Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Direct Observations of Sub-micropulse Electron-beam Effects from Short-range Wakefields in TESLA-type Superconducting RF Cavities

The preservation of the low emittance of electron beams during transport in the accelerating structures of large facilities is an ongoing challenge. In the cases of the TESLA-type superconducting rf cavities currently used in the European X-ray Free-electron Laser (FEL) and the under construction Linac Coherent Light Source upgrade (LCLS-II), off-axis beam transport may result in emittance dilution due to transverse long-range and short-range wakefields (SRW)*. To investigate such effects, experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility with its unique two-cavity configuration after the photocathode rf gun. We used optical transition radiation (OTR) imaging with a UV-visible synchroscan streak camera to display sub-micropulse y-t effects in the 41-MeV beam. The head-tail transverse kicks within the 11-ps-long micropulses were observed at the 100-micron level for steering off-axis in one cavity and several 100 microns for two cavities. Since the SRW kick angles go inversely with energy, these results may inform the commissioning plans of the LCLS-II injector where beam will be injected at ~1 MeV into a cryomodule.

43 PARTICLE ACCELERATORS↗

BEAM DYNAMICS STUDIES OF 499 MHz SUPERCONDUCTING RF-DIPOLE DEFLECTING CAVITY SYSTEM

A 499 MHz deflecting cavity has been designed as a three-way beam spreader to separate an electron beam into 3 beams. The rf tests carried out on the superconducting rf-dipole cavity have demonstrated that a transverse voltage of 4.2 MV can be achieved with a single cavity. This paper discusses the beam dynamics on a deflecting structure operating in continuous-wave mode with a relativistic beam. The study includes the analysis on emittance growth, energy spread, and change in bunch size including effects due to field non-uniformities.

De Silva, Payagalage Subashini↗

High Powered Tests of Dielectric Loaded High Pressure RF Cavities for Use in Muon Cooling Channels

Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. Alumina of purities ranging from 96 to 99.8% was tested in a high pressure RF test cell at the MuCool Test Area at Fermilab. The results of breakdown studies with pure nitrogen gas, and oxygen-doped nitrogen gas indicate the peak surface electric field on the alumina ranges between 10 and 15 MV/m. How these results affect the design of a prototype cooling channel cavity will be discussed.

43 PARTICLE ACCELERATORS↗

TRANSIENT BEAM LOADING EFFECTS IN RF SYSTEMS IN JLEIC

The pulsed electron bunch trains generated from the Continuous Electron Beam Accelerator Facility (CEBAF) linac to inject into the proposed Jefferson Lab Electron Ion Collider (JLEIC) e-ring will produce transient beam loading effects in the Superconducting Radio Frequency (SRF) systems that, if not mitigated, could cause unacceptably large beam energy deviation in the injection capture, or exceed the energy acceptance of CEBAF’s recirculating arcs. In the electron storage ring, the beam abort or ion clearing gaps or uneven bucket filling can cause large beam phase transients in the (S)RF cavity control systems and even beam loss due to Robinson instability. We have first analysed the beam stability criteria in steady state and estimated the transient effect in Feedforward and Feedback RF controls. Initial analytical models for these effects are shown for the design of the JLEIC e-ring from 3GeV to 12GeV.

Wang, Haipeng↗

Optimization of the cavity heat load and trip rate for CEBAF

The Continuous Electron Beam Accelerator Facility at JLab has 200 RF cavities in the north linac and the south linac respectively after the 12 GeV upgrade. The purpose of this work is to simultaneously optimize the heat load and the trip rate for the cavities and to reconstruct the pareto-optimal front in a timely manner when some of the cavities are turned off. Various optimizers are investigated to find the one with the best efficiency on this specific problem. The derivative information of the heat load is used to effectively create the initial populations. With less than 20 cavities off, the pareto-optimal front can be reestablished within a minute.

Zhang, H.↗

Reduction of Coherent Betatron Oscillations Using RF Electric Fields in the Fermilab Muon g-2 Experiment

The Fermilab Muon g-2 experiment aims to measure the muon anomalous magnetic moment with a 140 parts-per-billion precision to investigate the greater than 3 standard deviation difference between the Standard Model prediction and the previous measurement by the BNL Muon g-2 experiment. The coherent betatron oscillation (CBO) beam effects must be corrected for in the decay-positron time spectra fits used in high precision muon storage ring based anomalous magnetic moment measurements. This MC simulation study indicates that the application of radio frequency (RF) electric fields to the muon storage ring beam can reduce the CBO amplitude by up to a factor of 10, as well to increase the symmetry of the beam phase space. This is achieved by correcting the mismatched oscillation phases between the high and low momentum muon populations by modulating the muon beam betatron oscillation frequencies with off-resonance RF fields.

