Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Mechanisms and dynamics of the NH + 2 + H + and NH + + H + + H fragmentation channels upon single-photon double ionization of NH 3

We present state-selective measurements on the NH$_2^{+}$ + H$^{+}$ and NH$^{+}$ + H$^{+}$ + H dissociation channels following single-photon double ionization at 61.5 eV of neutral NH$_{3}$, where the two photoelectrons and two cations are measured in coincidence using 3-D momentum imaging. Three dication electronic states are identified to contribute to the NH$_2^{+}$ + H$^{+}$ dissociation channel, where the excitation in one of the three states undergoes intersystem crossing prior to dissociation, producing a cold NH$_2^+$ fragment. In contrast, the other two states directly dissociate, producing a ro-vibrationally excited NH$_2^+$ fragment with roughly 1 eV of internal energy. The NH$^{+}$ + H$^{+}$ + H channel is fed by direct dissociation from three intermediate dication states, one of which is shared with the NH$_2^{+}$ + H$^{+}$ channel. We find evidence of autoionization contributing to each of the double ionization channels. Finally, the distributions of the relative emission angle between the two photoelectrons, as well as the relative angle between the recoil axis of the molecular breakup and the polarization vector of the ionizing field, are also presented to provide insight on the ionization mechanisms for the different dication states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Application of molecular convergent close-coupling cross sections in a collisional radiative model for the triplet system of molecular hydrogen

Collisional radiative (CR) models for molecular hydrogen are of high relevance for performing qualitative and quantitative analysis of excited-state population densities measured in plasmas or predicting the dependence of plasma emission on parameter variations. Although the development of such models for H 2 started decades ago, major uncertainties still exist regarding the most important set of input parameters, namely the cross sections for electron-impact excitation. The deviations between cross sections from different datasets are particularly pronounced in the energy region close to the threshold energy, strongly increasing the uncertainty of CR models applied to low-temperature plasmas. This paper presents experimental validation of a set of newly calculated non ro-vibrationally resolved electron-impact cross sections calculated for the triplet system of H 2 using the molecular convergent close-coupling method in the adiabatic-nuclei formulation. These cross sections are implemented into a CR model based on the flexible solver Yacora. A first comparison of CR calculations with the different datasets to experimentally-determined population densities is performed at a planar ICP discharge for varying pressure (between 1 and 10 Pa) and RF power (between 700 and 1100 W). For the experimentally-accessible electron temperature and density range (2.5–10 eV and 1.8–3.3 × 10 16 m –3 , respectively), very good agreement between the model and experiment is obtained using the new data set, in contrast to previously used cross sections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Breath analysis by ultra-sensitive broadband laser spectroscopy detects SARS-CoV-2 infection

Rapid testing is essential to fighting pandemics such as coronavirus disease 2019 (COVID-19), the disease caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Exhaled human breath contains multiple volatile molecules providing powerful potential for non-invasive diagnosis of diverse medical conditions. We investigated breath detection of SARS-CoV-2 infection using cavity-enhanced direct frequency comb spectroscopy (CE-DFCS), a state-of-the-art laser spectroscopic technique capable of a real-time massive collection of broadband molecular absorption features at ro-vibrational quantum state resolution and at parts-per-trillion volume detection sensitivity. Using a total of 170 individual breath samples (83 positive and 87 negative with SARS-CoV-2 based on reverse transcription polymerase chain reaction tests), we report excellent discrimination capability for SARS-CoV-2 infection with an area under the receiver-operating-characteristics curve of 0.849(4). Our results support the development of CE-DFCS as an alternative, rapid, non-invasive test for COVID-19 and highlight its remarkable potential for optical diagnoses of diverse biological conditions and disease states.

60 APPLIED LIFE SCIENCES↗

COLD ELECTRON REACTIONS PRODUCING THE ENERGETIC ISOMER OF HYDROGEN CYANIDE IN INTERSTELLAR CLOUDS

Using event-by-event fragment momentum spectroscopy in a storage-ring merged-beams experiment, we find laboratory evidence that in the dissociative recombination (DR) of HCNH{sup +} with cold electrons the energetic isomer HNC is produced with a high yield, similar to that of HCN. With a newly implemented mass-sensitive fragment imaging detector, we analyze the kinetic energy release of the triatomic fragments DCN/DNC from the DR reaction of the isotopologue DCND{sup +} with cold (near 10 K) electrons. The results show that the internal energy of these fragments is extremely high, far exceeding the isomerization barrier between DNC and DCN. From this laboratory characterization of the DR reaction we conclude that also the triatomic fragment HCN/HNC from the DR of HCNH{sup +} will carry a large amount of ro-vibrational excitation and show that this implies an isomeric production ratio in a narrow range near unity.

