Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Proton radiation effects on multi-pinned-phased CCDs

Three Tektronix 1024 x 1024 multi-pinned-phased (MPP) charge coupled devices were irradiated with protons to obtain data on CCD performance degradation in a proton radiation environment. The devices were irradiated with a spectrum of energies up to 120 MeV, simulating the total radiation dose of a long-term space experiment. Basic parameters such as charge transfer efficiency, dark current, noise, and full well were measured before and after irradiation. A test was also performed to determine the effectiveness of various thicknesses of tantalum shielding in protecting the CCD from damage. Dark current increase and CTE degradation were the most noticeable effects of proton radiation. This paper will present the objectives, test data, and conclusions of the proton testing, and will identify future testing to be performed.

Murata-Seawalt, D.↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality Assurance Plan for Federal Guidance Report 16

Federal Guidance Report No. 16 will provide risk coefficients for use in projecting the probability of cancer morbidity or mortality from exposure to environmental radionuclides. The derivation of nuclide-specific risk coefficients involves multiple steps, with each step relying on the accuracy of the previous step as well as the numerical data utilized within each step. Thus, to ensure the quality of the derived risk coefficients, it is necessary to evaluate and confirm the quality and proper implementation of input data at each step of the derivation. The Oak Ridge National Laboratory (ORNL) dosimetry research team currently has two largely independent software codes for deriving radiation dose estimates, dose coefficients, and cancer risk coefficients for internally deposited radionuclides: DCAL and QCAL. The agreement of derived values based on alternate codes is an important step in quality assurance (QA) of the risk coefficients produced in this project. DCAL is an integration of the dosimetric software and numerical databases developed at ORNL over the past 25 years for the EPA’s Office of Radiation and Indoor Air (ORIA). QCAL was developed in 2015 to serve as a substitute for DCAL while DCAL was undergoing revision and to provide QA for the updated version of DCAL. The complex methodology employed in the derivation of cancer risk coefficients presents a challenge for QA, and as such, this report describes the QA steps used by the ORNL dosimetry team in this process as implemented in DCAL and QCAL for Federal Guidance Report No. 16.

61 RADIATION PROTECTION AND DOSIMETRY↗

ECAR-6573 Rev 0 PGS Stirling Engine Radiation Lifetime Estimate

This evaluation determines the expected service lifetime for the Stirling Engines in the Power Generation Subsystem (PGS) based on the radiation resistance of the organic materials, electrical components, and magnets, along with the projected radiation dose rate. Components that are not projected to last for a six-month operational period are discussed in more detail, including their associated risk due to failure and possible remedial actions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A structural model of the long-term degradation of the concrete biological shield

The concrete biological shield (CBS) of light water reactors is exposed to high neutron radiation dose in the long term, which may lead to the degradation of the concrete’s mechanical properties. Given the important shielding role of the CBS, it is necessary to investigate the irradiation effects at the structural scale and provide estimates of the damage extent from the wall’s inner surface to study potential license renewals. For this purpose, we developed a mechanical model accounting for radiation-induced expansion, creep, and damage in concrete using the Grizzly finite element code, informed by ex-core neutron flux calculations using the VERA tool. The model was applied to a 3D CBS structure represented by the CBS wall, a steel liner, reinforcement bars, and a concrete base mat and evaluated damage at 40, 60, and 80 years of operation. The VERA model predicted a maximum fluence of approximately 2 x 10 19 ncm -2 at 80 years of operation. The results showed that damage is highest at the inner surface of the CBS wall and gradually decreases with depth. It extends beyond the rebar after 60 years and reaches a depth of approximately 12 cm at 80 years.

