Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Influence of dissolved salts and impurities on seawater on heat transfer and fluid flow through fuel channels and debris bed

This project aims to better understand this mechanism and its effect on heat transfer. Specifically, experimental research was conducted to investigate the long term coolability issues in scaled test setups. Advanced diagnostic and measurement techniques were investigated and incorporated into an annular test facility and a debris bed test facility. The diagnostic techniques investigated included: radioactively tagged salt solution, Frisch collar radiation detector array, neutron and x-ray imaging systems, and a Rayleigh backscatter-based fiber-optic temperature system. Models were checked against the in-situ experimental data and recommendations were made for modeling purposes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation [Abstract]

The Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR) was a research reactor designed and built at ORNL in 1961. The critical assembly was using a highly enriched uranium and molybdenum alloy as the fuel, and it could be operated in steady-state or burst modes. The reactor was used for about 25 years to produce a lot of publications related to dosimetry, radiobiology and radiation detectors testing before its decommissioning in 1987. In recent years, the idea of using legacy operation data from the to create a valuable critical accident alarm system shielding benchmark arose. Such a benchmark has been submitted to the International Criticality Safety Benchmark Experiment Project (ICSBEP) Technical Review Group for a potential inclusion in the 2022 version of the handbook. Another way to use the valuable data from the operation of the HPRR is to evaluate the feasibility of the creation of a subcritical or prompt supercritical benchmark for inclusion in the ICSBEP or the International Reactor Physics Experiments Evaluation Project (IRPhEP) handbooks. To initiate a burst, the HPRR had to be operated in a slightly subcritical state for a few minutes. Then, the insertion of the burst control rod would greatly increase the reactivity of the system and start the burst. No critical configuration of the HPRR critical assembly could be located. The only information available concerns stable subcritical and prompt supercritical states, found in a burst experiments’ logbook. In the recovered logbook pages, information about 8 different bursts is available. The information includes the rods positions before and during a burst, the recorded subcritical reactor period and reactivity, and the burst fission yield derived from the temperature elevation sulfur pellet irradiation analysis. By using the HPRR logbook information and the as-built drawings of the critical assembly, a highly detailed model of the HPRR was created with SCALE 6.2.4/KENO-VI. Eight KENO-VI models were created to replicate the sub-critical assembly configurations described in the eight bursts from the recovered logbook pages. KENO-VI calculates k eff and it can be linked to a reactivity value in cents by using the delayed neutron fraction B eff , also calculated by KENO-VI. KENO-VI can also be used to model the prompt super-critical configurations of the HPRR and to assess the similarity with the burst measurements by comparing the calculated k eff and the measured fission yields between each burst. Unfortunately, high uncertainty exist and the obtained discrepancies between experiments and calculation results are high, compromising the creation of a valuable critical benchmark from HPRR operation data. The reasons of the discrepancies and potential ways to solve them are explored.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integration of Nuclear Material Accounting Data and Process Monitoring Data for Improvement on Detection Probability in Safeguarding Electrochemical Processing Facilities (Final Technical Report)

The KAERI advanced spent fuel conditioning process (ACP) process is a critical component of the US- South Korean nuclear cooperation and the following “123 Agreement.” Its development has received considerable attention in both countries. The ACP is an electrochemical processing (pyroprocessing) that recycles over 96% of the used nuclear fuel (UNF). It is also intrinsically proliferation-resistant in theory. In normal operation, the U/TRU product is very hot radiologically. In addition, the Cm provides a high level of spontaneous neutrons, making the product unsuitable for weapon use. However, as pointed in some study, “the need for safeguards to protect against the diversion and misuse of separated plutonium applies essentially equally to all grades of plutonium.” As pointed by many studies, the well-established traditional Nuclear Material Accounting (NMA) approach cannot be directly applied to electrochemical processing because of the lack of an input accountability tank, the non-continuous material flow, and the unsatisfactory level of confidence in sampling methods. Therefore, nuclear safeguards remain a grand challenge in the developing of commercial electrochemical separations facilities, especially around the heart of such facilities, the electrorefiner (ER) systems. In contrast to NMA data, process monitoring (PM) data is normally an indirect measurement of the SNM and is acquired much more frequently. In a broad sense, PM includes monitoring by various types of equipment, e.g. radiation detectors, cameras, voltage, current sensors. Because it is already being collected by the operator, the additional cost to safeguards is low. It has long been believed that PM data can supplement NMA data and help improve safeguards, although the benefits are hard to quantify. The U.S. DOE’s Material Protection, Accounting, and Control Technology (MPACT) campaign has made substantial investments into innovative PM sensor technology and predictive model development for real- or near real-time measurement and prediction of molten salt density and level, salt composition and actinide concentration especially Pu, the cell voltage, and the cell current to supplement traditional NMA. For aqueous-based reprocessing facilities, it is reported that PM, integrated with traditional NMA, have a high detection probability for specific diversions. For electrochemical reprocessing, preliminary studies have shown that PM data can support traditional NMA in various ways by providing a basis to estimate some of the in-processing nuclear material inventories. Despite early success, further studies on fusion of PM data and NMA data are still needed, which is the goal of this proposed work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microscale device and method for purification of radiopharmaceuticals

