Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Retrofitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Airflow Resistance of Loose-Fill Mineral Fiber Insulations in Retrofit Applications

This report expands on Building America Report 1109 by applying the experimental apparatus and test method to dense-pack retrofit applications using mineral fiber insulation materials. Three fiber glass insulation materials and one stone wool insulation material were tested, and the results compared to the cellulose results from the previous study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: Trial Demonstration of Area Lighting Retrofit, Yuma Border Patrol, Yuma, Arizona

Along the Yuma Sector Border Patrol Area in Yuma, Arizona, the GATEWAY program conducted a trial demonstration in which the incumbent quartz metal halide area lighting was replaced with LED at three pole locations at the Yuma Sector Border Patrol Area in Yuma, Arizona. The retrofit was documented to better understand LED technology performance in high-temperature environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance Slab-on-Grade Foundation Insulation Retrofits

A more accurate assessment of slab-on-grade foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulation at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon Absorber Retrofit Equipment (CARE)

During Project DE-FE0007528, CARE (Carbon Absorber Retrofit Equipment), Neumann Systems Group (NSG) designed, installed and tested a 0.5MW NeuStream® carbon dioxide (CO 2 ) capture system using the patented NeuStream® absorber equipment and concentrated (6 molal) piperazine (PZ) as the solvent at Colorado Springs Utilities’ (CSU’s) Martin Drake pulverized coal (PC) power plant. The 36 month project included design, build and test phases. The 0.5MW NeuStream® CO 2 capture system was successfully tested on flue gas from both coal and natural gas combustion sources and was shown to meet project objectives. Ninety percent CO 2 removal was achieved with greater than 95% CO 2 product purity. The absorbers tested support a 90% reduction in absorber volume compared to packed towers and with an absorber parasitic power of less than 1% when configured for operation with a 550MW coal plant. The preliminary techno-economic analysis (TEA) performed by the Energy and Environmental Research Center (EERC) predicted an over-the-fence cost of $25.73/tonne of CO 2 captured from a sub-critical PC plant.

01 COAL, LIGNITE, AND PEAT↗

Achieving a Net Zero Energy Retrofit – in a humid, temperate climate – lessons from the University of Hawai’i at M&#257noa

The University of Hawai’i at M&#257noa (UHM) partnered with the US Department of Energy (DOE) and the Hawai`i Clean Energy Initiative to develop and implement solutions to retrofit exiting buildings to reduce energy consumption by at least 30% as part of DOE’s Commercial Building Partnerships (CBP) Program1. Kuykendall Hall, located on the UHM campus in Honolulu, was the focus of a CBP analysis and design collaboration among the University of Hawai’i, their consultants, and Lawrence Berkeley National Laboratory (LBNL). Kuykendall Hall consists of two 1960s-era wings – a four-story wing containing classrooms, and a seven-story tower containing offices – with a total floor area of approximately 76,000 square feet (ft²).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

White Paper: Unleashing Energy Efficiency Retrofits Through Energy Performance Contracts in China and the United States

Energy performance contracting (EPC) is a mechanism that uses private sector investment and expertise to deploy energy efficiency retrofits in buildings, industries, and other types of facilities. China and the United States both have large, growing EPC markets. This White Paper shares key insights on each market, including strengths and barriers inherent to these markets, compares the two markets, and sets forth options for enhancing EPC markets in each country. The White Paper concludes with recommendations structured around common goals of both countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Refrigeration: Heat Transfer Optimization and Energy Reduction, Measurement and Verification of a Liquid Refrigerant Pump System Retrofit

This study describes the test results of a Refrigerant Pump System integrated into a commercial supermarket direct expansion (DX) vapor compression refrigeration system. The Liquid Refrigerant Pump System retrofit (patent-pending; application number 13/964,198) was introduced to NREL in August 2014 by CTA Architects Engineers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Long-Life-Cycle, Highly Water-Resistant Solar Reflective Retrofit Roof Coating

Highly water-resistant and solar-reflective coatings for low-slope roofs are potentially among the most economical retrofit approaches to thermal management of the building envelope. Therefore, they represent a key building technology research program within the Department of Energy. Research efforts in industry and the Department of Energy are currently under way to increase long-term solar reflectance on a number of fronts. These include new polymer coatings technologies to provide longer-lasting solar reflectivity and improved test methodologies to predict long-term soiling and microbial performance. The focus on long-term improvements in soiling and microbial resistance for maximum reflectance does not address the single most important factor impacting the long-term sustainability of low-slope roof coatings: excellent water resistance. The hydrophobic character of asphaltic roof products makes them uniquely suitable for water resistance, but their low albedo and poor exterior durability are disadvantages. A reflective coating that maintains very high water resistance with increased long-term resistance to soiling and microbial activity would provide additional energy savings and extend roof service life.

