Development of a unit cell for a Ge:Ga detector array

Two modules of gallium-doped germanium (Ge:Ga) infrared detectors with integrated multiplexing readouts and supporting drive electronics were designed and tested. This development investigated the feasibility of producing two-dimensional Ge:Ga arrays by stacking linear modules in a housing capable of providing uniaxial stress for enhanced long-wavelength response. Each module includes 8 detectors (1x1x2 mm) mounted to a sapphire board. The element spacing is 12 microns. The back faces of the detector elements are beveled with an 18 deg angle, which was proved to significantly enhance optical absorption. Each module includes a different silicon metal-oxide semiconductor field effect transistor (MOSFET) readout. The first circuit was built from discrete MOSFET components; the second incorporated devices taken from low-temperature integrated circuit multiplexers. The latter circuit exhibited much lower stray capacitance and improved stability. Using these switched-FET circuits, it was demonstrated that burst readout, with multiplexer active only during the readout period, could successfully be implemented at approximately 3.5 K.

Source record↗

Delay line anodes for microchannel-plate spectrometers

A photon-counting readout system for microchannel-plate spectrometers is described that uses a delay line and timing circuit for the wavelength coordinate and a wedge-wedge charge division system for the orthogonal spatial coordinate. A novel zigzag layout allows these two anode patterns to coexist on a common planar substrate and share the charge from each photoevent, thereby simultaneously localizing the photon in each of its two dimensions. Unlike wedge-and-strip or resistive anode encoders, the delay line offers a spatial resolution that is relatively independent of the format length. Unlike discrete anode systems, the delay line readout system's complexity is also independent of the field of view size. These facts make the delay line readout system advantageous in large format detectors. A testbed detector having a delay line propagation speed of 2.2 mm/ns and a time resolution of 33 ps FWHM has been assembled. Ultraviolet testing shows a Gaussian event distribution having a 70-micron FWHM width; the readout system blur contribution is less than 50-micron FWHM.

Lampton, M.↗

Improved low frequency stability of bolometric detectors

An ac bridge readout system has been developed that greatly improves the low-frequency stability of bolometric detectors. The readout can be implemented with a simple circuit appropriate for use in space applications. A matched pair of detectors was used in the readout to achieve system noise within a factor of two of the fundamental noise limit of the detectors at frequencies as low as 10 mHz. The low-frequency stability of the readout system allows slower, more sensitive detectors to be used in many applications, and it facilitates observing strategies that are well suited to spaceborne observations.

Wilbanks, T.↗

LDEF Experiment P0006 Linear Energy Transfer Spectrum Measurement (LETSME) quick look report

A preliminary analysis of the various passive radiation detector materials included in the P0006 LETSME experiment flown on LDEF (Long Duration Exposure Facility) is presented. It consists of four tasks: (1) readout and analysis of thermoluminescent detectors (TLD); (2) readout and analysis of fission foil/mica detectors; (3) readout and analysis of (6)LiF/CR-39 detectors; and (4) preliminary processing and readout of CR-39 and polycarbonate plastic nuclear track detectors (PNTD).

Source record↗

Optically Addressable, Ferroelectric Memory With NDRO

For readout, memory cells addressed via on-chip semiconductor lasers. Proposed thin-film ferroelectric memory device features nonvolatile storage, optically addressable, nondestructive readout (NDRO) with fast access, and low vulnerability to damage by ionizing radiation. Polarization switched during recording and erasure, but not during readout. As result, readout would not destroy contents of memory, and operating life in specific "read-intensive" applications increased up to estimated 10 to the 16th power cycles.

