Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Development of ultralow-background cryogenic calorimeters for the measurement of surface α contamination

Next-generation experiments searching for rare events must satisfy increasingly stringent requirements on the bulk and surface radioactive contamination of their active and structural materials. The measurement of surface contamination is particularly challenging, as no existing technology is capable of separately measuring parts of the 232 Th and 238 U decay chains that are commonly found to be out of secular equilibrium. We will present the results obtained with a detector prototype consisting of 8 silicon wafers of 150mm diameter instrumented as bolometers and operated in a low-background dilution refrigerator at the Gran Sasso Underground Laboratory of INFN, Italy. Furthermore, the prototype was characterized by a baseline energy resolution of few keV and a background <100nBq/cm 2 in the full range of α energies, obtained with simple procedures for cleaning of all employed materials and no specific measures to prevent recontamination. Such performance, together with the modularity of the detector design, demonstrate the possibility to realize an alpha detector capable of separately measuring all alpha emitters of the 232 Th and 238 U chains, possibly reaching a sensitivity of few nBq/cm 2 .

07 ISOTOPE AND RADIATION SOURCES↗

Photonuclear production of 47 Ca for 47 Ca/ 47 Sc generator from natural CaCO 3 targets

Here this work investigated the indirect production of 47 Sc from natural Ca targets via 48 Ca(γ,n) 47 Ca → 47 Sc +β - +$\bar{\nu}_e$ with incident electron energies of 30, 35, and 40 MeV. The 47 Ca production yields were simulated using the PHITS Monte Carlo simulation code and compared to experimental data. The simulated production rates for all three irradiations are in good agreement with experimental data within uncertainties. As a demonstration of the 47 Ca/ 47 Sc generator system, one of the irradiated CaCO 3 targets was dissolved in nitric acid, and 47 Sc was isolated from the target material using commercially available Eichrom DGA resin. The 47 Sc was allowed to grow in, and the purification process was repeated with promising 47 Sc and Ca recovery yields.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of the 70 Ge( d , n ) 71 As cross section from 2.1 MeV to 10 MeV

This work reports experimental 70 Ge(d,n) 71 As cross sections producing Arsenic-71 (t 1/2 = 65.3 h, 28% β + ), a potentially useful diagnostic radionuclide. Target stacks containing two nat Ge foils, a nat Ni monitor foil, and an Al degrader were irradiated with 5.5–10 MeV deuterons using an FN Tandem Van de Graaff accelerator. 71 As and 61 Cu, 56 Co, and 58 Co (from nat Ni(d,x)) were quantified in the foils by high purity germanium gamma spectrometry. Furthermore, the measured cross sections are larger than previously reported and suitable for producing preclinical quantities of diagnostic radiopharmaceuticals.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of measurement techniques and sorption of radium-226 in low and high salinity aqueous samples

Human activities have the potential to redistribute radium (Ra) in the marine environment in a manner that may necessitate monitoring or management of subsequent human or environmental exposures. There is therefore a need to identify accurate and accessible techniques for Ra measurement in high salinity samples and to describe the distribution of Ra in estuarine and marine environments, but most efforts in these areas have focused on low salinity matrices. In addition, rapid and reliable measurements are crucial for time-sensitive samples such as short-lived isotopes or emergency situations. The objective of this study is to describe the limits of detection, cost, and relative ease for measurement of Ra in both low and high salinity aqueous samples via three analytical methods: liquid scintillation counting (LSC), high purity germanium (HPGe) gamma spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS). To contextualize these measurements for real-world scenarios, the partitioning of 226 Ra to substrates relevant to the marine environment was also characterized. Although HPGe detection with solid phase extraction had the lowest limit of detection for low salinity samples (0.27 Bq L −1 ), poor 226 Ra recovery for high salinity samples and high materials costs make this method prohibitive for many users. Limits of detection for high salinity samples were lower for LSC (1.28 Bq L −1 ) than for ICP-MS without dilution (11.4 Bq L −1 ), but significant and unexpected degradation of the high salinity LSC standards was observed after six months. Furthermore, our preferred measurement method for high salinity Ra samples is ICP-MS with sample dilution as necessary to reduce matrix effects.