A microfluidic chip device for the purification of radiochemical compounds includes a chip having an injection channel and intersecting branch channels with a plurality of valves are located along the injection channel and branch channels and configured to retain a plug of solution containing the radiochemical compound. The chip further includes a serpentine channel segment (for separation) coupled to the output of the injection channel. A high voltage power source advances the plug of solution through the purification region and into the downstream fraction collection channel. The chip includes a downstream fraction collection channel coupled to the serpentine channel segment and having an optical and radiation detection regions. One or more branch fraction channels intersect with the fraction collection channel and include valves located therein so that the radiochemical compound that is detected using a radiation detector is directed into the desired branch fraction channel for subsequent use.

Van Dam, R. Michael↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Intelligent Pixel Detectors: Towards a Radiation Hard ASIC with On-Chip Machine Learning in 28 nm CMOS

Detectors at future high energy colliders will face enormous technical challenges. Disentangling the unprecedented numbers of particles expected in each event will require highly granular silicon pixel detectors with billions of readout channels. With event rates as high as 40 MHz, these detectors will generate petabytes of data per second. To enable discovery within strict bandwidth and latency constraints, future trackers must be capable of fast, power efficient, and radiation hard data-reduction at the source. We are developing a radiation hard readout integrated circuit (ROIC) in 28nm CMOS with on-chip machine learning (ML) for future intelligent pixel detectors. We will show track parameter predictions using a neural network within a single layer of silicon and hardware tests on the first tape-outs produced with TSMC. Preliminary results indicate that reading out featurized clusters from particles above a modest momentum threshold could enable using pixel information at 40 MHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prediction of Leakage Current and Depletion Voltage in Silicon Detectors Under Extraterrestrial Radiation Conditions

Silicon detection is a mature technology for registering the passage of charged particles. At the same time it continues to evolve toward increasing radiation tolerance as well as precision and adaptability. For these reasons it is likely to remain a critical element of detection of systems associated with extraterrestrial exploration. Silicon sensor leakage current and depletion voltage depend on the integrated fluence received by the sensor and on its thermal history during and after the irradiation process. For minimal assumptions on shielding and hence on the particle energy spectrum, and using published data on Martian ground temperature, we predict the leakage current density and the depletion voltage, as a function of time, of silicon sensors in transit to and deployed continuously on the Mars surface for a duration of up to 28 Earth-years, for several sensor geometries and a worst-case temperature scenario.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Elevation Radiation Array (HERA) detectors for airborne thunderstorm investigations

A high-energy atmospheric physics phenomenon, referred to as a terrestrial gamma ray flash (TGF), is associated with lightning and produces large bursts of energetic photon radiation. TGFs will be investigated using a suite of gamma-ray instruments designed and constructed to fly on ten United States Air Force (USAF) WC-130J Hurricane Hunter aircraft as part of an aircrew ionization study led by the Air Force Institute of Technology (AFIT) and the United States Air Force School of Aerospace Medicine (USAFSAM), in cooperation with the 53rd Weather Reconnaissance Squadron (WRS). Each instrument consists of one NaI and one plastic detector, a GPS timing device, and an instrument computer that performs data acquisition. High Elevation Radiation Array (HERA) detectors will be employed to maximize the chances of observing TGFs near their source and to gain a better understanding of their origin, mechanism, ubiquity, and to assess potential hazards posed to military and commercial aircrew and passengers. The HERA program, deployed on 10 separate Air Force aircraft over a multi-year campaign, will result in thousands of observational flight hours and be the largest concerted effort to date to observe TGFs in situ through aircraft observations. In this paper, we give an overview of the scientific goals of this campaign and how the HERA instruments have been designed to meet those goals. Here, we include a detailed description of the HERA instrument, along with mass model and signal processing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High field CdS detector for infrared radiation

New and highly sensitive method of detecting infrared irradiation makes possible solid state infrared detector which is more sensitive near room temperature than usual photoconductive low band gap semiconductor devices. Reconfiguration of high field domains in cadmium sulphide crystals provides basis for discovery.