74 ATOMIC AND MOLECULAR PHYSICS↗

SPECTROSCOPIC DETECTION OF CARBON MONOXIDE IN THE YOUNG SUPERNOVA REMNANT CASSIOPEIA A

We report the detection of carbon monoxide (CO) emission from the young supernova remnant Cassiopeia A (Cas A) at wavelengths corresponding to the fundamental vibrational mode at 4.65 {mu}m. We obtained AKARI Infrared Camera spectra toward four positions which unambiguously reveal the broad characteristic CO ro-vibrational band profile. The observed positions include unshocked ejecta at the center, indicating that CO molecules form in the ejecta at an early phase. We extracted a dozen spectra across Cas A along the long 1' slits and compared these to simple CO emission models in local thermodynamic equilibrium to obtain first-order estimates of the excitation temperatures and CO masses involved. Our observations suggest that significant amounts of carbon may have been locked up in CO since the explosion 330 years ago. Surprisingly, CO has not been efficiently destroyed by reactions with ionized He or the energetic electrons created by the decay of the radiative nuclei. Our CO detection thus implies that less carbon is available to form carbonaceous dust in supernovae than is currently thought and that molecular gas could lock up a significant amount of heavy elements in supernova ejecta.

79 ASTRONOMY AND ASTROPHYSICS↗

LABORATORY GAS-PHASE DETECTION OF THE CYCLOPROPENYL CATION (c-C{sub 3}H{sub 3} {sup +})

The cyclopropenyl cation (c-C{sub 3}H{sub 3} {sup +}) is the smallest aromatic hydrocarbon molecule and considered to be a pivotal intermediate in ion-molecule reactions in space. An astronomical identification has been prohibited so far, because of a lack of gas-phase data. Here we report the first high resolution infrared laboratory gas-phase spectrum of the ν {sub 4} (C-H asymmetric stretching) fundamental band of c-C{sub 3}H{sub 3} {sup +}. The c-C{sub 3}H{sub 3} {sup +} cations are generated in supersonically expanding planar plasma by discharging a propyne/helium gas pulse, yielding a rotational temperature of ∼35 K. The absorption spectrum is recorded in the 3.19 μm region using sensitive continuous-wave cavity ring-down spectroscopy. The analysis of about 130 ro-vibrational transitions results in precise spectroscopic parameters. These constants allow for an accurate comparison with high-level theoretical predictions, and provide the relevant information needed to search for this astrochemically relevant carbo-cation in space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiative association of C(3P) and H+: triplet states

The radiative association of $C(^3P)$ and $H^+$ is investigated by calculating cross-sections for photon emission into bound ro-vibrational states of $CH^+$ from the vibrational continua of initial triplet d 3Π or b$^3Σ^-$ states. Potential energy curves and transition dipole moments are calculated using multireference configuration interaction (MRCI) methods with AV6Z basis sets. The cross-sections are evaluated using quantum-mechanical methods and rate coefficients are calculated. The rate coefficients are about 100 times larger than those for radiative association of $C^+(^2P^o)$ and $H$ from the $A$ 1$Π$ state. We also confirm that the formation of $CH^+$ by radiative association of $C^+(^2P^o)$ and $H$ via the triplet c $^3Σ^+$ state is a minor process.

Babb, James F.↗

TH-E-19A-01: Quality and Safety in Radiation Therapy

Clinical radiotherapy data clearly demonstrate the link between the quality and safety of radiation treatments and the outcome for patients. The medical physicist plays an essential role in this process. To ensure the highest quality treatments, the medical physicist must understand and employ modern quality improvement techniques. This extends well beyond the duties traditionally associated with prescriptive QA measures. This session will review the current best practices for improving quality and safety in radiation therapy. General elements of quality management will be reviewed including: what makes a good quality management structure, the use of prospective risk analysis such as FMEA, and the use of incident learning. All of these practices are recommended in society-level documents and are incorporated into the new Practice Accreditation program developed by ASTRO. To be effective, however, these techniques must be practical in a resource-limited environment. This session will therefore focus on practical tools such as the newly-released radiation oncology incident learning system, RO-ILS, supported by AAPM and ASTRO. With these general constructs in mind, a case study will be presented of quality management in an SBRT service. An example FMEA risk assessment will be presented along with incident learning examples including root cause analysis. As the physicist's role as “quality officer” continues to evolve it will be essential to understand and employ the most effective techniques for quality improvement. This session will provide a concrete overview of the fundamentals in quality and safety. Learning Objectives: Recognize the essential elements of a good quality management system in radiotherapy. Understand the value of incident learning and the AAPM/ASTRO ROILS incident learning system. Appreciate failure mode and effects analysis as a risk assessment tool and its use in resource-limited environments. Understand the fundamental principles of good error proofing that extends beyond traditional prescriptive QA measures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-P-22: AAPM Task Group 263 Tackling Standardization of Nomenclature for Radiation Therapy

