Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Preliminary Sensorimotor and Cardiovascular Results from the Joint Russian/U.S. Pilot Field Test in Preparation for the Full Field Test

Ongoing collaborative research efforts between NASA's Neuroscience and Cardiovascular Laboratories, and the Institute of Biomedical Problems' (IBMP) Sensory-Motor and Countermeasures Laboratories have been measuring functional sensorimotor, cardiovascular and strength responses following bed rest, dry immersion, short-duration (Space Shuttle) and long-duration (Mir and International Space Station [ISS]) space flights. While the unloading paradigms associated with dry immersion and bed rest does serve as acceptable flight analogs, testing of crew responses following the long-duration flights previously has not been possible until a minimum of 24 hours after landing. As a result, it is not possible to estimate the nonlinear trend of the early (<24 hours) recovery process nor is it possible to accurately assess the full impact of the decrements associated with long-duration flight. To overcome these limitations, both the Russian and U.S. programs have implemented testing at the landing site. By joint agreement, this research effort has been identified as the functional Field Test (FT). For practical reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The primary goal of this research is to determine functional abilities in long-duration space-flight crews beginning as soon after landing as possible (< 2 hours) with one to three immediate follow-up measurements on the day of landing. This goal has both sensorimotor and cardiovascular elements, including evaluations of NASA's new anti-orthostatic compression garment and the Russian Kentavr garment. Functional sensorimotor measurements will include, but are not limited to, assessing hand/eye coordination, egressing from a seated position, walking normally without falling, measuring of dynamic visual acuity, discriminating different forces generated with both the hands and legs, recovering from a fall, coordinated walking involving tandem heel-to-toe placement, and determining postural ataxia while standing. The cardiovascular portion of the investigation includes measuring blood pressure and heart rate during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during the other functional tasks. In addition to the immediate post-landing collection of data for the full FT, postflight data will be acquired between one and three more other times within the 24 hours after landing and will continue over the subsequent weeks until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a single trial run comprised of a jointly agreed upon subset of tests from the full FT and relies heavily on IBMP's Sensory-Motor and Countermeasures Laboratories for content and implementation. The PFT has been collected on several ISS missions. Testing included: (1) a sit-to-stand test, (2) recovery from a fall where the crewmember began in the prone position on the ground and then stood for 3 minutes while cardiovascular stability was determined and postural ataxia data were acquired, and (3) a tandem heel-totoe walk test to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from body-worn inertial sensors, and severity of postflight motion sickness were collected for each test session. In summary, the level of functional deficit is expected to be most profound during the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Clearly measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiologic data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiologic measurements will allow estimation of nonlinear sensorimotor and cardiovascular recovery trends that has not been previously captured in over 50 years of space flight.

Reschke, M. F.↗

Functional Sensory-Motor Performance Following Long Term Space Flight: The First Results of "Field Test" Experiment

The effect that extended-duration space flights may have on human space travelers, including exploration missions, is widely discussed at the present time. Specifically, there is an increasing amount of evidence showing that the physical capacity of cosmonauts is significantly reduced after long-duration space flights. It is evident that the most impaired functions are those that rely on gravity, particularly up right posture and gait. Because of the sensorimotor disturbances manifested in the neurology of the posture and gait space flight and postflight changes may also be observed in debilitating motion sickness. While the severity of particular symptoms varies, disturbances in spatial orientation and alterations in the accuracy of voluntary movements are persistently observed after long-duration space flights. At this time most of the currently available data are primarily descriptive and not yet suitable for predicting operational impacts of most sensorimotor decrements observed upon landing on planetary surfaces or asteroids. In particular there are no existing data on the recovery dynamics or functionality of neurological, cardiovascular or muscle performance making it difficult to model or simulate the cosmonauts' activity after landing and develop the appropriate countermeasure that will ensure the rapid and safe recovery of crewmembers immediately after landing in what could be hostile environments. However and as a starting position, the videos we have acquired during recent data collection following the long duration flights of cosmonauts and astronauts walking and performing other tasks shortly after return from space flight speak volumes about their level of deconditioning. A joint Russian-American team has developed a new study specifically to address the changes in crewmembers performance and the recovery of performance with the intent of filling the missing data gaps. The first (pilot) phase of this study includes recording body kinematics and quantifying the coordination and timing of relatively simple basic movements - transition from seated and prone positions to standing, walking, stepping over obstacles, tandem walking, muscle compliance, as well as characteristics of postural sway and orthostatic tolerance. Testing for changes in these parameters have been initiated in the medical tent at the landing site. The first set of experiments showed that during the first hour after landing, cosmonauts and astronauts were able to execute (although slower and with more effort than preflight) simple movements such as egress from a seated or prone position and also to remain standing for 3.5 minutes without exhibiting pronounced cardiovascular changes. More challenging tests, however, demonstrated a prominent reduction in coordination - the obstacle task, for example, was performed at much slower speed and with a marked overestimation of the obstacle height and tandem walking was greatly degraded suggesting significant changes in proprioception, brainstem and vestibular function. There is some speculation that the neural changes, either from the bottom-up or top down may be long lasting; requiring compensatory responses that will modify or mask the adverse responses we have observed. Furthermore, these compensatory responses may actually be beneficial, helping achieve a more rapid adaptation to both weightlessness and a return to earth.