43 PARTICLE ACCELERATORS↗

Higher-Order-Mode Effects in Tesla-Type Superconducting RF Cavities on Electron Beam Quality

We report the direct observations of the correlation of higher order modes (HOMs) generated by off-axis electron beam steering in TESLA-type SCRF cavities and sub-macropulse beam centroid shifts (with the concomitant effect on averaged beam size and emittance). The experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility using its unique configuration of a PC rf gun injecting beam into two separated 9-cell cavities in series with corrector magnets and beam position monitors (BPMs) located before, between, and after them. The ~100-kHz oscillations with up to 300-μm amplitudes at downstream locations were observed in a 3-MHz micropulse repetition rate beam with charges of 500 and 1000 pC/b, although the effects were much reduced at 100 pC/b. The studies were based on HOM detector circuitry targeting the first and second dipole passbands, rf BPM bunch-by-bunch data, and imaging cameras viewing multi-slit images for emittance assessments at 33 MeV. Initial calculations reproduced a key feature of the phenomena. In principle, these results may be scaled to cryomodule configurations of major accelerator facilities.

43 PARTICLE ACCELERATORS↗

Precision Q0 Measurement of an SRF Cavity with a Digital RF Techniques

Direct measurement of the quality factor of SRF cavity using traditional RF techniques is essential for cavity production and development. Systematic effects of the measurement can contribute significant amounts of error to these measurements if not accounted for. This paper will present measurements taken at Fermilab using a digital RF system to characterize and correct for these systematic effects and directly measure the quality factor versus gradient curve for a single spoke resonator in the Spoke Test Cryostat at Fermilab. These measurements will be compared to traditional calorimetric measurements, and a discussion of improving/extending these techniques to other testing situations will be included.

43 PARTICLE ACCELERATORS↗

Development of Nb3Sn Coatings for Superconducting RF Cavities at Fermilab

Nb3Sn films are a promising alternative material for su-perconducting RF cavities, with proven high quality factors at medium fields and predictions for increased superheating field as well. In this contribution, we de-scribe the latest results from the Fermilab Nb3Sn SRF program. Early experiments have been focused on single cell 1.3 GHz cavities. We briefly review efforts to bring the parameters used in the coating process into a range where they produce uniform surfaces without regions showing signs of excess tin or thin/uncoated areas. We then present the latest cavity results, after modifications to the coating recipe based on feedback from film appear-ance and RF performance. These results show high Q0 at medium fields and a maximum field of ~18 MV/m.

43 PARTICLE ACCELERATORS↗

Magnetron R&Ds for High Efficiency CW RF Sources of Particle Accelerators

A proof of principle experiment carried out at JLab's magnetron R&D test stand has demonstrated a -25dB injection signal to phase lock a 2.45GHz 1.2kW CW magnetron within 2.1 Hz of root mean square deviation (RMSD) value with the optimization of magnetic field trimming of ±25% in order to overcome the frequency pushing of more than 4MHz in the RF power output range of 45-100%. In addition, a test stand for a newly built 1497 MHz, 13kW, CW magnetron prototype is ready for the high power injection test with outcome aimed for the CEBAF klystron replacement. Based on these R&D results, a 915MHz, 2?75kW CW commercial heating type magnetron system is being developed as high efficiency (>80%) RF source to drive an electron linac for industrial applications.

Wang, H.↗

Design of an RF-Dipole Crabbing Cavity System for the Electron-Ion Collider

The Electron-Ion Collider requires several crabbing systems to facilitate head-on collisions between electron and proton beams in increasing the luminosity at the interaction point. One of the critical rf systems is the 197 MHz crabbing system that will be used in crabbing the proton beam. Many factors such as the low operating frequency, large transverse voltage requirement, tight longitudinal and transverse impedance thresholds, and limited beam line space makes the crabbing cavity design challenging. The rf-dipole cavity design is considered as one of the crabbing cavity options for the 197 MHz crabbing system. The cavity is designed including the HOM couplers, FPC and other ancillaries. This paper presents the detailed electromagnetic design, mechanical analysis, and conceptual cryomodule design of the crabbing system.

De Silva, S. U.↗

Observations On Submicropulse Electron-beam Effects From Short-range Wakefields In Tesla-type Superconducting RF Cavities

aExperiments were performed at The Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of short-range wakefields (SRWs) in TESLA-type rf cavities. FAST has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then selected a vertical corrector to steer the beam off axis at an angle into CC1 or CC2. A Hamamatsu synchro-scan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 2 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is consistent wit h a calculated short-range wakefield effect using ASTRA simulations.