Thakoor, Sarita↗

Theory and Development of Position-Sensitive Quantum Calorimeters

Quantum calorimeters are being developed as imaging spectrometers for future X-ray astrophysics observatories. Much of the science to be done by these instruments could benefit greatly from larger focal-plane coverage of the detector (without increasing pixel size). An order of magnitude more area will greatly increase the science throughput of these future instruments. One of the main deterrents to achieving this goal is the complexity of the readout schemes involved. We have devised a way to increase the number of pixels from the current baseline designs by an order of magnitude without increasing the number of channels required for readout. The instrument is a high energy resolution, distributed-readout imaging spectrometer called a Position-Sensitive Transition-Edge Sensor (POST). A POST is a quantum calorimeter consisting of two Transition-Edge Sensors (TESS) on the ends of a long absorber capable of one-dimensional imaging spectroscopy. Comparing rise time and energy information from the two TESS, the position of the event in the POST is determined. The energy of the event is inferred from the sum of the two pulses. We have developed a generalized theoretical formalism for distributed-readout calorimeters and apply it to our devices. We derive the noise theory and calculate the theoretical energy resolution of a POST. Our calculations show that a 7-pixel POST with 6 keV saturation energy can achieve 2.3 eV resolution, making this a competitive design for future quantum calorimeter instruments. For this thesis we fabricated 7- and 15-pixel POSTS using Mo/Au TESs and gold absorbers, and moved from concept drawings on scraps of napkins to a 32 eV energy resolution at 1.5 keV, 7-pixel POST calorimeter.

Figueroa-Feliciano, Enectali↗

Image sensor with high dynamic range linear output

Designs and operational methods to increase the dynamic range of image sensors and APS devices in particular by achieving more than one integration times for each pixel thereof. An APS system with more than one column-parallel signal chains for readout are described for maintaining a high frame rate in readout. Each active pixel is sampled for multiple times during a single frame readout, thus resulting in multiple integration times. The operation methods can also be used to obtain multiple integration times for each pixel with an APS design having a single column-parallel signal chain for readout. Furthermore, analog-to-digital conversion of high speed and high resolution can be implemented.

Yadid-Pecht, Orly↗

Inexpensive Implementation of Many Strain Gauges

It has been proposed to develop arrays of strain gauges as arrays of ordinary metal film resistors and associated electronic readout circuitry on printed circuit boards or other suitable substrates. This proposal is a by-product of a development of instrumentation utilizing metal film resistors on printed-circuit boards to measure temperatures at multiple locations. In the course of that development, it was observed that in addition to being sensitive to temperature, the metal film resistors were also sensitive to strains in the printed-circuit boards to which they were attached. Because of the low cost of ordinary metal film resistors (typically <$0.01 apiece at 2007 prices), the proposal could enable inexpensive implementation of arrays of many (e.g., 100 or more) strain gauges, possibly concentrated in small areas. For example, such an array could be designed for use as a computer keyboard with no moving parts, as a device for sensing the shape of an object resting on a surface, or as a device for measuring strains at many points on a mirror, a fuel tank, an airplane wing, or other large object. Ordinarily, the effect of strain on resistance would be regarded as a nuisance in a temperature-measuring application, and the effect of temperature on resistance would be regarded as a nuisance in a strain-measuring application. The strain-induced changes in resistance of the metal film resistors in question are less than those of films in traditional strain gauges. The main novel aspect of present proposal lies in the use of circuitry affording sufficient sensitivity to measure strain plus means for compensating for the effect of temperature. For an array of metal film resistors used as proposed, the readout circuits would include a high-accuracy analog-to-digital converter fed by a low noise current source, amplifier chain, and an analog multiplexer chain. Corrections would be provided by use of high-accuracy calibration resistors and a temperature sensor. By use of such readout circuitry, it would be possible to read the resistances of as many as 100 fixed resistors in a time interval of 1 second at a resolution much greater than 16 bits. The readout data would be processed, along with temperature calibration data, to deduce the strain on the printed-circuit board or other substrate in the areas around the resistors. It should also be possible to also deduce the temperature from the readings.