Tomilovskaya, E. S.↗

Pilot Sensorimotor and Cardiovascular Results from the Joint Russian/U.S. Field Test

The primary goal of this research is to determine functional abilities associated with long-duration space flight crews beginning as soon after landing as possible (< 2 hours) with an additional two follow-up measurements sessions on the day of landing. This goal has both sensorimotor and cardiovascular elements, including evaluations of NASA's new anti-orthostatic compression garment and the Russian Kentavr garment. Functional sensorimotor measurements will include, but are not limited to, assessing hand/eye coordination, standing from a seated position (sit-to-stand), walking normally without falling, measurement of dynamic visual acuity, discriminating different forces generated with both the hands and legs, recovering from a fall (standing from a prone position), coordinated walking involving tandem heel-to-toe placement, and determining postural ataxia while standing. The cardiovascular portion of the investigation includes measuring blood pressure and heart rate during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during the other functional tasks. In addition to the immediate post-landing collection of data for the full FT, postflight data is being acquired twice more within the 24 hours after landing and will continue over the subsequent weeks until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a initial evaluation of the feasibility of testing in the field, and is comprised of a jointly agreed upon subset of tests from the full FT and relies heavily on Russia's Institute of Biomedical Problems Sensory-Motor and Countermeasures Laboratories for content and implementation. The PFT has been collected on several ISS missions. Testing on the U.S. side has included: (1) a sit-to-stand test, (2) recovery from a fall where the crewmember began in the prone position on the ground and then stood for 3 minutes while cardiovascular stability was determined and postural ataxia data were acquired, and (3) a tandem heel-to-toe walk test to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from bodyworn inertial sensors, and severity of postflight motion sickness were collected during each test session. Our Russian investigators have added measurements associated with: (a) obstacle avoidance, (b) muscle compliance and (c) postural adjustments to perturbations (push) applied to the subject's chest area. The level of functional deficit observed in the crew tested to date is typically beyond what was expected and is clearly triggered by the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Clearly measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiologic data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiologic measurements will allow the estimation of nonlinear sensorimotor and cardiovascular recovery trends that have not been previously captured

Reschke, M. F.↗

Quantification of In-flight Physical Changes: Anthropometry and Neutral Body Posture

Currently, NASA does not have sufficient in-flight anthropometric data gathered to assess the impact of physical body shape and size changes on suit sizing. For developing future planetary and reduced gravity suits, NASA needs to quantify the impacts of microgravity on anthropometry, body posture, and neutral body postures (NBP) to ensure optimal crew performance, fit, and comfort. To obtain these impacts, anthropometric data, circumference, length, height, breadth, and depth for body segments (i.e. chest, waist, bicep, thigh, calf) from astronauts for pre, in-, and postflight conditions needs to be collected. Once this data has been collected, a comparison between pre, in-, and postflight anthropometric values will be analyzed, yielding microgravity factors. The NBP will be used to determined body posture (joint angle) changes between subjects throughout the duration of a mission. Data collection, starting with Increments 37/38, is still in progress with the completion of 3 out of 12 subjects. NASA suit engineers and NASA's Extravehicular Activity (EVA) Project Office have identified that suit fit in microgravity could become an issue. It has been noted that crewmembers often need to adjust their suit sizing once they are in orbit. This adjustment could be due to microgravity effects on anthropometry and postural changes, and is necessary to ensure optimal crew performance, fit, and comfort in space. To date, the only data collected to determine the effects of microgravity on physical human changes have been during Skylab, STS-57, and a recent HRP study on seated height changes due to spinal elongation (Spinal Elongation, Master Task List [MTL] #221). The Skylab and the STS-57 studies found that there is a distinct neutral body posture (NBP) based on photographs. The still photographs showed that there is a distinguishable posture with the arms raised and the shoulder abducted; and, in addition, the knees were flexed with noticeable hip flexion and the foot plantar flexed [1,2]. This is the one standard set of body joint angles for a NBP in microgravity. A recent simulated microgravity NBP study [3] has shown an individual variability and inconsistencies in defining NBP. This variation may be influenced by spinal growth, the type of suit fit, and other potential anthropometry factors such as spinal curvature, age, and gender. The variation aspect of this essential data is required for all kinds of space device designs (e.g. suits, habitat, mobility aids, etc.). The method proposed considers the dynamic nature of body movement and will use a measurement technique to continually monitor posture and develop a probability likelihood of the natural posture and how the NBP postures are affected by anthropometry. Additionally, Skylab studies found that crewmembers experienced a stature growth of up to 3%. The data included 3 crewmembers that showed that there is a bi-phasic stature growth once the crew enters into weightlessness. However, the Spinal Elongation study identified that the crewmembers could experience about a 6% growth in seated height and a 3% stature growth, when exposed to microgravity. The results prove that not all anthropometric measurements have the same microgravity percent growth factor. For EVA and suit engineers to properly update the sizing protocol for microgravity, they need additional anthropometric data from space missions. Hence, this study is aimed to gather additional in-flight anthropometric measurements, such as length, depth, breadth, and circumference, to determine the changes to body shape and size due to microgravity effects. It is anticipated that by recording the potential changes to body shape and size, a better suit sizing protocol will be developed for ISS and other space missions. In essence, this study will help NASA quantify the impacts of microgravity on anthropometry to ensure optimal crew performance, fit, and comfort. This study will use simplistic data collection techniques, 3D laser scanning, digital still, and video data, and perform photogrammetric analyses to determine the changes that occur to the body shape, size, and NBP when exposed to a microgravity environment.

