Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Used nuclear fuel dry storage cask materials monitoring system: a proof of concept to deploy retrieve monitoring equipment - 15504

The cask materials monitoring system is a proof-of-concept to deploy and retrieve monitoring equipment. The system is an airlock-type system that is bolted to the cask fill/drain port. It consists of the following major components: (1) a monitoring module that contains the equipment for monitoring the cask environment, (2) a sliding shield plug that provides radiation shielding throughout the deployment and retrieval of the monitoring equipment module, (3) a primary seal flange that is permanently installed on the cask that provides cask boundary confinement, and (4) a containment tube that provides the airlock function providing cask confinement when the primary seal is broken. In this proof-of-concept development, corrosion coupons were selected as the monitoring equipment for deployment into a spent nuclear fuel cask. However, the system has the potential for a variety of uses. The integration of a camera deployment system into the cask materials monitoring system will permit inspection of used nuclear fuel while maintaining cask atmosphere. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large Cask, Small Building, AREVA's Safe MLLW Disposal Solution Despite Facility Limitations - 16295

In order to begin decommissioning of a 1950's research reactor, Class C Mixed Low Level Waste (MLLW) had to be removed from the facility and disposed of. The AREVA TN RAM cask, designed and licensed for shipping Type B waste packages, was chosen as the most appropriate shipping solution. Due to the building layout, crane capacity and pool size, the standard TN RAM cask loading process could not be utilized. Unique solutions and approaches had to be developed to complete the project. AREVA designed a smaller liner insert that would house the four MLLW components in a single waste package to solve the problems related to crane capacity and physical pool dimensions. AREVA also designed and fabricated a shield bell to provide radiation shielding while moving the liner insert from the reactor pool to the cask that was staged adjacent to the reactor pool. The AREVA team worked with the disposal facility to cover requirements for disposal of Class B MLLW. This included designing spacers filled with inert material to fulfill the requirement for maximum 10% void space in the waste package. This disposal method for Class C waste met the requirements of macro-encapsulation. Therefore, no additional treatment action was required when disposing of Class C MLLW. AREVA's solution provides a model for disposing MLLW requiring macro-encapsulation in a single waste package. This solution also provides a model for how to adapt large shipping casks and liners to smaller aging commercial, DOE or research facilities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of ADVANTG Simulations to Simple Shielding Measurements - Paper 36

Monte Carlo (MC) radiation transport simulations, like those performed using Monte Carlo N-Particle (MCNP), can be highly accurate but require time to reduce the statistical uncertainties in the calculated detector response(s). Many different 'variance reduction' techniques devised over the years increase the efficiency of MC calculations, but these methods can be more art than science. Many of these methods are problem specific or require careful tuning of parameters for good performance. One of the best variance reduction methods, in terms of both reliable performance increases and ease of use, is the use of weight windows. Weight windows are derived from an importance map in space and energy that allows the transport code to focus more simulation time on particles that have a higher likelihood of being important to the final detector response. Less time is spent simulating particles that have little chance of making a contribution to the detector response. MCNP already includes the abilities to generate and use weight windows. Unfortunately, generating weight windows can take a very long time, perhaps longer than the original problem. Oak Ridge National Laboratory has led the development of hybrid methods using a discrete ordinates adjoint calculation to quickly develop an importance map (weight windows) for use in a Monte Carlo code. The Consistent Adjoint Driven Importance Sampling (CADIS) method uses an adjoint calculation to develop both an importance map and a biased source distribution that work together. This method is reasonably automatic, is easy to use, and has been implemented in the Automated Variance reduction Generator (ADVANTG) package that works with MCNP5. ADVANTG reads an MCNP input file and a small amount of extra user information and then runs an adjoint deterministic calculation using Denovo. The importance map and biased source distribution derived from the CADIS method can then be incorporated back into the original MCNP input file to enhance the figure-of-merit (FOM) of the calculation. The FOM is a measure of the efficiency of the calculation using the amount of run time and corresponding level of statistical uncertainty in the detector result. ADVANTG-enhanced MCNP input files have been shown to increase the FOM of many types of problems, obtaining the same level of statistical uncertainty in a shorter time compared to standard MCNP. ADVANTG can also generate variance reduction parameters (importance map and biased source) using the Forward-Weighted CADIS (FW-CADIS) method for optimizing mesh tallies. The CADIS method creates variance reduction parameters that optimize a tally's total quantity (flux, dose rate, interaction rate, etc.) and will not generally increase performance for all parts of a segmented tally. To optimize a segmented tally, the FW-CADIS method uses two discrete ordinates calculations to make variance reduction parameters that help compute a segmented tally with uniform relative uncertainties in each bin. This report will demonstrate that using ADVANTG for neutron and photon radiation shielding problems will (1) preserve the standard MCNP results and (2) obtain those results either with less statistical uncertainty or in shorter times than the standard MCNP calculation. The four demonstration problems in this report are based on simple neutron or photon transmission measurements through different materials. All of the problems here used the CADIS method and still saw improvement across the flux tallies segmented by particle energy. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Shield Boosts Silicon-Growth Rate