43 PARTICLE ACCELERATORS↗

High Efficiency, Low Cost RF Sources for Accelerators and Colliders

Calabazas Creek Research, Inc. (CCR) and its collaborators are developing high efficiency, low cost RF sources. Phase and Amplitude Controlled Magnetrons: CCR, Fermilab, and Communications & Power Industries, LLC (CPI) recently developed a 100 kW, 1.3 GHz magnetron system with amplitude and phase control. The system operated at more than 80% efficiency and demonstrated rapid control of amplitude and phase. Multiple Beam Triodes: CCR, in collaboration with CPI and JP Accelerator Works, Inc., is developing 200 kW, pulsed and CW RF sources from 350 to 700 MHz with projected efficiencies exceeding 80% and cost of $0.50/Watt. Prototype tubes are scheduled for tests in spring 2021. High Efficiency Klystrons:CCR, CPI, and Leidos, Inc. are building a 1.3 GHz, 100 kW klystron operating at 80% efficiency. High power testing is scheduled for summer 2021. Multiple Beam IOTs: CCR and Georgia Tech Research Institute are developing MBIOTs with simplified input coupling and high efficiency. Simulations indicate that 3rd harmonic drive power can increase the efficiency 8-10 %. The program is developing a prototype tube to produce 200 kW peak, 100 kW average power at 704 MHz.

43 PARTICLE ACCELERATORS↗

Multipacting analysis of the SNS drift tube linac (DTL) RF vacuum window using Spark3d

An ongoing study at the Spallation Neutron Source (SNS) seeks to better understand and address potential multipacting issues associated with the Drift Tube Linac (DTL) RF vacuum windows. An analysis of several failed operational windows showed indications of excessive RF heating on the TiN-coated alumina ceramics. Coupled with vacuum bursts and arcing during conditioning and/or operational periods, these problems have been attributed to electron activity likely caused by multipacting. The status of the study, 3-D electromagnetic simulation results, mitigating techniques and a future experimental plan for studying multipacting in the SNS DTL vacuum windows are presented.

Toby, George↗

Dual-RF Phase Control for Adiabatic Energy Ramping in the EIC Rapid Cycling Synchrotron

The Electron-Ion Collider (EIC) Rapid Cycling Synchrotron (RCS) accelerates electrons from 750 MeV to 10 GeV over approximately 64.7 ms. While the baseline design simultaneously ramps both RF voltage and phase, this study evaluates an alternative where RF cavities are divided into two groups, each operating at a fixed 6.5 MV, with the effective voltage synthesized through phase control. In the symmetric scheme (Option A), both groups vary symmetrically about the synchronous phase to provide exact matching of energy gain and synchrotron tune throughout the ramp. Conversely, the asymmetric scheme (Option B) pins one group at the final operating phase while the other varies to supply the required energy gain. The feasibility of Option B is determined by the adiabaticity of the resulting synchrotron tune evolution, with ramp profiles, phase trajectories, and adiabaticity metrics analyzed for both implementations.

Gamage, B. [Thomas Jefferson National Accelerator ↗

Automated RF Phase Adjustment for Beam Stabilization in the Fermilab Linac

The Fermilab Linac experiences longitudinal beam phase drift, leading to increased particle loss, conventionally corrected through labor-intensive manual RF adjustments. This project explores machine learning-based automation for drift correction, employing a prototype-based classification approach. Our model utilizes a 34-dimensional feature set (RF settings and BPM readings) and leverages a 7x27 response matrix for system modeling. To overcome limited real-world data, we generate synthetic data, enhancing model training and generalizability. Custom loss functions, including a surrogate energy-consistent loss and a temporal smoothness constraint, ensure physically plausible drift predictions. The goal is a robust system for autonomous phase adjustments, ensuring stable beam acceleration and reduced manual intervention.

Chichili, R. R. [Illinois U., Chicago]↗

Temperature, rf field, and frequency dependence performance evaluation of superconducting niobium half-wave coaxial cavity

Recent advancement in superconducting radio frequency cavity processing techniques, with diffusion of impurities within the RF penetration depth, resulted in high quality factor with increase in quality factor with increasing accelerating gradient. The increase in quality factor is the result of a decrease in the surface resistance as a result of nonmagnetic impurities doping and change in electronic density of states. The fundamental understanding of the dependence of surface resistance on frequency and surface preparation is still an active area of research. Here, we present the result of RF measurements of the TEM modes in a coaxial half-wave niobium cavity resonating at frequencies between 0.3 ? 1.3 GHz. The temperature dependence of the surface resistance was measured between 4.2 K and 1.6 K. The field dependence of the surface resistance was measured at 2.0 K. The baseline measurements were made after standard surface preparation by buffered chemical polishing.

Dhakal, P.↗