Young, K. S.↗

Validation of the 5th and 95th Percentile Hybrid III Anthropomorphic Test Device Finite Element Model

NASA spacecraft design requirements for occupant protection are a combination of the Brinkley criteria and injury metrics extracted from anthropomorphic test devices (ATD's). For the ATD injury metrics, the requirements specify the use of the 5th percentile female Hybrid III and the 95th percentile male Hybrid III. Furthermore, each of these ATD's is required to be fitted with an articulating pelvis and a straight spine. The articulating pelvis is necessary for the ATD to fit into spacecraft seats, while the straight spine is required as injury metrics for vertical accelerations are better defined for this configuration. The requirements require that physical testing be performed with both ATD's to demonstrate compliance. Before compliance testing can be conducted, extensive modeling and simulation are required to determine appropriate test conditions, simulate conditions not feasible for testing, and assess design features to better ensure compliance testing is successful. While finite element (FE) models are currently available for many of the physical ATD's, currently there are no complete models for either the 5th percentile female or the 95th percentile male Hybrid III with a straight spine and articulating pelvis. The purpose of this work is to assess the accuracy of the existing Livermore Software Technology Corporation's FE models of the 5th and 95th percentile ATD's. To perform this assessment, a series of tests will be performed at Wright Patterson Air Force Research Lab using their horizontal impact accelerator sled test facility. The ATD's will be placed in the Orion seat with a modified-advanced-crew-escape-system (MACES) pressure suit and helmet, and driven with loadings similar to what is expected for the actual Orion vehicle during landing, launch abort, and chute deployment. Test data will be compared to analytical predictions and modelling uncertainty factors will be determined for each injury metric. Additionally, the test data will be used to further improve the FE model, particularly in the areas of the ATD neck components, harness, and suit and helmet effects.

Lawrence, C.↗

Initial Sensorimotor and Cardiovascular Data Acquired from Soyuz Landings: Establishing a Functional Performance Recovery Time Constant

INTRODUCTION Testing of crew responses following long-duration flights has not been previously possible until a minimum of more than 24 hours after landing. As a result, it has not been possible to determine the trend of the early recovery process, nor has it been possible to accurately assess the full impact of the decrements associated with long-duration flight. To overcome these limitations, both the Russian and U.S. programs have implemented joint testing at the Soyuz landing site. This International Space Station research effort has been identified as the functional Field Test, and represents data collect on NASA, Russian, European Space Agency, and Japanese Aerospace Exploration Agency crews. RESEARCH The primary goal of this research is to determine functional abilities associated with long-duration space flight crews beginning as soon after landing as possible on the day of landing (typically within 1 to 1.5 hours). This goal has both sensorimotor and cardiovascular elements. To date, a total of 15 subjects have participated in a 'pilot' version of the full 'field test'. The full version of the 'field test' will assess functional sensorimotor measurements included hand/eye coordination, standing from a seated position (sit-to-stand), walking normally without falling, measurement of dynamic visual acuity, discriminating different forces generated with the hands (both strength and ability to judge just noticeable differences of force), standing from a prone position, coordinated walking involving tandem heel-to-toe placement (tested with eyes both closed and open), walking normally while avoiding obstacles of differing heights, and determining postural ataxia while standing (measurement of quiet stance). Sensorimotor performance has been obtained using video records, and data from body worn inertial sensors. The cardiovascular portion of the investigation has measured blood pressure and heart rate during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during sensorimotor testing on all of the above measures. We have also collected motion sickness data associated with each of the postflight tests. When possible rudimentary cerebellar assessment was undertaken. In addition to the immediate post-landing collection of data, postflight data has been acquired twice more within 24 hours after landing and measurements continue until sensorimotor and cardiovascular responses have returned to preflight normative values (approximately 60 days postflight). SUMMARY The level of functional deficit observed in the crew tested to date is more severe than expected, clearly triggered by the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiologic data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiologic measurements will allow the estimation of nonlinear sensorimotor and cardiovascular recovery trends that have not been previously captured.