Radiation shield permits faster growth--by 20 percent--of singlecrystal silicon from molten silicon by producting sharper thermal gradients near growth front.

Lane, R. L.↗

Shielding of Transportable Fission Batteries

This is a generic presentation on the basics of radiation shielding as well as potential issues and possible solutions facing shielding fission batteries. It is to be presented at the Lightweight Materials Workshop on Nov 8 & 9 in EROB-159.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The use of directional interstitial sources to improve dosimetry in breast brachytherapy

The purposes of this study were to investigate the feasibility of improving dosimetry with temporary low-dose-rate (LDR) multicatheter breast implants using directional {sup 125}I (iodine) interstitial sources and to provide a comparison of a patient treatment plan to that achieved by conventional high-dose-rate (HDR) interstitial breast brachytherapy. A novel {sup 125}I source emitting radiation in a specified direction has been developed. The directional sources contain an internal radiation shield that greatly reduces the intensity of radiation in the shielded direction. The sources have a similar dose distribution to conventional nondirectional sources on the unshielded side. The treatment plan for a patient treated with HDR interstitial brachytherapy with {sup 192}Ir (iridium) was compared with a directional {sup 125}I treatment plan using the same data set. Several dosimetric parameters are compared including target volume coverage, volume receiving 50%, 100%, and 150% of the prescription dose (V50, V100, and V150, respectively), dose homogeneity index (DHI), and the skin surface areas receiving 30%, 50%, and 80% of the prescription dose (S30, S50, and S80, respectively). The HDR and LDR prescription doses were 34 Gy in ten fractions delivered over five days and 45 Gy in 108 h, respectively. Similar and excellent target volume coverage was achieved by both directional LDR and HDR plans (99.2% and 97.5%, respectively). For a 170 cm{sup 3} target volume, the dosimetric parameters were similar for LDR and HDR: DHI was 0.82 in both cases, V100 was 214.4 cm{sup 3} and 225.7 cm{sup 3}, and V150 was 39.1 cm{sup 3} and 40.4 cm{sup 3}, respectively. However, with directional LDR, significant reductions in skin dose were achieved: S30 was reduced from 100.6 to 62.5 cm{sup 2}, S50 from 50.6 to 16.1 cm{sup 2}, and S80 from 2 cm{sup 2} to zero. The reduction in V50 for the whole breast was more than 100 cm{sup 3} (386.1 cm{sup 3} for LDR versus 489.2 cm{sup 3} for HDR). In this case study, compared with HDR, directional interstitial LDR {sup 125}I sources allow similar dose coverage to the subcutaneous target volume while lowering the skin dose due to a more conformal dose distribution and quicker falloff beyond the target. The improved dose distribution provided by directional interstitial brachytherapy might enable partial breast treatment to tumors closer to the skin or chest wall or in relatively small breasts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Light Water Reactor Sustainability Program: Survey of Models for Concrete Degradation

Concrete is widely used in the construction of nuclear facilities because of its structural strength and its ability to shield radiation. The use of concrete in nuclear facilities for containment and shielding of radiation and radioactive materials has made its performance crucial for the safe operation of the facility. As such, when life extension is considered for nuclear power plants, it is critical to have predictive tools to address concerns related to aging processes of concrete structures and the capacity of structures subjected to age-related degradation. The goal of this report is to review and document the main aging mechanisms of concern for concrete structures in nuclear power plants (NPPs) and the models used in simulations of concrete aging and structural response of degraded concrete structures. This is in preparation for future work to develop and apply models for aging processes and response of aged NPP concrete structures in the Grizzly code. To that end, this report also provides recommendations for developing more robust predictive models for aging effects of performance of concrete.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Lewis proton shielding code

Fortran IV computer program for calculation of primary proton and secondary proton and neutron particle spectra and dose behind multilayer radiation shielding

RADIATION SHIELDING↗

GRIZZLY Model of Multi-Reactive Species Diffusion, Moisture/Heat Transfer and Alkali-Silica Reaction for Simulating Concrete Aging and Degradation