Berkun, Andrew C.↗

Unitary Shaft-Angle and Shaft-Speed Sensor Assemblies

The figure depicts a unit that contains a rotary-position or a rotary-speed sensor, plus electronic circuitry necessary for its operation, all enclosed in a single housing with a shaft for coupling to an external rotary machine. This rotation sensor unit is complete: when its shaft is mechanically connected to that of the rotary machine and it is supplied with electric power, it generates an output signal directly indicative of the rotary position or speed, without need for additional processing by other circuitry. The incorporation of all of the necessary excitatory and readout circuitry into the housing (in contradistinction to using externally located excitatory and/or readout circuitry) in a compact arrangement is the major difference between this unit and prior rotation-sensor units. The sensor assembly inside the housing includes excitatory and readout integrated circuits mounted on a circular printed-circuit board. In a typical case in which the angle or speed transducer(s) utilize electromagnetic induction, the assembly also includes another circular printed-circuit board on which the transducer windings are mounted. A sheet of high-magnetic permeability metal ("mu metal") is placed between the winding board and the electronic-circuit board to prevent spurious coupling of excitatory signals from the transducer windings to the readout circuits. The housing and most of the other mechanical hardware can be common to a variety of different sensor designs. Hence, the unit can be configured to generate any of variety of outputs by changing the interior sensor assembly. For example, the sensor assembly could contain an analog tachometer circuit that generates an output proportional (in both magnitude and sign or in magnitude only) to the speed of rotation.

Alhorn, Dean C.↗

Flagging and Correction of Pattern Noise in the Kepler Focal Plane Array

In order for Kepler to achieve its required less than 20 PPM photometric precision for magnitude 12 and brighter stars, instrument-induced variations in the CCD readout bias pattern (our "2D black image"), which are either fixed or slowly varying in time, must be identified and the corresponding pixels either corrected or removed from further data processing. The two principle sources of these readout bias variations are crosstalk between the 84 science CCDs and the 4 fine guidance sensor (FGS) CCDs and a high frequency amplifier oscillation on less than 40% of the CCD readout channels. The crosstalk produces a synchronous pattern in the 2D black image with time-variation observed in less than 10% of individual pixel bias histories. We will describe a method of removing the crosstalk signal using continuously-collected data from masked and over-clocked image regions (our "collateral data"), and occasionally-collected full-frame images and reverse-clocked readout signals. We use this same set to detect regions affected by the oscillating amplifiers. The oscillations manifest as time-varying moir pattern and rolling bands in the affected channels. Because this effect reduces the performance in only a small fraction of the array at any given time, we have developed an approach for flagging suspect data. The flags will provide the necessary means to resolve any potential ambiguity between instrument-induced variations and real photometric variations in a target time series. We will also evaluate the effectiveness of these techniques using flight data from background and selected target pixels.

Kolodziejczak, Jeffery J.↗

Event-Driven Random-Access-Windowing CCD Imaging System

A charge-coupled-device (CCD) based high-speed imaging system, called a realtime, event-driven (RARE) camera, is undergoing development. This camera is capable of readout from multiple subwindows [also known as regions of interest (ROIs)] within the CCD field of view. Both the sizes and the locations of the ROIs can be controlled in real time and can be changed at the camera frame rate. The predecessor of this camera was described in High-Frame-Rate CCD Camera Having Subwindow Capability (NPO- 30564) NASA Tech Briefs, Vol. 26, No. 12 (December 2002), page 26. The architecture of the prior camera requires tight coupling between camera control logic and an external host computer that provides commands for camera operation and processes pixels from the camera. This tight coupling limits the attainable frame rate and functionality of the camera. The design of the present camera loosens this coupling to increase the achievable frame rate and functionality. From a host computer perspective, the readout operation in the prior camera was defined on a per-line basis; in this camera, it is defined on a per-ROI basis. In addition, the camera includes internal timing circuitry. This combination of features enables real-time, event-driven operation for adaptive control of the camera. Hence, this camera is well suited for applications requiring autonomous control of multiple ROIs to track multiple targets moving throughout the CCD field of view. Additionally, by eliminating the need for control intervention by the host computer during the pixel readout, the present design reduces ROI-readout times to attain higher frame rates. This camera (see figure) includes an imager card consisting of a commercial CCD imager and two signal-processor chips. The imager card converts transistor/ transistor-logic (TTL)-level signals from a field programmable gate array (FPGA) controller card. These signals are transmitted to the imager card via a low-voltage differential signaling (LVDS) cable assembly. The FPGA controller card is connected to the host computer via a standard peripheral component interface (PCI).