07 ISOTOPE AND RADIATION SOURCES↗

Cyclotron production of a 204 Bi/ 204m Pb generator by 24 MeV proton irradiation of natural Pb foil targets

This work focuses on the formation of a generator of 204 Bi/ 204m Pb for future applications in perturbed angular correlation spectroscopy and biological radiotracing with lead and bismuth isotopes. Generators were formed from the irradiation of natural Pb targets with 24 MeV protons producing 203,204,205,206,207 Bi that were rapidly dissolved in 3 M HNO 3 and 30 % H 2 O 2 and exchanged into a 0.1 M HCl matrix. Use of 100 mg anion exchange resin (AG 1-x8) allowed 203,204m Pb to be eluted in 600 μL of 0.1 M HCl. Furthermore, the longer-lived 205,206 Bi were eluted in 5 mL or 3 mL of either 0.25 M sodium acetate buffer pH 4.4 or 1.0 M H 2 SO 4 . Initial radiolabeling was conducted with eluted 206 Bi using DTPA and DOTA and 203 Pb using TCMC-Azide.

07 ISOTOPE AND RADIATION SOURCES↗

Processing iridium foil targets for the production of radioplatinum isotopes

Dissolving noble metals remains challenging because of their high reduction potentials and tendency to passivate as oxides. This barrier is acute for iridium metal targets used to produce platinum radioisotopes, where post-irradiation processing is costly and hazardous with conventional routes. Here, we report a rapid alkali-fusion method that converts Ir metal directly into chloride media compatible with downstream separations. In the process, an Ir foil is fused with Na 2 O 2 and KCl at temperatures above the KCl melting point; the molten salt enhances heat transfer and facilitates O 2− /Na + transport to the Ir surface, overcoming Ir's oxidation resistance. The fused cake is then cooled and leached in 10 M HCl, yielding Ir in solution without specialized microwave digestion or HF. Pt separation from bulk Ir was evaluated using extraction-chromatography resins. A newly formulated ionic-liquid resin containing Cyphos IL 104 (E104) was compared with two commercial resins (TrisKem TK200 and TK201). All resins achieved >90 % Ir recovery. Pt co-recovery depended on resin chemistry: TK200 recovered 85.9 % Pt, TK201 recovered 54.1 % Pt, and E104 recovered 72.9 % Pt. This study introduces a fast, scalable dissolution route for solid Ir targets and demonstrates resin choices that tune Ir/Pt separation, lowering the barrier to routine production and purification of Pt radioisotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a SnO 2 -based 44 Ti/ 44 Sc generator for medical applications

Towards application of 44 Sc for diagnostic nuclear medicine, a 44 Ti/ 44 Sc generator based on an inorganic resin has been evaluated. Unlike other radionuclide generators used for medical applications, the long-term retention of the parent 44 Ti is vital due to its long half life. In this work, tin dioxide (SnO 2 ), a robust inorganic-based resin, has been synthesized and used as the stationary phase for a 44 Ti/ 44 Sc generator. The sorption behavior of 44 Ti/ 44 Sc was tested on SnO 2 with varying acids, concentrations, and times. Preliminary batch study results showed >88 % 44 Ti retention to the resin at lower acid concentrations (0.05 M HNO 3 and 0.05 M HCl). A pilot generator was evaluated for a year, demonstrating 85.3 ± 2.8 % 44 Sc elution yields and 0.71 ± 0.14 % 44 Ti breakthrough in 5 M HNO 3 . Based on capacity studies, a 7.4 MBq (200 µCi) upscaled generator system was constructed for further evaluation of the SnO 2 resin stability and the efficacy of the eluted 44 Sc for radiolabeling. 44 Sc could be regularly eluted from this generator in 5 M HNO 3 with an overall average radiochemical yield 84.7 ± 9.5 %. Post-elution processing of the 44 Sc with DGA-normal resin removed all 44 Ti present and allowed for high 44 Sc-DOTA labeling yields of 94.2 ± 0.5 %. Overall, SnO 2 has been shown to be a viable material for a 44 Ti/ 44 Sc generator.

07 ISOTOPE AND RADIATION SOURCES↗

A window into atmospheric escape on early Mars provided by argon isotopes in a Martian meteorite

Novel analytical approaches to determining the trapped 38 Ar/ 36 Ar ratio of gases contained within Martian meteorites are presented and applied to the Martian regolith breccia Northwest Africa (NWA) 7034 and paired stone NWA 11220. The resulting data indicate that extensive mass-dependent fractionation of atmospheric Ar may have occurred within 150 million years of planetary formation, ostensibly as a result of diffusion-limited hydrodynamic escape. The inferred fractional loss of Ar and lighter atmospheric constituents exceeds 50%. In conclusion, these data suggest that volatiles derived from planetary outgassing and/or impactors may dominate the present abundance of atmospheric Ar.