Concrete is widely used in the construction of nuclear facilities because of its structural strength and its ability to shield radiation. The use of concrete in nuclear power plants for containment and shielding of radiation and radioactive materials has made its performance crucial for the safe operation of the facility. As such, when life extension is considered for nuclear power plants, it is critical to have accurate and reliable predictive tools to address concerns related to various aging processes of concrete structures and the capacity of structures subjected to age-related degradation. The goal of this report is to document the progress of the development and implementation of a fully coupled thermo-hydro-mechanical-chemical model in GRIZZLY code with the ultimate goal to reliably simulate and predict long-term performance and response of aged NPP concrete structures subjected to a number of aging mechanisms including external chemical attacks and volume-changing chemical reactions within concrete structures induced by alkali-silica reactions and long-term exposure to irradiation. Based on a number of survey reports of concrete aging mechanisms relevant to nuclear power plants and recommendations from researchers in concrete community, we’ve implemented three modules during FY15 in GRIZZLY code, (1) multi-species reactive diffusion model within cement materials; (2) coupled moisture and heat transfer model in concrete; and (3) anisotropic, stress-dependent, alkali-silica reaction induced swelling model. The multi-species reactive diffusion model was implemented with the objective to model aging of concrete structures subjected to aggressive external chemical attacks (e.g., chloride attack, sulfate attack, etc.). It considers multiple processes relevant to external chemical attacks such as diffusion of ions in aqueous phase within pore spaces, equilibrium chemical speciation reactions and kinetic mineral dissolution/precipitation. The moisture/heat transfer module was implemented to simulate long-term spatial and temporal evolutions of the moisture and temperature fields within concrete structures at both room and elevated temperatures. The ASR swelling model implemented in GRIZZLY code can simulate anisotropic expansions of ASR gel under either uniaxial, biaxial and triaxial stress states, and can be run simultaneously with the moisture/heat transfer model and coupled with various elastic/inelastic solid mechanics models that were implemented in GRIZZLY code previously. This report provides detailed descriptions of the governing equations, constitutive equations and numerical algorithms of the three modules implemented in GRIZZLY during FY15, simulation results of example problems and model validation results by comparing simulations with available experimental data reported in the literature. The close match between the experiments and simulations clearly demonstrate the potential of GRIZZLY code for reliable evaluation and prediction of long-term performance and response of aged concrete structures in nuclear power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Shielding Considerations for CubeSat Structures During Solar Maximum

The purpose of this lessons learned is to communicate the utility of shielding in small spacecraft planning for the support of mission assurance and reliability. Numerous SmallSats have been flying in polar low earth orbit for scientific, communications, technology demonstrations, and imaging with academic, commercial, and government interests. Shielding has been part of mission assurance and reliability from the advent of long duration spacecraft missions. The Shields-1 CubeSat has been operating in polar low earth orbit since 16 December 2018 with atomic number (Z)-grade radiation shielding and demonstrates shielding effectiveness. Shields-1 has collected a representative example of solar minimum data in 2019 with 8 Teledyne dosimeters over varying shielding effectiveness. It serves as current experimental data and has been compared with NOVICE Shielding estimates using the AP8 –AE8 trapped radiation model with the Shields-1 CAD and generic CubeSat 3 unit (U) models. Using NOVICE model radiation analysis coding, the shielding effectiveness's, based on a generic CubeSat 3U structure with 4 electronic boards, were estimated for aluminum wall thicknesses ranging from 0.204 cmto4.44 cm (0.550 g/cm2–12.0 g/cm2) thick aluminum. For modeled polar orbiting spacecraft, solar maximum total ionizing dose (TID)increases by nearly a magnitude for thin-walled aluminum 0.550g/cm2-0.686 g/cm2(0.204 cm –0.254 cm) typical CubeSat structures. The shielding effectiveness by NOVICE Sigma estimates, which is a shielding sphere approximation around a detector, showed a linear relationship with wall thickness, which increased over the wall thickness by a ratio of 1.43 determined by linear regression analysis. Using NOVICE Adjoint Monte-Carlo Modeling of solar minimum and solar maximum with the inclusion of a worst-case solar particle event over a one year mission without geomagnetic shielding, the TID for minimum and maximum conditions for a generic 3U with a wall thickness of 0.254 cm is 158 RAD and 1540 RAD, respectively. The modeled total solar maximum TID is over estimated, because at low orbital latitudes a spacecraft will have shielding from Earth's magnetic field. However, TID will still be significant at high latitudes over the poles, where a spacecraft is exposed in a solar particle event. In contrast, to a thin walled generic 3U CubeSat, Shields-1 electronics enclosure has a shielding effectiveness of 21.3 g/cm2from NOVICE Sigma modeling and is expected to show reduced total ionizing dose increases during the present active Solar Cycle 25 period. Because solar particle events during solar maximum increase TID on electronic parts with thin-walled shielding in short periods of time, it is a mission assurance and reliability consideration on the spacecraft’s mission value versus adding shielding for risk reduction of premature spacecraft or instrument payload loss. Since the volumes of many instruments and system electronics have reduced with small spacecraft, shielding material costs and weight penalties have diminished. A small spacecraft project budget and schedule may limit traditional radiation-hardened part use and radiation testing requirements, where shielding can contribute to mission assurance and reliability with reduced costs.