Reschke, M. F.↗

Quantification of ln-Flight Physical Changes: Anthropometry and Neutral Body Posture

Currently, NASA does not have sufficient in-flight anthropometric data to assess the impact of changes in body shape and size. For developing future planetary and reduced-gravity suits, NASA needs to quantify the impacts of microgravity on anthropometry and body posture to ensure optimal crew performance, fit, and comfort. To obtain data on these changes, circumference, length, height, breadth, and depth for body segments (chest, waist, bicep, thigh, calf) from astronauts for preflight, in-flight, and post-flight conditions needs to be collected. Once these data have been collected, pre-flight, in-flight, and post-flight anthropometric values will be compared, yielding microgravity factors. The neutral body posture (NBP) will also be measured, to determine body posture (joint angle) changes between subjects throughout the duration of a mission. Data collection, starting with Increments 37/38, is still in progress but has been completed for 6 out of 9 subjects. NASA suit engineers and NASA's Extravehicular Activity (EVA) Project Office have identified that suit fit in microgravity could become an issue. It has been noted that crewmembers often need to adjust their suit sizing once they are in orbit. This adjustment could be due to microgravity effects on anthropometry and postural changes, and is necessary to ensure optimal crew performance, fit, and comfort in space. To date, the only data collected to determine the effects of microgravity on physical human changes were collected during Skylab 4, the Apollo-Soyuz Test Project (ASTP), Space Shuttle mission STS-57, and a recent HRP study on seated height changes due to spinal elongation (Spinal Elongation, Master Task List [MTL] #221). The Skylab 4, ASTP, and the STS-57 studies found that, according to photographs, a distinct NBP exists. The still photographs showed a distinguishable posture with the arms raised and the shoulders abducted; in addition, the knees are flexed, with noticeable hip flexion, and the foot is plantar flexed [1,2]. This combination is considered to be the standard set of body joint angles for an NBP in microgravity. A recent simulated microgravity NBP study [3] showed individual variability and inconsistencies in defining NBP. This variation may be influenced by spinal growth, and other potential anthropometry factors such as spinal curvature, age, and gender. Data on the variation of this posture data is required for all kinds of space device designs (such as suits, habitat, and mobility aids). The method proposed in this study considers the dynamic nature of body movement and will use a measurement technique to continually monitor posture and develop a probability likelihood of the neutral posture and how the NBP postures are affected by anthropometry. Additionally, Skylab studies found that crewmembers experienced a stature growth of up to 3 percent. The data included 3 crewmembers and showed that a biphasic stature growth occurs once the crewmember enters into weightlessness. However, the HRP Spinal Elongation study showed that crewmembers could experience about a 6 percent growth in seated height and a 3 percent stature growth, when exposed to microgravity. The results of that study prove that not all anthropometric measurements have the same microgravity percent growth factor. For EVA and suit engineers to properly update the sizing protocol for microgravity, they need additional anthropometric data from space missions. Hence, this study is aimed at gathering additional in-flight anthropometric measurements, such as length, depth, breadth, and circumference, to determine the changes to body shape and size caused by microgravity effects. It is anticipated that by recording the potential changes to body shape and size, NASA will develop a better suit sizing protocol for the International Space Station and other space missions. In essence, this study will help NASA quantify the impacts of microgravity on anthropometry to ensure optimal crew performance, fit, and comfort. This study will use standard anthropometry data collection techniques, 3D laser scanning, digital still photography, and video data, and perform photogrammetric analyses to determine the changes that occur to the body shape and size, and to NBP, when the human body is exposed to a microgravity environment.

Young, K. S.↗

Validation of a Cephalad Fluid Shift Countermeasure

INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.

Macias, B.↗

Suited and Unsuited Hybrid III Impact Testing and Finite Element Model Characterization

