Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Using handheld plastic scintillator detectors to triage individuals exposed to a radiological dispersal device

After a radiological dispersal device (RDD) event, people could become internally contaminated by inhaling dispersed radioactive particles. A rapid method to screen individuals who are internally contaminated is desirable. Such initial screening can help in prompt identification of those who are highly contaminated and in prioritizing individuals for further and more definitive evaluation such as laboratory testing. The use of handheld plastic scintillators to rapidly screen those exposed to an RDD with gamma-emitting radionuclides was investigated in this study. The Monte Carlo N-Particle transport code was used to model two commercially available plastic scintillation detectors in conjunction with anthropomorphic phantom models to determine the detector response to inhaled radionuclides. Biokinetic models were used to simulate an inhaled radionuclide and its progression through the anthropomorphic phantoms up to 30 d after intake. The objective of the study was to see if internal contamination levels equivalent to 250 mSv committed effective dose equivalent could be detected using these instruments. Five radionuclides were examined: {sup 60}Co, {sup 137}Cs, {sup 192}Ir, {sup 131}I and {sup 241}Am. The results demonstrate that all of the radionuclides except {sup 241}Am could be detected when placing either one of the two plastic scintillator detector systems on the posterior right torso of the contaminated individuals.

61 RADIATION PROTECTION AND DOSIMETRY↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with 3.2% resolution. RSL completed a crystal assessment, and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function, were calculated. Specifically, we report excellent linearity with the aliovalently calcium-doped CeBr3 crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred during doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal and assessed benchmark spectroscopy measurements. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallite. We obtain 4.5% for the packaged crystallite. More spectra are presented for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The National Security Technologies, LLC, Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with a FWHM resolution of 3.2% at the 137Cs 662 keV gamma energy. RSL completed a crystal assessment and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using the DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function of photons per unit energy, were calculated. Specifically, we report excellent linearity with the aliovalent CeBr3:Ca2+ crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is the key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred by doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal as well as the assessment of benchmarking spectroscopy. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallites with diameters <1 cm. We obtain 3.2% before packing the crystallite in a sealed detector container and 4.5% for the packaged crystallite. More spectra were obtained for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

aliovalent substitution↗

An apparatus and method for directly measuring the depth-dependent gain and spatial resolution of turbid scintillators

Turbid (powder or columnar–structured) scintillators are widely used in indirect flat panel detectors (I–FPDs) for scientific, industrial, and medical radiography. Light diffusion and absorption within these scintillators is expected to cause depth–dependent variations in their x ray conversion gain and spatial blur. Furthermore, these variations degrade the detective quantum efficiency of I–FPDs at all spatial frequencies. Despite their importance, there are currently no established methods for directly measuring scintillator depth effects. This work develops the instrumentation and methods to achieve this capability.

47 OTHER INSTRUMENTATION↗

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Investigating new activators for small-bandgap LaX 3 (X = Br, I) scintillators

In this study, luminescence and scintillation properties of Bi 3+ , Sb 3+ , and Eu 2+ -doped LaI 3 and LaBr 3 were explored. Out of the three dopants investigated, Eu 2+ was the most promising new activator for small-bandgap LaX 3 (X = Br, I) and was further studied in the mixed-halide LaBr 3-x I x . Crystals were grown from the melt using the vertical Bridgman method. LaBr 3 :Eu 2+ 0.5% (mol) had the most favorable scintillation properties with a light output of 43,000 ph/MeV and 6% energy resolution at 662 keV. Performance of LaBr 3-x I x :Eu 2+ worsened for most samples as iodide concentration was increased. Finally, room-temperature scintillation of LaI 3 :Eu 2+ 0.1% and 0.5% was observed and is the first case of room-temperature emission reported for doped LaI 3 .