Monacos, Steve↗

Microwave Kinetic Inductance Detector with Selective Polarization Coupling

A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

Wollack, Edward↗

Photoacoustic Chemical Detector

A laser vibrometer for measurement of ambient chemical species includes a laser that produces a beam that is split into a reference readout beam and a signal readout beam. A probe laser beam is tuned to an absorption feature of a molecular transition, and generates acoustic signals when incident on a gaseous species via the photo acoustic effect. The scattered acoustic signals are incident on a thin membrane that vibrates. The readout laser beam reflected from the vibrating membrane is mixed with the reference beam at the surface of a photo-EMF detector. Interferrometric fringes are generated at the surface of the photo-EMF detector. Electric current is generated in the photo-EMF detector when the fringes are in motion due to undulations in the signal readout beam imparted by the vibrating membrane. A highly sensitive photo-EMF detector is capable of detecting picoJoules or less laser energy generated by vibrating processes.

Prasad, Narasimha S.↗

Performance of a broad-band, high-resolution, transition-edge sensor spectrometer for X-ray astrophysics

Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA’s Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including >200 pixels, of:1.95 eV for Ti-Ka(4.5 keV), 1.97eV for Mn-Ka(5.9 keV), 2.16 eV for Co-Kα(6.9 keV),2.33 eV for Cu-Kα(8 keV), 3.26 eV for Br-Kα(11.9 keV). The 1 sigma statistical errorsare£0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.

S J Smith↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background(CMB)science depend on increasing the number of sensitive detectorsobserving the sky. New instruments deploy large arrays of superconducting transition-edge sensor(TES)bolometers tileddensely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers andsimplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexingfactor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, whichemploys microwave SQUID multiplexing(μmux). Simons Observatory will use 49 modules containing 70,000bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design,presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor.The median white noise of each readout channel is 65pA Hz. This impacts the projected SO mapping speed by<8%,which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. Wediscuss the measured performance in the context of SO science requirements, which are exceeded.

Heather McCarrick↗

TQEA: Temporal Quantum Error Analysis

For the last few years quantum computers have captured researchers’ interest in solving complicated problems in finance, chemistry, machine learning, and many other NP problems. Quantum computing benefits from parallel computation, entanglement, and calculation speedup compared to classical computing. Even though the operations and number of qubits in quantum computers are limited, previous research showed that using quantum computers can be beneficial. These benefits gained researchers’ interest to work on the improvement of quantum computers and overcome the limitations by building more advanced quantum computers with fault tolerance capability, more physical qubits, and better operational gates. In practice, Quantum applications would be translated into Quantum Circuits and each circuit can contain one or many entanglements (s), single qubits operations, and readouts. The importance of running Quantum applications with controlled errors or without errors is critical to the desired result from Quantum readout. In this paper, we study the characteristics of superconducting quantum machines along with the previously proposed methods of Quantum error detection/correction and in order to build a better error model we propose a temporal method for analyzing the the behavior of qubits errors (T1 and T2), frequency of operation, entanglement errors, and readout errors. In order to detect and predict the behavior of each machine, we use simple exponential smoothing analysis on heuristic calibration data. Finally, based on observation, we show that based on frequency, qubits, readout and single operation errors we can build a temporal based model to study and predict the outcome of runs on each Quantum machine.

Baheri, Betis↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

RD53A: A large-scale prototype chip for the phase II upgrade in the serially powered HL-LHC pixel detectors

The phase II upgrade of the HL-LHC experiments within the LHC intends to deepen the studies of the Higgs boson and to allow the discovery of further particles by adding an integrated luminosity of about 4000 fb -1 over 10 years of operation. This upgrade would overwhelm the installed pixel detector readout chips with higher hit rates and radiation levels than ever before. To match these extreme requirements the RD53 collaboration, a joint effort between ATLAS and CMS, developed RD53A, a new generation pixel detector readout chip prototype manufactured in a 65 nm CMOS technology. It is half the size of the final pixel chips and designed to meet requirements in the face of 3 GHz/cm 2 hit rate after irradiation to 500 Mrad. The detector is able to use 50×50 μm 2 or 25×100 μm 2 pixels with high readout speed of up to 4 links per chip with 1.28 Gbit/s each. Shunt–LDO regulators integrated on the bottom of the chip provide the required voltages to the two power domains, analog and digital. These regulators enable serial powering of the pixel modules, which is the only feasible, radiation hard scheme to ensure acceptable power cable losses and to stay within the material budget for the future pixel detectors. Finally, an overview of the status and challenges of serial powering and the Shunt–LDO regulator development will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