NASA spacecraft design requirements for occupant protection are a combination of the Brinkley Dynamic Response Criteria and injury assessment reference values (IARV) extracted from anthropomorphic test devices (ATD). For the ATD IARVs, the requirements specify the use of the 5th percentile female Hybrid III and the 95th percentile male Hybrid III. Each of these ATDs is required to be fitted with an articulating pelvis (also known as the aerospace pelvis) and a straight spine. The articulating pelvis is necessary for the ATD to fit into spacecraft seats, while the straight spine is required as injury metrics for vertical accelerations are better defined for this configuration. Sled testing of the Hybrid III 5th Percentile Female Anthropomorphic Test Device (ATD) was performed at Wright-Patterson Air Force Base (WAPFB). Two 5th Percentile ATDs were tested, the Air Force Research Lab (AFRL) and NASA owned Hybrid III ATDs with aerospace pelvises. Testing was also conducted with a NASA-owned 95th Percentile Male Hybrid III with aerospace pelvis at WPAFB. Testing was performed using an Orion seat prototype provided by Johnson Space Center (JSC). A 5-point harness comprised of 2 inch webbing was also provided by JSC. For suited runs, a small and extra-large Advanced Crew Escape System (ACES) suit and helmet were also provided by JSC. Impact vectors were combined frontal/spinal and rear/lateral. Some pure spinal and rear axis testing was also performed for model validation. Peak accelerations ranged between 15 and 20-g. This range was targeted because the ATD responses fell close to the IARV defined in the Human-Systems Integration Requirements (HSIR) document. Rise times varied between 70 and 110 ms to assess differences in ATD responses and model correlation for different impact energies. The purpose of the test series was to evaluate the Hybrid III ATD models in Orion-specific landing orientations both with and without a spacesuit. The results of these tests were used by the NASA Engineering and Safety Center (NESC) to validate the finite element model (FEM) of the Hybrid III 5th Percentile Female ATD. Physical test data was compared to analytical predictions from simulations, and modelling uncertainty factors have been determined for each injury metric. Additionally, the test data has been used to further improve the FEM, particularly in the areas of the ATD preload, harness, and suit and helmet effects.

Lawrence, C.↗

Heart Rate Responses to Unaided Orion Side Hatch Egress in the Neutral Buoyancy Laboratory

NASA is developing the Orion capsule as a vehicle for transporting crewmembers to and from the International Space Station (ISS) and for future human space exploration missions. Orion and other commercial vehicles are designed to splash down in the ocean where nominally support personnel will assist crewmembers in egressing the vehicle. However, off-nominal scenarios will require crewmembers to egress the vehicle unaided, deploy survival equipment, and ingress a life raft. PURPOSE: To determine the heart rate (HR) responses to unaided Orion side hatch egress and raft ingress as a part of the NASA Crew Survival Engineering Team's evaluation of the PORT Orion mockup in the Neutral Buoyancy Laboratory (NBL). METHODS: Nineteen test subjects, including four astronauts (N=19, 14 males/5 females, 38.6+/-8.4 y, 174.4+/-9.6 cm, 75.7+/-13.1 kg), completed a graded maximal test on a cycle ergometer to determine VO2peak and HRpeak and were divided into five crews of four members each; one subject served on two crews. Each crew was required to deploy a life raft, egress the Orion vehicle from the side hatch, and ingress the life raft with two 8 kg emergency packs per crew. Each crew performed this activity one to three times; a total of ten full egresses were completed. Subjects wore a suit that was similar in form, mass, and function to the Modified Advanced Crew Escape Suit (MACES) including helmet, gloves, boots, supplemental O2 bottles, and a CO2-inflated life preserver (approx.18 kg); subjects began each trial seated supine in the PORT Orion mockup with seat belts and mockup O2 and communication connections and ended each trial with all four crewmembers inside the life raft. RESULTS: VO2peak was 40.8+/-6.8 mL/kg/min (3.1+/-0.7 L/min); HRpeak was 181+/-10 bpm. Total egress time across trials was 5.0+/-1.6 min (range: 2.8-8.0 min); all subjects were able to successfully complete all trials. Average maximum HR at activity start, at the hatch opening, in the water, and in the raft, was 108, 137, 147, and 153 bpm, respectively; these values corresponded to 59+/-10%, 73+/-8%, 82+/-3%, and 84+/-6% of HRpeak, respectively. The highest HRs were seen after raft ingress and ranged from 72-99% HRpeak. Across all trials, cumulative averages of 5.4, 3.0, 1.1, and 0.2 min were spent at HRs >60%, >70%, >80%, and >90% HRpeak, respectively. CONCLUSION: Unaided Orion side hatch egress in the NBL is a relatively short-duration activity that elicits a high HR response for several min. Although all crewmembers successfully completed this activity, additional factors such as high seas, poor visibility, an incapacitated crewmember, neurovestibular perturbation, and neuromuscular deconditioning characteristic of a true operational environment may increase the physiologic demand (or decrease crewmembers' physiologic capacity) of unaided Orion side hatch egress. Additionally, landing conditions may require the crewmembers to egress from the top hatch, which is expected to be even more physiologically demanding; this condition will be evaluated in subsequent collaborative testing with the NASA Crew Survival Engineering Team.