36 MATERIALS SCIENCE↗

Observations regarding inclusions in the growth of $\mathrm{Cs}$ 2 $\mathrm{HfCl}$ 6 single crystal scintillators

Cs 2 HfCl 6 (CHC) is a promising high density, high-Z, non-hygroscopic, and high energy resolution scintillator. In CHC, many crystals have CsCl inclusions that form during growth. In this paper, we investigate how material synthesis, growth rate, and thermal gradient affect the formation of CsCl inclusions and their effect on scintillation performance. First, precursor material was made through a methanol synthesis process both with and without hydrochlorination. Next, five crystals were grown using Bridgman method, at growth rates of 1 or 0.5 mm/h, and thermal gradients of 21 °C or 34 °C per millimeter. The best overall performance was observed in a 22 mm diameter crystal produced using hydrochlorination which was grown at 1 mm/h in a thermal gradient of 34 °C per millimeter. It had a light yield of 36,000 photons/MeV and an energy resolution of 4.0% at 662 keV. Finally, we have also shown that poorer scintillation performance in the lower quality crystals is most likely due to reduced light collection caused by a higher concentration of inclusions.

36 MATERIALS SCIENCE↗

Crystal growth of new high light yield halide perovskite scintillator RbSrI 3

X-ray radiography systems are a key national security technology enabling non-invasive cargo screening. However, the scintillators currently used in these systems have limitations in performance that prompt research for new suitable materials. Here, in this work, crystal growth, physical properties, and optical and scintillation properties of a new halide perovskite scintillator RbSrI 3 were investigated for the first time. The melting point was determined to be 453 °C. Divalent europium and ytterbium were investigated as potential luminescent activators. Light yield and energy resolution of RbSrI 3 :Eu 5 mol% was 78,700 ph/MeV and 2.8 % at 662 keV, and that of RbSrI 3 :Yb 0.5 mol% was 24,000 ph/MeV and 4.9 % at 662 keV.

36 MATERIALS SCIENCE↗

Growth and luminescent properties of scintillators based on the single crystalline films of Lu{sub 3−x}Gd{sub x}Al{sub 5}O{sub 12}:Ce garnet

Highlights: • Single crystalline films of Lu{sub 3−x}Gd{sub x}Al{sub 5}O{sub 12} garnets at x = 0 ÷ 3.0 were grown by LPE method onto YAG substrates. • Lattice constant of Lu{sub 3−}Gd{sub x}Al{sub 5}O{sub 12}:Ce film and the misfit m between films and YAG substrate changed linearly with increasing of Gd content. • Effective Gd{sup 3+}–Ce{sup 3+} energy transfer occurs in the Lu{sub 3−x}Gd{sub x}Al{sub 5}O{sub 12}:Ce films. • Best scintillation light yield is observed in the Lu{sub 3}Al{sub 5}O{sub 12}:Ce and Lu{sub 2.4}Gd{sub 0.6}Al{sub 5}O{sub 12}:Ce films. • Increase of the Gd content in x = 1.5–2.5 range results in decreasing the scintillation LY of Lu{sub 3−x}Gd{sub x}Al{sub 5}O{sub 12}:Ce films. - Abstract: The work is related to the growth of scintillators based on the single crystalline films (SCF) of Ce{sup 3+} doped Lu{sub 3−}Gd{sub x}Al{sub 5}O{sub 12} mixed rare-earth garnets by Liquid Phase Epitaxy (LPE) method. We have shown, that full set of Lu{sub 3−}Gd{sub x}Al{sub 5}O{sub 12} SCFs with x values ranging from 0 to 3.0 can be successfully crystallized by the LPE method onto Y{sub 3}Al{sub 5}O{sub 12} (YAG) substrates from the melt-solutions based on PbO-B{sub 2}O{sub 3} flux. The absorption, X-ray excited luminescence, photoluminescence, thermoluminescence and light yield measurements, the latter under excitation by α-particles of {sup 239}Pu and {sup 241}Am radioisotopes, were applied for their characterization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical and scintillation properties of ScAlMgO{sub 4} crystal grown by the floating zone method