42 ENGINEERING↗

QUIC-DEPDOSE: Software tools to prepare for and respond to nuclear emergencies

QUIC-DEPDOSE is a software application that calculates radiation doses from inhalation of radionuclides downstream from an atmospheric radiological release. Unlike other radiological modeling software, QUIC-DEPDOSE can provide accurate dose information in as little as an hour running on a regular laptop, allowing for use by emergency responders after an accident.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermal stability of electron-irradiated poly(tetrafluoroethylene) - X-ray photoelectron and mass spectroscopic study

Polytetrafluoroethylene (PTFE) was subjected to 3 keV electron bombardment and then heated in vacuum to 300 C. The behavior of the material as a function of radiation dose and temperature was studied by X-ray photoelectron spectroscopy (XPS) of the surface and mass spectroscopy of the species evolved. Lightly damaged material heated to 300 C evolved saturated fluorocarbon species, whereas unsaturated fluorocarbon species were evolved from heavily damaged material. After heating the heavily damaged material, those features in the XPS spectrum that were associated with damage diminished, giving the appearance that the radiation damage had annealed. The observations were interpreted by incorporating mass transport of severed chain fragments and thermal decomposition of severely damaged material into the branched and cross-linked network model of irradiated PTFE. The apparent annealing of the radiation damage was due to covering of the network by saturated fragments that easily diffused through the decomposed material to the surface region upon heating.

Wheeler, Donald R.↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of a high-temperature cell for cobalt-60 irradiations of aqueous solutions with in situ UV–visible spectroscopy

To understand the speciation of solutes in aqueous solutions in high temperature radiation environments, we report the design and fabrication of a custom-built, high temperature (≤300 °C) titanium irradiation cell with in situ optical spectroscopy capabilities, as afforded by coupled fiber optic cables. The wetted surfaces of the 8-inch tall cylindrical cell with 3.5 in. diameter are entirely made of titanium, sapphire, and gold, which are chemically and radiolytically inert. The initial benchmarking results are reported, including the baseline spectrum of deionized water as a function of temperature, the stability of a spectrum over 4 h at 100 °C, and an irradiated Fricke dosimetry solution under ambient irradiator temperature conditions (27.0 ± 0.5 °C). Further, the average gamma radiation dose rate in the cell in its current configuration is 26.1 ± 1.3 Gy min -1 . This cell has application in studying several processes throughout the nuclear fuel cycle, including the reactor coolant behavior.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Observation of radiation induced changes in stress and electrical properties in MOS devices

Strain measurements using X-ray diffraction were performed on irradiated commercial and radiation-hardened metal gate CMOS devices in addition to polysilicon gate NMOS devices. I-V curves were taken and V(ot) and V(it) were separated using the subthreshold slope method for all devices. A correlation has been shown to exist between physical strain relaxation and the electrical properties as a function of radiation dose and recovery. Data shown suggest that the physical response (strain relaxation) in the silicon at the oxide interface is a measure of the type of damage induced and the recovery mechanism. Postradiation measurements of Delta V(it) and Delta V(ot) taken immediately after irradiation support the conclusions of V. Zekeriya and T.-P. Ma (1983) and K. Kasama et al. (1986, 1987); compressive stress at the silicon/SiO2 interface does reduce radiation damage in the device.

Shaw, D. C.↗

Nuclear safe orbit basing considerations

Consideration is given to one aspect of space nuclear power safety, namely, the radiation dose rate risk due to a reentered reactor. It is found that for nuclear-thermal propulsion NERVA vehicles, the minimum required altitude for initial basing and earth escape is 500 to 600 km; for final end-of-life storage, the required altitude is about 1000 km. For a 10-MWe nuclear-electric propulsion vehicle, the basing node is 800 km and the final end-of-life storage altitude is 1100 km. Radiation levels have been evaluated for both the SP-100 nuclear electric and the NERVA nuclear thermal reactors as a function of operating time, power level, and time after shutdown.