English, Kirk L.↗

Validation of a Manually Oscillating Chair for In-The-Field Assessment of Dynamic Visual Acuity on Crewmembers Within Hours of Returning From Long-Duration Spaceflight

Long-duration spaceflight results in sensorimotor adaptations, which cause functional deficits during gravitational transitions, such as landing on a planetary surface after long-duration microgravity exposure. Both the vestibular system and the central nervous system are affected by gravitational transitions. These systems are responsible for coordinating head and eye movements via the vestibulo-ocular reflex (VOR) and go through an adaptation period upon exposure to microgravity. Consequently, they must also re-adapt to Earth's gravitational environment upon landing. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with crewmembers reporting oscillopsia and blurred vision caused by retinal slip, or the inability to keep an image focused on their retina. This is thought to drive motion sickness symptoms experienced by most crewmembers following landing. Retinal slip can be estimated by dynamic visual acuity (DVA); visual acuity while in motion. Previously, DVA has been assessed in the laboratory where subjects walked at 6.4 km/hr on a motorized treadmill. Using this method, Peters et al. (2011) found that DVA is worsened in astronauts by an average of 0.75 eye-chart lines one day after landing. However, it is believed that re-adaptation occurs quickly and that DVA might be worse immediately upon re-exposure to a gravitational environment. Since many crewmembers are unable to walk safely upon landing, it was necessary to develop a method for replicating the vertical head movements associated with walking. In addition, the use of a chair to imitate the head displacement caused by walking isolates eye-head interactions without allowing for trunk and lower-body compensation, as seen with treadmill walking (Mulavara & Bloomberg 2003). Therefore, a modality for assessing DVA in the field within a few hours of landing was developed. In this study, we validated the ability of a manually operated oscillating chair to reproduce the oscillatory frequency of walking on a treadmill. Healthy non-astronaut subjects (n=14) participated in one test session and completed three static (seated) and three dynamic (walking/oscillated) visual acuity tests. DVA was assessed using a motorized treadmill, an automated oscillating chair, and a manually operated chair, both developed in the Neuroscience Laboratory at JSC. The automated chair was motor-driven and set to oscillate vertically at 2 Hz with a vertical displacement of +/- 5 cm to simulate vertical translation while walking. The manually operated chair was oscillated vertically by a test operator to the beat of a metronome at 120 beats/min (2 Hz) and a vertical displacement of approximately +/- 5 cm. As the subject was oscillated, they were asked to discern the direction gap of Landolt-C optotypes of varying sizes and verbally reported the direction while an operator recorded their response using a gamepad. Subjects were outfitted with accelerometers (sampling rate = 128 Hz) on their head, trunk and lumbar spine. A fast Fourier transform was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. The spread of the frequency distribution for the manual chair was not significantly different from either the treadmill or the automated chair. However, all three conditions had similar non-zero standard error values, suggesting a variance in head movement frequency which may affect DVA. The average oscillation frequency of the manual chair (1.85 Hz) was significantly different (α=0.05) from that of treadmill walking (2.24 Hz), but not significantly different from that of the automated chair (1.85 Hz) and all three conditions had small standard errors (SEM = 0.04, 0.06, and 0.08 Hz for manual, treadmill, and automated respectively). This implies that both chairs oscillate at a frequency below that of treadmill walking, but are comparable to each other and reproducible across sessions. Additionally, DVA scores did not vary significantly across conditions. The smaller spread values of the oscillating chairs' frequencies indicated mitigation of variation induced by locomotor strategies, which enables better examination of the issue of VOR adaptation. Furthermore, due to the deconditioned state of crewmembers in the initial hours after landing, it is easier to transport a manual bouncing chair into the field and safer to perform a vision test while seated in a chair versus walking on a treadmill. Therefore, the manually oscillating chair has been deemed to meet and exceed the DVA testing capabilities previously obtained by treadmill walking.

Kreutzberg, G. A.↗

Full-Scale Drop Test of a Fokker F28 Wingbox Fuselage Section

During the summer of 2017, a vertical drop test was conducted on a partial section of a Fokker F28 MK4000 aircraft as a part of a joint NASA/FAA effort to investigate the performance of transport category aircraft under realistic crash conditions. Ten Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) ranging from 5th to 95th percentile sizes were used for the collection and comparison of occupant loads. Additionally, overhead bin mass simulators were added to achieve a realistic fuselage configuration. The section was dropped with a downward facing pitch angle onto a sloping soil surface in order to simulate a local horizontal velocity in the airframe. Instrumentation consisting of accelerometers was installed to measure floor, seat track, ATD, and overhead bin acceleration responses. Self-contained data recorders logging accelerations and rotational rates were also used on the seat tracks and lower structure as evaluations for crash recording devices in potential future use cases. The right side of the section was painted with a stochastic black and white speckle pattern for use in full field photogrammetric imaging techniques. Results collected from the airframe accelerometers will be presented, and deformation and failures of the test article structure will be discussed. Finally, an examination of the test article motion will be presented using derived components of local velocities with their effect on the impact acceleration and airframe response.

