Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Environmental Radiation Measurements on the Mir Space Station: Internal Experiment Program - Program 1

As part of the NASA/Mir Phase 1B Science Program, the ionizing radiation environment inside and outside the Russian Mir's Space Station was monitored using a combination of Thermoluminescent Detectors (TLD) and CR-39 Plastic Nuclear Track Detectors (PNTD). Radiation measurements inside the Mir station were carried out using six Area Passive Dosimeters (APD), four located inside the Mir Base Block and two located inside the Kvant 2 module, during the NASA-2/Mir-21, NASA-3/Mir-22 and NASA-4/Mir-23 missions. The radiation environment under low shielding was measured using an External Dosimeter Array (EDA) mounted on the outer surface of the Kvant 2 module. The external radiation environment and a location inside the Kvant 2 roughly corresponding to the location of the EDA were monitored for 130 days during the NASA- 4/Mir-23 and NASA-5/Mir-24 missions. Dose rates measured by APD TLDs ranged from 271 to 407 microGy/d during the NASA-2/Mir-21 mission, from 265 to 378 microGy/d during the NASA-3/Mir-22 mission, and from 287 to 421 microGy/d during the NASA-4/Mir-23 mission. APD PNTDs have been analyzed and LET spectra have been Cenerated for the five APDs exposed on the NASA-2/Mir-21 mission and for two APD PNTDs exposed on the NASA-3/Mir-22 mission. Dose equivalent rates on the NASA-2/Mir-21 mission ranged from 513 microSv/d in the Kvant 2 module to 710 microSv/d on the floor of the Base Block. Dose as a function of shielding depth in TLDs has been measured in the thin TLD stacks including in the EDA. EDA dose range from 72.5 Gy under 0.0146 g/sq cm to 0.093 Gy under 3.25 g/sq cm of shielding. Readout and analysis of the reaming PNTDs form the NASA-3/Mir-22 mission and PNTDs from the NASA-4/Mir-23 mission (including those from the EDA) is ongoing and will be completed during the final year of this experiment. Dose equivalent rates for the NASA-3/Mir-22 and NASA-4/Mir-23 APDs will then be determined and comparisons will be made with both model calculations and with results from similar measurements.

Benton, E. V.↗

Model calculations of the radiation dose and LET spectra on LDEF and comparisons with flight data

Ionizing radiation environment models, a 3-D spacecraft mass model, and radiation transport codes have been used to predict the radiation dose and linear energy transfer (LET) spectra measured at various locations on the LDEF satellite. The predictions are compared with thermoluminescent dosimeter measurements of the trapped proton and electron doses and with LET spectra measured by plastic nuclear track detectors. The predicted vs observed comparisons indicate some of the uncertainties of present ionizing radiation environment models for low Earth-orbit missions.

LDEF Project↗

Experiment M404: Proton electron spectrometer

A series of experiments were performed during the Gemini 4 mission to acquire a detailed description of the radiation environment. Data from these experiments were used as source terms for the calculation of radiation doses received by the crewmembers. Comparison of theory with experimental data was accomplished by the use of dosimeters to monitor the integrated dose received by each crewmember. The instantaneous direction of the magnetic field of the earth relative to the spectrometer was used in the reduction of data because particle intensities were strongly directional with respect to the magnetic field. The simultaneous measurement of the external radiation environment and the radiation dose received by the crewmen during a mission was useful to evaluate and perfect calculational techniques.

Marbach, J. R.↗

Radiation Effects on Line Heat Detection Cable AP Hot Cells Fire Detection at Brookhaven National Laboratory