Frisbee, Robert H.↗

Radiological Impact of 2023 Operations at the Savannah River Site

This report presents the environmental dose assessment methods and the estimated potential doses to the public from 2023 Savannah River Site (SRS) air and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios, such as the consumption of wildlife or goat milk. Dose to the Offsite Representative Person The 2023 dose to the offsite representative person from SRS liquid releases was 0.14 mrem and from SRS air releases it was 0.016 mrem. To show compliance with the U. S. Department of Energy (DOE) all pathway dose standard of 100 mrem/yr, SRS conservatively adds these two doses for a total representative person dose of 0.16 mrem which is 0.16% of the DOE standard. Sportsman Doses Onsite Hunter: SRS conducts annual hunts to control onsite deer and feral hog populations. The estimated dose from consuming harvested deer or hog meat is determined for every onsite hunter. During 2023, the maximum potential dose an onsite hunter received was 9.42 mrem, or 9.42% of DOE’s 100 mrem/yr all pathway dose standard. Creek Mouth Fisherman: SRS estimated the maximum potential dose from fish consumption at 0.17 mrem from bass collected at the mouth of Lower Three Runs. This dose is 0.17% of the DOE standard. SRS bases this hypothetical dose on the low probability scenario that, during 2023, a fisherman consumed 24 kg (53 lbs) of bass caught exclusively from the mouth of Lower Three Runs. Release of Material Containing Residual Radioactivity SRS did not release any real property (land or buildings) in 2023. SRS unconditionally released a total of 13,324 items of personal property (such as tools) from radiological areas in 2023. Most of these items did not leave the Site. However, all of these items required no additional radiological controls post-survey as they met DOE Order 458.1 release criteria. Radiation Dose to Aquatic and Terrestrial Biota SRS conducts screening evaluations of plant and animal doses for aquatic and terrestrial ecosystems. For 2023, all SRS aquatic system locations passed the initial (Level 1) screenings and no further assessments were required at those locations. For the land-based systems evaluation, SRS performed initial screenings using concentration data from the five onsite radiological soil sampling locations. Typically, SRS collects and analyzes only one soil sample per year from each location. For 2023, all land-based locations passed their initial (Level 1) pathway screenings.

54 ENVIRONMENTAL SCIENCES↗

Effects of Six Sequential Charged Particle Beams on Behavioral and Cognitive Performance in B6D2F1 Female and Male Mice

The radiation environment astronauts are exposed to in deep space includes galactic cosmic radiation (GCR) with different proportions of all naturally occurring ions. To assist NASA with assessment of risk to the brain following exposure to a mixture of ions broadly representative of the GCR, we assessed the behavioral and cognitive performance of female and male C57BL/6J × DBA2/J F1 (B6D2F1) mice two months following rapidly delivered, sequential 6 beam irradiation with protons (1 GeV, LET = 0.24 keV, 50%), 4 He ions (250 MeV/n, LET = 1.6 keV/μm, 20%), 16 O ions (250 MeV/n, LET = 25 keV/μm 7.5%), 28 Si ions (263 MeV/n, LET = 78 keV/μm, 7.5%), 48Ti ions (1 GeV/n, LET = 107 keV/μm, 7.5%), and 56 Fe ions (1 GeV/n, LET = 151 keV/μm, 7.5%) at 0, 25, 50, or 200 cGy) at 4–6 months of age. When the activity over 3 days of open field habituation was analyzed in female mice, those irradiated with 50 cGy moved less and spent less time in the center than sham-irradiated mice. Sham-irradiated female mice and those irradiated with 25 cGy showed object recognition. However, female mice exposed to 50 or 200 cGy did not show object recognition. When fear memory was assessed in passive avoidance tests, sham-irradiated mice and mice irradiated with 25 cGy showed memory retention while mice exposed to 50 or 200 cGy did not. The effects of radiation passive avoidance memory retention were not sex-dependent. There was no effect of radiation on depressive-like behavior in the forced swim test. There was a trend toward an effect of radiation on BDNF levels in the cortex of males, but not for females, with higher levels in male mice irradiated with 50 cGy than sham-irradiated. Finally, sequential 6-ion irradiation impacted the composition of the gut microbiome in a sex-dependent fashion. Taxa were uncovered whose relative abundance in the gut was associated with the radiation dose received. Thus, exposure to sequential six-beam irradiation significantly affects behavioral and cognitive performance and the gut microbiome.