Littell, J. D.↗

Simulation of a Full-Scale Crash Test of a Fokker F28 Fellowship Aircraft

In June 2019, a full-scale crash test of a Fokker F28 Fellowship aircraft was conducted as part of a joint National Aeronautics and Space Administration/Federal Aviation Administration (NASA/FAA) project to investigate the performance of transport aircraft under realistic crash conditions. The test objectives were to provide data for assessment of transport aircraft crash worthiness and to generate test data for model validation. The test article was loaded with transport aircraft seats in a 3+2 configuration. A total of 24 instrumented Anthropomorphic Test Devices (ATDs) were placed in the seats and restrained. The test article weighed 33,306-lb. and, during the crash test, impacted a 2-ft. high soil bed at 65.3-ft/s forward and 31.8-ft/s vertical velocity. The full-scale crash test was simulated using the commercial nonlinear explicit transient dynamic finite element code, LSDYNA®. This paper will provide a description of the test article and the crash test conditions, document the F28 full-scale model development, and present test-analysis comparisons in several categories including inertial properties, kinematic responses, structural acceleration responses, and airframe deformation and failure. In addition, test-analysis results will be quantified based on the International Organization for Standardization (ISO) 16250 curve comparison methodology.

Jackson, Karen E.↗

TPSAS-NF1676L-32920-DND

In June 2019, a full-scale crash test of a Fokker F28 Fellowship aircraft will be conducted at NASA Langley Research Center?s Landing and Impact Research (LandIR) Facility. The F28 is a high-performance twin-turbo fan narrow-body aircraft with seating in a 3+2 configuration. The MK4000 variant, used in this test, is capable of carrying up to 85 passengers on medium range routes. The F28 was first type certified by the Federal Aviation Administration (FAA) in 1969 and now the majority of the F28 fleet has retired from service in the United States. In 2016, the FAA and NASA Langley Research Center (LaRC) signed an interagency agreement for conducting a research program to obtain test data that will support the development of airframe level crash requirements for transport category airplanes [1]. The objectives of the full-scale crash test can be divided into six categories: (1) To compare and contrast responses in identical aircraft undergoing vertical only to combined vertical and horizontal loading conditions, (2) To examine the effects of horizontal loading on aircraft structure during a crash event, (3) To generate data for the use in calibration of computer modelling efforts, (4) To generate data from onboard Anthropomorphic Test Devices (ATDs) for the evaluation of injury, (5) To obtain data from experimental seats, and (6) To obtain data from new and novel ATD designs including Warrior Injury Assessment MANikin (WIAMan) [2], Test device for Human Occupant Response (THOR), and other newly developed child ATDs. The focus of this presentation will be to document finite element model development of the full-scale F28 aircraft and to present preliminary test-analysis predictions. NASA obtained the full-scale F28 aircraft, plus three fuselage sections and two sets of wings with funding through the NASA Aviation Safety Program in 1998. In addition to the hardware, NASA purchased a full NASTRAN model of the airframe that had been developed by the Dutch manufacturer, Fokker. Beginning in 2016, the NASTRAN model was converted to LS-DYNA? [4, 5] format and modified by combining parts, adding missing parts of internal structure, and including ballast for loading weights, etc. It contains: 89,223 nodes; 24,065 beam elements; 55,404 shell elements; 29,044 solid elements; 740 parts; 80 material definitions; and, 46 Constrained Nodal Rigid Bodies (CNRBs). The aircraft model will be executed in LSDYNA to simulate the test article impact onto a 2-ft.-high bed of soil under combined velocity conditions of 70-ft/s forward and 30-ft/s vertical velocity. Pre-test simulation predictions will be generated and correlated with test data.

Karen E Jackson↗

Development of a Full-Scale Finite Element Model of the Fokker F28 Fellowship Aircraft and Crash Simulation Predictions

In June 2019, a full-scale crash test of a Fokker F28 Fellowship aircraft was conducted as part of a joint National Aeronautics and Space Administration/Federal Aviation Administration (NASA/FAA) project to investigate the performance of transport aircraft under realistic crash conditions. The test objectives were to provide data for assessment of transport aircraft crashworthiness under realistic impact conditions and to generate test data for model validation. The test article was loaded with transport aircraft seats in a 3+2 configuration. A total of 24 instrumented ATDs were placed in the seats and restrained. The test article weighed 33,306-lb. (15,107.3-kg) and, during the crash test, impacted a 2-ft. (0.61-m) high soil bed at 65.3-ft/s (19.9-m/s) forward and 31.8-ft/s (9.7-m/s) vertical velocity. The full-scale aircraft crash test was simulated using the commercial nonlinear explicit transient dynamic finite element code, LS-DYNA. This paper will provide a description of the test article and the crash test conditions, document the F28 full-scale model development, and present test-analysis comparisons. The test-analysis comparisons include inertial properties, kinematic responses, structural acceleration responses, and structural deformation and failure.