Highlights: • ScAlMgO4 single crystal is synthesized by the floating zone method. • Optical and scintillation properties of the crystal are studied. • The band gap is observed around 200 nm which is consistent with the theoretical work. • The emission appears around 400 nm in photoluminescence and scintillation. - Abstract: The undoped ScAlMgO{sub 4} crystal was synthesized by the Floating Zone (FZ) method, and we evaluated the optical and scintillation properties. The transmittance spectrum showed the absorption edge around 200 nm. VUV-excited emission/excitation spectrum was characterized at a synchrotron facility (UVSOR). Our experiment revealed that the emission was around 400 nm by 200 nm excitation, and the excitation band was 170–210 nm for the latter emission peak. The decay time characterized by 280 nm excitation was 8.3 and 43 ns. Under X-ray irradiation, an emission was observed around 400 nm as for VUV excitation, and the latter decay time constants were 0.23 and 2.2 μs. In addition, the afterglow level at 20 ms after X-ray irradiation was around 0.1% of the intensity during irradiation.

36 MATERIALS SCIENCE↗

Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45 × 10 × 3 mm³ plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. A number of possible design improvements were identified, which should be implemented in a future detector of this type. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-correlation measurements with the EJ-299-33 plastic scintillator

New organic–plastic scintillation compositions have demonstrated pulse-shape discrimination (PSD) of neutrons and gamma rays. We present cross-correlation measurements of 252 Cf and mixed uranium–plutonium oxide (MOX) with the EJ-299-33 plastic scintillator. For comparison, equivalent measurements were performed with an EJ-309 liquid scintillator. Offline, digital PSD was applied to each detector. These measurements show that EJ-299-33 sacrifices a factor of 5 in neutron–neutron efficiency relative to EJ-309, but could still utilize the difference in neutron–neutron efficiency and neutron single-to-double ratio to distinguish 252 Cf from MOX. These measurements were modeled with MCNPX-PoliMi, and MPPost was used to convert the detailed collision history into simulated cross-correlation distributions. MCNPX-PoliMi predicted the measured 252 Cf cross-correlation distribution for EJ-309 to within 10%. Greater photon uncertainty in the MOX sample led to larger discrepancy in the simulated MOX cross-correlation distribution. In conclusion, the modeled EJ-299-33 plastic also gives reasonable agreement with measured cross-correlation distributions, although the MCNPX-PoliMi model appears to under-predict the neutron detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission-fragment detector for DANCE based on thin scintillating films

We report a fission-fragment detector based on thin scintillating films has been built to serve as a trigger/veto detector in neutron-induced fission measurements at DANCE. The fissile material is surrounded by scintillating films providing 4π detection of the fission fragments. The scintillation photons were registered with silicon photomultipliers. A measurement of the 235 U (n,f) reaction with this detector at DANCE revealed a correct time-of-flight spectrum and provided an estimate for the efficiency of the prototype detector of 11.6(7)%. Finally, design and test measurements with the detector are described.

36 MATERIALS SCIENCE↗

Method for measuring multiple scattering corrections between liquid scintillators

In this study, a time-of-flight method is proposed to experimentally quantify the fractions of neutrons scattering between scintillators. An array of scintillators is characterized in terms of crosstalk with this method by measuring a californium source, for different neutron energy thresholds. The spectral information recorded by the scintillators can be used to estimate the fractions of neutrons multiple scattering. With the help of a correction to Feynman's point model theory to account for multiple scattering, these fractions can in turn improve the mass reconstruction of fissile materials under investigation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Applications of C 7 LYC scintillators in fast neutron spectroscopy

Here, the capabilities of 7 Li-enriched Cs 2 7 LiYCl 6 (C 7 LYC) scintillation detectors for fast neutron spectroscopy are explored in benchmark experiments that exploit its excellent pulse-shape discrimination between neutrons and γ rays, and its unprecedented ≈10% energy resolution for fast neutrons in the few MeV range, obtained through the 35 Cl(n,p) reaction. Energy- and angle-resolved elastic and inelastic neutron scattering cross-section measurements of 56 Fe(n,n’) were performed at Los Alamos National Laboratory with a pulsed white neutron source and an array of 1" x 1" C 7 LYC crystals. The results convincingly establish the utility of this dual n/γ scintillator for fast neutron spectroscopy. Intrinsic efficiency measurements of both 1" x 1" and the first ever 3" x 3" C 7 LYC crystal have been initiated, using mono-energetic fast neutron beams at UMass Lowell generated via the 7 Li(p,n) reaction. Finally, the spectroscopic capabilities and potential of C 7 LYC are discussed in the context of developing this emerging scintillator for targeted science applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nature of Moisture-Induced fogging defects in scintillator plastic