07 ISOTOPE AND RADIATION SOURCES↗

Development of experimental and computational frameworks to predict subcooled flow boiling in the LANL Isotope Production Facility

Cooling is crucial to maintain the integrity of target systems in isotope production facilities. At Los Alamos National Laboratory (LANL)’s Isotope Production Facility (IPF), multiple encapsulated targets are stacked and irradiated in tandem with a 100 MeV, ~250μA proton beam. To facilitate effective heat removal, these stacked targets are separated and cooled via a series of water channels. At these beam currents, this high-energy proton beam heats the target system, likely initiating subcooled flow boiling in the cooling channels. However, in-beam monitoring of the IPF target system is not possible due to the extreme radiation environment, and the necessarily significant shielding. To better understand high-power target performance, we developed ex-situ experimental and computational frameworks to predict the behavior of subcooled flow boiling at IPF. Subcooled flow boiling experiments on Inconel 625 samples under IPF conditions (2 bar pressure, 10 GPM flow rate (i.e., 2249 kg/m 2 /s), 85 K subcooling) revealed that IPF's average operating power is at the early stage of boiling with a heat transfer coefficient of 48,000 W/m 2 /s. The proposed modeling framework enables us to predict a complete boiling curve, i.e., single-phase heat transfer, onset of nucleate boiling, two-phase heat transfer, and critical heat flux (CHF), with specification of input boiling parameters up to intermediate heat flux levels. The estimated CHF under IPF conditions is 5.2 MW/m 2 . Experimental data under reduced conditions (2 bar pressure, 1.5 GPM flow rate (i.e., 337 kg/m 2 /s), 45 K subcooling) served as validation cases for the computational modeling. This computational model can be further extended to more complicated systems replicating the real IPF configuration, for instance, to study void distribution as a function of the incident proton beam profile and coolant velocity profile of multiple cooling channels. Finally, the proposed experimental and computational frameworks provide a means to better understand cooling systems in the isotope production facilities at different accelerators, where in-beam monitoring of the cooling process is not available.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of Dosimetric Differences in Strut-Adjusted Volume Implant Treatment Plans Calculated With TG-43 Formalism and a Model-Based Dose Calculation Algorithm

To comprehensively characterize dosimetric differences between calculations with a commercial model-based dose calculation algorithm (MBDCA) and the TG-43 formalism in application to accelerated partial breast irradiation (APBI) with the strut-adjusted volume implant (SAVI) applicator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Bison fission product species conservation under TRISO reactor conditions

When assessing the reliability and predictive capabilities of a simulation tool, code verification is used to ensure that the implemented numerical algorithm is a faithful representation of its underlying mathematical model, including partial differential or integral equations, initial and boundary conditions, and auxiliary relationships. During this process, numerical results in a discrete solution are compared to the analytical solution of the mathematical model. Here, in this paper, the code verification process is applied to one-dimensional spatiotemporal problems that exercise partial differential equation governing the conservation of fission product species (or mass diffusion). Numerical experiments were performed in the Bison fuel performance code to evaluate its predictive capability under various TRISO reactor conditions such as base irradiation and safety heating test conditions for either short- or long-lived fission product species, as well as a case concerning evaporation from the outer surface of a particle. The code predictions were compared with the expected exact results obtained from the analytical expressions, and the fact that they demonstrate the correct analytical behavior provides strong evidence of proper numerical algorithm implementation.

07 ISOTOPE AND RADIATION SOURCES↗

Identification of uranium oxidation states using oxygen K-edge scanning transmission X-ray microscopy

The field of nuclear forensics is growing in importance, and the increasing capabilities at synchrotron radiation light sources enable non-destructive characterization of oxide particles with better spatial, compositional, and oxidation state speciation resolution than ever before. Here, uranium oxide particles derived from multiple wet chemical processing methods were examined using a scanning transmission X-ray microscope (STXM), and a weakly-supervised method was developed to automatically analyze the collected data. Multiple uranium oxidation states were observed and quantified within and between samples, yielding information about differences between particles produced via the various processing routes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing secondary neutrons at BLIP for isotope production applications

Fast secondary neutrons created at the Brookhaven Linac Isotope Producer (BLIP) facility following proton irradiation were characterized by the foil activation technique and compared with FLUKA Monte Carlo simulations. The FLUKA-simulated neutron flux was spectrally adjusted following the maximum entropy formalism using the International Reactor Dosimetry and Fusion File (IRDFF-II), with predictions agreeing with experimental measurements to within 9 % following the adjustment procedure. Here, a multitude of degrader configurations were simulated to assess the feasibility of improving the fast (E n > 20 MeV) secondary neutron yield at the proposed neutron target position (“N-slot”). A configuration where the N-slot is closest to the proton degrader produced the highest fast neutron yield, with tungsten degraders achieving the best performance. Assuming the optimized target-degrader configuration proposed in this work, we discuss potential isotope production opportunities with secondary neutrons. In most cases the yields are in the order of several mCi.