Karen E Jackson↗

Lower neck injury criteria for THOR and Hybrid III dummies in rear impact

The objectives of the study are to derive lower-neck-injury probability curves under rear impact loading from matched pair Hybrid III and THOR dummy tests. Methods: Twelve whole-body and 15 isolated head-neck rear-impact sled tests were conducted using the 2 dummies. They were positioned on a rigid seat that was attached to an acceleration sled. The dummies were positioned with the head parallel to the ground, torso against the seat back, and legs stretched such that there was no axial rotation. The acceleration pulse matched the previous in-house human cadaver tests. The 6-axis lower-neck load cell was used in both dummies. For the isolated rear-impact tests,the head-neck was excised from the dummies, and the lower-neck load cell was mounted to the top of the sled with the head parallel to the ground and such that the acceleration vector was in the rear impact mode. Lower-neck loads and lower-neck-injury criteria (LNij) were obtained using the load cell data and survival analysis to develop injury-assessment-risk values and curves for both dummies. The LNij criteria were determined for both dummies using the intercept value corresponding to the 90% probability level for the forces and moments. Results: The log normal and Weibull distributions were the optimal distributions for the Hybrid III and THOR devices. At the 50% risk level, the mean LNij of 1.1 and NCIS was 0.77 for the Hybrid III, and 1.5 NCIS was 0.30 for the THOR device. The quality indices were in the fair range and good range for the 2 dummies, respectively, at this risk level. Conclusions: The lower-neck-based IARCs and IARVs serve as the first dataset for injury assessments, and the THOR may be a better test device for assessing injures in rear impact environments.

Narayan Yoganandan↗

Electrodynamic Dust Shield Housing for RASSOR Redesign and Fabrication

Abstract—An Electrodynamic Dust Shield (EDS) was to be mounted over the cameras of the Regolith Advanced Surface Systems Operations Robot (RASSOR) to mitigate the clouding effects and abrasive properties of lunar dust. This report discusses the redesign process and physical fabrication of the housing unit planned to attach the EDS to the RASSOR camera. The two-piece 3D-Printed design consists of a holder and cover unit. The EDS Holder seats the EDS near two live copper contacts that are to be wired into the main electronics housing. The EDS Cover seats two metal leaf spring tabs to bridge the connections between the copper contacts and EDS electrodes, as well as a centralized O-ring that is pressed flush against the EDS to mitigate dust intrusion. All components were modeled, printed, and checked for proper electrical contact and mechanical fit. The built-up assembly was subsequently tested in the Electrostatics and Surface Physics Laboratory (ESPL) and demonstrated good dust clearing performance.

Alexander Lacerna↗

Motion Sickness and Concerns for Urban Air Mobility Vehicles: A Literature Review

Motion sickness is a general term for a constellation of signs and symptoms, generally due to exposure to abrupt, periodic, or unnatural accelerations, especially when traveling in a vehicle. Motion sickness results from a mismatch of the visual and nonvisual (vestibular and kinesthetic) information, the observed scene and the motion felt or lack of it. Motion sickness onset is associated with a pattern of physiological changes in heart rate, peripheral blood flow, respiration, and skin conductance and the pattern is repeatable for a particular subject but variable between subjects. Demographic factors such as gender and age that affect motion sickness are well known with children, women, and older adults more likely to be susceptible. Often motion sickness is assessed and quantified using variations of the motion sickness susceptibility questionnaires including the Pensacola Diagnostic Rating Scale and the Simulator Sickness Questionnaire. Even though symptoms are easily identified by such questionnaires, they commonly are subjective. Tools such as these questionnaires for screening individuals susceptible to motion sickness are useful, however, they are only mildly predictive. Moreover, models for predicting motion sickness, which have largely been developed for sea sickness, do not consider task characteristics. Predictions of motion sickness rates and prevalence for Urban Air Mobility (UAM) vehicles are not possible at present because data from actual flight or full-fidelity simulation are simply not yet available. Extrapolation from other modes of transportation (i.e., automobiles, buses, trains, boats, other types of aircraft) is difficult because of differences in the motion stimulus experienced, trip duration, and other factors. How UAM vehicles will change the social dynamics of passenger interaction and vehicle interior design changes (e.g., seat orientations) is unknown. Should motion sickness prove to be an issue, vehicle design modifications such as having passengers face forward, providing additional seat recline, giving each person their own climate control for airflow, perhaps ensuring the horizon is visible to all passengers (reducing visual occlusion by the headrest) and visually stabilizing displays on carry-on devices (smart phones, tablets, etc.) may benefit passengers. Several commercial companies provide wearable devices for physiological monitoring that have been validated and are suitable for use with passengers in UAM vehicles or high-fidelity simulators. Potential countermeasures for motion sickness include user-worn devices, anti-motion sickness medications, and non-pharmacological approaches such as biofeedback and Autogenic Feedback Training Exercise. Both simulator and in-vehicle UAM research is needed to evaluate the effectiveness of any potential countermeasure.

motion sickness↗