Tyagi, R. C.↗

A Xylophone Detector of Gravitational Radiation

We discuss spacecraft Doppler tracking searches for gravitational waves in which Doppler data recorded on the ground are linearly combined with Doppler measurements made on board a spacecraft. By using the four-link radio system first proposed by Vessot and Levine, we describe a new method for removing from the combined data the frequency fluctuations due to the Earth troposphere, ionosphere, and mechanical vibrations of the antenna on the ground. This technique provides also a way for reducing by several orders of magnitude, at selected Fourier components, the frequency fluctuations due to other noise sources, such as the clock on board the spacecraft or the antenna and buffeting of the probe by nongravitational forces. In this respect spacecraft Doppler tracking can be regarded as a xylophone detector of gravitational radiation. In the assumption of calibrating the frequency fluctuations induced by the interplanetary plasma, a strain sensitivity equal to 4.7 x 10(exp -18) at 10(exp -3) Hz is estimated. This experimental technique could be extended to other tests of the theory of relativity, and to radio science experiments that rely on high-precision Doppler measurements.

Tinto, Massimo↗

Thermal detector for measuring radiation parameters of pulsed lasers and generators of submillimetre and millimetre ranges

A theoretical formula is derived that makes it possible to establish a relationship between the speed and sensitivity of bolometers with geometric and thermophysical parameters of the receiving element and substrate. The result is confirmed by a preliminary (evaluation) experiment. The proposed thermal detectors can record and measure the radiation power of lasers and generators of the submillimetre (SMM) and millimetre (MM) ranges. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of ionizing radiation on cryogenic infrared detectors

The Diffuse Infrared Background Experiment (DIRBE) is one of three experiments to be carried aboard the Cosmic Background Explorer (COBE) satellite scheduled to be launched by NASA on a Delta rocket in 1989. The DIRBE is a cryogenic absolute photometer operating in a liquid helium dewar at 1.5 K. Photometric stability is a principal requirement for achieving the scientific objectives of this experiment. The Infrared Astronomy Satellite (IRAS), launched in 1983, which used detectors similar to those in DIRBE, revealed substantial changes in detector responsivity following exposure to ionizing radiation encountered on passage through the South Atlantic Anomaly (SAA). Since the COBE will use the same 900 Km sun-synchronous orbit as IRAS, ionizing radiation-induced performance changes in the detectors were a major concern. Here, ionizing radiation tests carried out on all the DIRBE photodetectors are reported. Responsivity changes following exposure to gamma rays, protons, and alpha particle are discussed. The detector performance was monitored following a simulated entire mission life dose. In addition, the response of the detectors to individual particle interactions was measured. The InSb photovoltaic detectors and the Blocked Impurity Band (BIB) detectors revealed no significant change in responsivity following radiation exposure. The Ge:Ga detectors show large effects which were greatly reduced by proper thermal annealing.

Moseley, S. H.↗

Device response principles and the impact on energy resolution of epitaxial quantum dot scintillators with monolithic photodetector integration

Abstract Epitaxial quantum dot (QD) scintillator crystals with picosecond-scale timing and high light yield have been created for medical imaging, high energy physics and national security applications. Monolithic photodetector (PD) integration enables the sensing of photons generated within the waveguiding crystal and allows a wide range of scintillator-photodetector coupling geometries. Until recently, these doubly novel devices have suffered from complex, high variance responses to monoenergetic sources which significantly reduces their precision and accuracy. The principles governing the overall device response have now been discerned and embodied by an expression derived within a geometrical optics framework which considers optical properties, surface roughness and photodetector coupling geometry. Response variation due to these factors was sufficiently reduced to obtain material-related energy resolution values of 2.4% with alpha particles. These findings place energy resolution alongside luminescence timescale, photon yield, and radiation hardness as outstanding properties of these engineered materials.

36 MATERIALS SCIENCE↗

Spacecraft to Spacecraft Coherent Laser Tracking as a Xylophone Interferometer Detector of Gravitational Radiation

Searches for gravitational radiation can be performed in space with two spacecraft tracking each other with coherent laser light. This experimental technique could be implemented with two spacecraft carrying an appropriate optical payload, or with the proposed broad-band, space-based laser interferometer detectors of gravitational waves operated in this non-interferometric mode.

interferometer↗