Polyvinyl toluene (PVT) scintillator plastic may degrade in the field due to inward water diffusion at elevated temperatures, which exceeds the saturation limit at lower temperatures, and after long periods of time (e.g., many years), leads to the formation of disk-like defects that attenuate scintillation light, leading to detector degradation. In this work, using fractography and high-magnification optical and electron microscopy to characterize the water-induced defects, a model of the fogging process is hypothesized as follows: excess water present at low temperatures diffuses to spheroids to minimize contact with the hydrophobic polymer. Through the hydrophobic effect, the entropy of water increases by forming nanoclusters which minimizes the contact between the water and the PVT. As the water nanoclusters grow, they break and fold the polymer into densely-packed crystalline regions creating more space for water within the spheroids. The polymer outside the spheroid resists the shrinkage which builds up tension within the spheroid. Once the tensile stress exceeds the yield strength of the plastic, the spheroid is torn in half resulting in a defect. Excess water then drains into the cavities along the disk thereby further increasing its entropy. Slower cooling (over 1 day) leads to larger spheroids and hence, larger “permanent” defects. Freezing causes some defects to further grow due to the expansion of water to ice. These findings imply that the remaining lifetime of scintillator plastic in the field could be predicted using temperature and humidity data thereby mitigating security risks of degraded radiation portal monitors.

36 MATERIALS SCIENCE↗

Boron-loaded organic glass scintillators

Herein we report the progress towards an organic glass scintillator with fast and thermal neutron sensitivity providing “triple” pulse shape discrimination (PSD) through the inclusion of a boron-incorporated aromatic molecule. Here, the commercially available molecule 2-(p-tolyl)-1,3,2-dioxaborinane (TDB) can be readily synthesized in one step using inexpensive materials and incorporated into the organic glass scintillator at 20% by weight or 0.25% 10 B by mass. In addition, we demonstrate that TDB can be easily scaled up and formulated into organic glass scintillator samples to produce a thermal neutron capture signal with a light yield equivalent to 120.4 ± 3.7 keVee, which is the highest value reported in the literature to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How silicon and boron dopants govern the cryogenic scintillation properties of N -type GaAs

This work is the first report describing how the concentrations of silicon and boron govern the cryogenic scintillation properties of n-type GaAs. It shows that valence band holes are promptly trapped on radiative centers and then combine radiatively with silicon donor band electrons at rates that increase with the density of free carriers. It also presents the range of silicon and boron concentrations needed for efficient light emission under X-ray excitation, which along with its low band gap and apparent absence of afterglow, make scintillating GaAs suitable for the detection of rare, low-energy electronic excitations from interacting dark matter particles. A total of 29 samples from four different suppliers were studied. Luminosities and timing responses were measured for the four principal emission bands centered at 860, 930, 1070, and 1335 nm, and for the total emissions. Excitation pulses of 40 kVp X-rays were provided by a light-excited X-ray tube driven by an ultra-fast laser. Scintillation emissions from 800 to 1350 nm were measured using an InGaAs photomultiplier. Within the concentration ranges of free carriers from 2 x 10 16 /cm 3 to 6 x 10 17 /cm 3 and boron from 1.5 × 10 18 /cm 3 to 6 x 10 18 /cm 3 , nine samples have luminosities > 70 photons/keV and two have luminosities > 110 photons/keV. Other samples in that range have lower luminosities due to higher concentrations of non-radiative centers. The decay times decrease by typically a factor of ten with increasing free carrier concentrations from 10 17 /cm 3 to 2 x 10 18 /cm 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