Purpose: There is growing recognition of need for increased clarity and consistency in the nomenclatures used for body and organ structures, DVH metrics, toxicity, dose and volume units, etc. Standardization has multiple benefits; e.g. facilitating data collection for clinical trials, enabling the pooling of data between institutions, making transfers (i.e. hand-offs) between centers safer, and enabling vendors to define “default” settings. Towards this goal, the American Association of Physicists in Medicine (AAPM) formed a task group (TG263) in July of 2014, operating under the Work Group on Clinical Trials to develop consensus statements. Guiding principles derived from the investigation and example nomenclatures will be presented for public feedback. Methods: We formed a multi-institutional and multi-vendor collaborative group of 39 physicists, physicians and others involved in clinical use and electronic transfer of information. Members include individuals from IROC, NRG, IHE-RO, DICOM WG-7, ASTRO and EORTC groups with overlapping interests to maximize the quality of the consensus and increase the likelihood of adoption. Surveys of group and NRG members were used to define current nomenclatures and requirements. Technical requirements of vendor systems and the proposed DICOM standards were examined. Results: There is a marked degree of inter and intra institutional variation in current approaches, resulting from inter-vendor differences in capabilities, clinic specific conceptualizations and inconsistencies. Using a consensus approach, the group defined optimal formats for the naming of targets and normal structures. A formal objective assessment of 13 existing clinically-used software packages show that all had capabilities to accommodate these recommended nomenclatures. Conclusions: A multi-stakeholder effort is making significant steps forward in developing a standard nomenclature that will work across platforms. Our current working list includes > 550 structures. Outreach efforts are ongoing to ensure broader participation in evaluating and testing the principles as they are developed by TG263.

60 APPLIED LIFE SCIENCES↗

TU-G-201-00: Imaging Equipment Specification and Selection in Radiation Oncology Departments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-01: What Therapy Physicists Need to Know About CT and PET/CT: Terminology and Latest Developments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-02: An MRI Simulator From Proposal to Operation

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-03: Imaging Systems in Radiotherapy: Buying, Installing, and Using

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

SU-D-201-07: A Survey of Radiation Oncology Residents’ Training and Preparedness to Lead Patient Safety Programs in Clinics

Purpose: Safety and quality has garnered increased attention in radiation oncology, and physicians and physicists are ideal leaders of clinical patient safety programs. However, it is not clear whether residency programs incorporate formal patient safety training and adequately equip residents to assume this leadership role. A national survey was conducted to evaluate medical and physics residents’ exposure to safety topics and their confidence with the skills required to lead clinical safety programs. Methods: Radiation oncology residents were identified in collaboration with ARRO and AAPM. The survey was released in February 2016 via email using REDCap. This included questions about exposure to safety topics, confidence leading safety programs, and interest in training opportunities (i.e. workshops). Residents rated their exposure, skills, and confidence on 4 or 5-point scales. Medical and physics residents responses were compared using chi-square tests. Results: Responses were collected from 56 of 248 (22%) physics and 139 of 690 (20%) medical residents. More than two thirds of all residents had no or only informal exposure to incident learning systems (ILS), root cause analysis (RCA), failure mode and effects analysis (FMEA), and the concept of human factors engineering (HFE). Likewise, 63% of residents had not heard of RO-ILS. Response distributions were similar, however more physics residents had formal exposure to FMEA (p<0.0001) and felt they were adequately trained to lead FMEAs in clinic (p<0.001) than medical residents. Only 36% of residents felt their patient safety training was adequate, and 58% felt more training would benefit their education. Conclusion: These results demonstrate that, despite increasing desire for patient safety training, medical and physics residents’ exposure to relevant concepts is low. Physics residents had more exposure to FMEA than medical residents, and were more confident in leading FMEA. This suggests that increasing resident exposure to specific topics may increase their confidence.