60 APPLIED LIFE SCIENCES↗

Transient histone deacetylase inhibition reveals cell type invariant and specific effects of chromatin decondensation on irradiation response

Radiation therapy plays a prominent role in breast cancer treatment, but the high doses of radiation damage both healthy and cancerous cells. Therefore, additional research is needed into combination therapies that could preferentially radiosensitize cancer cells compared to surrounding healthy tissue without causing deleterious side effects. Histone deacetylase inhibitor drugs (HDACis) have been tested as radiosensitizers in both basic research and clinical trials, but the long exposure time typically used in these treatments and the lack of matched healthy cell controls often leave aspects of their mechanism of action unclear. Here, we show that transient (2 h) trichostatin A (TSA) treatment of cancerous and non-tumorigenic breast epithelial cell lines increases immediate DNA damage and decreases long term cell viability in both cell types at high radiation doses. Transient TSA treatment also causes an increase in DNA damage signals after 5 Gy X-rays in other cancer and healthy cell types: A375 melanoma cells and BJ5-ta fibroblasts. This suggests that chromatin decompaction acts to increase cellular vulnerability to initial DNA damage from high doses of radiation in a cell type independent manner that does not rely on changes to DNA repair pathways caused by longer TSA treatment. However, responses to lower doses of radiation and long term survival are more cell type specific: only MCF7 cells experience an effect of TSA on DNA damage after 1 Gy X-ray radiation while MCF10a cells experience somewhat more evident cell viability effects of combined TSA and radiation treatment long term.

Li, Heng [Biochemistry & Cellular and Molecular Bi↗

Evaluating county-level lung cancer incidence from environmental radiation exposure, PM 2.5 , and other exposures with regression and machine learning models

Characterizing the interplay between exposures shaping the human exposome is vital for uncovering the etiology of complex diseases. For example, cancer risk is modified by a range of multifactorial external environmental exposures. Environmental, socioeconomic, and lifestyle factors all shape lung cancer risk. However, epidemiological studies of radon aimed at identifying populations at high risk for lung cancer often fail to consider multiple exposures simultaneously. For example, moderating factors, such as PM 2.5 , may affect the transport of radon progeny to lung tissue. This ecological analysis leveraged a population-level dataset from the National Cancer Institute’s Surveillance, Epidemiology, and End-Results data (2013–17) to simultaneously investigate the effect of multiple sources of low-dose radiation (gross γ activity and indoor radon) and PM 2.5 on lung cancer incidence rates in the USA. County-level factors (environmental, sociodemographic, lifestyle) were controlled for, and Poisson regression and random forest models were used to assess the association between radon exposure and lung and bronchus cancer incidence rates. Tree-based machine learning (ML) method perform better than traditional regression: Poisson regression: 6.29/7.13 (mean absolute percentage error, MAPE), 12.70/12.77 (root mean square error, RMSE); Poisson random forest regression: 1.22/1.16 (MAPE), 8.01/8.15 (RMSE). The effect of PM 2.5 increased with the concentration of environmental radon, thereby confirming findings from previous studies that investigated the possible synergistic effect of radon and PM 2.5 on health outcomes. In summary, the results demonstrated (1) a need to consider multiple environmental exposures when assessing radon exposure’s association with lung cancer risk, thereby highlighting (1) the importance of an exposomics framework and (2) that employing ML models may capture the complex interplay between environmental exposures and health, as in the case of indoor radon exposure and lung cancer incidence.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Association of human T-cell leukemia virus type 1 with prevalent rheumatoid arthritis among atomic bomb survivors: A cross-sectional study