Hot cells are used to safely shield workers from high radiation environments while allowing a process to take place within the cell's shielded enclosure, often with the assistance of remote manipulators. The interior of a cell may not be accessible by personnel for years at a time, either due to the lingering radiation environment or due to the constant use of these specialized pieces of equipment. High radiation levels are known to cause undesirable effects and changes to different materials in varying degrees. Selecting equipment for a radiation environment requires an evaluation of materials used (preferably completed assembles), to ensure all interactions of materials are known and ensure that the equipment will have a high degree of reliability and functionality over the intended life of the facility. Hot cells contain systems to support the primary purpose of the enclosure. Fire detection is one such support system. Safety of hot cell operations often establish limits on the amounts of combustibles with the cells, but the presence of some combustible materials is unavoidable. Fire detection is provided to quickly detect a fire and summon manual intervention before damage is too great. Detection may also be used to initiate fire suppression systems. As a safety system, fire detection needs to remain functional to protect the facility throughout the facility's life. Equally important is that the false alarms from the fire detection are minimized to retain confidence in the alarm system and avoid unnecessary interruptions in the hot cell operations. There are many types of fire detection available with various pros and cons. Not all types of fire detection are suited for hot cell application.

36 MATERIALS SCIENCE↗

Development of a Space Radiation Monte Carlo Computer Simulation

The ultimate purpose of this effort is to undertake the development of a computer simulation of the radiation environment encountered in spacecraft which is based upon the Monte Carlo technique. The current plan is to adapt and modify a Monte Carlo calculation code known as FLUKA, which is presently used in high energy and heavy ion physics, to simulate the radiation environment present in spacecraft during missions. The initial effort would be directed towards modeling the MIR and Space Shuttle environments, but the long range goal is to develop a program for the accurate prediction of the radiation environment likely to be encountered on future planned endeavors such as the Space Station, a Lunar Return Mission, or a Mars Mission. The longer the mission, especially those which will not have the shielding protection of the earth's magnetic field, the more critical the radiation threat will be. The ultimate goal of this research is to produce a code that will be useful to mission planners and engineers who need to have detailed projections of radiation exposures at specified locations within the spacecraft and for either specific times during the mission or integrated over the entire mission. In concert with the development of the simulation, it is desired to integrate it with a state-of-the-art interactive 3-D graphics-capable analysis package known as ROOT, to allow easy investigation and visualization of the results. The efforts reported on here include the initial development of the program and the demonstration of the efficacy of the technique through a model simulation of the MIR environment. This information was used to write a proposal to obtain follow-on permanent funding for this project.

Pinsky, Lawrence S.↗

Resistive memory for radiation resistant non-volatile memory (NSTRF Final Report)

As space programs increase in number and scope, there is an increasing need for radiation-hardened electronic devices and circuits. In particular, missions to high-radiation environments, such as Europa, would greatly benefit from improved radiation hardness in electronic devices. In pursuit of this goal, resistive memory (RRAM) devices were fabricated at SUNY Polytechnic Institute and evaluated for radiation hardness. Our objectives were to produce RRAM devices resistant to high levels of radiation damage and to demonstrate that these devices would improve mission lifetime in high-radiation environments. Furthermore, the underlying mechanisms of radiation were investigated to provide recommendations for radiation-hardening RRAM devices, which could be applied to any candidate RRAM devices being considered for space applications. Devices were fabricated using several fabrication approaches, including patterning by shadow mask, photolithography-based etching, and photolithography-based liftoff. In each of these cases, total ionizing dose (TID) effects and displacement damage dose (DDD) effects were measured. TID effects from exposure to a 60Co gamma source were not observed to cause changes in device resistance or switching parameters in any experiments, with each device tested to at least 20 Mrad(Si). DDD was measured as radiation-generated oxygen vacancies per cm 3 since oxygen vacancies are generally considered to be the active species involved in switching these devices. The lowest DDD level that caused a device to change resistance state was 10 21 vacancies per cm 3 , and most devices failed at 1022 vacancies per cm 3 . This is an extremely high DDD level, even for RRAM devices, which have been reported to fail in the range of 10 17 -10 20 vacancies per cm 3 . For comparison, an example flash memory device failed at 10 15 vacancies per cm 3 . Vendor-fabricated devices with a similar composition to our own were also tested against TID and DDD. The vendor-fabricated devices did not exhibit changes due to TID, up to the tested level of 30 Mrad(Si). Meanwhile, vendor devices exhibited resistance state changes at 10 21 vacancies per cm 3 , similar to our own devices. These results indicate that Ta0x-based RRAM devices may be particularly resilient to both TID and DDD effects. The very high tolerance to radiation effects is most likely due to the high intrinsic concentration of oxygen vacancies within our devices. Based on X-ray photoelectron spectroscopy (XPS) measurements, there are approximately 10 22 oxygen vacancies per cm 3 in our devices as deposited. Most devices failed when the radiation-induced vacancies reached this level, indicating suggesting that a high intrinsic vacancy concentration protects against lower levels of displacement damage. High vacancy concentration likely also protects against TID by facilitating leakage of trapped charge out of the oxide. The use of a thin switching oxide (25 nm Ta0 x , for our devices) is also expected to improve radiation hardness, as there is less room for charge trapping. Therefore, those wishing to produce very radiation-tolerant RRAM devices can probably achieve this by using a thin oxide that contains a high intrinsic concentration of oxygen vacancies. Our devices appear to be very tolerant of radiation effects, and would greatly increase the expected lifetime of a mission to Europa or another high-radiation target compared to flash memory devices. The similar radiation performance of vendor-fabricated devices is promising for adoption of RRAM devices as radiation-hardened memory devices for use in space. With continued commercial development of these devices, RRAM devices are strong candidates for next-generation memories that are inherently rad-hard.