36 MATERIALS SCIENCE↗

Technology Solutions for New and Existing Homes Case Study: Optimized Slab-on-Grade Foundation Insulation Retrofits

A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulation at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Solid Sorbents as a Retrofit Technology for CO 2 Capture

ADA completed a DOE-sponsored program titled Evaluation of Solid Sorbents as a Retrofit Technology for CO 2 Capture under program DE-FE0004343. During this program, sorbents were analyzed for use in a post-combustion CO 2 capture process. A supported amine sorbent was selected based upon superior performance to adsorb a greater amount of CO 2 than the activated carbon sorbents tested. When the most ideal sorbent at the time was selected, it was characterized and used to create a preliminary techno-economic analysis (TEA). A preliminary 550 MW coal-fired power plant using Illinois #6 bituminous coal was designed with a solid sorbent CO 2 capture system using the selected supported amine sorbent to both facilitate the TEA and to create the necessary framework to scale down the design to a 1 MWe equivalent slipstream pilot facility. The preliminary techno-economic analysis showed promising results and potential for improved performance for CO 2 capture compared to conventional MEA systems. As a result, a 1 MWe equivalent solid sorbent system was designed, constructed, and then installed at a coal-fired power plant in Alabama. The pilot was designed to capture 90% of the CO 2 from the incoming flue gas at 1 MWe net electrical generating equivalent. Testing was not possible at the design conditions due to changes in sorbent handling characteristics at post-regenerator temperatures that were not properly incorporated into the pilot design. Thus, severe pluggage occurred at nominally 60% of the design sorbent circulation rate with heated sorbent, although no handling issues were noted when the system was operated prior to bringing the regenerator to operating temperature. Testing within the constraints of the pilot plant resulted in 90% capture of the incoming CO 2 at a flow rate equivalent of 0.2 to 0.25 MWe net electrical generating equivalent. The reduction in equivalent flow rate at 90% capture was primarily the result of sorbent circulation limitations at operating temperatures combined with pre-loading of the sorbent with CO 2 prior to entering the adsorber. Specifically, CO 2 -rich gas was utilized to convey sorbent from the regenerator to the adsorber. This gas was nominally 45°C below the regenerator temperature during testing. ADA’s post-combustion capture system with modifications to overcome pilot constraints, in conjunction with incorporating a sorbent with CO 2 working capacity of 15 g CO 2 /100 g sorbent and a contact time of 10 to 15 minutes or less with flue gas could provide significant cost and performance benefits when compared to an MEA system.

36 MATERIALS SCIENCE↗

Eliminating the Derate of Carbon Capture Retrofits

Retrofitting existing PC plants with amine-based CO 2 capture technology is thermally- and power-intensive. This study examines the benefit of installing a natural gas simple cycle to provide the auxiliaries required to operate the amine system such that the original power demand can still be met.

20 FOSSIL-FUELED POWER PLANTS↗

Coal-Fired Power Plants in the United States: Examination of the Costs of Retrofitting with CO 2 Capture Technology, Revision 3

This report describes the development of a database and geographic information systems (GIS) analysis of a defined population of coal-fired power plants in the U.S. to model the cost and assist in the assessment of the feasibility of retrofitting these plants with CO 2 capture technology. In addition, an assessment of the impacts on generation, CO 2 emission, and fuel consumption should all units be brought up to the average efficiency of the top decile of efficient units by nameplate was made. This report covers data sources, methodology employed, modeling and results. An appendix containing a catalog of aerial imagery used for this analysis is available as a separate document.

20 FOSSIL-FUELED POWER PLANTS↗

Environmental Retrofit Tracking

This presentation tracks environmental retrofits to the existing coal-fired power fleet, through various stages of project development. Many of the environmental compliance strategies that are expected to be implemented are analyzed with respect to recent regulatory initiatives, that may impact the existing coal-fired asset base.

01 COAL, LIGNITE, AND PEAT↗

User Guide for the Public Industrial CO 2 Capture Retrofit Database Models

The United States (U.S.) Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) has produced three carbon capture retrofit databases (CCRDs), which contain a collection of units selected from the power generation and industrial sources (IND) sectors located in the United States that are either in operating or standby status. The power generation category is subdivided into the post-combustion (PC) CCRD – containing coal-fired and atmospheric fluidized bed (AFB) units – and the natural gas combined cycle (NGCC) CCRD – containing natural gas-fired combined cycle and combined cycle single shaft units. The IND CCRD contains facilities from the ammonia, cement, ethanol, hydrogen, and natural gas processing industries. This report is intended to provide a general guide to the IND CCRD. Efforts have been made to ensure similarities between each of the CCRDs. However, as the sources of CO2 vary, differences will exist – most notably in the IND CCRD.

03 NATURAL GAS↗

EXPC Plant CCS Retrofit, Construction

Material inputs for retrofitting an existing pulverized coal (EXPC) power plant with carbon capture and sequestration (CCS). To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=03FD6C0E-5DA6-4455-9374-78A247D946BB

01 COAL, LIGNITE, AND PEAT↗

Industrial Sources Carbon Capture Retrofit Database

This tool provides high-level analysis on the incremental costs for retrofitting point sources with carbon dioxide (CO 2 ) capture and/or compression systems applied to various high purity industrial CO 2 sources. Options are available to include costs of other technological improvements that would be required to comply with various regulations and New Source Performance Standards when installing CO 2 scrubbing technology.

54 ENVIRONMENTAL SCIENCES↗

Natural Gas Combined Cycle Carbon Capture Retrofit Database

This tool provides high-level analysis on the incremental costs for retrofitting point sources with carbon dioxide (CO 2 ) capture and/or compression systems. Options are available to include costs of other technological improvements that would be required to comply with various regulations and New Source Performance Standards when installing CO 2 scrubbing technology.

03 NATURAL GAS↗

Pulverized Coal Carbon Capture Retrofit Database

This tool provides a high level analysis on the incremental costs for retrofitting point sources with CO 2 capture and compression systems. Options are available to include cost of other technological improvements that would be required to comply with various regulations and new source performance standard when installing CO 2 capture technology.

01 COAL, LIGNITE, AND PEAT↗