07 ISOTOPE AND RADIATION SOURCES↗

Radioarsenic: A promising theragnostic candidate for nuclear medicine

Molecular imaging is a non-invasive process that enable the visualization, characterization, and quantitation of biological processes at the molecular and cellular level. With the emergence of theragnostic agents to diagnose and treat disease for personalized medicine there is a growing need for matched pairs of isotopes. Matched pairs offer the unique opportunity to obtain patient specific information from SPECT or PET diagnostic studies to quantitate in vivo function or receptor density to inform and tailor therapeutic treatment. There are several isotopes of arsenic that have emissions suitable for either or both diagnostic imaging and radiotherapy. Their half-lives are long enough to pair them with peptides and antibodies which take longer to reach maximum uptake to facilitate improved patient pharmacokinetics and dosimetry then can be obtained with shorter lived radionuclides. Arsenic-72 even offers availability from a generator that can be shipped to remote sites and thus enhances availability. Arsenic has a long history as a diagnostic agent, but until recently has suffered from limited availability, lack of suitable chelators, and concerns about toxicity have inhibited its use in nuclear medicine. However, new production methods and novel chelators are coming online and the use of radioarsenic in the pico and nanomolar scale is well below the limits associated with toxicity. This manuscript will review the production routes, separation chemistry, radiolabeling techniques and in vitro/in vivo studies of three medically relevant isotopes of arsenic (arsenic-74, arsenic-72, and arsenic-77).

07 ISOTOPE AND RADIATION SOURCES↗

Development and biodistribution studies of 77 As-labeled trithiol RM2 bioconjugates for prostate cancer: Comparison of [ 77 As]As-trithiol-Ser-Ser-RM2 vs. [ 77 As]As-trithiol-Glu-Ser-RM2

Recent progress with the production of 72 As (2.49 Mev β + max (64%), 3.33 Mev β + max (16%), 834 keV (81%), t 1/2 : 26 h) and 77 As (0.683 Mev β- max (97%), 239 keV (1.59%), t 1/2 : 38.8 h) has facilitated their evaluation as a potential “theranostic pair” for PET imaging and radiotherapy. Our 3 rd generation trithiol chelate with two carboxylic acid groups was further developed as a bifunctional chelate for radioarsenic. The As complex with the trithiol chelate was synthesized and characterized. No carrier added (nca) [ 77 As][H 2 AsO 4 - ] was used for radiolabeling studies. Here, the trithiol chelate was conjugated to the RM2 peptide (DPhe-Gln-Trp-Ala-VaI-Gly-His-Sta-Leu-NH 2 ) via solid phase peptide synthesis with two different linkers, Ser-Ser and Glu-Ser. The trithiol chelate and its RM2 bioconjugates were radiolabeled with nca 77 As, and the RM2 bioconjugates were compared in initial biodistribution studies. The As diacid trithiol complex was characterized by 1 H NMR, 13 C NMR and HR-ESI-MS. The trithiol-RM2 precursor and As trithiol bioconjugates were characterized by HR-ESI-MS and/or LC-ESI-MS. Radiolabeling of the RM2 bioconjugates with 77 As resulted in over 85% radiochemical yield for [ 77 As]As-trithiol-Ser-Ser-RM2 ([ 77 As]8) and 90% for [ 77 As]As-trithiol-Glu-Ser-RM2 ([ 77 As]9). Both radiotracers demonstrated excellent in vitro stability (≥ 90% remaining intact through 24 h in PBS buffer) and were more hydrophilic than previous analogues based on log D 7.4 values. Biodistribution results of the two radiotracers in healthy CF-1 male mice demonstrated blockable pancreatic uptake at 1 h (82% for ([ 77 As]8 and 78% for [ 77 As]9) indicating specific gastrin-releasing peptide receptor (GRPR) uptake. The primary route of excretion was through the gastrointestinal system for both radiotracers. A new trithiol chelate with improved hydrophilicity was successfully conjugated to the RM2 peptide via two linkers, and high radiolabeling yield with nca 77 As was achieved. In vivo biodistribution studies with both radiotracers demonstrated blockable pancreatic uptake suggestive of specific receptor uptake.

07 ISOTOPE AND RADIATION SOURCES↗