36 MATERIALS SCIENCE↗

Neutron irradiation effects on the corrosion of Zircaloy-4 in a pressurized water reactor environment - 2016-0085

Long-time Advanced Test Reactor (ATR) corrosion weight-gain data from non-fueled α-processed Zircaloy-4 cladding coupons are presented herein. The data were generated in pressurized loops that simulated pressurized water reactor (PWR) chemistry, temperature, and neutron flux conditions. High neutron flux and high-fluence post-transition corrosion rates were accelerated over out-of-flux post-transition corrosion rates by more than 40 times at 270 deg. C and more than 30 times at 310 deg. C We conclude in large part that the acceleration was caused by irradiation-induced changes to the base metal. The effect that irradiation has on the base metal and its effect on corrosion has been shown in the past to be carried over into post-irradiation tests in autoclave environments, but its impact was shown in this study to be accentuated in the in-reactor environment, in which sustained corrosion accelerations were much greater than observed in the postirradiation tests (in non-irradiation environments). This suggests some aspect of the radiation environment potentially acts synergistically with the corrosion film formed from the irradiation-damaged base metal to further accelerate in-reactor corrosion rates. We also present results from detailed microstructural examinations of thick (more than 25 μm) oxide films formed on α-processed Zircaloy-4 grown in a 360 deg. C autoclave and in the reactor. The examinations consisted of optical microscopy, field emission gun scanning electron microscopy, focused ion beam microscopy, analytical electron microscopy, and X-ray diffraction, with a focus on the evolution of the microstructure of the intermetallic precipitates in the oxide films during exposure to autoclave water or to the corroding environment under neutron irradiation. The film microstructure suggests that the water environment was closer to the oxide-metal interface in the films grown in the reactor than in the autoclave-grown corrosion films examined, but it was not obvious from the microstructural examinations how the radiation environment facilitated that effect. (authors)

36 MATERIALS SCIENCE↗

Radiation protection guidelines for space missions

The current radiation protection guidelines of the National Aeronautics and Space Administration (NASA) were recommended in 1970. The career limit was set at 4.0 Sv (400 rem). Using the same approach as in 1970 but current risk estimates, a considerably lower career limit would obtain today. Also, there is now much more information about the radiation environments that will be experienced in different missions. Furthermore, since 1970 women have joined the ranks of the astronauts. For these and other reasons, it was considered necessary to re-examine the radiation protection guidelines. This task has been undertaken by the National Council on Radiation Protection and Measurements Scientific Committee 75. Within the magnetosphere, the radiation environment varies with altitude and inclination of the orbit. In outer space missions, galactic cosmic rays, with the small but important heavy-ion component, determine the radiation environment. The new recommendations for career dose limits, based on lifetime excess risk of cancer mortality, take into account age at first exposure and sex. The career limits range from 1.0 Sv (100 rem) for a 24-y-old female up to 4.0 Sv (400 rem) for a 55-y-old male, compared with the previous single limit of 4.0 Sv (400 rem). The career limit for the lens of the eye has been reduced from 6.0 Sv (600 rem) to 4.0 Sv (400 rem).