Previous studies have suggested that human T-cell leukemia virus type 1 (HTLV-1) might act as a pathogen in rheumatoid arthritis (RA), but epidemiological evidence of an association is scarce. We measured anti-HTLV-1 antibodies among Nagasaki atomic bomb survivors to determine whether HTLV-1 is related to RA and whether radiation exposure is associated with HTLV-1 and RA prevalence. This is a cross-sectional study among atomic bomb survivors who participated in biennial health examinations from 2006 to 2010. Serum levels of anti-HTLV-1 antibodies were measured using a chemiluminescent enzyme immunoassay and confirmed by Western blotting. Association between HTLV-1 and RA was analyzed by a logistic regression model. Of 2091 participants (women 61.5%; median age, 73 years), 215 (10.3%) had anti-HTLV-1 antibodies. HTLV-1 prevalence was higher among women (13.1% vs 5.8%; P<.001). Twenty-two participants (1.1%) were diagnosed with RA. HTLV-1 prevalence among RA participants was significantly higher than that among non-RA participants (27.3% vs 10.1%; P=.020). After adjustment for age, sex, and hepatitis C virus infection, HTLV-1 was significantly associated with prevalent RA (odds ratio, 2.89; 95% confidence interval, 1.06, 7.03). There was no association between radiation dose and either the prevalence of HTLV-1 or RA. This study, among a well-defined group of atomic bomb survivors, suggests that HTLV-1 is associated with RA. Abbreviations: AHS = Adult Health Study, ATL/ATLL = adult T cell leukemia/lymphoma, bioDMARDs = biological disease modifying antirheumatic drugs, CCP = cyclic citrullinated peptide, CI = confidence interval, CLEIA = chemiluminescent enzyme immunoassay, CRP = C-reactive protein, csDMARDs = conventional synthetic disease modifying antirheumatic drugs, Gy = gray, HCV = hepatitis C virus, HTLV-1 = human T-cell leukemia virus type 1, IF = immunofluorescent, RA = rheumatoid arthritis, RERF = Radiation Effects Research Foundation, RF = rheumatoid factor, SS = Sjogren syndrome.

59 BASIC BIOLOGICAL SCIENCES↗

Dioctyl ether radiolysis under used nuclear fuel reprocessing conditions: Foundational knowledge for the development of sacrificial ligand grafts

Radiation-induced ligand destruction and concomitant degradation product formation is unavoidable under envisioned used nuclear fuel reprocessing conditions, and ultimately limits the recyclability of a given solvent system formulation. With this in mind, a novel approach to ligand innovation for advanced separations processes is in the design of tailored “protomolecules,” which when exposed to ionizing radiation undergo desired chemical transformations, thereby allowing for a reprocessing solvent system to advantageously evolve with absorbed radiation dose. Here we provide foundational knowledge for the time-resolved (electron pulse) and steady-state (cobalt-60 gamma) radiolytic behavior of dioctyl ether, a protomolecule grafting surrogate. Gamma irradiation of single-phase solutions of dioctyl ether (5–100 vol.%) in n-dodecane resulted in the loss of dioctyl ether (G = -0.72 µmol J –1 ) and the formation of octane (G = 0.11 µmol J –1 ) and octanol (G = 0.15 µmol J –1 ) degradation products, the latter of which is a known reprocessing phase modifier and radioprotectant. Further, these radiation-induced changes were attributed to direct radiation effects, for more concentrated dioctyl ether solutions, and indirect radiation effects, predominantly driven by the reaction of dioctyl ether with the dodecane radical cation, for which we report a second-order rate coefficient of k = (1.53 ± 0.05) × 10 10 L mol –1 s –1 . Under typical biphasic extraction (4.0 mol L –1 HNO 3 ) and strip (0.1 mol L –1 HNO 3 ) reprocessing conditions, gamma irradiation of 5 vol.% dioctyl ether solvent systems afforded negligible change in the rate of parent molecule destruction but promoted significant differences in the radiolytic behavior of its degradation products. These differences are attributed to their respective interactions with [dioctyl ether/HNO 3 /H 2 O] and [octanol/HNO 3 /H 2 O] adducts extracted into the organic phase. Overall, these results support the grafting of ether linkages to advanced separations ligands (e.g., modified diglycolamides).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