Shields-1↗

Shielding Considerations for CubeSat Structures During Solar Maximum

The purpose of this lessons learned paper is to communicate the utility of shielding in small spacecraft planning for the support of mission assurance and reliability. Numerous SmallSats have been flying in polar low Earth orbit for science, communications, technology demonstrations, and imaging with academic, commercial, and government interests. Shielding has been part of mission assurance and reliability from the advent of long duration spacecraft missions. The Shields-1 CubeSat has been operating in polar low Earth orbit since 16 December 2018 with atomic number (Z)-grade radiation shielding and demonstrates shielding effectiveness. Shields-1 has collected a representative example of solar minimum data in 2019 with eight Teledyne µDosimeters over varying shielding effectivenesses. It serves as current experimental data and has been compared with NOVICE Shielding estimates using the AP8 – AE8 trapped radiation model with the Shields-1 CAD and generic CubeSat three unit (3U) models. Using NOVICE model radiation analysis coding, the shielding effectivenesses, based on a generic CubeSat 3U structure with four electronic boards, were estimated for aluminum wall thicknesses ranging from 0.204 cm to 4.44 cm (0.550 g/cm 2 to 12.0 g/cm 2 ). For modeled polar orbiting spacecraft, solar maximum total ionizing dose (TID) increases by nearly a magnitude for thin-walled aluminum 0.550-g/cm 2 - 0.686-g/cm 2 (0.204-cm – 0.254-cm) typical CubeSat structures. The shielding effectiveness estimated by NOVICE Sigma, which is a shielding sphere approximation around a detector, showed a linear relationship with wall thickness, which increased over the wall thickness by a ratio of 1.43 determined by linear regression analysis. Using NOVICE Adjoint Monte-Carlo Modeling of solar minimum and solar maximum with the inclusion of a worst-case solar particle event over a one-year mission without geomagnetic shielding, the TID for minimum and maximum conditions for a generic 3U with a wall thickness of 0.254 cm is 158 RAD and 1540 RAD, respectively. The modeled total solar maximum TID is over estimated, because at low orbital latitudes a spacecraft will have shielding from the Earth’s magnetic field. However, TID will still be significant at high latitudes over the poles, where a spacecraft is exposed in a solar particle event. In contrast to a thin-walled generic 3U CubeSat, the Shields-1 electronics enclosure has a shielding effectiveness of 21.3 g/cm 2 from NOVICE Sigma modeling and is expected to show reduced total ionizing dose increases during the present active Solar Cycle 25 period. Because solar particle events during solar maximum increase TID on electronic parts with thin-walled shielding in short periods of time, it is a mission assurance and reliability consideration on the mission value of the spacecraft versus adding shielding for risk reduction of premature spacecraft or instrument payload loss. Since the volumes of many instruments and system electronics have reduced with small spacecraft, shielding material costs and weight penalties have diminished. A small spacecraft project budget and schedule may limit traditional radiation-hardened part use and radiation testing requirements, where shielding can contribute to mission assurance and reliability with reduced costs.