NASA Discipline Radiation Health↗

Effects of Ionizing Radiation on Solid Rocket Motor Components

Problems which the solid propellant rocket engineer will encounter in designing for long-term storage in a radiation environment are discussed. A summary of present knowledge of the radiation environment is given. Mechanisms of radiation degradation and its effects on tensile properties of propellant binders are discussed qualitatively. Data from a program of irradiation of several propellants is presented. Properties of two of the propellants were changed significantly by doses of the order of 4 x 10(exp 6) rads.

RADIATION↗

The ultraviolet environment of Mars: biological implications past, present, and future

A radiative transfer model is used to quantitatively investigate aspects of the martian ultraviolet radiation environment, past and present. Biological action spectra for DNA inactivation and chloroplast (photosystem) inhibition are used to estimate biologically effective irradiances for the martian surface under cloudless skies. Over time Mars has probably experienced an increasingly inhospitable photobiological environment, with present instantaneous DNA weighted irradiances 3.5-fold higher than they may have been on early Mars. This is in contrast to the surface of Earth, which experienced an ozone amelioration of the photobiological environment during the Proterozoic and now has DNA weighted irradiances almost three orders of magnitude lower than early Earth. Although the present-day martian UV flux is similar to that of early Earth and thus may not be a critical limitation to life in the evolutionary context, it is a constraint to an unadapted biota and will rapidly kill spacecraft-borne microbes not covered by a martian dust layer. Microbial strategies for protection against UV radiation are considered in the light of martian photobiological calculations, past and present. Data are also presented for the effects of hypothetical planetary atmospheric manipulations on the martian UV radiation environment with estimates of the biological consequences of such manipulations.

NASA Center ARC↗

Charge, energy, and LET spectra measurements of charged particles in P0006 experiment of LDEF

Measurements are under way of the charged particle radiation environment of the LDEF satellite using stacks of plastic nuclear track detectors (PNTDs) placed in different locations of the satellite. In the initial work, the charge, energy, and linear energy transfer (LET) spectra of charged particles were measured with CR-39 double layer PNTDs located on the west end of the satellite. Primary and secondary stopping heavy ions as well as relativistic galactic cosmic rays (mostly iron particles) were measured separately. The results will be compared with similar measurements in other locations on LDEF with different orientation and shielding conditions. The remarkably detailed study of the charged particle radiation environment of the LDEF satellite will lead to a better understanding of the radiation environment of the Space Station Freedom. It will enable more accurate prediction of single event upsets (SEUs) in microelectronics and, especially, more accurate assessment of the risk, contributed by the different components of the radiation field to the health and safety of crew members.

Benton, E. V.↗

LET spectra measurements of charged particles in the P0006 experiment on LDEF

Measurements are under way of the charged particle radiation environment of the Long Duration Exposure Facility (LDEF) satellite using stacks of plastic nuclear track detectors (PNTD's) placed in different locations of the satellite. In the initial work the charge, energy, and linear energy transfer (LET) spectra of charged particles were measured with CR-39 double layer PNTD's located on the west side of the satellite (Experiment P0006). Primary and secondary stopping heavy ions were measured separately from the more energetic particles. Both trapped and galactic cosmic ray (GCR) particles are included, with the latter component being dominated by relativistic iron particles. The results from the P0006 experiment will be compared with similar measurements in other locations on LDEF with different orientation and shielding conditions. The remarkably detailed investigation of the charged particle radiation environment of the LDEF satellite will lead to a better understanding of the radiation environment of the Space Station Freedom. It will enable more accurate prediction of single event upsets (SEU's) in microelectronics and, especially, more accurate assessment of the risk - contributed by different components of the radiation field (GCR's, trapped protons, secondaries and heavy recoils, etc.) - to the health and safety of crew members.

