past 20 years.

C3 and C4 crops↗

Comparative Critical Mass Calculations for NNL and ENDF/B-VIII.0 Zirconium Hydride Thermal Neutron Scattering Laws

Zirconium hydride (ZrH x ) is a moderator material for TRIGA reactors and historical space reactor systems, such as SNAP-10A. Thermal neutron scattering laws (TSL) for two phases of this material, δ and ε, have been previously evaluated by Naval Nuclear Laboratory (NNL) and submitted to the National Nuclear Data Center (NNDC) for inclusion in the US national ENDF/B-VIII.1 nuclear data library. In contrast to the current ENDF/B-VIII.0 TSL evaluations, which consider only a single phase, the new evaluations are derived from separate ab initio calculations for both phases and include coherent elastic effects of the zirconium sublattice. To estimate the impact of these changes to the TSL evaluation of this material, comparative critical mass calculations were performed with MC21 for homogenous mixtures of high- enriched uranium (HEU) and ZrH x in bare and water reflected sphere configurations. These calculations yield an impact on the estimated critical mass as a function of 235 U loading density with maximum differences as large as 1% - 5% for over-moderated thermal spectrum systems. Consequently, the NNL TSL evaluations are anticipated to have a small impact on criticality calculations of thermal reactor systems regardless of the material phase. Nevertheless, characteristic differences exist in the predicted thermal spectra as function of energy for the two sets of TSL evaluations, which are attributed to difference in the underlying phonon density of states of hydrogen bound in ZrH x .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimization of Binning Parameters in the Feynman Variance-to-Mean Method for Delayed Neutron Reinterrogation

The focus of this work is to determine the optimal input parameters for analyzing active interrogation data that utilizes the physics of the delayed neutron re-interrogation technique. This work compares the signature from an active neutron measurement of a highly enriched uranium (HEU) system to an active background measurement (i.e., without the HEU item in place). The item being measured represents a 21.8 kg metal sphere of HEU (93 weight percent) assembled from a subset of the Rocky Flats (RF) uranium hemishells. The detection system consisted of two NoMAD neutron multiplicity detectors, a SNAP III neutron detector, and a Thermo Fisher P211 pulsed 14 MeV neutron source. In addition, varying analyses of the NoMAD list-mode detector data are performed to determine whether it is preferential to use a particular analysis bin size for producing Feynman histograms, selection of pulses to prevent discrepancies from buildup, or window of time during the pulsed neutron interrogation. This work is still currently ongoing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