60 APPLIED LIFE SCIENCES↗

SU-F-T-215: An Investigation Of Multi-Scanner CT Hounsfield Unit Calibration for Pencil Beam Scanning Proton Therapy Using 3D Gamma Analysis

Purpose: We compare and investigate the dosimetric impacts on pencil beam scanning (PBS) proton treatment plans generated with CT calibration curves from four different CT scanners and one averaged ‘global’ CT calibration curve. Methods: The four CT scanners are located at three different hospital locations within the same health system. CT density calibration curves were collected from these scanners using the same CT calibration phantom and acquisition parameters. Mass density to HU value tables were then commissioned in a commercial treatment planning system. Five disease sites were chosen for dosimetric comparisons at brain, lung, head and neck, adrenal, and prostate. Three types of PBS plans were generated at each treatment site using SFUD, IMPT, and robustness optimized IMPT techniques. 3D dose differences were investigated using 3D Gamma analysis. Results: The CT calibration curves for all four scanners display very similar shapes. Large HU differences were observed at both the high HU and low HU regions of the curves. Large dose differences were generally observed at the distal edges of the beams and they are beam angle dependent. Out of the five treatment sites, lung plans exhibits the most overall range uncertainties and prostate plans have the greatest dose discrepancy. There are no significant differences between the SFUD, IMPT, and the RO-IMPT methods. 3D gamma analysis with 3%, 3 mm criteria showed all plans with greater than 95% passing rate. Two of the scanners with close HU values have negligible dose difference except for lung. Conclusion: Our study shows that there are more than 5% dosimetric differences between different CT calibration curves. PBS treatment plans generated with SFUD, IMPT, and the robustness optimized IMPT has similar sensitivity to the CT density uncertainty. More patient data and tighter gamma criteria based on structure location and size will be used for further investigation.

60 APPLIED LIFE SCIENCES↗

Specific features of technetium mononuclear octahedral oxo complexes: A review

The specific structural features of technetium mononuclear octahedral oxo complexes have been considered. The structures of d{sup 2}-Tc(V) mono- and dioxo complexes, d{sup 2}-Tc(V) pseudodioxo compounds (Tc(V) mono-oxo complexes with an additional multiply bonded RO{sup -} ligand), and d{sup 0}-Tc(VII) trioxo compounds are analyzed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data depth based clustering analysis

Here, this paper proposes a new algorithm for identifying patterns within data, based on data depth. Such a clustering analysis has an enormous potential to discover previously unknown insights from existing data sets. Many clustering algorithms already exist for this purpose. However, most algorithms are not affine invariant. Therefore, they must operate with different parameters after the data sets are rotated, scaled, or translated. Further, most clustering algorithms, based on Euclidean distance, can be sensitive to noises because they have no global perspective. Parameter selection also significantly affects the clustering results of each algorithm. Unlike many existing clustering algorithms, the proposed algorithm, called data depth based clustering analysis (DBCA), is able to detect coherent clusters after the data sets are affine transformed without changing a parameter. It is also robust to noises because using data depth can measure centrality and outlyingness of the underlying data. Further, it can generate relatively stable clusters by varying the parameter. The experimental comparison with the leading state-of-the-art alternatives demonstrates that the proposed algorithm outperforms DBSCAN and HDBSCAN in terms of affine invariance, and exceeds or matches the ro-bustness to noises of DBSCAN or HDBSCAN. The robust-ness to parameter selection is also demonstrated through the case study of clustering twitter data.

58 GEOSCIENCES↗

A Right Transfer Access Control Model of Internet of Things Based on Smart Contract

Sensor nodes play a crucial role in the promotion of development of Internet of Things (IoT). Through this transaction, RO defines access control policies in script form based on ABAC's access control model to grant access right. The identity of all users in the model is identified by address. This paper builds a more flexible right transfer access control model by means of combining the Attribute-Based Access Control model (ABAC) and blockchain technology. Owing to the characteristics of ABAC’s attributes and right association, the massive problems of some sensor nodes can be solved. At the same time, for the sake of addressing the dynamic problems such as node access and right transfer, right transfer contract (TS) and access control contract (CS) are employed on the chain to ensure efficient and safe transmission of rights. To solve on-chain storage problems and ensure transparency of the operation, the idea of Rollup in Ethereum expansion is used to upload the final state of protocol policy and right exchange to the chain. Any user can know the policy and current right transfer status at any time. Finally, comparative and security analysis show that the model presented here can solve IoT devices’ massive and dynamic problems more effectively and it is more secure than the traditional models.

Wang, Jiuru↗