Benton, E. V.↗

CREME96 and Related Error Rate Prediction Methods

Predicting the rate of occurrence of single event effects (SEEs) in space requires knowledge of the radiation environment and the response of electronic devices to that environment. Several analytical models have been developed over the past 36 years to predict SEE rates. The first error rate calculations were performed by Binder, Smith and Holman. Bradford and Pickel and Blandford, in their CRIER (Cosmic-Ray-Induced-Error-Rate) analysis code introduced the basic Rectangular ParallelePiped (RPP) method for error rate calculations. For the radiation environment at the part, both made use of the Cosmic Ray LET (Linear Energy Transfer) spectra calculated by Heinrich for various absorber Depths. A more detailed model for the space radiation environment within spacecraft was developed by Adams and co-workers. This model, together with a reformulation of the RPP method published by Pickel and Blandford, was used to create the CR ME (Cosmic Ray Effects on Micro-Electronics) code. About the same time Shapiro wrote the CRUP (Cosmic Ray Upset Program) based on the RPP method published by Bradford. It was the first code to specifically take into account charge collection from outside the depletion region due to deformation of the electric field caused by the incident cosmic ray. Other early rate prediction methods and codes include the Single Event Figure of Merit, NOVICE, the Space Radiation code and the effective flux method of Binder which is the basis of the SEFA (Scott Effective Flux Approximation) model. By the early 1990s it was becoming clear that CREME and the other early models needed Revision. This revision, CREME96, was completed and released as a WWW-based tool, one of the first of its kind. The revisions in CREME96 included improved environmental models and improved models for calculating single event effects. The need for a revision of CREME also stimulated the development of the CHIME (CRRES/SPACERAD Heavy Ion Model of the Environment) and MACREE (Modeling and Analysis of Cosmic Ray Effects in Electronics). The Single Event Figure of Merit method was also revised to use the solar minimum galactic cosmic ray spectrum and extended to circular orbits down to 200 km at any inclination. More recently a series of commercial codes was developed by TRAD (Test & Radiations) which includes the OMERE code which calculates single event effects. There are other error rate prediction methods which use Monte Carlo techniques. In this chapter the analytic methods for estimating the environment within spacecraft will be discussed.

Adams, James H., Jr.↗

Mars Science Laboratory Radiation Assessment Detector (MSLRAD) Modeling Workshop Proceedings

The Radiation Assessment Detector (RAD) (Hassler et al., 2012) onboard the Mars Science Laboratory (MSL) Curiosity rover (Grotzinger et al., 2012) has been making detailed measurements of the radiation environment on the surface of Mars since landing on 6 August 2012 (Hassler et al., 2014; Zeitlin et al., 2016). These measurements are the first of their kind on the surface of another planet and are providing essential measurements of the radiation environment on Mars in preparation for a human mission in the coming decades. The objectives of RAD are; 1) to characterize the energetic particle spectrum on the surface of Mars as a function of time in the solar cycle, including direct (galactic cosmic rays and solar energetic particles) and indirect (neutrons, etc.) radiation created in the atmosphere and regolith, 2) to determine the dose and dose‐equivalent rates as a function of time in the solar cycle, and 3) to use these observations to test and validate space radiation transport models. Initial results of the charged particle spectra (Ehresmann et al., 2014) and neutral particle spectrum (Köhler et al., 2014), as well as dose and dose‐equivalent during cruise (Zeitlin et al., 2013) and on the surface (Hassler et al., 2014) have been reported, and with almost five years of continuous measurements, RAD continues to characterize the radiation environment as solar minimum is approached.