Shields-1↗

Improved Hybrid Modeling of Spent Fuel Storage Facilities

This work developed a new computational method for improving the ability to calculate the neutron flux in deep-penetration radiation shielding problems that contain areas with strong streaming. The “gold standard” method for radiation transport is Monte Carlo (MC) as it samples the physics exactly and requires few approximations. Historically, however, MC was not useful for shielding problems because of the computational challenge of following particles through dense shields. Instead, deterministic methods, which are superior in term of computational effort for these problems types but are not as accurate, were used. Hybrid methods, which use deterministic solutions to improve MC calculations through a process called variance reduction, can make it tractable from a computational time and resource use perspective to use MC for deep-penetration shielding. Perhaps the most widespread and accessible of these methods are the Consistent Adjoint Driven Importance Sampling (CADIS) and Forward-Weighted CADIS (FW-CADIS) methods. For problems containing strong anisotropies, such as power plants with pipes through walls, spent fuel cask arrays, active interrogation, and locations with small air gaps or plates embedded in water or concrete, hybrid methods are still insufficiently accurate. In this work, a new method for generating variance reduction parameters for strongly anisotropic, deep penetration radiation shielding studies was developed. This method generates an alternate form of the adjoint scalar flux quantity, Φ Ω , which is used by both CADIS and FW-CADIS to generate variance reduction parameters for local and global response functions, respectively. The new method, called CADIS-Ω, was implemented in the Denovo/ADVANTG software. Results indicate that the flux generated by CADIS-Ω incorporates localized angular anisotropies in the flux more effectively than standard methods. CADIS-Ω outperformed CADIS in several test problems. This initial work indicates that CADIS- may be highly useful for shielding problems with strong angular anisotropies. This is a benefit to the public by increasing accuracy for lower computational effort for many problems that have energy, security, and economic importance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimal Shielding Design For Minimum Materials Cost or Mass - Paper 128

Material costs dominate some shielding design problems. This is certainly the case for manned nuclear power space applications for which shielding is essential and the cost of launching by rocket from Earth is high. In such situations or in those where shielding volume or mass is constrained, it is important to optimize the design. Although trial and error synthesis methods may succeed, a more systematic approach is warranted. Design automation may also potentially reduce engineering costs. The objective is to automate the design of optimal radiation shielding to meet specified attenuation requirements given a menu of allowed shielding materials, their properties and their delivered costs per unit volume. The cost-optimal design is one which, at each location in the shield, chooses the menu material minimizing a particular functional of forward and adjoint angular fluxes plus material cost. Thus a Boltzmann forward and adjoint angular flux solver with additional calculations can evaluate whether a shield design is optimal or whether improvements are possible. An iterative algorithm based on approximated optimality is proposed to solve for the optimal shield design and numerical experiments with it are discussed. The future use of 3D Boltzmann solvers will allow extending results to shaped shield designs in which material is not wasted to maintain unneeded spherical symmetry. The largest cost savings of automated optimal design of shielding is expected to be for applications involving nuclear powered manned space missions where the required shielding attenuation of radiation and costs are both large. However, less exotic applications such as the shielding of radiation facilities on Earth could also benefit from optimal shielding design, and automation of the design process may reduce engineering costs. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

Design of the FRIB Cryomodule

An advanced, modular bottom-supported cryomodule design is described which is highly optimized for mass-production and efficient precision-assembly. The FRIB driver linac uses 4 types of superconducting resonators and 2 solenoid lengths which in turn require 7 individual cryomodule configurations. To meet alignment tolerances a precision-machined bolted cryomodule rail system is described. A novel, kinematic mounting system of the cold mass is introduced which allows for thermal contractions while preserving alignment. A first prototype will incorporate a wire position monitor for alignment verification. The cold alignment structure is supported by composite posts which also function as thermal isolators. The cryogenic system provides separate 2 K and 4.5 K liquid helium lines to cavities and solenoids. Details of the JT valves, heat exchanger, cool-down circuit and junction to cryogenic line will be provided. Transient cool-down was simulated for stresses and buckling failure. A 1100-O Aluminum shield is used as a thermal radiation shield. The paper also describes cryomodule interfaces with the linac tunnel, the RF input cables, and the cryogenic distribution system.

43 PARTICLE ACCELERATORS↗

Radiation Transport and Shielding Challenges at NASA Marshall Space Flight Center

Several unique radiation transport and shielding challenges for various spacecraft and ground test facilities have recently been explored at NASA Marshall Space Flight Center (MSFC). Many radiation transport methods and code packages have been utilized during this effort, and some additional analytical tools have been developed to support this work. This includes the development of a nuclear thermal propulsion stage, in which radiation damage to hardware, radiation heating, and crew dose must be assessed for a large spacecraft. Radiation shielding for such a stage must be optimized to minimize weight, and additional dose consequences are expected from cosmic sources. Development of a nuclear engine requires ground test facilities, which themselves require significant development effort that includes deep-penetration shielding analysis for facility design and site selection. Additional radiation transport analysis has been performed in support of a notional lander mission to Europa, the icy moon of Jupiter. The radiation burden to spacecraft has been analyzed, and charged particle radiation transport methods have been utilized to apply correct doses to material samples in ground test facilities.

Caffrey, Jarvis A.↗