Donald M Hassler↗

Thermal Analysis of a Finite Element Model in a Radiation Dominated Environment

This paper presents a brief overview of thermal analysis, evaluating the University of Arizona mirror design, for the Next Generation Space Telescope (NGST) Pre-Phase A vehicle concept. Model building begins using Thermal Desktop(Tm), by Cullimore and Ring Technologies, to import a NASTRAN bulk data file from the structural model of the mirror assembly. Using AutoCAD(R) capabilities, additional surfaces are added to simulate the thermal aspects of the problem which, for due reason, are not part of the structural model. Surfaces are then available to accept thermophysical and thermo-optical properties. Thermal Desktop(Tm) calculates radiation conductors using Monte Carlo simulations. Then Thermal Desktop(Tm) generates the SINDA/Fluint input file having a one-to-one correspondence with the NASTRAN node and element definitions. A model is now available to evaluate the mirror design in the radiation dominated environment conduct parametric trade studies of the thermal design, and provide temperatures to the finite element structural model.

Page, Arhur T.↗

Thermal Analysis of a Finite Element Model in a Radiation Dominated Environment

This paper presents a brief overview of thermal analysis, evaluating the University of Arizona mirror design, for the Next Generation Space Telescope (NGST) Pre-Phase A vehicle concept. Model building begins using Thermal Desktop(TM), by Cullimore and Ring Technologies, to import a NASTRAN bulk data file from the structural model of the mirror assembly. Using AutoCAD(R) capabilities, additional surfaces are added to simulate the thermal aspects of the problem which, for due reason, are not part of the structural model. Surfaces are then available to accept thermophysical and thermo-optical properties. Thermal Desktop(TM) calculates radiation conductors using Monte Carlo simulations. Then Thermal Desktop(TM) generates the SINDA input file having a one-to-one correspondence with the NASTRAN node and element definitions. A model is now available to evaluate the mirror design in the radiation dominated environment, conduct parametric trade studies of the thermal design, and provide temperatures to the finite element structural model.

Page, Arthur T.↗

Listening to Radiation Damage In Situ: Passive and Active Acoustic Techniques

Knowing when, why, and how materials evolve, degrade, or fail in radiation environments is pivotal to a wide range of fields from semiconductor processing to advanced nuclear reactor design. A variety of methods, including optical and electron microscopy, mechanical testing, and thermal techniques, have been used in the past to successfully monitor the microstructural and property evolution of materials exposed to extreme radiation environments. Acoustic techniques have also been used in the past for this purpose, although most methodologies have not achieved widespread adoption. However, with an increasing desire to understand microstructure and property evolution in situ, acoustic methods provide a promising pathway to uncover information not accessible to more traditional characterization techniques. This work highlights how two different classes of acoustic techniques may be used to monitor material evolution during in situ ion beam irradiation. The passive listening technique of acoustic emission is demonstrated on two model systems, quartz and palladium, and shown to be a useful tool in identifying the onset of damage events such as microcracking. An active acoustic technique in the form of transient grating spectroscopy is used to indirectly monitor the formation of small defect clusters in copper irradiated with self-ions at high temperature through the evolution of surface acoustic wave speeds. Here, these studies together demonstrate the large potential for using acoustic techniques as in situ diagnostics. Such tools could be used to optimize ion beam processing techniques or identify modes and kinetics of materials degradation in extreme radiation environments.

36 MATERIALS SCIENCE↗

Effects of Stopping Ions and LET Fluctuations on Soft Error Rate Prediction.

Variability in energy deposition from stopping ions and LET fluctuations is quantified for specific radiation environments. When compared to predictions using average LET via CREME96, LET fluctuations lead to an order-of-magnitude difference in effective flux and a nearly 4x decrease in predicted soft error rate (SER) in an example calculation performed on a commercial 65 nm SRAM. The large LET fluctuations reported here will be even greater for the smaller sensitive volumes that are characteristic of highly scaled technologies. End-of-range effects of stopping ions do not lead to significant inaccuracies in radiation environments with low solar activity unless the sensitivevolume thickness is 100 μm or greater. In contrast, end-of-range effects for stopping ions lead to significant inaccuracies for sensitive- volume thicknesses less than 10 μm in radiation environments with high solar activity.

42 ENGINEERING↗